首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 62 毫秒
1.
目的 为了解天然放射性核素226Ra、228Ra、210Pb与210Po在水生物及食物链中转移和蓄积情况。方法 定点采集养殖水产品及栖息环境中水与底质沉积物, 按不同的实验需要, 每个鲜样分别剥取肉, 骨(壳),鳞片和胃肠。烹饪样品, 洗净、称重、清炖, 熟后分离出骨(壳),余为食物。样品分别测定226Ra、228Ra、210Pb和210Po含量。数据按统计学要求处理, 配对数据, 作了配对显着性检验。结果 226Ra、228Ra和210Pb主要沉积于骨(壳)中, 浓集系数为102~103,肉中为100~102.210Po主要蓄积在水生物胃肠中, 浓集系数在102~104,鱼类胃肠与贝类肉中可达104.水产食品烹饪加工过程226Ra、228Ra和210Pb在食物链中转移不明显, 经配对显着性检验, 差异无显着性(P0.05);然而210Po在淡水鱼类和虾类中转移是明显的, 肉配对检验有非常显着性差别(P<0.01).结论水生物对226Ra、228Ra、210Pb和210Po有很强浓集能力。  相似文献   

2.
The binding of 67Ga and 59Fe by placenta and tumors was compared. After sonification, about 50% of the total radioactivity was present in the insoluble fraction consisting of heavy subcellular particles (mitochondria, fragments of membranes, nuclei, etc.) and known to be rich in lipo- and glycoproteins. Heat denaturation and gel filtration were used to study transferrin and ferritin distribution in the supernatant. The differences between 59Fe and 67Ga uptake in this supernatant seemed to indicate that the transferrin-ferritin system plays a less important role in 67Ga binding than in 59Fe binding.  相似文献   

3.

Purpose

To evaluate the diagnostic performance of 68Ga-DOTATATE 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT), 18F-FDG PET/CT and 131I-MIBG scintigraphy in the mapping of metastatic pheochromocytoma and paraganglioma.

Materials and Methods

Seventeen patients (male = 8, female = 9; age range, 13–68 years) with clinically proven or suspicious metastatic pheochromocytoma or paraganglioma were included in this prospective study. Twelve patients underwent all three modalities, whereas five patients underwent 68Ga-DOTATATE and 131I-MIBG without 18F-FDG. A composite reference standard derived from anatomical and functional imaging findings, along with histopathological information, was used to validate the findings. Results were analysed on a per-patient and on per-lesion basis. Sensitivity and accuracy were assessed using McNemar’s test.

Results

On a per-patient basis, 14/17 patients were detected in 68Ga-DOTATATE, 7/17 patients in 131I-MIBG, and 10/12 patients in 18F-FDG. The sensitivity and accuracy of 68Ga-DOTATATE, 131I-MIBG and 18F-FDG were (93.3 %, 94.1 %), (46.7 %, 52.9 %) and (90.9 %, 91.7 %) respectively. On a per-lesion basis, an overall of 472 positive lesions were detected; of which 432/472 were identified by 68Ga-DOTATATE, 74/472 by 131I-MIBG, and 154/300 (patient, n = 12) by 18F-FDG. The sensitivity and accuracy of 68Ga-DOTATATE, 131I-MIBG and 18F-FDG were (91.5 %, 92.6 % p < 0.0001), (15.7 %, 26.0 % p < 0.0001) and (51.3 %, 57.8 % p < 0.0001) respectively. Discordant lesions were demonstrated on 68Ga-DOTATATE, 131I-MIBG and 18F-FDG.

Conclusions

Ga-DOTATATE PET/CT shows high diagnostic accuracy than 131I-MIBG scintigraphy and 18F-FDG PET/ CT in mapping metastatic pheochromocytoma and paraganglioma.  相似文献   

4.
Purpose For the internal radiotherapy of neuroendocrine tumours, the somatostatin analogue DOTATOC labelled with 90Y is frequently used [90Y-DOTA-Phe1-Tyr3-octreotide (SMT487-OctreoTher)]. Radiation exposure to the kidneys is critical in this therapy as it may result in renal failure. The aim of this study was to compare cumulative organ and tumour doses based upon dosimetric data acquired with the chemically identical 86Y-DOTA-Phe1-Tyr3-octreotide (considered as the gold standard) and the commercially available 111In-pentetreotide.Methods The cumulative organ and tumour doses for the therapeutic administration of 13.32 GBq 90Y-DOTA-Phe1-Tyr3-octreotide (three cycles, each of 4.44 GBq) were estimated based on the MIRD concept (MIRDOSE 3.1 and IMEDOSE). Patients with a cumulative kidney dose exceeding 27 Gy had to be excluded from subsequent therapy with 90Y-DOTA-Phe1-Tyr3-octreotide, in accordance with the directives of the German radiation protection authorities.Results The range of doses (mGy/MBq 90Y-DOTA-Phe1-Tyr3-octreotide) for kidneys, spleen, liver and tumour masses was 0.6–2.8, 1.5–4.2, 0.3–1.3 and 2.1–29.5 (86Y-DOTA-Phe1-Tyr3-octreotide), respectively, versus 1.3–3.0, 1.8–4.4, 0.2–0.8 and 1.4–19.7 (111In-pentetreotide), with wide inter-subject variability. Despite renal protection with amino acid infusions, estimated cumulative kidney doses in two patients exceeded 27 Gy.Conclusion Compared with 86Y-DOTA-Phe1-Tyr3-octreotide, dosimetry with 111In-pentetreotide overestimated doses to kidneys and spleen, whereas the radiation dose to the tumour-free liver was underestimated. However, both dosimetric approaches detected the two patients with an exceptionally high radiation burden to the kidneys that carried a potential risk of renal failure following radionuclide therapy.  相似文献   

5.
90Y is one of the most useful radionuclides for radioimmunotherapeutic applications and has a half-life (t1/2=64.14 h) suitable for most therapeutic applications, beta particles of high energy and decays to a stable daughter. It is significant that 90Y is available conveniently and inexpensively from a radionuclide “generator” by decay of its parent, 90Sr. Nevertheless, current and planned clinical applications with [90Y] labelled compounds employ activity levels that cannot be readily obtained from an in-house generator, but from commercial sources. We have evaluated Eichrom's Sr-resin, either as an “in-house” generator or as a fast QC method for analysis of 90Y solutions.In particular, for the development as a generator, we investigated the percentage of the radio-Sr in the first 8 M HNO3 eluate: in this fraction the concentration of 90Sr must be smaller than 10−5% (recommendations of the International Commission on Radiological Protection). For evaluation as a rapid QC method, we analyzed the concentration of 90Y in all the fractions containing “only” radio-Sr: 90Y should not be present in these eluates. After the collection of β and γ spectra and analysis of them, we concluded that commercial Sr-resin minicolumn cannot give us the results expected; we developed an in-house system loaded with 4 mL of Sr-resin which gave better results as a generator and a rapid QC method.  相似文献   

6.
A newly designed inorganic ion exchanger, based on aluminum vanadate, has been synthesized and characterized by elemental analysis, spectroscopic tools and powdered X-ray diffraction. The insoluble poorly polycrystalline material is highly stable towards thermal and radiation doses and in various chemical environments. The data of exchange capacities of the solid material for the different alkali and alkaline metal ions determined by batch technique show that the compound can be employed as an ion exchanger. The successful radiochemical separations of the no carrier added daughter nuclides; 137mBa and 115mIn from their respective parents present in equilibrium mixtures have been carried out using this material. Elutions of 137mBa and 115mIn were performed using 0.0426 mol L−1 ascorbic acid solution and 4.0 mol L−1 HCl, respectively, after sorption of the equilibrated mixtures 137Cs–137mBa at 0.01 mol L−1 HCl medium and 115Cd–115mIn at pH 7.0, respectively. In another column operation, it has been observed that the separation of gold and silver is possible with the help of the eluents, 0.01% alcoholic solution of Rhodamine-B for gold and 0.5% thiourea solution in 0.1 mol L−1 HClO4 for silver, respectively, after the sorption of no carrier added onto this material at pH 2.0, at a no carrier added level.  相似文献   

7.
Summary Four patients with cerebral hemorrhage were examined serially from the acute to chronic phase by1H magnetic resonance imaging (MRI),23Na MRI and computed tomography (CT). At 1–2 days after bleeding, the23Na image revealed no visible signal change in the area of hemorrhage, although CT and1H images clearly demonstrated the existence of a hematoma in the thalamus or putamen. At 4–7 days after the hemorrhage, the23Na images began to exhibit a small increase in signal intensity at the hematoma site, while at 2–3 weeks, a marked increase in23Na signal intensity was observed. These findings suggest that the hematoma consisted mainly of a corpuscular component, with a low Na+ concentration, with little serum component. Lack of signal from the corpuscular component on the23Na image was confirmed by an in vitro study. In the late acute phase, Na+ accumulation may occur in the corpuscular component due to failure of the Na+ pump. The intracellular23Na appears to be totally visible to MRI, resulting in an increase in signal intensity. In the subacute or chronic phase, the corpuscular component may be destroyed, leaving fluid in its place. A high Na+ concentration in this fluid may give markedly increased23Na signal intensity on MRI.23Na MRI appears to provide important information for understanding the evoluation of cerebral hemorrhage and for estimating the viability of cells, although its value for diagnosis may not be great.  相似文献   

8.
Aim  To compare the diagnostic impact of 68Ga-DOTA-TATE and 18F-DOPA PET in the diagnosis of well-differentiated metastatic neuroendocrine tumours (NET). Methods  PET/CT using both 68Ga-DOTA-TATE and 18F-DOPA was performed in 25 patients with histologically proven metastatic NET (nine gut, five pancreas, six lung, one paranasal sinus, four with unknown primary). Analyses of PET examinations were patient-based (pathological uptake: yes/no), and based on tumour regions (primary tumour if present and metastases of liver, lung, bones and lymph nodes). The results were compared with the results of contrast enhanced CT, and with plasma serotonin levels, which were available in 24 of the 25 patients. Results  Patient-based sensitivities were 96% for 68Ga-DOTA-TATE PET and 56% for 18F-DOPA PET. 68Ga-DOTA-TATE PET delineated metastases in 54 of 55 positive metastatic tumour regions in contrast to 29 of 55 delineated by 18F-DOPA PET. Overall, 68Ga-DOTA-TATE was superior to 18F-DOPA in 13 patients (two patients showed fewer positive tumour regions with 18F-DOPA PET). The results were comparable in 12 patients. In 13 of 24 patients, plasma serotonin levels were elevated, and 11 of these 13 patients showed pathological uptake of 18F-DOPA. Of the 11 patients with normal levels of serotonin, 3 also showed positive 18F-DOPA uptake. In patients positive for 18F-DOPA uptake the maximum tumour SUVs were correlated with the levels of serotonin (r=0.66, p=0.01). Conclusion  In this study 68Ga-DOTA-TATE PET proved clearly superior to 18F-DOPA PET for detection and staging of NET. 18F-DOPA uptake tended to be increased in those patients with elevated plasma serotonin. We conclude that 18F-DOPA PET should be employed in patients with NET with negative 68Ga-DOTA-TATE PET and elevated plasma serotonin.  相似文献   

9.
In an attempt to visualize folate receptors that overexpress on many cancers, [18F]-fluorobenzene and pyridinecarbohydrazide-folate/methotrexate conjugates ([18F]-1, [18F]-2-folates and [18F]-8, [18F]-9-MTXs) were synthesized by the nucleophilic displacement reactions using ethyl-trimethylammonium-benzoate and pyridinecarboxylate precursors. The intermediates ethyl [18F]-fluorinated benzene and pyridine esters were reacted with hydrazine to produce the [18F]-fluorobenzene and pyridinecarbohydrazides, followed by coupling with N-hydroxysuccinimide-folate/MTX. Radiochemical yields were greater than 80% (decay corrected), with total synthesis time of less than 45 min. Radiochemical purities were always greater than 97% without high-performance liquid chromatography purification. These synthetic approaches hold considerable promise as rapid and simple method for the radiofluorination of folate derivatives with high radiochemical yield in short synthesis time. In vitro tests on KB cell line showed that significant amount of the radioconjugates were associated with cell fractions, and in vivo characterization in normal Balb/c mice revealed rapid blood clearance of these radioconjugates with excretion predominantly by the urinary and partially by the hepatobiliary systems. Biodistribution studies in nude mice bearing human KB cell line xenografts demonstrated significant tumor uptake and favorable biodistribution profile for [18F]-2-folate over the other conjugates. The uptake in the tumors was blocked by excess coinjection of folic acid, suggesting a receptor-mediated process. Micro-positron emission tomography images of nude mice bearing human KB cell line xenografts confirmed these observations. These results demonstrate that [18F]-2-folate may be useful as molecular probe for detecting and staging of folate receptor-positive cancers, such as ovarian cancer and their metastasis as well as monitoring tumor response to treatment.  相似文献   

10.
目的 提高222Rn与220Rn的累积测量水平,保证测量结果的准确性与可靠性。方法 采用中国疾病预防控制中心辐射防护与核安全医学所的氡课题组(以下简称本实验室)改进的LD-P型222Rn-220Rn分辨探测器参加日本放射线医学综合研究所(NIRS)组织的222Rn-220Rn累积探测器国际比对。将222Rn-220Rn分辨探测器寄往日本,在NIRS的222Rn室和220Rn室进行不同条件下的比对,暴露结束后再寄回本实验室进行蚀刻与分析,测量结果告知NIRS。最后NIRS将222Rn与220Rn暴露参考值回馈本实验室。结果 在高222Rn和低222Rn条件下,测量值与NIRS提供的参考值的相对百分偏差(RPD)分别为-12.0%、-11.8%;变异系数(COV)分别为3.0%、6.2%。在高220Rn和低220Rn条件下,测量值与NIRS提供的参考值的相对百分偏差(RPD)分别为-0.8%、-8.0%;变异系数(COV)分别为6.7%、4.5%。结论 本次比对LD-P型探测器222Rn与220Rn的测量结果均为NIRS规定的Ι级结果(PRD<10%),比对结果较好。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号