PurposeTo evaluate the effectiveness and safety of fluoroscopy-guided percutaneous high ligation (FPHL) combined with fluoroscopy-guided foam sclerotherapy (FGFS) to treat varicose veins of the great saphenous veins (GSVs).Materials and MethodsThis was a retrospective study of 113 patients (mean age, 62.1 ± 10.8 years; 60 men) with varicose veins of the GSVs (133 limbs) that were treated with FPHL combined with FGFS between April 1 and October 31, 2019. Demographic and clinical data were collected from these patients before the FPHL procedure, after which FGFS was performed. The preterminal GSV was ligated percutaneously by a percutaneously-positioned polypropylene ligature under fluoroscopic guidance. The outcome of ligation was confirmed by venography. Then, foam sclerotherapy was performed under fluoroscopy. At 1-year follow-up, GSV occlusion was evaluated by ultrasound. The venous clinical severity scores (VCSSs) were compared between the preoperative and 1-year follow-up periods.ResultsThe technical success rate was 100% (133 limbs). Complete 12-month follow-up was available for 112 limbs (84.2%) and 103 of these limbs (92.0%) remained occluded during this period. The VCSS improved from 4.71 ± 2.15 to 0.74 ± 0.60 (V = 6328, P < .001). During follow-up, there were 16 limbs with thrombophlebitis and 38 limbs with saphenous junction pain; these events were alleviated within 2 weeks of the procedure. There was no deep venous thrombosis or other severe adverse events.ConclusionsFPHL combined with FGFS to treat varicose veins in the GSVs achieved an occlusion rate of 92% and improved the clinical symptoms within 1 year; this minimally-invasive procedure was safe and effective. 相似文献
Endoscopies are crucial for detecting and diagnosing diseases in gastroenterology, pulmonology, urology, and other fields. To accurately diagnose diseases, sample biopsies are indispensable and are currently considered the gold standard. However, random 4-quadrant biopsies have sampling errors and time delays. To provide intraoperative real-time microscopic images of suspicious lesions, microscopic endoscopy for in vivo optical biopsy has been developed, including endocytoscopy and confocal laser endomicroscopy. This article reviews recent advances in technology and clinical applications, as well as their shortcomings and future directions. 相似文献
This study aimed at comparing shear-bond strength (SBS) of different self-etching adhesive systems (Clearfil S3 Bond Plus, G-Premio BOND and IBond) to dentin without or with diode-laser irradiation before photo-polymerization and to determine the effect of storage and thermo-cycling on SBS of adhesive systems. Methods: The buccal surface of 84 extracted maxillary premolars was grounded to create flat surface. The specimens were allocated into 3 groups (n = 28) depending upon the adhesive systems, then each group was divided into two sub-group (I, II) (n = 14). After the placement of respective adhesive systems on the flat surface, adhesive system in group I was photo-polymerized immediately, while in group II, the adhesive systems were exposed to diode-laser before photo-polymerization. Composite cylinder (4 mm in diameter and 2 mm height) was built on the flat surface of each specimen. Then group I and II were divided into two sub-groups (n = 7) according to the storage time and thermo-cycling (1 day without thermo-cycling or 72 days with thermo-cycling) then all the specimens were stored in distilled water. The SBS was measured at the end of storage period. ANOVA, Duncan’s Multiple Range Test and independent t-test “P ≤ 0.05” were used for data analysis. Results: G-premio BOND showed the highest mean value of SBS followed by Clearfil S3 Bond plus without significant difference between them, while IBond revealed the least mean value. Laser irradiation had positive effect on the bond-strength of all tested adhesive systems. The results also showed that the storage with thermo-cycling had negative effect on the bond-strength in groups without laser irradiation for all tested adhesive systems, while for groups with laser irradiation, the reduction in the bond-strength of all tested adhesive systems was not significant. Conclusion: Diode-laser application prior to photo-polymerization of self-etch adhesive systems significantly increased the bond-strength to dentin and can increase the durability of composite adhesion. 相似文献
结果:FLACS组术中CDE和EPT明显低于CPCS组(t=8.50、5.16; P<0.01、=0.001)。两组术后抗青光眼药物较术前均明显减少(t=9.12、7.76; P=0.011、0.016),但两组间无差异(t=1.79,P=0.082)。两组术后BCVA均较术前改善,眼压均较术前降低(P<0.05)。FLACS组在术后早期(1d,1wk)BCVA的改善较CPCS组更显著(t=9.74、8.49; P=0.008、0.012),但在术后1、3mo的BCVA改善程度并无不同(t=0.62、0.44; P=1.415、2.021)。CPCS组在术后随访不同时期的角膜内皮细胞损伤较FLACS组更明显(P<0.05)。术后随访的不同时期FLACS组和CPCS组在控制眼压方面无差异(F组间=0.64,P组间=0.421)。FLACS组的手术并发症发生率27%(7/26)较CPCS组89%(24/27)低(χ2=20.95,P<0.01),其中角膜水肿(8% vs 41%)、前囊撕裂(0 vs 11%)在FLACS组中明显低于CPCS组,后囊破裂(0 vs 7%)、玻璃体脱出(0 vs 4%)及人工晶状体偏位(0 vs 7%)也均发生在CPCS组。但两组的治疗总成功率相近(P=28.718)。