Four patients, who received epidural blood patch to treat postdural puncture headache, were examined with computed tomography in order to demonstrate the distribution of the injected blood. Blood alone could not be identified, but adding 2 ml contrast agent Iohexol 180 mg J/ ml (Omnipaque®, Nycomed Imaging) to 18 ml blood gave an excellent demonstration of the distribution of the blood in the epidural space, both cranio-caudally (7–14 segments) and spatially in relation to the epidural septae. The blood-contrast media had a strong affinity to the dural sac. There was no support of the spacefilling effect of blood patch. 相似文献
Study Objective: To test the hypothesis that slow administration of local anesthetic into the epidural space by gravity flow reduces the incidence of signs and symptoms of unintended injection.
Design: Prospective, randomized study.
Setting: Teaching hospital.
Patients: 600 ASA physical status I and II parturients scheduled for labor and delivery or elective cesarean section.
Interventions: After identification of the epidural space with pulsations of an air-fluid column, parturients for vaginal delivery (n = 380) were randomized to receive a test dose of 3 ml 3% 2-chloroprocaine with epinephrine 20 μg, two doses of 7 ml bupivacaine 0.03 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow (Group 1) given over 30 seconds or by bolus injection (Group 2) given over 5 seconds through the epidural needle; parturients for Cesarean delivery (n = 220) were randomized to receive a test dose and two doses of 6 ml lidocaine 2 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow or by bolus injection through the epidural needle. Changes in maternal heart rate (HR) and blood pressure, signs of intravascular injection, and adverse effects of epidural bupivacaine-sufentanil were recorded after each dose.
Measurements and Main Results: Gravity flow administration (Group 1) was associated with a smaller increase in mean maternal HR (p < 0.001), less hypotension (p < 0.01), sedation (p < 0.01), nausea (p = 0.01), and segmental spread (p < 0.0001) than were corresponding doses given by traditional bolus injection (Group 1) for vaginal or Cesarean deliveries. The incidence of systemic toxicity was zero of 300 (0%) with gravity flow and 4 of 300 (1.3%) by bolus injection, p = 0.12, Fisher's exact test. No patient in either group had an accidental intrathecal injection.
Conclusion: Gravity flow administration of local anesthetic-opioid solution during epidural block for obstetrics was associated with fewer signs of systemic drug absorption and cardiovascular perturbations than was the traditional bolus injection. This study supports the current opinion that slow administration of local anesthetic during epidural black contributes to fewer adverse events. 相似文献
In 10 patients subjected to craniotomy for supratentorial cerebral tumours in neurolept anaesthesia, cerebral blood flow (CBF) and cerebral metabolic rate of oxygen (CMRO2) were measured twice peroperatively by a modification of the Kety & Schmidt technique, using 133Xe. The relative CO2 reactivity was assessed indirectly as the % change of the arteriovenous oxygen difference (AVDO2) per mm change in PaCO2. The patients were premedicated with diazepam 10-15 mg perorally. For induction, thiopentone 4-6 mg/kg, droperidol 0.2 mg/kg and fentanyl 5 micrograms/kg were used, and for maintenance N2O 67% and fentanyl 4 micrograms/kg/h. During the first flow measurement the median and range of CBF was 30 ml/100 g/min (range 17-45), of AVDO2 8.0 vol % (range 4.1-9.5), and of CMRO2 2.28 ml O2/100 g/min (range 1.57-2.84). During the second CBF study, AVDO2 increased to 9.3 vol % (range 3.4-11) (P less than 0.05), and CMRO2 increased to 2.51 ml O2/100 g/min (range 1.88-3.00) P less than 0.05, while CBF was unchanged. The CO2 reactivity was present in all studies, median 1.8%/mmHg (range 0.5-15.1). The correlation coefficients between jugular venous oxygen tension/saturation, respectively, and CBF were high at tensions/saturations exceeding 4.0 kPa and 55%, indicating that hyperperfusion is easily unveiled by venous samples from the jugular vein during this anaesthesia. 相似文献
The effects of two H2-receptor antagonists, famotidine and cimetidine, on the plasma levels of epidurally administered lignocaine were studied. Group A (n = 20) received famotidine 20 mg orally the night before surgery and 20 mg intramuscularly 60 minutes before induction of anaesthesia. Group B (n = 15) received cimetidine 200 mg orally the night before the surgery and 400 mg orally 60 minutes before the anaesthetic induction. Group C (n = 20) received neither famotidine nor cimetidine and served as controls. Twelve millilitres of 2.0% lignocaine with adrenaline 1:200,000 was injected into the epidural space in all patients, after the establishment of general anaesthesia with nitrous oxide, oxygen, and enflurane (0.3-0.5%). The patients who received cimetidine showed significantly higher plasma concentrations of lignocaine compared with either group A or group C at all investigation times (p less than 0.01). The mean peak plasma concentrations were 2.4 (SEM 0.1), 3.2 (SEM 0.2) and 2.3 (SEM 0.1) micrograms/ml in group A, B, and C, respectively. This study suggests that famotidine is preferable to cimetidine for control of gastric acidity before the use of lignocaine as the epidural anaesthetic. 相似文献
Forty patients agreed to participate in a study to compare whether fentanyl or alfentanil used as analgesic is associated with quicker recovery following anaesthesia for outpatient arthroscopy procedure. Psychomotor tests including choice reaction time (CRT), perceptive accuracy test (PAT) and finger tapping test (FTT) were done prior to induction of anaesthesia with propofol (2–3 mg–kg-1). Patients were then divided into two groups: Group F (fentanyl) received 0.1 mg fentanyl prior to start of surgery and thereafter 0.05 mg every 30 min during the procedure. Group A (alfentanil) received 0.5 mg alfentanil prior to the onset of surgery and 0.25 mg every 15 min thereafter. Anaesthesia was then maintained using isoflurane (0.5–2%) in oxygen and air (Fio2 0.33) during spontaneous respiration with a face mask in a Bain's system. Psychomotor tests were repeated every 45 min postoperatively. Clinical recovery, visual analogue pain intensity score (VAS) and time to discharge home were also assessed by a nurse blind to the method used. Patients in Group A returned to baseline values on the FTT after 90 min while those in Group F did not return to baseline values until 135 min after the end of the operation. Clinical recovery and time to discharge home ("home ready") were also significantly longer in Group F. There was no difference in recovery as seen in the PAT and CRT between the groups. Also, there was no difference in the incidence of side effects and the pain intensity (VAS) scores were similar in the two groups at all time periods. We conclude that recovery following alfentanil is quicker compared to fentanyl when anaesthesia is based on isoflurane. 相似文献
A double-blind randomised study was performed to assess the value of the addition of pethidine 50 mg to the initial dose of bupivacaine given for epidural analgesia in labour. Forty-nine patients received either 1 ml of saline (n = 24), or 50 mg of pethidine (n = 25), added to 9 ml of 0.25% bupivacaine as an initial injection for intrapartum epidural analgesia. There was a significant increase in the mean duration of analgesia in the pethidine group. However, pethidine did not increase the speed of onset of analgesia, or improve the quality of analgesia. 相似文献