Purpose: Beyond promising experimental results of sensory passive stimulations in spatial cognition disorders, some questions still remain regarding interests of these stimulations during the daily activities in neglect. The aim of this case-study was to evaluate the effects of a protocol combining left neck-muscle vibration with daily simple movements, like arm pointing movements, on perceptivo-locomotor deficits in a left spatial neglect patient.
Materials and methods: Two neuropsychological tests, one subjective straight-ahead pointing (SSA) test and one wheelchair navigation test were carried out before the combination protocol, immediately after, 1?h later, and 24?h later.
Results: The results showed a reduction of neglect spatial bias following the protocol lasted at least 24?h in all the tests (except for the SSA test due to the unavailability of the pointing device).
Conclusions: The range of improvements in the symptoms of spatial neglect suggests that this therapeutic intervention based on the combining neck-muscle vibration to voluntary arm movements could be a useful treatment for this condition. One of future investigation axes should be the development of a vibratory tool in order to facilitate the combining this proprioceptive stimulation to daily activities.
Implications for rehabilitation
Spatial neglect is a perplexing neuropsychological syndrome, affecting different domains of spatial cognition and impacting also the functional domain.
The treatments based on neck-muscle vibration are simple to use, non-invasive and requires none active participation of patient.
A therapeutic intervention based on the combining left neck-muscle vibration and voluntary arm movements in a left-spatial-neglect show a lasting reduction of symptoms especially in daily activities.
The combination of treatments based on the Bottom–Up approach opens innovative perspectives in rehabilitation.
PurposeTo investigated the effect of vibratory stimulus on masseter muscles during oral fine motor biting tasks.MethodsSixteen healthy individuals (age: 24.5 ± 2.4 years) participated in experiment I during which the participants were asked to “hold and split” half a roasted peanut placed on a force transducer with their front teeth. The participant performed ten series with ten trials of the “hold and split” behavioral task while vibratory stimulus was applied on the masseter muscle every alternate series. Further, fourteen participants participated (age: 25.2 ± 4.8 years) in experiment II during which they performed a series each of the behavioral task at baseline, an adjusted baseline without and with vibration as well as with and without visual feedback. Hold and split forces along with the variability of hold force and duration and force rate during the split were measured.ResultsThe results of the study showed an increase in the magnitude of the hold force (P = 0.002), force rate during the split (P < 0.001) and a significant decrease in the duration of split (P < 0.001) due to the vibratory stimulus. However, there was no significant effect of the vibratory stimulus on the variability of hold forces (P = 0.879) or mean split force (P = 0.683) during the “hold and split” behavioral task. The results of experiment II also showed an increase in hold force due to the vibratory stimulus (P < 0.001).ConclusionsVibratory stimulus to the masseter muscles impairs the oral force control during a standardized biting task and provide further insight into the sensorimotor regulation of the masticatory system. 相似文献
Acrylamide (ACM) is a high-volume industrial chemical with diverse uses in manufacturing, construction and laboratory research. ACM is a well-established neurotoxic agent causing peripheral neuropathy with impairment in the arms and legs of exposed workers, most thoroughly studied in Swedish tunnel workers exposed to ACM grouting. A quantitative risk assessment was performed to assess ACM risk to workers. Using data from a published paper investigating peripheral neuropathies in Chinese chemical workers, estimates of exposure response for vibration perception threshold and nerve conduction velocities were calculated, based on hemoglobin adducts and air concentrations as exposure metrics. The benchmark dose procedure was applied in order to calculate excess risks of impairment, defined as adverse performance exceeding the 95th percentile in unexposed populations, at various concentrations of airborne ACM exposure. Under the assumptions in this risk assessment, after three years of inhalation exposure at 0.3 mg/m3, the excess attributable impairment manifest in vibration perception and nerve conduction velocity is estimated to occur in 1-2% of workers. For 10 years at 0.3 mg/m3 ACM inhalation (equivalent to 3 years at 1.0 mg/m3) the excess prevalence of impairment would be 2-14% of workers, assuming the effect continues to accrue linearly in time. Using published data, the risks of impairment from peripheral neuropathy attributable to exclusively airborne ACM exposure can be predicted for exposure periods less than 10 years. The risks associated with dermal and airborne ACM exposures can be estimated by characterizing working process environments using ACM Hb-adduct levels and possibly monitored with urinary biomarkers. 相似文献
Solid dispersions of spironolactone with Soluplus® and polyvinylpyrrolidone were prepared by spray drying according to a mixture experimental design and evaluated for moisture content, particle size, drug solubility, crystallinity (powder X-ray diffraction and differential scanning calorimetry), and physicochemical interactions (Fourier-transform infrared spectroscopy, Raman). In vitro dissolution was evaluated for the spray dried product itself and after compression into tablets, and prediction models were derived using multiple linear regression analysis. The spray dried products consisted of amorphous drug, indicated by the absence of crystalline powder X-ray diffraction peaks. Amorphization and interactions impacted changes in the Fourier-transform infrared spectroscopy spectra in the ranges 2900-3000 cm?1 (C-H) and 1600-1800 cm?1 (C=O) and caused merging at 1690 cm?1 (C=O of lactone) and 1670 cm?1 (C=O of thioacetyl group). In the Raman spectra, amorphization and interactions resulted in disappearance of peak at 1690 cm?1 (C=O) and merging of peaks at 582 and 600 cm?1 (C-S). Hydrogen bonding between the thioacetyl group of the drug with the hydroxyl groups of Soluplus® caused marked suppression of the peak at 1190 cm?1 (R-C(=O)-S vibration). Amorphization and interactions resulted in improved solubility and dissolution which was greatest for drug/Soluplus® ratio 1:4 and was also demonstrated in the corresponding tablets. 相似文献
Purpose Reduced cement film thicknesses can improve crown seating and decrease marginal discrepancies. Improved marginal adaptation has the potential to reduce plaque accumulation, periodontal disease, and cement dissolution. Studies have indicated that dynamic seating methods can reduce seating discrepancies associated with zinc phosphate and resin cements. However, other types of cements and other dynamic techniques have not yet been studied or compared, nor has the mechanism for improved seating been fully explained. Therefore, the purpose of this study was to investigate the effect of a variety of loading methods on the film thicknesses of current types of crown and fixed partial denture cements compressed between glass plates. Materials and Methods This study investigated the effect of three dynamic loading methods on film thickness of six representative fixed prosthodontic cements. These included zinc phosphate, resin-modified glass ionomer, encapsulated glass ionomer, adhesive composite resin, composite resin, and polycarboxylate. The method was derived from American Dental Association specifications for cement film thickness. In control groups, the cements were placed between two glass plates and statically loaded with a 15-kg weight. The test groups were initially similarly loaded, and then for 30 seconds further subjected to simulated repeated patient opening and closing, vibrations from an electromallet, or an ultrasonic device. Results Mean film thicknesses ranged from 7.4 μm for polycarboxylate/ultrasound up to 40.3 μm for composite resin/static. Two-way analysis of variance revealed that the effects of material type and cementation method and their interaction all significantly affected film thickness (P < .0001). Multiple range analysis showed that dynamic methods were generally superior to static loading and that the ultrasonic method was the best overall. Conclusions The different dynamic loading methods all significantly decreased cement film thicknesses between glass plates. The ultrasonic method was the most effective. The type of cement used also influenced film thickness. Composite resins were more affected than other materials. 相似文献
BACKGROUND: This study was designed to determine whether or not high-frequency and low-magnitude vibration affects orthodontic tooth movement caused by magnetic or/and mechanical forces. METHODS: Forty-four 7-week-old Wistar rats were randomly divided into four groups, with each group further divided into experimental and control subgroups. Neodymium-Iron-Boron (Nd-Fe-B) magnets and Sentalloy closed coil springs were placed between maxillary or mandibular first molars and incisors to activate tooth movement. The animals of experimental subgroups were exposed to the vibration induced by pulsed electromagnetic fields (PEMF) whilst the control subgroups were under normal atmosphere. The experiment lasted for 14 days and all of the animals were sacrificed for examination. The changes in the space between the molar and incisor were measured to indicate the amount of tooth movement. RESULTS: The coil springs, either with sham or active magnets, move molar much more than magnets alone, regardless of absence or presence of PEMF (p < 0.001). Under PEMF, the coil spring moved significantly more amount of tooth movement than that of coil-magnet combination (p < 0.01), as did the magnets compared to sham magnets (p < 0.019). Under a non-PEMF scenario, there was no significant difference in tooth movement between coil spring and coil-magnets combination, nor was there difference between magnets and sham magnets. CONCLUSIONS: It is suggested that the PEMF-induced vibration may enhance the effect of mechanical and magnetic forces on tooth movement. 相似文献