首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   40篇
  免费   1篇
  国内免费   2篇
临床医学   1篇
综合类   2篇
预防医学   1篇
药学   38篇
中国医学   1篇
  2021年   6篇
  2019年   3篇
  2018年   4篇
  2017年   3篇
  2014年   3篇
  2013年   2篇
  2012年   1篇
  2011年   7篇
  2009年   4篇
  2008年   7篇
  2006年   2篇
  2000年   1篇
排序方式: 共有43条查询结果,搜索用时 31 毫秒
1.
The present study aimed at formulating and optimizing natamycin (NT)-loaded polyethylene glycosylated nano-lipid carriers (NT-PEG-NLCs) using Box-Behnken design and investigating their potential in ocular applications. Response surface methodology computations and plots for optimization were performed using Design-Expert® software to obtain optimum values for response variables based on the criteria of desirability. Optimized NT-PEG-NLCs had predicted values for the dependent variables which are not significantly different from the experimental values. NT-PEG-NLCs were characterized for their physicochemical parameters; NT's rate of permeation and flux across rabbit cornea was evaluated, in vitro, and ocular tissue distribution was assessed in rabbits, in vivo. NT-PEG-NLCs were found to have optimum particle size (<300 nm), narrow polydispersity index, and high NT entrapment and NT content. In vitro transcorneal permeability and flux of NT from NT-PEG-NLCs was significantly higher than that of Natacyn®. NT-PEG-NLC (0.3%) showed improved delivery of NT across the intact cornea and provided concentrations statistically similar to the marketed suspension (5%) in inner ocular tissues, in vivo, indicating that it could be a potential alternative to the conventional suspension during the course of fungal keratitis therapy.  相似文献   
2.
生物相关性溶出度方法研究进展   总被引:1,自引:1,他引:0  
摘要:建立具有生物相关性的溶出度方法目的在于通过理想的体外溶出试验预测体内药代动力学过程。近年来,研究表明在生物相关性溶出介质中选择合适的溶出装置进行溶出试验得到的溶出曲线能较好地反映其在体内的溶出行为,计算机模拟软件可为建立合理的体外溶出度方法提供指导和依据。通过采用合适的生物相关性溶出介质、溶出装置,结合计算机模拟软件可建立A级水平的IVIVC(in vitro-in vivo correlation),可能代替生物等效性研究。  相似文献   
3.
Lipid-based formulations have been an attractive choice among novel drug delivery systems for enhancing the solubility and bioavailability of poorly soluble drugs due to their ability to keep the drug in solubilized state in the gastrointestinal tract. These formulations offer multiple advantages such as reduction in food effect and inter-individual variability, ease of preparation, and the possibility of manufacturing using common excipients available in the market. Despite these advantages, very few products are available in the present market, perhaps due to limited knowledge in the in vitro tests (for prediction of in vivo fate) and lack of understanding of the mechanisms behind pharmacokinetic and biopharmaceutical aspects of lipid formulations after oral administration. The current review aims to provide a detailed understanding of the in vivo processing steps involved after oral administration of lipid formulations, their pharmacokinetic aspects and in vitro in vivo correlation (IVIVC) perspectives. Various pharmacokinetic and biopharmaceutical aspects such as formulation dispersion and lipid digestion, bioavailability enhancement mechanisms, impact of excipients on efflux transporters, and lymphatic transport are discussed with examples. In addition, various IVIVC approaches towards predicting in vivo data from in vitro dispersion/precipitation, in vitro lipolysis and ex vivo permeation studies are also discussed in detail with help of case studies.KEY WORDS: Pharmacokinetics, Lipolysis, IVIVC, Efflux transporters, Lymphatic delivery, Food effectAbbreviations: ADME, absorption/distribution/metabolism/elimination; AUC, area under the curve; BCS, biopharmaceutics classification system; BDDCS, biopharmaceutics drug disposition classification system; CACO, human epithelial colorectal adenocarcinoma cells; Cmax, maximum plasma concentration; CMC, critical micellar concentration; CYP, cytochrome; DDS, drug delivery systems; FaSSGF, fasted-state simulated gastric fluid; FaSSIF, fasted-state simulated intestinal fluid; FeSSIF, fed-state simulated intestinal fluid; GIT, gastrointestinal tract; IVIVC, in vitro in vivo correlation; LCT, long chain triglyceride; LFCS, lipid formulation classification system; log P, n-octanol/water partition coefficient; MCT, medium chain triglyceride; MDCK, Madin–Darby canine kidney cells; NCE, new chemical entity; P-app, apparent permeability; P-gp, permeability glycoprotein; SCT, short chain triglyceride; SEDDS, self-emulsifying drug delivery system; SIF, simulated intestinal fluid; SMEDDS, self-microemulsifying drug delivery system; SNEDDS, self-nanoemulsifying drug delivery system; Vit E, vitamin E  相似文献   
4.
The usefulness of selected biorelevant dissolution media (BDM) to predict in vivo drug absorption was studied. Dissolution profiles of solid formulations of a poorly soluble model compound were compared in BDM simulating fasted and two levels of fed state. A non-physiologically relevant medium containing the cationic surfactant, cetrimide, was also investigated. All the media studied were capable of differentiating between the formulations employed, with formulation A consistently ranking high and formulations C and D ranking low. An in vivo dog study was carried out and an attempt was made to obtain a level A correlation between the plasma absorption curves and in vitro dissolution curves, using non-linear regression software. The in vitro-in vivo correlation (IVIVC) models developed indicated that fed state media (BDM 3) containing high levels of both bile salts (BS) and lipolysis products (LP) were best able to predict in vivo pharmacokinetic parameters (Cmax and AUC) with prediction errors lower than 10%. Overall, design and use of appropriate media for in vitro dissolution is extremely important. This study demonstrates the potential of physiologically relevant media containing both BS and LP for use in formulation and early drug development.  相似文献   
5.

Purpose

The purpose of this study was to compare the dissolution behaviour of etoricoxib in different dissolution media and to establish in vitro/in vivo correlation (IVIVC) using computer simulations.

Methods

Drug solubility was measured in different media. The dissolution behaviour of etoricoxib was studied in the USP Apparatus 2 using different dissolution media. A dissolution transfer model was used to investigate if the drug stays in solution when the pH of the medium changes. Drug permeability assessment was performed using the caco-2 cell culture technique. The in vitro data were used as input functions in GastroPlus™ to simulate the in vivo profiles of the drug.

Results

Solubility of etoricoxib was highest at low pH, and there was no significant difference in the solubility observed between blank buffers and biorelevant media of similar pH. The drug remained solubilised when transferred into simulated intestinal fluids. Using the in vitro data as input function in Gastro Plus, an IVIVC was established. Further simulations confirmed that the drug absorption occurs similar to the absorption of an oral solution.

Conclusions

Due to the solubility behaviour within the physiological pH gradient of the gastrointestinal tract, etoricoxib can be classified as an intermediate class 1/2 drug rather than BCS class 2. In vitro results combined with in silico simulations using GastroPlus support scientifically that a biowaiver for immediate release etoricoxib solid oral dosage forms is justified.  相似文献   
6.
The number of marketed oral osmotically driven systems (OODS) has doubled in the last 10 years. The main clinical benefits of OODS are their ability to improve treatment tolerability and patient compliance. These advantages are mainly driven by the capacity to deliver drugs in a sustained manner, independent of the drug chemical properties, of the patient’s physiological factors or concomitant food intake. However, access to these technologies has been restricted by the crowded patent landscape and manufacturing challenges. In this review article, we intend to give an overview of the OODS development in the last 30 years, detailing the technologies, specific products and their clinical use. General guidance on technology selection is described in light of the recent advances in the field. The clinical performance of these technologies is also discussed, with a focus on food effects and the in vivo-in vitro correlation. Special attention is paid to safety given the controversial case study of Osmosin®. Overall, oral osmotically driven systems appear to be a promising technology for product life-cycle strategies.  相似文献   
7.
Sutton SC  Hu M 《The AAPS journal》2006,8(2):E307-E313
Many mathematical models have been proposed for establishing an in vitro/in vivo correlation (IVIVC). The traditional IVIVC model building process consists of 5 steps: deconvolution, model fitting, convolution, prediction error evaluation, and cross-validation. This is a time-consuming process and typically a few models at most are tested for any given data set. The objectives of this work were to (1) propose a statistical tool to screen models for further development of an IVIVC, (2) evaluate the performance of each model under different circumstances, and (3) investigate the effectiveness of common statistical model selection criteria for choosing IVIVC models. A computer program was developed to explore which model(s) would be most likely to work well with a random variation from the original formulation. The process used Monte Carlo simulation techniques to build IVIVC models. Data-based model selection criteria (Akaike Information Criteria [AIC], R2) and the probability of passing the Food and Drug Administration "prediction error" requirement was calculated. To illustrate this approach, several real data sets representing a broad range of release profiles are used to illustrate the process and to demonstrate the advantages of this automated process over the traditional approach. The Hixson-Crowell and Weibull models were often preferred over the linear. When evaluating whether a Level A IVIVC model was possible, the model selection criteria AIC generally selected the best model. We believe that the approach we proposed may be a rapid tool to determine which IVIVC model (if any) is the most applicable.  相似文献   
8.
1. Aldehyde oxidase (AO enzymes)-mediated oxidation predominantly occurs at a carbon atom adjacent to the nitrogen on aromatic azaheterocycles. In the current report, we identified that AO enzymes oxidation took place at both the C-2 and C-4 positions of the methylquinoline moiety of Compound A based on data from mass spectrometric analysis, AO enzymes “litmus” test, and comparison with authentic standards.

2. To assess the potential for inadequate coverage for these two AO enzyme-mediated metabolites in nonclinical safety studies, given concerns due to differences in AO enzymes expression between preclinical species and humans, the human circulating levels of the two AO enzyme-mediated metabolites were predicted prospectively using in vitro and in vivo models. Both formation clearance and elimination clearance of the two metabolites were predicted based on in vitro to in vivo correlation and comparison with in vivo data from rats.

3. The result showed that the 4-OH metabolite of Compound A would account for less than 3% of the total drug-related exposure in human plasma, while the exposure to the 2-oxo metabolite would be relatively high (~70%).

4. The predicted human exposure levels for the two metabolites are in similar ranges as those observed in monkeys. These data taken together support the advancement to clinical development of Compound A.  相似文献   

9.
Literature relevant to assessing whether BCS-based biowaivers can be applied to immediate release (IR) solid oral dosage forms containing carbamazepine as the single active pharmaceutical ingredient are reviewed. Carbamazepine, which is used for the prophylactic therapy of epilepsy, is a non-ionizable drug that cannot be considered “highly soluble” across the range of pH values usually encountered in the upper gastrointestinal tract. Furthermore, evidence in the open literature suggests that carbamazepine is a BCS Class 2 drug. Nevertheless, the oral absolute bioavailability of carbamazepine lies between 70 and 78% and both in vivo and in vitro data support the classification of carbamazepine as a highly permeable drug. Since the therapeutic and toxic plasma level ranges overlap, carbamazepine is considered to have a narrow therapeutic index. For these reasons, a BCS based biowaiver for IR tablets of carbamazepine cannot be recommended. Interestingly, in nine out of ten studies, USP dissolution conditions (900 mL water with 1% SLS, paddle, 75 rpm) appropriately discriminated among bioinequivalent products and this may be a way forward to predicting whether a given formulation will be bioequivalent to the comparator product.  相似文献   
10.
Purpose  The objectives of the study was to develop a dissolution test method that can be used to predict the oral absorption of montelukast sodium, and to establish an in vitro/in vivo correlation (IVIVC) using computer simulations. Methods  Drug solubility was measured in different media. The dissolution behaviour of montelukast sodium 10 mg film coated tablets was studied using the flow-through cell dissolution method following a dynamic pH change protocol, as well as in the USP Apparatus 2. Computer simulations were performed using GastroPlus™. Biorelevant dissolution media (BDM) prepared using bile salts and lecithin in buffers was used as the dissolution media, as well as the USP simulated intestinal fluid (SIF) pH 6.8 and blank FaSSIF pH 6.5. Dissolution tests in the USP Apparatus 2 were performed under a constant pH condition, while the pH range used in the flow through cells was pH 2.0 to 7.5. The in vitro data were used as input functions into GastroPlus™ to simulate the in vivo profiles of the drug. Results  The solubility of montelukast sodium was low at low pH, but increased as the pH was increased. There was no significant difference in solubility in the pH range of 5.0 to 7.5 in blank buffers, but the drug solubility was higher in biorelevant media compared with the corresponding blank buffers at the same pH. Using the flow through cells, the dissolution rate was fast in simulated gastric fluid containing 0.1% SLS. The dissolution rate slowed down when the medium was changed to FaSSIF pH 6.5 and increased when the medium was changed to FaSSIF medium at pH 7.5. In the USP Apparatus 2, better dissolution was observed in FaSSIF compared with the USP buffers and blank FaSSIF with similar pH values. Dissolution was incomplete with less than 10% of the drug dissolved in the USP-SIF, and was practically non existent in blank FaSSIF pH 6.5. The in vitro results of the dynamic dissolution test were able to predict the clinical data from a bioavailability study best. Conclusions  Dynamic dissolution testing using the flow through cell seems to be a powerful tool to establish in vitro/in vivo correlations for poorly soluble drugs as input function into GastroPlus.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏