Hypertonic saline (HTS) has potent immune and vascular effects. We assessed recipient pretreatment with HTS on allograft function in a porcine model of heart transplantation and hypothesized that HTS infusion would limit endothelial and left ventricular (LV) dysfunction following transplantation.
Methods
Heart transplants were performed after 6 hours of cold ischemic storage. Recipient pigs were randomized to treatment with or without HTS (7.5% NaCl) before cardiopulmonary bypass (CPB). Using a myograft apparatus, coronary artery endothelial-dependent (Edep) and -independent (Eind) relaxation was assessed. LV performance was determined using pressure-volume loop analysis. Pulmonary interleukin (IL)-2, IL-6, and tumor necrosis factor (TNF)-α expression was measured.
Results
Weaning from CPB and LV performance after transplantation were improved in HTS-treated animals. Successful weaning from CPB was greater in the HTS-treated hearts (8 of 8 vs 2 of 8; P < .05). Mean LV functional recovery was improved in the HTS-treated animals, as assessed by preload recruitable stroke work (65 ± 10% vs 27 ± 10%; P < .001) and end-systolic elastance (55 ± 7% vs 37 ± 4%; P < .001). Treatment with HTS resulted in improved Edep (mean maximum elastance [Emax], 56 ± 5% vs 37 ± 7%; P < .001) and Eind (mean Emax%, 77 ± 6% vs 52 ± 4%; P < .001) vasorelaxation compared with control. Pulmonary expression of IL-2, IL-6, and TNF-α increased following transplantation, whereas HTS therapy attenuated IL production (P < .001). Transplantation increased plasma TNF-α levels and LV TNF-α expression, whereas HTS prevented this up-regulation (P < .001).
Conclusions
Recipient HTS pretreatment preserves allograft vasomotor and LV function, and HTS therapy limits CPB-induced injury. HTS may be a novel recipient intervention to prevent graft dysfunction. 相似文献
The inflammatory response induced by cardiopulmonary bypass decreases vascular tone, which in turn can lead to vasoplegic syndrome. Indeed the hypotension consequent to on-pump cardiac surgery often necessitates vasopressor and intravenous fluid support. Methylene blue counteracts vasoplegic syndrome by inhibiting the formation of nitric oxide.We report the use of methylene blue in a 75-year-old man who developed vasoplegic syndrome after cardiac surgery. After the administration of methylene blue, his hypotension improved to the extent that he could be weaned from vasopressors. The use of methylene blue should be considered in patients who develop hypotension refractory to standard treatment after cardiac surgery. 相似文献
Depressive disorder is characterized by a polymorphic symptomatology associating emotional, cognitive and behavioral disturbances. One of the most specific symptoms is negative beliefs, called congruent to mood. Despite the importance of these beliefs in the development, the maintenance, and the recurrence of depressive episodes, little is known about the processes underlying the generation of depressive beliefs. In this paper, we detail the link between belief updating mechanisms and the genesis of depressive beliefs. We show how depression alters information processing, generating cognitive immunization when processing positive information, affective updating bias related to the valence of belief and prediction error, and difficultie to disengage from negative information. We suggest that disruption of belief-updating mechanisms forms the basis of belief-mood congruence in depression. 相似文献
Motion is a major confound in diffusion‐weighted imaging (DWI) in the body, and it is a common cause of image artefacts. The effects are particularly severe in cardiac applications, due to the nonrigid cyclical deformation of the myocardium. Spin echo‐based DWI commonly employs gradient moment‐nulling techniques to desensitise the acquisition to velocity and acceleration, ie, nulling gradient moments up to the 2nd order (M2‐nulled). However, current M2‐nulled DWI scans are limited to encode diffusion along a single direction at a time. We propose a method for designing b‐tensors of arbitrary shapes, including planar, spherical, prolate and oblate tensors, while nulling gradient moments up to the 2nd order and beyond. The design strategy comprises initialising the diffusion encoding gradients in two encoding blocks about the refocusing pulse, followed by appropriate scaling and rotation, which further enables nulling undesired effects of concomitant gradients. Proof‐of‐concept assessment of in vivo mean diffusivity (MD) was performed using linear and spherical tensor encoding (LTE and STE, respectively) in the hearts of five healthy volunteers. The results of the M2‐nulled STE showed that (a) the sequence was robust to cardiac motion, and (b) MD was higher than that acquired using standard M2‐nulled LTE, where diffusion‐weighting was applied in three orthogonal directions, which may be attributed to the presence of restricted diffusion and microscopic diffusion anisotropy. Provided adequate signal‐to‐noise ratio, STE could significantly shorten estimation of MD compared with the conventional LTE approach. Importantly, our theoretical analysis and the proposed gradient waveform design may be useful in microstructure imaging beyond diffusion tensor imaging where the effects of motion must be suppressed. 相似文献
Immune checkpoint inhibitors (ICIs) have proved to be groundbreaking in the field of oncology. However, immune system overactivation from ICIs has introduced a novel medical entity known as immune-related adverse events (irAEs), that can affect any organ or tissue. ICI-induced inflammatory arthritis (ICI-IIA) is the most common musculoskeletal irAE and can lead to significant morbidity and limitation in anti-cancer therapy. 相似文献
Background: High-quality adverse drug reaction (ADR) reports are essential for conducting drug safety monitoring in pharmacovigilance. The study aim was to assess the current quality of ADR reports in western China, and to identify problems with ADR report quality.
Research design and methods: A sample of 1139 reports received by the Shaanxi ADR Monitoring Center from January 2015 to December 2017 was selected. ADR report quality was evaluated using an ADR report quality evaluation system.
Results: None of the reports were rated as excellent and 1.40% (n = 16) as good. Report quality was better for new and serious reports than for general reports. Medical institutions generated higher quality reports than pharmaceutical manufacturers. Nurses generated higher quality reports than doctors, pharmacists, and other professionals. Reporters of different occupations showed significant differences in the quality of the indicators Reporting time limit, Intervention ADR time, ADR termination time, ADR intervention measures, Original disease, and Cause of medication (P = 0.000).
Conclusions: The ADR data quality was poor in western China, and of lower quality than reported data from previous research in other regions. Improvements in the quality and availability of ADR reports are urgently needed. 相似文献