Objective: To determine whether packed red blood cell (PRBC) transfusion affects post-prandial superior mesenteric artery blood flow velocities (SMA BFVs) in very-low birth weight (VLBW) neonates and if so, at what time point after transfusion restoration of previous SMA BFV patterns occurs.Design/Methods: VLBW pre-term neonates, older than 14 days and tolerating bolus enteral feedings administered every 3?h were enrolled in this prospective observational study. Pulsed Doppler ultrasound was used to measure pre- and post-prandial (at 45?min) time-averaged mean, peak and end diastolic velocities (TAMV, PSV, EDV) immediately before and after 15?ml/kg of PRBC transfusion was given over 3?h; patent ductus arteriosus (PDA) status was also evaluated. Subsequent pre- and post-prandial SMA BFVs were recorded 24 and 48?h after the transfusion.Results: Pre- and post-prandial measurements were obtained for 21 out of 25 enrolled infants. Post-prandial SMA BFVs were attenuated during the feedings immediately after transfusion; at 24 and 48?h after transfusion, changes in post-prandial SMA BFVs were similar to those measured prior to transfusion; the presence of the PDA did not affect results.Conclusions: PRBC transfusion blunted SMA BFV responses to feedings immediately after the transfusion with normalization observed 24?h post-transfusion. 相似文献
We present a patient with both dynamic left ventricular outflow tract obstruction and valvular aortic stenosis. The aortic valve was calcified, and velocities and gradients measured by continuous‐wave Doppler met standard criteria for severe aortic stenosis. The increased subvalvular velocities invalidated assumptions of the simplified Bernoulli equation; correction using the longer form of the Bernoulli equation suggested a lower but still significant gradient. The complex shape of the subvalvular spectral Doppler envelope indicated supranormal systolic function and dynamic left ventricular outflow obstruction. Left heart catheterization with an end‐hole catheter was required to determine the subvalvular and valvular components of the obstruction. 相似文献
Objective: To evaluate the long-term clinical effect of high-intensity focussed ultrasound (HIFU) as a non-invasive modality for ablation of abdominal wall endometriosis (AWE) foci.
Methods: All women who were diagnosed with cutaneous endometriosis and underwent HIFU ablation and 4-year follow-up were included. Patient symptoms, imaging performed, HIFU ablation, recurrence, lesion location, size and number were collected and analyzed.
Results: A total of 51 women with 57 painful abdominal wall masses with a median volume of 4.00?cm3 and a mean age of 30.5±2.12 years were treated with HIFU. The main symptoms were a palpable painful abdominal mass (93%), protrusion of the skin (28.1%, 16) or lack of protrusion of the skin (71.9%, 41). Ultrasound was initially performed in 100% (51) of women, whereas 6% (3) required MRI examinations to distinguish the features and range of the masses. Ablation was performed with a median 300?s of sonication time, 40?min treatment time, 150?W of power and 41800?J of total energy to treat lesions that were a median volume of 3.83?cm3. No severe complications occurred, except in one patient with a first-degree skin burn, during the 48-month follow-up period. The pooled recurrence of cutaneous endometriosis occurred in 3.9% (2) of women.
Conclusion: The diagnosis of AWE should be confirmed with imaging of the lesion number, location, size and features before HIFU ablation. HIFU should be the first choice for the treatment of AWE as it is a non-invasive method, with high efficiency and safety and rapid postoperative recovery. 相似文献
Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital condition. It responds well to early diagnosis and treatment, but otherwise the prognosis is poor. We present our case series of 12 patients (mean age, 2 ± 2.58 yr; age range, 2 mo–8 yr), emphasizing the diagnostic process and discussing our surgical results. The diagnosis of ALCAPA should be suspected in infants who have dilated cardiomyopathy with electrocardiographic changes that suggest ischemia, and in older children who have isolated mitral regurgitation. When clinical suspicion is high, the results of 2-dimensional echocardiography combined with color-flow Doppler studies in expert hands can establish the diagnosis, thus avoiding angiography in critically ill infants. The treatment of choice in our patients was transfer and reimplantation of the left coronary artery onto the ascending aorta. There were 2 deaths: both were infants in extremis who underwent emergency surgery. An older child with severe ventricular dysfunction was given mechanical ventricular assistance and then heart transplantation. As of this report, all 10 survivors remained well and asymptomatic. 相似文献
Invasive coronary plaque imaging such as intravascular ultrasound and optical coherence tomography has been widely used to observe culprit or non-culprit coronary atherosclerosis, as well as optimize stent sizing, apposition and deployment. Coronary computed tomographic angiography (CTA) is non-invasively available to assess coronary artery disease (CAD) and has become an appropriate strategy to evaluate patients with suspected CAD. Given recent technologies, semi-automated plaque software is available to identify coronary plaque stenosis, volume and characteristics and potentially allows to be used for the assessment of more details of plaque information, progression and future risk as a surrogate tool of the invasive imaging modalities. This review article aims to focus on various evidence in coronary plaque imaging by coronary CTA and describes how accurate coronary CTA can classify coronary atherosclerosis. 相似文献
Objective: To assess the quality of images and video clips of fetal central nervous (CNS) structures obtained by ultrasound and transmitted via tele-ultrasound from Brazil to Australia.Methods: In this cross-sectional study, 15 normal singleton pregnant women between 20 and 26 weeks were selected. Fetal CNS structures were obtained by images and video clips. The exams were transmitted in real-time using a broadband internet and an inexpensive video streaming device. Four blinded examiners evaluated the quality of the exams using the Likert scale. We calculated the mean, standard deviation, mean difference, and p values were obtained from paired t tests.Results: The quality of the original video clips was slightly better than that observed by the transmitted video clips; mean difference considering all observers = 0.23 points. In 47/60 comparisons (78.3%; 95% CI?=?66.4–86.9%) the quality of the video clips were judged to be the same. In 182/240 still images (75.8%; 95% CI?=?70.0–80.8%) the scores of transmitted image were considered the same as the original.Conclusion: We demonstrated that long distance tele-ultrasound transmission of fetal CNS structures using an inexpensive video streaming device provided images of subjective good quality. 相似文献
Isotactic polypropylenes (iPP) with different melt flow indexes (MFI) were used to fabricate nanocomposites (NCs) with 10 wt % loadings of multi-wall carbon nanotubes (MWCNTs) using ultrasound-assisted extrusion methods to determine their effect on the morphology, melt flow, and electrical properties of the NCs. Three different types of iPPs were used with MFIs of 2.5, 34 and 1200 g/10 min. Four different NC fabrication methods based on melt extrusion were used. In the first method melt extrusion fabrication without ultrasound assistance was used. In the second and third methods, an ultrasound probe attached to a hot chamber located at the exit of the die was used to subject the sample to fixed frequency and variable frequency, respectively. The fourth method is similar to the first method, with the difference being that the carbon nanotubes were treated in a fluidized air-bed with an ultrasound probe before being used in the fabrication of the NCs with no ultrasound assistance during extrusion. The samples were characterized by MFI, Optical microscopy (OM), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM), electrical surface resistivity, and electric charge. MFI decreases in all cases with addition of MWCNTs with the largest decrease observed for samples with the highest MFI. The surface resistivity, which ranged from 1013 to 105 Ω/sq, and electric charge, were observed to depend on the ultrasound-assisted fabrication method as well as on the melt flow index of the iPP. A relationship between agglomerate size and area ratio with electric charge was found. Several trends in the overall data were identified and are discussed in terms of MFI and the different fabrication methods. 相似文献