Women with pre-eclampsia have an increased risk of cardiovascular disease later in life. The aim of the study was to establish the presence and pattern of arterial stiffness in women previously with pre-eclampsia from a semi-rural region of South Africa. This was a prospective longitudinal study which involved 36 previously pre-eclamptic women and 86 non-pregnant controls (NPC) who had a past history of non-complicated pregnancy. Maternal wave reflection (augmentation index) and carotid-femoral pulse wave velocity were assessed noninvasively, using applanation tonometry with the SphygmoCor device. Endothelial function was assessed by EndoPAT 2000 device; pneumatic probes were fitted to the index fingers; induced flow-mediated reactive hyperemia; the ratio of the readings before and after occlusion was then used to calculate the score, the reactive hyperemia index (RHI) as a measure of endothelial function.
Pulse wave velocity remained significantly higher in previously pre-eclamptic women than non-pregnant controls up to three months after delivery (p < 0.05), then it reduced to nonsignificant values. All blood pressure indices (central and brachial pressures), were higher in previously pre-eclamptic women as compared to nonpregnant controls up to one year postpartum.
Regional (aortic) arterial stiffness, though it persists for some time after delivery, is transitory in previously pre-eclamptic women from the rural Africa setting. However, their increase blood pressure is an indication of compromised arterial compliance in women previously with pre-eclampsia. 相似文献
Motion is a major confound in diffusion‐weighted imaging (DWI) in the body, and it is a common cause of image artefacts. The effects are particularly severe in cardiac applications, due to the nonrigid cyclical deformation of the myocardium. Spin echo‐based DWI commonly employs gradient moment‐nulling techniques to desensitise the acquisition to velocity and acceleration, ie, nulling gradient moments up to the 2nd order (M2‐nulled). However, current M2‐nulled DWI scans are limited to encode diffusion along a single direction at a time. We propose a method for designing b‐tensors of arbitrary shapes, including planar, spherical, prolate and oblate tensors, while nulling gradient moments up to the 2nd order and beyond. The design strategy comprises initialising the diffusion encoding gradients in two encoding blocks about the refocusing pulse, followed by appropriate scaling and rotation, which further enables nulling undesired effects of concomitant gradients. Proof‐of‐concept assessment of in vivo mean diffusivity (MD) was performed using linear and spherical tensor encoding (LTE and STE, respectively) in the hearts of five healthy volunteers. The results of the M2‐nulled STE showed that (a) the sequence was robust to cardiac motion, and (b) MD was higher than that acquired using standard M2‐nulled LTE, where diffusion‐weighting was applied in three orthogonal directions, which may be attributed to the presence of restricted diffusion and microscopic diffusion anisotropy. Provided adequate signal‐to‐noise ratio, STE could significantly shorten estimation of MD compared with the conventional LTE approach. Importantly, our theoretical analysis and the proposed gradient waveform design may be useful in microstructure imaging beyond diffusion tensor imaging where the effects of motion must be suppressed. 相似文献
Coronary flow reserve (CFR) has been used toassess coronary microcirculation and epicardial coro-nary stenoses[1— 3 ] . CFR is defined as the ratio ofcoronary flow under maximal coronary vasodilatationto coronary flow under resting conditions[4 ] .Whenthe cross- sectional area of epicardial coronary arteriesis constant,coronary flow velocity (CFV) ratios areequal to volume flow ratios.The most common method used clinically formeasuring CFVR is intracoronary Doppler flow(ICD) analysis re… 相似文献
BACKGROUND: Visual motion processing is compromised in schizophrenia, as shown in deficient velocity discrimination. Processing of motion signals comprises progressive stages along the geniculate-striate-extrastriate-cortex pathway. Based on neurophysiologic and brain lesion studies, a velocity discrimination deficit can implicate early-stage motion processing if it is contrast-dependent or late-stage motion processing if it is contrast-independent. METHODS: To determine which stage underlies the deficient velocity discrimination in schizophrenia, we examined the effects of visual contrast on velocity discrimination. We measured velocity discrimination thresholds in schizophrenia patients (n = 34) and normal control subjects (n = 17) at both low and high contrasts, using each subject's contrast detection threshold to equate contrast levels. RESULTS: Schizophrenia patients showed poor velocity discrimination that improved little with high contrast, whereas normal control subjects showed enhanced velocity discrimination with increased contrast. CONCLUSIONS: The finding that the velocity discrimination deficit in schizophrenia is independent of contrast modulation implicates the later, rather than the earlier, stages of motion processing, which is mediated in the extrastriate cortex. 相似文献
The study aimed to compare the longitudinal assessment of autonomic nerve function by computerized infrared pupillometry and standard cardiovascular tests in adolescents with diabetes. Adolescents (n = 150) were assessed at two time points (T1 and T2). The median time interval between assessments was 1.5 (range 0.9–3) years. At T1 the median age was 14.5 (range 8.3–19.5) years and the median duration was 6.5 (range 1.1–16) years. The pupillary variables assessed included the resting pupil diameter, the maximum constriction velocity, and the reflex amplitude of constriction. Heart rate reflexes were assessed in response to deep breathing, the Valsalva manoeuvre, and on standing from a lying position (30/15 ratio). Between visits there was a significant decrease in maximum constriction velocity (6.0 mm s?1 vs 6.3 mm s?1, p = 0.0001) and resting pupil diameter (6.2 mm vs 6.3 mm, p = 0.001). At reassessment pupillary abnormalities increased from 32 (21 %) to 45 (30%), with 17 (54 %) of the initial abnormalities persisting. Adolescents with abnormally slow maximum constriction velocity compared to those with normal maximum constriction velocity had a higher glycated haemoglobin (HbA1c%) at T2 (p = 0.02) and between assessments (p = 0.01). Cardiovascular test abnormalities did not increase between visits and the persistence of initial abnormalities was low (21 %). In summary, pupillometry appears a more sensitive test of autonomic nerve dysfunction in adolescents with diabetes than assessment of cardiovascular reflexes. 相似文献
Smooth pursuit typically includes corrective catch-up saccades, but may also include such intrusive saccades away from the
target as anticipatory or large overshooting saccades. We sought to differentiate catch-up from anticipatory and overshooting
saccades by their peak velocities, to see whether the higher velocities of visually rather than nonvisually guided saccades
in saccadic tasks may be found also in saccades in pursuit. In experiment 1, 12 subjects showed catch-up, anticipatory, and
overshooting saccades to comprise 70.4% of all saccades in pursuit of periodic, 30°/s constant-velocity targets. Catch-up
saccades were faster than the others. Saccadic tasks were run as well, on 19 subjects, including the 12 whose pursuit data
were analyzed, with target-onset, target-remaining (saccade to the remaining target when the other three extinguish), and
antisaccade tasks. For 17 of the 19 subjects, antisaccade velocities were lower than for either target-onset or target-remaining
tasks. Velocities for the target-remaining task were near those for target onset, indicating that target presence, not its
onset, defines visually guided saccades. Error and reaction-time data suggest greater cognitive difficulty for target remaining
than for target onset, so that the cognitive difficulty of typical nonvisually guided saccade tasks is not sufficient to produce
their lowered velocity. To produce reliably, in each subject, catch-up and anticipatory saccades with comparable amplitude
distributions, nine new subjects were asked in experiment 2 to make intentional catch-up and anticipatory saccades in pursuit,
and were presented with embedded target jumps to elicit catch-up saccades, all with periodic target trajectories of 15°/s
and 30°/s. Velocities of intentional anticipatory saccades were lower than velocities of intentional catch-up saccades, while
velocities of intentional and embedded catch-up saccades were similar. Target-onset and remembered-target saccadic tasks were
run, showing the expected higher velocity for the target-onset task in each subject. Both experiments demonstrate higher peak
velocities for catch-up saccades than for anticipatory saccades, suggesting that cortical structures preferentially involved
in nonvisually guided saccades may initiate the anticipatory and overshooting saccades in pursuit.
Received: 1 December 1995 / Accepted: 25 February 1997 相似文献
The CellSoft computer-assisted sperm analysis system was evaluated as to the optimal setting of three components of the internal running conditions. These 'set up' parameters were the lower setting for cell size range (PIXMIN), threshold velocity (MINVEL) and maximum velocity (MAXVEL). The decision for the PIXMIN setting was founded on observed sizes of sperm with low instant velocities combined with a study of the relationship between false positive observations for sperm and the PIXMIN setting. Our recommendation for this setting is three pixels. From the observation that 97.5% of immobilized sperm exhibit instant velocities of less than 15 microns sec-1, this is our proposal for the MINVEL setting. Correspondingly, the 97.5 percentile for instantaneous velocities in a population of some 14,000 cells (30 men with type 'a' motility, WHO) was 168 microns sec-1. We recommend that MAXVEL be set at this limit. Alternative settings for both MINVEL and MAXVEL are presented as some users may wish to apply other percentiles. From the above results a setting for PIXMAX at 25 pixels could be inferred. We recommend that these settings be applied in semen laboratories analysing human native samples at room temperature. 相似文献