Background: Previous genome-wide association study (GWAS) has revealed the association between MYP10 at 8p23 and MYP15 at 10q21.1 and high myopia (HM) in a French population. This study is managed to discover the connection between some single nucleotide polymorphism (located at MYP10 and MYP15) and Han Chinese HM.
Methods and Results: This case-control association study contained 1673 samples, including 869 ophthalmic patients and 804 controls. Twelve tag SNPs have been selected from the MYP10 and MYP15 loci and genotyped by SNaPshot method. Among 12 SNPs, rs4840437 and rs6989782 in TNKS gene were found significant association with HM. Carriers of rs4840437G allele and rs4840437GG genotype created a low risk of high myopia (P = .036, OR = 0.81, 95%CI = 0.71–0.93; P = .016, OR = 0.73, 95%CI = 0.56–0.96; respectively). Carriers of rs6989782T allele and rs6989782TT+CT genotype also had a decreased risk of high myopia (P = .048, OR = 0.82, 95%CI = 0.71–0.94; P = .006, OR = 0.74, 95%CI = 0.59–0.92; respectively). Other 10 SNPs displaced nonsignificant association with HM. Additionally, the risk haplotype AC and the protective haplotype GT, generated by two SNPs in TNKS, were considerably more likely to be association with HM (for AC, P = .002 and OR = 1.26; for GT, P = .027 and OR = 0.84).
Conclusions: Our results demonstrated that some heritable variants in the TNKS gene are associated with HM in the Han population. The possible functions of TNKS in the development and pathogenesis of hereditary high myopia still require further researches to identify. 相似文献
The purpose of this study was to elucidate the involvement of Mate1 in the tubular secretion of trimethoprim and saturation of Mate1-mediated efflux to address the mechanisms underlying the pharmacokinetic drug interactions with trimethoprim. Trimethoprim is a more potent inhibitor of MATE2-K than MATE1 with Ki values (μM) of 0.030–0.28 and 2.4–5.9, respectively. Trimethoprim is a substrate of human MATE1 and MATE2-K with Km values of 2.3 ± 0.9 and 0.018 ± 0.004 μM, and mouse Mate1, but not human OCT2, mouse Oct1 and Oct2. Pyrimethamine significantly reduced the renal clearance (CLR) of trimethoprim (mL/min/kg) from 40.0 ± 5.1 to 20.1 ± 3.7 (p < 0.05). Trimethoprim was given to mice at three infusion rates (150, 500, and 1500 nmol/min/kg). Together with an increase in the plasma concentrations of trimethoprim, the CLR (mL/min/kg) of trimethoprim decreased to 25.9 ± 3.2, 13.5 ± 5.7, and 8.92 ± 1.50 at the respective rates. Trimethoprim decreased the CLR of rhodamine 123 in an infusion rate-dependent manner: 11.5 ± 1.3 (control), 5.17 ± 1.55, 1.31 ± 0.50, and 0.532 ± 0.180. These results suggest that Mate1 mediates the tubular secretion of trimethoprim, and at therapeutic doses, MATEs-mediated efflux can be saturated, and thereby, cause drug interactions with other MATE substrates. 相似文献
Fetal activity parameters such as movements, heart rate and the related parameters are essential indicators of fetal wellbeing, and no device provides simultaneous access to and sufficient estimation of all of these parameters to evaluate fetal health. This work was aimed at collecting these parameters to automatically separate healthy from compromised fetuses. To achieve this goal, we first developed a multi-sensor–multi-gate Doppler system. Then we recorded multidimensional Doppler signals and estimated the fetal activity parameters via dedicated signal processing techniques. Finally, we combined these parameters into four sets of parameters (or four hyper-parameters) to determine the set of parameters that is able to separate healthy from other fetuses. To validate our system, a data set consisting of two groups of fetal signals (normal and compromised) was established and provided by physicians. From the estimated parameters, an instantaneous Manning-like score, referred to as the ultrasonic score, was calculated and was used together with movements, heart rate and the associated parameters in a classification process employing the support vector machine method. We investigated the influence of the sets of parameters and evaluated the performance of the support vector machine using the computation of sensibility, specificity, percentage of support vectors and total classification error. The sensitivity of the four sets ranged from 79% to 100%. Specificity was 100% for all sets. The total classification error ranged from 0% to 20%. The percentage of support vectors ranged from 33% to 49%. Overall, the best results were obtained with the set of parameters consisting of fetal movement, short-term variability, long-term variability, deceleration and ultrasound score. The sensitivity, specificity, percentage of support vectors and total classification error of this set were respectively 100%, 100%, 35% and 0%. This indicated our ability to separate the data into two sets (normal fetuses and pathologic fetuses), and the results highlight the excellent match with the clinical classification performed by the physicians. This work indicates the feasibility of detecting compromised fetuses and also represents an interesting method of close fetal monitoring during the entire pregnancy. 相似文献
ObjectiveTo examine the effectiveness of a nurse-led multidisciplinary self-management program (NMSP) on self-management behaviors, self-efficacy, health-related quality of life (HRQoL) and unplanned health service utilization (HSU) among Chinese patients with coronary heart disease (CHD) in communities.MethodsA randomized controlled trial with repeated measurements was used. A convenience sample of 144 participants was recruited from a community health center in China. All participants were randomly assigned to an intervention group (n = 72) in the newly developed NMSP or a control group (n = 72) in routine care. Outcome measurement was performed at baseline, 3 months and 6 months using Coronary Artery Disease Self-Management Scale (CADSs), Self-efficacy for Chronic Disease 6-item Scale (SECD6), and Short Form-12 health survey questionnaire (SF-12).ResultsOver the six months, the two groups reported significant differences in disease medical and emotional management of CADSs, confidence in symptom and disease management of SECD6, physical and mental component summary of SF-12, as well as emergency and outpatient visits of unplanned HSU.ConclusionsThe NMSP improves self-management behaviors, self-efficacy, HRQoL and reduces unplanned HSU among CHD patients in communities.Practice implicationsThis study provides an effective approach to empower CHD patients with emphasizing on collaboration support of health professionals in communities. 相似文献
ObjectiveClinical outcomes of 500 high-intensity focused ultrasound (HIFU)-treated uterine fibroids and adenomyosis are analyzed and presented.Materials and methodsThis is a retrospective cross-sectional analysis from a single tertiary medical center. From April 2015 to October 2018, 546 cases were enrolled for the study. After excluding 46 patients with less than 3 months of follow-up period, there were 404 fibroids, 149 adenomyosis and 53 mixed conditions entered for analysis. The patients’ uterine fibroids and adenomyosis were treated by HIFU according to Chongqing Haifu protocol, with 12 cm diameter transducer of focal length 10–16 cm at 0.8 or 1.6 MHz T2-weight MRI imaging was rendered prior to and 3 month post treatment to assess lesion volume change using non-perfusion volume, which was the primary outcome. Secondary outcomes including quality of life, subjective satisfaction, adverse events and pregnancy rate were determined using self-reported questionnaires. The mean follow up period ranged from 3 to 38 months with an average of 21 months.ResultsThree months after HIFU-treated uterine fibroids and adenomyosis, the lesion size reduced 40.2% and 46.3%, respectively. Symptoms all improved with better quality of life for the fibroid group, while those with adenomyosis or combined diseases benefit the most from pain control. Serum CA125 decreased significantly for all studied groups, and LDH only showed improvement for fibroids group. Number of adverse events is comparable to Chongqing data (approximately 10.2%), with mostly mild and self-resolving conditions. No permanent sequelae or death was documented. Twelve pregnancies are reported in this cohort.ConclusionHIFU is safe and effective in treating uterine fibroids and adenomyosis. The results are reproducible if standardized treatment schedules are followed. It is a promising treatment alternative with the advantages of precision, non-invasiveness, rapid recovery and readiness for pregnancy. 相似文献