 共查询到20条相似文献,搜索用时 62 毫秒
1.
PURPOSE: To examine the spoiled steady-state (spoiled gradient-recalled echo sequence [SPGR]) signal arising from two-compartment systems and the role of experimental parameters, in particular TR for resolving signal from each compartment. MATERIALS AND METHODS: Using Bloch-McConnell simulations, we examined the SPGR signal from two-component systems in which T(1) is much greater than the mean residence time (tau(m)) of proton spins in each component. Specifically, we examined the role of TR on the ability to resolve each components signal, as well as the influence of experimental parameters on derived DESPOT1 T(1) values. RESULTS: Results revealed that when TR < or = 0.01 tau(m), the measured SPGR signal may be modeled as a summation of signal from each species using a no-exchange approximation. Additionally, under this short TR condition, the driven equilibrium single pulse observation of T(1) (DESPOT1) mapping approach provides T(1) values preferentially biased toward the short or long T(1) species, depending on the choice of flip angles. CONCLUSION: The ability to model the SPGR signal using a no-exchange approximation may permit the quantification multicomponent T(1) relaxation in vivo. Additionally, the ability to preferentially weight the DESPOT1 T(1) value toward the short or long T(1) may provide a useful window into these components.  相似文献   

2.
Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) is based on the theory that Gd-DTPA(2-) will distribute in inverse relation to cartilage glycosaminoglycan (GAG). T(1Gd) (T(1) after penetration of a 0.2 mmol/kg dose of Gd-DTPA(2-)) has been used as the dGEMRIC index, although (1/T(1Gd)-1/T(1o)) should be more representative of Gd-DTPA(2-) concentration (where T(1o) = T(1) before contrast). T(1o) and T(1Gd) were measured in 20 volunteers at both 1.5T and 3T and the correlation between the metrics of T(1Gd) and (1/T(1Gd)-1/T(1o)) was calculated. There was a high correlation coefficient between the two metrics at both field strengths, with R = 0.94, 0.93, and 0.90 for central medial femur, posterior medial femur, and medial tibia, respectively, at 1.5T and 0.87, 0.94, 0.96 at 3T. In all cases P < 0.0001. Therefore, these data suggest that, for native cartilage, the current practice of measuring T(1Gd) (but not also T(1o)) is adequate at both 1.5T and 3T.  相似文献   

3.
This work describes observed changes in the proton T1 relaxation time of both water and lipid when they are in relatively homogeneous mixtures. Results obtained from vegetable oil–water emulsions, pork kidney and lard mixtures, and excised samples of white and brown adipose tissues are presented to demonstrate this change in T1 as a function of mixture fat fraction. As an initial proof of concept, a simpler acetone‐water experiment was performed to take advantage of complete miscibility between acetone and water and both components' single chemical shift peaks. Single‐voxel MR spectroscopy was used to measure the T1 of predominant methylene spins in fat and the T1 of water spins in each setup. In the vegetable oil–water emulsions, the T1 of fat varied by as much as 3‐fold when water was the dominant mixture component. The T1 of pure lard increased by 170 msec (+37%) when it was blended with lean kidney tissue in a 16% fatty mixture. The fat T1 of lipid‐rich white adipose tissue was 312 msec. In contrast, the fat T1 of leaner brown adipose tissue (fat fraction 53%) was 460 msec. A change in the water T1 from that of pure water was also observed in the experiments. Magn Reson Med, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

4.
PURPOSE: To develop a T1rho-prepared, balanced gradient echo (b-GRE) pulse sequence for rapid three-dimensional (3D) T1rho relaxation mapping within the time constraints of a clinical exam (<10 minutes), examine the effect of acquisition on the measured T1rho relaxation time and optimize 3D T1rho pulse sequences for the knee joint and spine. MATERIALS AND METHODS: A pulse sequence consisting of inversion recovery-prepared, fat saturation, T1rho-preparation, and b-GRE image acquisition was used to obtain 3D volume coverage of the patellofemoral and tibiofemoral cartilage and lower lumbar spine. Multiple T1rho-weighted images at various contrast times (spin-lock pulse duration [TSL]) were used to construct a T1rho relaxation map in both phantoms and in the knee joint and spine in vivo. The transient signal decay during b-GRE image acquisition was corrected using a k-space filter. The T1rho-prepared b-GRE sequence was compared to a standard T1rho-prepared spin echo (SE) sequence and pulse sequence parameters were optimized numerically using the Bloch equations. RESULTS: The b-GRE transient signal decay was found to depend on the initial T1rho-preparation and the corresponding T1rho map was altered by variations in the point spread function with TSL. In a two compartment phantom, the steady state response was found to elevate T1rho from 91.4+/-6.5 to 293.8+/-31 and 66.9+/-3.5 to 661+/-207 with no change in the goodness-of-fit parameter R2. Phase encoding along the longest cartilage dimension and a transient signal decay k-space filter retained T1rho contrast. Measurement of T1rho using the T1rho-prepared b-GRE sequence matches standard T1rho-prepared SE in the medial patellar and lateral patellar cartilage compartments. T1rho-preparedb-GRE T1rho was found to have low interscan variability between four separate scans. Mean patellar cartilage T1rho was elevated compared to femoral and tibial cartilage T1rho. CONCLUSION: The T1rho-prepared b-GRE acquisition rapidly and reliably accelerates T1rho quantification of tissues offset partially by a TSL-dependent point spread function.  相似文献   

5.
6.
7.
8.
The possibility that cerebral tumours may be graded by measuring T1 or T2 with magnetic resonance (MR) imaging was studied. A consecutive series of patients with subsequently verified gliomas was enrolled, and studied with MR. Patients who had prior surgical, chemotherapeutic or steroid treatment were excluded. Single slice multiple saturation recovery and multiple spin echo techniques were used to measure T1, T2 and proton density in the tumour. In 33 patients with cerebral gliomas there were 5 grade I, 12 grade II, 7 grade III and 9 grade IV. T1 and T2 values tended to be smaller in grade I gliomas than in grades II, III and IV gliomas. Relaxation parameters overlapped considerably in tumours with different grades. Proton density values did not show much change between different grades of gliomas. Relaxation parameters cannot be used to determine tumour grade reliably. Correspondence to: S. Newman  相似文献   

9.
Delayed gadolinium-enhanced MRI of cartilage is a technique for studying the development of osteoarthritis using quantitative T(1) measurements. Three-dimensional variable flip angle is a promising method for performing such measurements rapidly, by using two successive spoiled gradient echo sequences with different excitation pulse flip angles. However, the three-dimensional variable flip angle method is very sensitive to inhomogeneities in the transmitted B(1) field in vivo. In this study, a method for correcting for such inhomogeneities, using an additional B(1) mapping spin-echo sequence, was evaluated. Phantom studies concluded that three-dimensional variable flip angle with B(1) correction calculates accurate T(1) values also in areas with high B(1) deviation. Retrospective analysis of in vivo hip delayed gadolinium-enhanced MRI of cartilage data from 40 subjects showed the difference between three-dimensional variable flip angle with and without B(1) correction to be generally two to three times higher at 3 T than at 1.5 T. In conclusion, the B(1) variations should always be taken into account, both at 1.5 T and at 3 T.  相似文献   

10.
11.
The longitudinal relaxation time of blood is a crucial parameter for quantification of cerebral blood flow by arterial spin labeling and is one of the main determinants of the signal‐to‐noise ratio of the resulting perfusion maps. Whereas at low and medium magnetic field strengths (B0), its in vivo value is well established; at ultra‐high field, this is still uncertain. In this study, longitudinal relaxation time of blood in the sagittal sinus was measured at 1.5 T, 3 T, and 7 T. A nonselective inversion pulse preceding a Look‐Locker echo planar imaging sequence was performed to obtain the inversion recovery curve of venous blood. The results showed that longitudinal relaxation time of blood at 7 T was ~ 2.1 s which translates to an anticipated 33% gain in the signal‐to‐noise ratio in arterial spin labeling experiments due to T1 relaxation alone compared with 3 T. In addition, the linear relationship between longitudinal relaxation time of blood and B0 was confirmed. Magn Reson Med, 70:1082–1086, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

12.
PURPOSE: To compare T(1) values of blood and myocardium at 1.5T and 3T before and after administration of Gd-DTPA-BMA in normal volunteers, and to evaluate the distribution of contrast media between myocardium and blood during steady state. MATERIALS AND METHODS: Ten normal subjects were imaged with either 0.1 mmol/kg (N = 5) or 0.2 mmol/kg (N = 5) of Gd-DTPA-BMA contrast agent at 1.5T and 3T. T(1) measurements of blood and myocardium were performed prior to contrast injection and every five minutes for 35 minutes following contrast injection at both field strengths. Measurements of biodistribution were calculated from the ratio of DeltaR(1) (DeltaR(1myo)/DeltaR(1blood)). RESULTS: Precontrast blood T(1) values (mean +/- SD, N = 10) did not significantly differ between 1.5T and 3T (1.58 +/- .13 sec, and 1.66 +/- .06 sec, respectively; P > 0.05), but myocardium T(1) values were significantly different (1.07 +/- .03 sec and 1.22 +/- .07 sec, respectively; P < 0.05). The field-dependent difference in myocardium T(1) postinjection (T(1)@3T - T(1)@1.5T) decreased by approximately 72% relative to precontrast T(1) values, while the field-dependent difference of blood T(1) decreased only 30% postcontrast. Measurements of DeltaR(1myo)/DeltaR(1blood) were constant for 35 minutes postcontrast, but changed between 1.5T and 3T (0.46 +/- .06 vs. 0.54 +/- .06, P < 0.10). CONCLUSION: T(1) is significantly longer for myocardium (but not blood) at 3T compared to 1.5T. The differences in T(1) due to field strength are reduced following contrast administration, which may be attributed to changes in DeltaR(1myo)/DeltaR(1blood) with field strength.  相似文献   

13.
T and T2 relaxation time constants have been proposed to probe biochemical changes in osteoarthritic cartilage. This study aimed to evaluate the spatial correlation and distribution of T and T2 values in osteoarthritic cartilage. Ten patients with osteoarthritis (OA) and 10 controls were studied at 3T. The spatial correlation of T and T2 values was investigated using Z‐scores. The spatial variation of T and T2 values in patellar cartilage was studied in different cartilage layers. The distribution of these relaxation time constants was measured using texture analysis parameters based on gray‐level co‐occurrence matrices (GLCM). The mean Z‐scores for T and T2 values were significantly higher in OA patients vs. controls (P < 0.05). Regional correlation coefficients of T and T2 Z‐scores showed a large range in both controls and OA patients (0.2–0.7). OA patients had significantly greater GLCM contrast and entropy of T values than controls (P < 0.05). In summary, T and T2 values are not only increased but are also more heterogeneous in osteoarthritic cartilage. T and T2 values show different spatial distributions and may provide complementary information regarding cartilage degeneration in OA. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

14.
MRI methods currently used for bolus tracking in the myocardium, such as saturation recovery turbo-fast low-angle shot (FLASH) (srTFL), are limited by signal intensity (SI) saturation at high contrast agent (CA) concentrations. By using T1 fast acquisition relaxation mapping (T1 FARM), a Gd-DTPA bolus (0.075 vs. 0.025 mmol/kg) may be injected without causing saturation. This study tested the feasibility of in vivo T1 FARM bolus tracking under rest/stress conditions in seven beagles with multiple permanently occluded branches of the left anterior descending (LAD) coronary artery. Although it underestimated the myocardial perfusion reserve (MPR) measured ex vivo using radioactive microspheres (mean +/- SEM; 3.60 +/- 0.26), the MPR determined upon application of the modified Kety model (1.86 +/- 0.10) enabled distinction between normal and infarcted tissue. The partition coefficient (lambda) estimated at rest and stress using the modified Kety model underestimated ex vivo radioactive measurements in infarcted tissue (0.25 +/- 0.01 vs. 0.26 +/- 0.01 vs. 0.79 +/- 0.08 ml/g, P < 0.0001) yet was accurate in normal tissue (0.28 +/- 0.01 vs. 0.30 +/- 0.01 vs. 0.33 +/- 0.01 ml/g, P = NS). Thus, although unsuitable for myocardial viability assessment, T1 FARM bolus tracking shows potential for assessment of myocardial perfusion.  相似文献   

15.
16.
Fast high-resolution T1 mapping of the human brain.   总被引:1,自引:0,他引:1  
A sequence for the acquisition of high-resolution T1 maps, based on magnetization-prepared multislice fast low-angle shot (FLASH) imaging, is presented. In contrast to similar methods, no saturation pulses are used, resulting in an increased dynamic range of the relaxation process. Furthermore, it is possible to acquire data during all relaxation delays because only slice-selective radiofrequency (RF) pulses are used for inversion and excitation. This allows for a reduction of the total acquisition time, or scanning with a reduced bandwidth, which improves the signal-to-noise ratio (SNR). The method generates quantitative T1 maps with an in-plane resolution of 1 mm, slice thickness of 4 mm, and whole-brain coverage in a clinically acceptable imaging time of about 19 s per slice. It is shown that the use of off-center RF pulses does not result in imperfect inversion or magnetization transfer (MT) effects. In addition, an improved fitting algorithm based on smoothed flip angle maps is presented and tested successfully.  相似文献   

17.
T2 and T1rho MRI in articular cartilage systems.   总被引:3,自引:0,他引:3  
T2 and T1rho have potential to nondestructively detect cartilage degeneration. However, reports in the literature regarding their diagnostic interpretation are conflicting. In this study, T2 and T1rho were measured at 8.5 T in several systems: 1) Molecular suspensions of collagen and GAG (pure concentration effects): T2 and T1rho demonstrated an exponential decrease with increasing [collagen] and [GAG], with [collagen] dominating. T2 varied from 90 to 35 ms and T1rho from 125 to 55 ms in the range of 15-20% [collagen], indicating that hydration may be a more important contributor to these parameters than previously appreciated. 2) Macromolecules in an unoriented matrix (young bovine cartilage): In collagen matrices (trypsinized cartilage) T2 and T1rho values were consistent with the expected [collagen], suggesting that the matrix per se does not dominate relaxation effects. Collagen/GAG matrices (native cartilage) had 13% lower T2 and 17% lower T1rho than collagen matrices, consistent with their higher macromolecular concentration. Complex matrix degradation (interleukin-1 treatment) showed lower T2 and unchanged T1rho relative to native tissue, consistent with competing effects of concentration and molecular-level changes. In addition, the heterogeneous GAG profile in these samples was not reflected in T2 or T1rho. 3) Macromolecules in an oriented matrix (mature human tissue): An oriented collagen matrix (GAG-depleted human cartilage) showed T2 and T(1rho) variation with depth consistent with 16-21% [collagen] and/or fibril orientation (magic angle effects) seen on polarized light microscopy, suggesting that both hydration and structure comprise important factors. In other human cartilage regions, T2 and T1rho abnormalities were observed unrelated to GAG or collagen orientation differences, demonstrating that hydration and/or molecular-level changes are important. Overall, these studies illustrate that T2 and T1rho are sensitive to biologically meaningful changes in cartilage. However, contrary to some previous reports, they are not specific to any one inherent tissue parameter.  相似文献   

18.
In this study, we report the use of a novel ultrashort echo time T1rhoT1 sequence that combines a spin‐lock preparation pulse with a two‐dimensional ultrashort echo time sequence of a nominal echo time 8 μsec. The ultrashort echo time‐T1rho sequence was employed to quantify T1rho in short T2 tissues including the Achilles tendon and the meniscus. T1rho dispersion was investigated by varying the spin‐lock field strength. Preliminary results on six cadaveric ankle specimens and five healthy volunteers show that the ultrashort echo time‐T1rho sequence provides high signal and contrast for both the Achilles tendon and the meniscus. The mean T1rho of the Achilles tendon ranged from 3.06 ± 0.51 msec for healthy volunteers to 5.22 ± 0.58 msec for cadaveric specimens. T1rho increased to 8.99 ± 0.24 msec in one specimen with tendon degeneration. A mean T1rho of 7.98 ± 1.43 msec was observed in the meniscus of the healthy volunteers. There was significant T1rho dispersion in both the Achilles tendon and the meniscus. Mean T1rho increased from 2.06 ± 0.23 to 7.85 ± 0.74 msec in normal Achilles tendon and from 7.08 ± 0.64 to 13.42 ± 0.93 msec in normal meniscus when the spin‐lock field was increased from 250 to 1,000 Hz. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

19.
Comprehensive and quantitative measurements of T1 and T2 relaxation times of water, metabolites, and macromolecules in rat brain under similar experimental conditions at three high magnetic field strengths (4.0 T, 9.4 T, and 11.7 T) are presented. Water relaxation showed a highly significant increase (T1) and decrease (T2) with increasing field strength for all nine analyzed brain structures. Similar but less pronounced effects were observed for all metabolites. Macromolecules displayed field-independent T2 relaxation and a strong increase of T1 with field strength. Among other features, these data show that while spectral resolution continues to increase with field strength, the absolute signal-to-noise ratio (SNR) in T1/T2-based anatomical MRI quickly levels off beyond approximately 7 T and may actually decrease at higher magnetic fields.  相似文献   

20.