Objective: To determine whether packed red blood cell (PRBC) transfusion affects post-prandial superior mesenteric artery blood flow velocities (SMA BFVs) in very-low birth weight (VLBW) neonates and if so, at what time point after transfusion restoration of previous SMA BFV patterns occurs.Design/Methods: VLBW pre-term neonates, older than 14 days and tolerating bolus enteral feedings administered every 3?h were enrolled in this prospective observational study. Pulsed Doppler ultrasound was used to measure pre- and post-prandial (at 45?min) time-averaged mean, peak and end diastolic velocities (TAMV, PSV, EDV) immediately before and after 15?ml/kg of PRBC transfusion was given over 3?h; patent ductus arteriosus (PDA) status was also evaluated. Subsequent pre- and post-prandial SMA BFVs were recorded 24 and 48?h after the transfusion.Results: Pre- and post-prandial measurements were obtained for 21 out of 25 enrolled infants. Post-prandial SMA BFVs were attenuated during the feedings immediately after transfusion; at 24 and 48?h after transfusion, changes in post-prandial SMA BFVs were similar to those measured prior to transfusion; the presence of the PDA did not affect results.Conclusions: PRBC transfusion blunted SMA BFV responses to feedings immediately after the transfusion with normalization observed 24?h post-transfusion. 相似文献
We evaluated RNA stability of Ebola virus in EDTA blood and urine samples collected from infected patients and stored in West Africa’s environmental conditions. In blood, RNA was stable for at least 18 days when initial cycle threshold values were <30, but in urine, RNA degradation occurred more quickly. 相似文献
IntroductionObstructive sleep apnea (OSA) is often connected with arterial hypertension and it could also be a cause of secondary hypertension. Treatment of arterial hypertension and optimal blood pressure level are important for prevention of cardiovascular complications. It is not well known how to treat patients with OSA and arterial hypertension. Also many patients with OSA suffer from metabolic syndrome which worsen their prognosis.AimThe aim of our study was to assess arterial hypertension compensation in patients with metabolic syndrome and moderate to severe OSA and to analyze used pharmacotherapy.Materials and methods85 hypertensive patients (75 men) with metabolic syndrome, average age 53.6 ± 9.3 years, were evaluated using overnight sleep study with diagnosis of OSA, average apnea–hypopnea index (AHI) 56.3 ± 23. Patients underwent 24 h ambulatory blood pressure monitoring (ABPM) and their current pharmacotherapy data were obtained. Appropriate combinations of antihypertensive drugs (patients with metabolic syndrome) were derived from ESH/ESC 2013 guidelines.ResultsArterial hypertension was well compensated in only 11.8% of the patients. 24.7% patients were treated according to current guidelines. Fisher's exact test with analysis of adjusted residues has found higher rate of blood pressure subcompensation in patients treated with triple+ combination of drugs (p = 0.035, 51.4% vs 10%).ConclusionOnly a small number of patients had optimal blood pressure level and were treated according to current ESH/ESC guidelines. We have to constantly appeal to all physicians to perform ABPM in patients with OSA. 相似文献
目的探讨8周基础军训(basic military training,BMT)对入伍新兵血像中红细胞及其相关指标的影响,为指导科学的军事训练提供参考。方法数据来自新疆边防部队2015年度入伍的50名男性新兵,分别在BMT前后测定并记录受试新兵的红细胞计数、血红蛋白浓度及血清铁蛋白等。结果经过8周的BMT,新兵血液中血红蛋白浓度、红细胞计数及血清铁蛋白均显著下降(P0.05,P0.01)。结论 8周BMT可能导致入伍新兵发生运动性贫血,铁缺乏可能是其主要原因。 相似文献
Women with pre-eclampsia have an increased risk of cardiovascular disease later in life. The aim of the study was to establish the presence and pattern of arterial stiffness in women previously with pre-eclampsia from a semi-rural region of South Africa. This was a prospective longitudinal study which involved 36 previously pre-eclamptic women and 86 non-pregnant controls (NPC) who had a past history of non-complicated pregnancy. Maternal wave reflection (augmentation index) and carotid-femoral pulse wave velocity were assessed noninvasively, using applanation tonometry with the SphygmoCor device. Endothelial function was assessed by EndoPAT 2000 device; pneumatic probes were fitted to the index fingers; induced flow-mediated reactive hyperemia; the ratio of the readings before and after occlusion was then used to calculate the score, the reactive hyperemia index (RHI) as a measure of endothelial function.
Pulse wave velocity remained significantly higher in previously pre-eclamptic women than non-pregnant controls up to three months after delivery (p < 0.05), then it reduced to nonsignificant values. All blood pressure indices (central and brachial pressures), were higher in previously pre-eclamptic women as compared to nonpregnant controls up to one year postpartum.
Regional (aortic) arterial stiffness, though it persists for some time after delivery, is transitory in previously pre-eclamptic women from the rural Africa setting. However, their increase blood pressure is an indication of compromised arterial compliance in women previously with pre-eclampsia. 相似文献
Rotary ventricular assist devices (VADs) are less sensitive to preload than the healthy heart, resulting in inadequate flow regulation in response to changes in patient cardiac demand. Starling‐like physiological controllers (SLCs) have been developed to automatically regulate VAD flow based on ventricular preload. An SLC consists of a cardiac response curve (CRC) which imposes a nonlinear relationship between VAD flow and ventricular preload, and a venous return line (VRL) which determines the return path of the controller. This study investigates the importance of a physiological VRL in SLC of dual rotary blood pumps for biventricular support. Two experiments were conducted on a physical mock circulation loop (MCL); the first compared an SLC with an angled physiological VRL (SLC‐P) against an SLC with a vertical VRL (SLC‐V). The second experiment quantified the benefit of a dynamic VRL, represented by a series of specific VRLs, which could adapt to different circulatory states including changes in pulmonary (PVR) and systemic (SVR) vascular resistance versus a fixed physiological VRL which was calculated at rest. In both sets of experiments, the transient controller responses were evaluated through reductions in preload caused by the removal of fluid from the MCL. The SLC‐P produced no overshoot or oscillations following step changes in preload, whereas SLC‐V produced 0.4 L/min (12.5%) overshoot for both left and right VADs. Additionally, the SLC‐V had increased settling time and reduced controller stability as evidenced by transient controller oscillations. The transient results comparing the specific and standard VRLs demonstrated that specific VRL rise times were improved by between 1.2 and 4.7 s ( = 3.05 s), while specific VRL settling times were improved by between 2.8 and 16.1 seconds ( = 8.38 s) over the standard VRL. This suggests only a minor improvement in controller response time from a dynamic VRL compared to the fixed VRL. These results indicate that the use of a fixed physiologically representative VRL is adequate over a wide variety of physiological conditions. 相似文献
Accurately predicting the hepatic clearance of compounds using in vitro to in vivo extrapolation (IVIVE) is crucial within the pharmaceutical industry. However, several groups have recently highlighted the serious error in the process. Although empirical or regression-based scaling factors may be used to mitigate the common underprediction, they provide unsatisfying solutions because the reasoning behind the underlying error has yet to be determined. One previously noted trend was intrinsic clearance-dependent underprediction, highlighting the limitations of current in vitro systems. When applying these generated in vitro intrinsic clearance values during drug development and making first-in-human dose predictions for new chemical entities though, hepatic clearance is the parameter that must be estimated using a model of hepatic disposition, such as the well-stirred model. Here, we examine error across hepatic clearance ranges and find a similar hepatic clearance-dependent trend, with high clearance compounds not predicted to be so, demonstrating another gap in the field. 相似文献