相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
本文介绍了在临床实际中利用功能性参数,对冠状动脉DSA心肌血流灌注成像、冠状动脉血流量测定、左心室功能测定、肺动脉高压程度的评价等项目研究结果。重点讨论了提取DSA功能性参数的一般方法,认为功能性参数在现代影像诊断学中的作用是对疾病做出程度、定量、动态及功能诊断。  相似文献   

2.
A technique is described that provides improved reproducibility of breath-holding for MR image acquisition by monitoring the superior-inferior (S/I) position of the diaphragm. The method incorporates detection of the level of inspiration using an MR signal, rapid display to the patient of diaphragm position to enable breath-hold adjustment, and triggering of image data acquisition once appropriate position is attained. The response time of the system is short, approximately 10 ms. Studies in six volunteers using this method demonstrate a considerable decrease in the S/I range of diaphragm position over 10 consecutive periods of suspended respiration. The mean range is 1.3 mm with the system, while it is 8.3 mm without using it is expected that this method will be of assistance in many abdominal and cardiothoracic studies that use breath-hold techniques.  相似文献   

3.
PURPOSE: To investigate the use of a three-dimensional rapid acquisition with relaxation enhancement (RARE) pulse sequence for direct acquisition of phosphocreatine (PCr) images of the human myocardium. MATERIALS AND METHODS: A short elliptical birdcage radiofrequency (RF) body coil was constructed to produce a uniform flip angle throughout the chest cavity. In vivo images using a spectrally-selective RARE sequence with a spatial resolution of 1.2 cm x 1.2 cm x 2.5 cm (4 cm(3)) were acquired in nine minutes and 40 seconds. RESULTS: Scans of phantoms demonstrated excellent spectral selectivity. The signal-to-noise ratio in the myocardium ranged from 12.6 in the anterior wall to 5.3 in the mid septum. CONCLUSION: This study demonstrates that PCr data can be acquired using a three-dimensional RARE sequence with greater spatial and temporal resolution than spectroscopic techniques.  相似文献   

4.
5.
Optical imaging techniques use visual and near infrared rays. Despite their considerably poor penetration depth, they are widely used due to their safe and intuitive properties and potential for intraoperative usage. Optical imaging techniques have been actively investigated for clinical imaging of lymph nodes and lymphatic system. This article summarizes a variety of optical tracers and techniques used for lymph node and lymphatic imaging, and reviews their clinical applications. Emerging new optical imaging techniques and their potential are also described.  相似文献   

6.
Simultaneous multislice imaging (SMS) using parallel image reconstruction has rapidly advanced to become a major imaging technique. The primary benefit is an acceleration in data acquisition that is equal to the number of simultaneously excited slices. Unlike in‐plane parallel imaging this can have only a marginal intrinsic signal‐to‐noise ratio penalty, and the full acceleration is attainable at fixed echo time, as is required for many echo planar imaging applications. Furthermore, for some implementations SMS techniques can reduce radiofrequency (RF) power deposition. In this review the current state of the art of SMS imaging is presented. In the Introduction, a historical overview is given of the history of SMS excitation in MRI. The following section on RF pulses gives both the theoretical background and practical application. The section on encoding and reconstruction shows how the collapsed multislice images can be disentangled by means of the transmitter pulse phase, gradient pulses, and most importantly using multichannel receiver coils. The relationship between classic parallel imaging techniques and SMS reconstruction methods is explored. The subsequent section describes the practical implementation, including the acquisition of reference data, and slice cross‐talk. Published applications of SMS imaging are then reviewed, and the article concludes with an outlook and perspective of SMS imaging. Magn Reson Med 75:63–81, 2016. © 2015 The Authors. Magnetic Resonance in Medicine Published by Wiley Periodicals, Inc. on behalf of International Society of Medicine in Resonance.  相似文献   

7.
Spiral imaging has a number of advantages for fast imaging, including an efficient use of gradient hardware. However, inhomogeneity-induced blurring is proportional to the data acquisition duration. In this paper, we combine spiral data acquisition with a RARE echo train. This allows a long data acquisition interval per excitation, while limiting the effects of inhomogeneity. Long spiral k-space trajectories are partitioned into smaller, annular ring trajectories. Each of these annular rings is acquired during echoes of a RARE echo train. The RARE refocusing RF pulses periodically refocus off-resonant spins while building a long data acquisition. We describe both T2-weighted single excitation and interleaved RARE spiral sequences. A typical sequence acquires a complete data set in three excitations (32 cm FOV, 192 × 192 matrix). At a TR = 2000 ms, we can average two acquisitions in an easy breath-hold interval. A multifrequency reconstruction algorithm minimizes the effects of any off-resonant spins. Though this algorithm needs a field map, we demonstrate how signal averaging can provide the necessary phase data while increasing SNR. The field map creation causes no scan time penalty and essentially no loss in SNR efficiency. Multiple slice, 14-s breath-hold scans acquired on a conventional gradient system demonstrate the performance.  相似文献   

8.
A new technique for rapid spectroscopic imaging is presented. The proposed experiment enables a complete mapping of the two-dimensional reciprocal space kx, ko, and thus the acquisition of a 1D spectroscopic image in a single scan. The properties of the pulse sequence, based on the use of a burst of low flip angle pulses, are analyzed in the framework of linear response theory, and it is shown that chemical shift information may be introduced into the spatially encoded echoes. First experimental results are presented demonstrating that 32 x 32 proton spectroscopic images may be acquired within less than 1 min with a conventional imaging system.  相似文献   

9.
RATIONALE AND OBJECTIVES: We sought to identify and describe the characteristics of molecular imaging (MI) programs in the United States and to determine the factors considered critical for their future. MATERIALS AND METHODS: In a cross-sectional study, a validated survey was sent to members of the Society of Chairmen in Academic Radiology Departments (SCARD) in the United States, and 26 variables were studied. RESULTS: The response rate was 40.3%; 67.9% of the departments surveyed have an MI program. The main focus of 47.4% of departments is oncology. The number of radiologists working for the department was the only variable found to be significantly positively correlated with (1) number of researchers in the MI program, (2) number of MI modalities available, (3) total number of grants, and (4) having ongoing MI clinical trials. These four variables plus the number of federal grants and the space used by MI programs were independent of the geographical region, hospital size (number of beds), and department size (number of radiological examinations per year). All the MI programs received grants during 2005. Only 16.1% have no alliances with industry. Among all the departments, 82% identified staff training and recruitment as the keys for success; 78.57% considered oncology the most important future application of MI and cancer management the hospital service most affected by MI. CONCLUSION: MI programs are starting to be more widespread throughout the United States, and the trend is for more academic radiology departments to become engaged in MI activities; their development is independent of department characteristics. Radiology departments strongly agreed about the key components for success of MI initiatives and the areas that will be most affected by MI applications.  相似文献   

10.
Magnetic resonance temperature imaging can be used to monitor the progress of thermal ablation therapies, increasing treatment efficacy and improving patient safety. High temporal resolution is important when therapies rapidly heat tissue, but many approaches to faster image acquisition compromise image resolution, slice coverage, or phase sensitivity. Partially parallel imaging techniques offer the potential for improved temporal resolution without forcing such concessions. Although these techniques perturb image phase, relative phase changes between dynamically acquired phase-sensitive images, such as those acquired for MR temperature imaging, can be reliably measured through partially parallel imaging techniques using reconstruction filters that remain constant across the series. Partially parallel and non-accelerated phase-difference-sensitive data can be obtained through arrays of surface coils using this method. Average phase differences measured through partially parallel and fully Fourier encoded images are virtually identical, while phase noise increases with g(sqrt)L as in standard partially parallel image acquisitions..  相似文献   

11.
Introduction In vivo bioluminescence imaging (BLI) is a promising technique for non-invasive tumour imaging. d-luciferin can be administrated intraperitonealy or intravenously. This will influence its availability and, therefore, the bioluminescent signal. The aim of this study is to compare the repeatability of BLI measurement after IV versus IP administration of d-luciferin and assess the correlation between photon emission and histological cell count both in vitro and in vivo. Materials and methods Fluc-positive R1M cells were subcutaneously inoculated in nu/nu mice. Dynamic BLI was performed after IV or IP administration of d-luciferin. Maximal photon emission (PEmax) was calculated. For repeatability assessment, every acquisition was repeated after 4 h and analysed using Bland–Altman method. A second group of animals was serially imaged, alternating IV and IP administration up to 21 days. When mice were killed, PEmax after IV administration was correlated with histological cell number. Results The coefficients of repeatability were 80.2% (IV) versus 95.0% (IP). Time-to-peak is shorter, and its variance lower for IV (p < 0.0001). PEmax was 5.6 times higher for IV. A trend was observed towards lower photon emission per cell in larger tumours. Conclusion IV administration offers better repeatability and better sensitivity when compared to IP. In larger tumours, multiple factors may contribute to underestimation of tumour burden. It might, therefore, be beneficial to test novel therapeutics on small tumours to enable an accurate evaluation of tumour burden. Marleen Keyaerts is a Ph. D. fellow of the Research Foundation—Flanders (Belgium; FWO).  相似文献   

12.
In some dynamic imaging applications, only a fraction, 1/n, of the field of view (FOV) may show considerable change during the motion cycle. A method is presented that improves the temporal resolution for a dynamic region by a factor, n, while maintaining spatial resolution at a cost of √n in signal-to-noise ratio (SNR). Temporal resolution is improved, or alternatively, total imaging time is reduced by reducing the number of phase encodes acquired for each temporal frame by 1/n. To eliminate aliasing, a representation of the signal from the static outer portion of the FOV is constructed using all the raw data. The k-space data derived from this representation is subtracted from the original data sets, and the differences correspond to the dynamic portion of the FOV. Improved resolution results are presented in phantom studies, and in vivo phase contrast quantitative flow imaging.  相似文献   

13.
Although RARE and GRASE can produce single-shot images of excellent quality, their utility has been restricted because preparation of the magnetization with interesting contrast before imaging can cause severe artifacts. These artifacts relate to the strong sensitivity of multiple spin echo sequences to the phase of the prepared magnetization. Modifications of the RARE sequence to eliminate these artifacts are discussed, and an approach that eliminates the artifact producing signals from the very first echo is presented. The approach is applied to diffusion imaging of the human brain in normal volunteers and one patient.  相似文献   

14.
High-resolution computed tomography (CT) and magnetic resonance imaging (MRI) have become indispensable tools for the evaluation of conditions involving the head and neck. Complex anatomic structures and regions, such as the orbit, skull base, paranasal sinuses, deep spaces of the neck, larynx, and lymph nodes, require that the radiologist be familiar with the imaging modalities available and their appropriate applications. The purpose of this article is to review the techniques of CT and MRI and the roles they play in clinical practice, including head and neck disorders.  相似文献   

15.
磁敏感加权成像是利用不同组织间磁化率不同而产生图像对比的一项新技术.SWI在显示细小出血灶、肿瘤相关静脉结构、钙化等方面优于常规MR序列,是研究肿瘤内部结构的一种新的方法.其在脑肿瘤中的应用近年来进展迅速,本文就其最新进展加以综述.  相似文献   

16.

Purpose

CAIPIRINHA-Dixon-TWIST (CDT)-VIBE is a robust method for abdominal magnetic resonance imaging providing both high spatial and high temporal resolution. The purpose of this study was to examine the influence of different gadolinium based contrast agents (GBCA) on image quality (IQ) with CDT-VIBE.

Materials and methods

In this IRB-approved, retrospective, inter-individual comparison study, 86 patients scanned at 3T were included. Within 28 s, 14 high-resolution 3D datasets were acquired using CDT-VIBE. 37 patients received 0.1 mmol/kg gadoterate meglumine, 28 patients 0.1 mmol/kg gadobutrol, and 19 patients 0.1 mL/kg gadoxetic acid. Two blinded, board-certified radiologists assessed the image quality on a 5 point scale, as well as the number of hepatic arterial dominant (HAD) phases.

Results

Regardless of the GBCA utilized, CDT-VIBE resulted in good IQ in terms of best IQ achieved among all 14 datasets (gadobutrol 4.3, gadoterate meglumine 3.9, gadoxetic acid 3.7). With respect to worst IQ, the three groups showed statistically significant differences with gadobutrol receiving the highest rating (3.6) and gadoxetic acid the lowest (2.4) (gadoterate meglumine 3.0; 0.0014 < p < 0.0485). No statistically significant differences were found in the mean number of acquired HAD phases (gadobutrol 3.4, gadoterate meglumine 3.9, gadoxetic acid 3.1; 0.18 < p < 0.57).

Conclusion

Different gadolinium-based contrast agents can be utilized for dynamic liver imaging with CDT-VIBE resulting in good image quality.  相似文献   

17.
We describe a technique to increase the velocity-to-noise ratio (VNR) of phase-contrast magnetic-resonance velocity images based on making three measurements/flow encoding axis rather than the usual two. A phase-aliased high first moment data set and a nonaliased low first moment data set are acquired, and the high-moment data are phase unwrapped using the low-moment data. The VNR of the resulting measurement is given by that of the high-moment measurement and increases linearly with the first moment. A factor of 4 gain in VNR was observed with only a 50% increase in scan time. Thus, this method is a much more efficient way to increase VNR than simple averaging.  相似文献   

18.
19.
In dynamic MRI, it is often difficult to achieve the acquisition speed required to resolve or freeze the temporal variations of the imaged object. Several MRI methods aim at speeding up the image acquisition process. Through assumptions and/or prior knowledge, these dynamic MRI methods allow part of the needed data to be calculated instead of acquired. For example, partial-Fourier imaging assumes that phase varies smoothly within the object, and parallel imaging (e.g., simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE)) uses prior knowledge about receiver-coil sensitivity. While these methods accelerate acquisition, they can introduce artifacts or amplify noise in doing so. The present work aims at accelerating image acquisition significantly, while introducing almost no artifacts or noise amplification. It is shown here that new, extra information is gained if dynamic MRI methods are modified so that the sampling function changes in specific ways from time-frame to time-frame. In other words, the set of k-space locations that are acquired (instead of calculated) changes with time. The present temporal strategy, based on the UNaliasing by Fourier-encoding the Overlaps in the temporaL Dimension (UNFOLD) method, can be incorporated into common dynamic MRI methods. Results with partial-Fourier, SMASH, and SENSE imaging are presented here, where UNFOLD's contribution is to very significantly reduce the artifact and/or amplified noise content. Used in this way, UNFOLD contributes indirectly, rather than directly to the improvement in image acquisition speed, as it allows companion methods to operate properly at greater acceleration settings than would otherwise be feasible.  相似文献   

20.
A velocity k-space formalism facilitates the analysis of flow effects for imaging sequences involving time-varying gradients such as echo-planar and spiral. For each sequence, the velocity k-space trajectory can be represented by kv (k)r; that is, its velocity-frequency (kr) position as a function of spatial-frequency (kr) position. In an echo-planar sequence, kr is discontinuous and asymmetric. However, in a spiral sequence, kr is smoothly varying, circularly symmetric, and small near the kr origin. To compare the effects of these trajectory differences, simulated images were generated by computing the k-space values for an in-plane vessel with parabolic flow. Whereas the resulting echo-planar images demonstrate distortions and ghosting that depend on the vessel orientation, the spiral images exhibit minimal artifacts.  相似文献   