A national conference on organ donation after cardiac death (DCD) was convened to expand the practice of DCD in the continuum of quality end-of-life care. This national conference affirmed the ethical propriety of DCD as not violating the dead donor rule. Further, by new developments not previously reported, the conference resolved controversy regarding the period of circulatory cessation that determines death and allows administration of pre-recovery pharmacologic agents, it established conditions of DCD eligibility, it presented current data regarding the successful transplantation of organs from DCD, it proposed a new framework of data reporting regarding ischemic events, it made specific recommendations to agencies and organizations to remove barriers to DCD, it brought guidance regarding organ allocation and the process of informed consent and it set an action plan to address media issues. When a consensual decision is made to withdraw life support by the attending physician and patient or by the attending physician and a family member or surrogate (particularly in an intensive care unit), a routine opportunity for DCD should be available to honor the deceased donor's wishes in every donor service area (DSA) of the United States. 相似文献
Background: Remifentanil is commonly used to replace nitrous oxide in general anesthesia to avoid the side effects of the latter. However, there are reports that intraoperative remifentanil infusion can lead to acute opioid tolerance. In this study, the authors tried to determine the dose of remifentanil comparable in efficacy to 70% nitrous oxide and to evaluate its effect on postoperative pain and morphine consumption after colorectal surgery using isoflurane anesthesia.
Methods: Sixty adult patients undergoing open colorectal surgery were randomly assigned to receive either remifentanil or 70% nitrous oxide along with isoflurane anesthesia. After morphine analgesia titration in the postanesthesia care unit, patient-controlled analgesia was commenced. Morphine consumption and pain were scored at rest and during cough or movement for 24 h.
Results: The mean remifentanil infusion rate was 0.17 [mu]g [middle dot] kg-1 [middle dot] min-1. The median visual analog pain score on arrival in the postanesthesia care unit was 1 (0-10) in the nitrous oxide group and 3 (0-9) in the remifentanil group (P < 0.05). Otherwise, there was no difference in pain scores at 5, 10, and 15 min and no difference in the total morphine consumption during the stay in the postanesthesia care unit. The two groups had similar total morphine consumption in the first 24 h and pain scores at rest and during movement. The incidence of postoperative nausea and vomiting was 10% in both groups. There was no difference in the sedation scores. 相似文献
OBJECTIVE: The authors describe their experience with left ventricular assist-device (LVAD) recipients undergoing noncardiac surgery and delineate surgical, anesthetic, and logistic factors important in the successful intraoperative management of these patients. SUMMARY BACKGROUND DATA: Left ventricular assist-devices have become part of the armamentarium in the treatment of end-stage heart failure. As the numbers of patients chronically supported with long-term implantable devices grows, general surgical problems that are commonly seen in other hospitalized patients are becoming manifest. Of particular interest is the intraoperative management of patients undergoing elective noncardiac surgical procedures. METHODS: The anesthesia records and clinical charts were reviewed for eight ventricular assist-device recipients undergoing general surgical procedures between August 1, 1990 and August 31, 1994. RESULTS: A total of 12 procedures were performed in 6 men and 2 women averaging 52.7 years of age. Mean time elapsed from device implantation to operation was 68 +/- 35 days. Conventional inhalational and intravenous anesthetic techniques were well tolerated in these patients undergoing diverse surgical procedures. No perioperative mortality was observed. Five of eight patients went on to successful cardiac transplantation. CONCLUSIONS: Hemodynamic recovery after LVAD insertion has defined a new group of patients who develop noncardiac surgical problems often seen in other critically ill patients. Recognition of the unique potential problems that the LVAD recipient may encounter in the perioperative period--in particular patient positioning, device limitations, and fluid and inotropic management--will ensure an optimal surgical outcome for LVAD recipients undergoing noncardiac surgery. 相似文献
The Depression Scale (DEPS), a new screening instrument for detecting depression in primary health care, was compared with the Hamilton Depression Scale (HDS) among 50 suicide attempters. Using the HDS as a gold standard, the positive and negative predictive values of the DEPS for the diagnosis of depression were 98% and 20%, respectively. The correlation between the total HDS scores and the total DEPS scores was 0.60. The DEPS may help general practitioners to detect depression among suicide attempters, but it should not be used to exclude depression. 相似文献
OBJECTIVE: The efficacy for primary orthotopic liver transplantation of a new immunosuppressive agent, FK 506 (tacrolimus, Prograf, Fujisawa USA, Deerfield, IL), was determined. SUMMARY BACKGROUND DATA: After 3 years of preclinical research, a clinical trial of FK 506 for orthotopic liver transplantation was begun in February 1989, first as a rescue therapy for patients with intractable rejection with conventional immunosuppression, then as a primary drug. METHODS: Between August 1989 and December 1993, 1391 recipients (1188 adult and 203 pediatric) of primary liver allografts were treated with FK 506 from the outset. Results from these patients were analyzed and compared with those of 1212 historical control patients (971 adult and 241 pediatric) given cyclosporine-based immunosuppression. RESULTS: Actuarial survival at 4 years was 86.2% with FK 506 versus 65.5% with cyclosporine in the pediatric patients (p < 0.0000) and 71.4% versus 65.5% in the adults (p < 0.0005). The need for retransplantation was reduced significantly for FK 506 patients. Four-year graft survival was 77.0% with FK 506 versus 48.4% with cyclosporine in the pediatric patients (p < 0.0000), and 61.9% with FK 506 versus 51.4% with cyclosporine in the adult recipients (p < 0.0000). Regression analysis revealed that reduction in mortality or graft loss from uncontrollable rejection, sepsis, technical failure, and recurrent original liver disease were responsible for the improved results with FK 506 therapy. CONCLUSIONS: FK 506 is a potent and superior immunosuppressive agent for orthotopic liver transplantation. 相似文献
Cytotoxic T lymphocytes (CTL) recognize antigens derived from endogenously expressed proteins presented on the cell surface in the context of major histocompatibility complex (MHC) class I molecules. Because CTL are effective in antiviral and antitumor responses, the delivery of antigens to the class I pathway has been the focus of numerous efforts. Generating CTL by immunization with exogenous proteins is often ineffective because these antigens typically enter the MHC class II pathway. This review focuses on the usefulness of bacterial toxins for delivering antigens to the MHC class I pathway. Several toxins naturally translocate into the cytosol, where they mediate their cytopathic effects, and the mechanisms by which this occurs has been elucidated. Molecular characterization of these toxins identified the functional domains and enabled the generation of modified proteins that were no longer toxic but retained the ability to translocate into the cytosol. Thus, these modified toxins could be examined for their ability to carry peptides or whole proteins into the cytosolic processing pathway. Of the toxins studied—diphtheria, pertussis, Pseudomonas, and anthrax—the anthrax toxin appears the most promising in its ability to deliver large protein antigens and its efficiency of translocation. 相似文献
ABSTRACT: Pemphigus vulgaris (PV) is an autoimmune disease of the skin and mucous membranes characterized by an autoantibody response against an epidermal cadherin. We performed high resolution HLA class II typing in 19 patients with PV from Rawalpindi, Pakistan and 19 non-Jewish European PV patients from Boston by sequence-specific oligonucleotide probe hybridization. The results were compared with two separate ethnically matched control populations. We found that PV patients from Pakistan had significantly increased frequencies of DRB1*1404 ( p = 0.01), DQA1*0101 ( p = 0.02), and DQB1*0503 ( p = 0.01). Among the patients of non-Jewish European ancestry, DRB1*1401 ( p < 10−6), DQA1*0101 ( p < 10−5) and DQB1*0503 ( p < 10−6), were increased in PV patients. Formal linkage analysis between the major histocompatibility complex and the PV antibody was performed in 67 relatives of the 19 Pakistani patients. The results showed strong evidence for linkage of HLA-DRB1*1404, DQA1*0101, DQB1*0503, with the presence of PV antibody in relatives’ families with a significant logarithm of the odds score of 6.06. Based on the three dimensional structure of class II molecules, we propose that HLA-DQA1*0101 and DQB1*0503, encode a negatively charged P9 peptide binding pocket of the DQ molecule and are significantly associated with susceptibility to PV in non-Jewish populations. 相似文献
A Multiskan photometer for reading microtiter plate enzyme immunoassays was linked with a time sharing computer to facilitate control of assay variation and analysis of results. The interface that converted photometer output to RS-232-C format required changes to divide the output into segments short enough for input to the computer. To measure within-plate variation and investigate how the method of allocating sample duplicates to plate wells may affect the estimation of sample variance, uniformity tests were conducted with 47 plates. Coefficients of variation (CV) among wells within-plates ranged from 4.6 to 20.7% and in two-thirds of the plates exceeded 10%. Duplicates allocated to adjacent wells (method 1) gave consistently higher CV for sample means than duplicates allocated to opposite plate quadrants (method 2). In general, the CV by method 2 was about 30% smaller than that by method 1. Analysis of variance confirmed the effectiveness of the quadrant pattern of duplicate allocation as a method of controlling variation that arises from well position effects. 相似文献