首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
PurposeTo report early and midterm outcomes of treating thoracic aortic aneurysm (TAA) and aortic dissection (AD) involving zone 1 and zone 0 with multiple parallel stent grafts (PSGs).Materials and MethodsFrom February 2011 to August 2018, 31 of 1,806 patients (1.7%) who underwent thoracic endovascular aortic repair (TEVAR) with double PSGs (DPSGs) (n = 20) or triple PSGs (TPSGs) (n = 11) were retrospectively reviewed. Procedures were performed in high-risk patients who had TAA or AD involving zone 1 or zone 0.ResultsFifteen patients (48.4%) who presented with symptomatic or impending rupture underwent urgent or emergent TEVAR with DPSGs or TPSGs. Nineteen patients (61.3%) were treated for zone 0 disease. Technical and clinical success rates were 70.0% for DPSG cohort and 45.5% for TPSG cohort. Intraoperative type Ia endoleak was observed in 30% of DPSG cohort and 45.5% of TPSG cohort. One patient in the DPSG cohort died of aortic sinus rupture intraoperatively. Minor stroke during the 30-day postoperative period was more frequent in the TPSG cohort (P = .042). Mean duration of follow-up was 28.9 months ± 17.7. The TPSG cohort had a higher incidence of major adverse events (72.7% vs 25.0%, P = .021). The most common adverse events were endoleaks (12.9%), endograft migration (9.7%), PSG stenosis or occlusion (6.5%), retrograde dissection (6.5%), and stroke (3.2%). Endograft migrations were more common in TPSG cohort (27.3%, P = .037). Overall mortality rate was 16.1% (5/31) perioperatively and during follow-up. There were no statistical differences in overall survival and reintervention-free survival.ConclusionsIn the context of TEVAR with multiple PSGs for aortic arch repair, TPSGs may have a high risk of major complications.  相似文献   

2.
PurposeTo evaluate feasibility and efficacy of thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD) associated with retrograde type A intramural hematoma (IMH).Materials and MethodsFrom April 2013 to January 2017, 15 consecutive patients with TBAD associated with retrograde type A IMH who underwent TEVAR were reviewed retrospectively. There was no cardiac tamponade, aortic regurgitation, involvement of coronary artery, or sign of cerebral ischemia in these patients. Enhanced CT was used in 4 patients to diagnose malperfusion of abdominal visceral arteries or lower extremity artery and underwent emergent TEVAR. For the remaining 11 patients, repeated enhanced CT after initial medical treatment within 24 hours from onset of pain showed expansion of IMH in 8 patients or presence of periaortic hematoma in 3 patients. Delayed TEVAR was scheduled for these cases.ResultsSuccessful deployment of the stent graft was achieved in all patients. There were no severe postoperative complications, such as retrograde type A aortic dissection or aortic rupture. Sudden death occurred in 1 patient 3 months after the procedure. Thrombosis of the false lumen, shrinkage of the diameter of the aorta, and complete absorption of the IMH were observed in the remaining patients at a mean follow-up of 19.8 months ± 6.57.ConclusionsTEVAR for treatment of TBAD with retrograde type A IMH is feasible and effective. It represents a treatment option for patients with TBAD associated with type A IMH with a proximal entry tear located in the descending aorta.  相似文献   

3.
PurposeTo investigate dynamic variables obtained from retrospective computed tomography angiography for ability to predict thoracic endovascular aortic repair (TEVAR) outcomes in patients with complicated type B aortic dissection (cTBAD).Materials and MethodsSeventy-nine patients with cTBAD who received TEVAR from March 2009 to June 2018 were retrospectively enrolled. Relative true lumen area (r-TLA) was computed at the level of tracheal bifurcation every 5% of all R-R intervals. Parameters that reflect the state of intimal motion were evaluated, including difference between maximum and minimum r-TLA (D-TLA) and true lumen collapse. The endpoints comprised early (≤ 30 days) and late (> 30 days) outcomes after intervention.ResultsOverall early mortality rate was 13.9% (11/79), and early adverse events rate was 24.1% (19/79). Patients who received TEVAR within 2 days of symptom onset demonstrated the worst outcomes. A longer time of r-TLA < 25% in 1 cardiac cycle (P = .049) and larger D-TLA (P < .001) were correlated to an increased early death. In addition, D-TLA was an independent predictor of early mortality. Area under the curve of D-TLA was 0.849 (95% confidence interval 0.730–0.967) for predicting early mortality and 0.742 (95% CI 0.611–0.873) for predicting early adverse events. Survival and event-free survival rates during follow-up were decreased in the D-TLA > 21.5% group compared with the D-TLA ≤ 21.5% group (all P < .001).ConclusionsLarger D-TLA is correlated with worse postoperative outcomes and might be a crucial parameter for future risk stratification in patients with cTBAD.  相似文献   

4.
PurposeTo analyze the risk factors for access-related adverse events (AEs) of the preclose technique in thoracic endovascular aortic repair (TEVAR).Materials and MethodsNinety-one patients with Stanford type B aortic dissection who underwent the preclose technique in TEVAR between January 2013 and December 2021 were included. According to the occurrence of access-related AEs, the patients were divided into 2 groups: those with AE and those without AE. Age, sex, combined diseases, body mass index, skin depth, femoral artery diameter, access calcification, iliofemoral artery tortuosity, and sheath size were recorded for risk factor analysis. The sheath–to–femoral artery ratio (SFAR), the ratio of the femoral artery inner diameter (in millimeters) to the sheath’s outer diameter (in millimeters), was also included in the analysis.ResultsSFAR was identified as an independent risk factor for AEs using multivariable logistic analysis (odds ratio, 251.748; 95% CI, 7.004–9,048.534; P = .002). The cutoff value of SFAR was 0.85 and was related to a higher incidence of access-related AEs (5.2% vs 33.3%, P = .001), especially to a higher stenosis rate (0.0% vs 21.2%, P = .001).ConclusionsSFAR is an independent risk factor for access-related AEs of preclose in TEVAR with a cutoff value of 0.85. SFAR could be a new criterion for preoperative access evaluation in high-risk patients that may allow the detection and treatment of access-related AEs at the early stage.  相似文献   

5.
Thoracic endovascular aortic repair (TEVAR) for aneurysmal chronic dissection is often complicated by retrograde filling of the false lumen and dissected distal landing zone. A “cheese wire”-style fenestration of the dissection intimal flap can create a landing zone facilitating TEVAR. This technique successfully aided TEVAR in 3 patients with an average age of 57.3 years. Complications included type III endoleak requiring relining and renal artery occlusion requiring stent placement. Average duration of clinical follow-up was 19 ± 4 months. Imaging follow-up was 8 ± 10 months. All patients have survived for more than 1 year without aneurysm enlargement.  相似文献   

6.
PurposeTo evaluate radiographic, laboratory, and clinical factors associated with conservative management (CM) failure in spontaneous rectus sheath hematoma (RSH).Materials and MethodsRetrospective review of 72 patients with spontaneous RSH between 2006 and 2017 was performed. Patients were initially managed conservatively and then divided into 2 groups based on decision to embolize. No differences were found between embolization (n = 32) and CM (n = 40) groups in age (67.5 vs 69.5 y; P = .79), sex (31% vs 38% male; P = .58), body mass index (27.7 vs 25.7 kg/m2; P = .20), or medical comorbidities. Univariate analyses compared initial hemoglobin level, change in hemoglobin level, coagulation parameters, transfusion requirements, hematoma volume, and active extravasation on computed tomographic (CT) angiography between groups. Multivariable logistic regression identified factors predictive of CM failure. A scoring system was then created to predict CM failure.ResultsCM failed in 32 of 72 patients. Multivariable regression identified active extravasation on CT angiography (P = .02), hematoma volume (P = .01), and packed red blood cell (pRBC) transfusion of ≥ 4 U (P = .03) as predictors of embolization. A scoring system using these factors along with maximum rate of hemoglobin decrease yielded a sensitivity of 100% and specificity of 98% in determining need for embolization.ConclusionsCM for RSH was more likely to fail in patients with active extravasation on CT angiography, larger hematoma volume, pRBC transfusion of ≥ 4 U, and higher rate of hemoglobin decrease. Using these parameters, a scoring system was created that achieved high sensitivity and specificity in identifying patients who would require embolization.  相似文献   

7.
PurposeTo evaluate the safety and efficacy of false lumen (FL) stent-grafts in the treatment of postdissection aortic aneurysms.Materials and MethodsEleven patients who underwent endovascular repair using FL stent-grafts from January 2016 to June 2019 were included. Among them, 2 patients had a prior history of type A aortic dissection, whereas 9 had undergone a prior endovascular repair for type B aortic dissection. Computed tomography angiography was performed to evaluate the reintervention and technical success rate, aortic remodeling, and other related aortic complications.ResultsThe mean age of patients was 55.6 ± 10.4 years. Technical success was achieved in all patients, and neither early mortality nor paralysis occurred. In total, 8 visceral branch arteries originating from the FL were reconstructed. The true lumen areas at the celiac axis, superior mesenteric artery, renal artery, and abdominal aortic bifurcation were significantly increased from 230.1 mm2 to 312.3 mm2, 212.1 mm2 to 277.5 mm2, 209.1 mm2 to 291.6 mm2, and 214.4 mm2 to 300.6 mm2, respectively (P < .05). The total diameter of the aorta at the 4 designated levels was stable or had shrunk in all patients. At a mean follow-up of 18.9 ± 7.6 months, 1 patient received re-intervention owing to iliac stent-graft occlusion. No aortic-related mortality occurred.ConclusionsFL stent-grafts can safely and effectively treat patients with postdissection aortic aneurysms. This strategy can be used to promote thrombosis of the FL and aortic remodeling. A larger sample and an extended follow-up period are needed to produce more conclusive results.  相似文献   

8.
PurposeTo evaluate the impact of preemptive inferior mesenteric artery (IMA) embolization on outcomes of endovascular abdominal aortic aneurysm (AAA) repair (EVAR).Materials and MethodsFrom January 2015 to July 2017, all patients undergoing elective EVAR or fenestrated EVAR (F-EVAR) for asymptomatic AAA in a single tertiary hospital were retrospectively included. Three groups of patients were defined: patients with a patent IMA who underwent embolization during EVAR/F-EVAR (group 1), those with a patent IMA who did not undergo embolization during EVAR/F-EVAR (group 2), and those with a chronically occluded IMA (group 3). Preoperative aortic morphology, demographics, and procedural details were recorded. Aneurysmal growth (≥5 mm), reintervention, and overall mortality rates were analyzed using multivariate proportional hazard multivariate modeling. Propensity scores were constructed, and inverse probability weighting was applied to a new set of multivariate analyses to perform a sensitivity analysis.ResultsA total of 266 patients (male, 95% [n = 249]) with a median age of 70 (65–77) years were included, with F-EVAR procedures comprising 87 (32.7%) of the interventions. There were 52, 142, and 72 patients in groups 1, 2, and 3, respectively. Changes in aneurysmal sac size did not differ between groups, nor did overall survival or reintervention rates at 24 months. IMA embolization was not identified as an independently protective factor for aneurysmal growth during follow-up (relative risk [RR] = 2.82/mm [0.96–8.28], P = .060), whereas accessory renal arteries (RR = 5.07/mm [1.72–14.96], P = .003) and a larger preoperative aneurysmal diameter (RR = 1.09/mm [1.03–1.15], P = .004) were independent risk factors for sac enlargement.ConclusionsPreventive embolization of the IMA during EVAR or F-EVAR did not promote aneurysmal sac shrinking or decrease the reintervention rate at 2-year follow-up.  相似文献   

9.
PurposeTo prospectively assess safety and efficacy of prostatic artery embolization (PAE) with bleomycin-eluting microspheres for benign prostatic hyperplasia (BPH) in a canine model.Materials and MethodsTwelve adult male beagles (mean age, 1.6 y ± 0.2; range, 1.2–2.0 y) were randomly assigned to group A (n = 6; PAE with bleomycin-eluting 30–60-μm HepaSphere microspheres) and group B (n = 6; PAE with bland 30–60-μm HepaSphere microspheres) between April 2017 and November 2018. Plasma bleomycin concentration in group A was measured within 7 days. Prostate volume (PV) and ischemic volume after PAE were measured by magnetic resonance imaging. Prostates and adjacent organs were harvested after the last magnetic resonance study and histopathologically examined.ResultsPlasma bleomycin concentration peaked at 10 minutes at 2,055.0 ng/mL ± 606.1 and lasted for 1,440 min at low levels after PAE. PV reduction percentage was greater in group A than in group B at 1 month (74.1% ± 4.3 vs 63.7% ± 3.5; P = .006) and 3 months (61.5% ± 6.7 vs 46.1% ± 3.8; P = .001) after PAE. Proportion of prostate ischemic volume was greater in group A than in group B (75.3% ± 3.0 vs 62.0% ± 7.1; P = .006) at 1 month after PAE. Proportion of prostate ischemic volume at 1 month positively correlated with PV percentage reduction at 3 months in group A (r = 0.840, P = .036) and group B (r = 0.844, P = .035). There were no complications or nontarget embolization to surrounding organs after the procedures.ConclusionsIn a canine model, PAE with bleomycin-eluting microspheres was feasible and well tolerated and caused ischemic necrosis and reduction in PV.  相似文献   

10.
PurposeTo assess safety and feasibility of in situ laser stent graft fenestration to revascularize the left subclavian artery (LSA) during thoracic endovascular repair (TEVAR) of type B aortic dissection (TBAD) with limited proximal landing zones with 5 years of follow-up.Materials and MethodsIn a single-center retrospective study, 130 patients with TBAD with limited proximal landing zones (≤ 1.5 cm) underwent in situ laser stent graft fenestration revascularizing the LSA during TEVAR from April 2014 to April 2019. Outcomes were assessed by CT angiography and clinic visits, including technical success rate, operative time, LSA patency, ischemic events, and late aorta-related complications during follow-up.ResultsMean age of patients was 53 y (range, 33–73 y). Primary technical success rate was 96.9% (126/130). Three chimney stents were placed instead of fenestration, and 1 LSA fenestration was combined with a left common carotid artery (LCCA) chimney stent. Mean operative time was 53 min ± 28 with fluoroscopy time of 40 min ± 15. There were no neurologic complications and no deaths, with a mean duration of hospital stay of 9 d (range, 5–21 d). At a mean follow-up of 42 mo (range, 5–60 mo), there was a 97% primary LSA patency. Four patients had a type I endoleak, which disappeared during follow-up. One LCCA became occluded after 6 months. No type II or III endoleaks were found. Retrograde type A aortic dissection and stent graft–induced new distal entry were not found during follow-up.ConclusionsIn situ laser fenestration to revascularize the LSA during TEVAR of TBAD with limited proximal landing zones was efficient, safe, and feasible based on 5-year follow-up.  相似文献   

11.
PurposeTo investigate the safety and efficacy of the parallel covered stents technique in the treatment of anatomically challenging aortic aneurysms, pseudoaneurysms, and dissections.Materials and MethodsData were retrospectively collected from 16 patients with abdominal aortic diseases who were treated with parallel covered stents (Gore Excluder, n = 14; Medtronic Endurant, n = 2) between January 2016 and July 2018. Patients were treated with this technique if they were unsuitable for either open repair or standard endovascular aortic repair with bifurcated stents. Such unfavorable anatomy included narrow aortic necks (≤18 mm), small vascular access (occluded or ≤6.0 mm), or compressed aortic lumens (≤18 mm). All patients were male, with a mean age of 64.7 ± 13.3 years. For true aneurysms (n = 4) and pseudoaneurysms (n = 4), the mean diameter and length of the proximal necks were 17.5 ± 2.6 mm (range, 14–21 mm) and 51.0 ± 12.5 mm (range, 39–75 mm), respectively. The minimal diameter of true lumen in cases with aortic dissection and penetrating ulcers (n = 8) was 14.8 ± 3.1 mm. Small or occluded femoral access was found in 3 patients.ResultsTechnical success was 100%. Minor type I endoleaks, which were seen on completion angiography in 5 patients, had all resolved within 3 months. There were no perioperative deaths. Postoperative complications included supraventricular tachycardia in 1 patient and pneumonia combined with heart failure in 1 patient. Patency of all stents was observed at a mean follow-up of 21.8 ± 10.1 months.ConclusionsThe parallel covered stents technique appears to offer a feasible solution for abdominal aortic diseases with unfavorable anatomy. Long-term follow-up is needed to further evaluate the safety and efficacy of this technique.  相似文献   

12.
PurposeTo evaluate effectiveness of the polytetrafluoroethylene-covered nitinol mesh microvascular plug (MVP) and compare it with other devices in pulmonary arteriovenous malformation (PAVM) embolization in patients with hereditary hemorrhagic telangiectasia (HHT).Materials and MethodsTwenty-five patients (average age 35 y; range, 15–56 y) with hereditary hemorrhagic telangiectasia (HHT) and de novo PAVM embolization with at least 1 MVP between November 2015 and May 2017 were retrospectively evaluated. Retrospective data were also obtained from prior embolization procedures in the same patient population with other embolic devices dating back to 2008. Technical success, complications, PAVM persistence rates, and category of persistence were analyzed.ResultsIn 25 patients, 157 PAVMs were treated: 92 with MVP, 35 with AMPLATZER vascular plug (AVP), 6 with AVP plus coils, and 24 with coils. The per-PAVM technical success rates were 100% with MVP; 97%, AVP; 100%, AVP plus coils; and 100%, coils. PAVM persistence rates and median follow-up were as follows: MVP, 2% (1/92) (510 d); AVP, 15% (3/20) (1,447 d); AVP plus coils, 20% (1/5) (1,141 d); coils, 46.7% (7/15) (1,141 d). Persistence owing to recanalization for MVP, AVP, AVP plus coils, and coils was 2%, 15%, 0%, and 33%. No difference was found between persistence rates of MVP vs AVP (P = .098). Embolization with a vascular plug (MVP or AVP) with or without coils had a statistically significant lower persistence rate (5.4%) than embolization with coils alone (46.7%) (P = .022).ConclusionsPAVM embolization with MVP had a high technical success rate and a low persistence rate comparable to AVP and lower than coil embolization alone.  相似文献   

13.
PurposeTo evaluate the utility of visualizing preprocedural MR images in 3-dimensional (3D) space using augmented reality (AR) before transarterial embolization of hepatocellular carcinoma (HCC) in a preclinical model.Materials and MethodsA total of 28 rats with diethylnitrosamine-induced HCCs > 5 mm treated with embolization were included in a prospective study. In 12 rats, 3D AR visualization of preprocedural MR images was performed before embolization. Procedural metrics including catheterization time and radiation exposure were compared vs a prospective cohort of 16 rats in which embolization was performed without AR. An additional cohort of 15 retrospective cases was identified and combined with the prospective control cohort (n = 31) to improve statistical power.ResultsA 37% reduction in fluoroscopy time, from 11.7 min to 7.4 minutes, was observed with AR when compared prospectively, which did not reach statistical significance (P = .12); however, when compared with combined prospective and retrospective controls, the reduction in fluoroscopy time from 14.1 min to 7.4 minutes (48%) was significant (P = .01). A 27% reduction in total catheterization time, from 42.7 minutes to 31.0 minutes, was also observed with AR when compared prospectively, which did not reach statistical significance (P = .11). No significant differences were seen in dose–area product or air kerma prospectively.ConclusionsThree-dimensional AR visualization of preprocedural imaging may aid in the reduction of procedural metrics in a preclinical model of transarterial embolization. These data support the need for further studies to evaluate the potential of AR in endovascular oncologic interventions.  相似文献   

14.
PurposeTo investigate differences in outcomes of uterine artery embolization (UAE) for leiomyoma when performed during different phases of the menstrual cycle.Materials and MethodsIn this single-institution retrospective analysis, 111 premenopausal patients (median [range] age, 44 [33–52] years) undergoing UAE for symptomatic leiomyoma between June 2014 and February 2020 were included. Twenty-one patients underwent UAE in the menstrual phase (the early follicular phase), 27 in the late follicular phase, and 63 in the luteal phase. Baseline characteristics and technical and peri-procedural outcomes were compared among groups. Leiomyoma infarction on contrast-enhanced magnetic resonance imaging 1 week after UAE and 4-month outcomes, including changes in the Uterine Fibroid Symptom and Quality of Life questionnaire scores, the volume reduction rates of the uterus and largest leiomyoma, follicle stimulating hormone values, adverse events, and amenorrhea, were compared among groups.ResultsA 4-month follow-up was completed for all patients. No significant differences were observed among groups in baseline characteristics or technical and peri-procedural outcomes. There were no significant differences in the multivariate-adjusted 1-week infarction rates of all leiomyoma volumes (P = .161) or multivariate-adjusted 4-month outcomes, including changes in the Uterine Fibroid Symptom and Quality of Life questionnaire symptoms and total scores (P = .864 and P = .798, respectively), the volume reduction rates of the uterus and the largest leiomyoma (P = .865 and P = .965, respectively), and follicle stimulating hormone values (P = .186) among the groups. No significant differences were noted in the 4-month adverse events (P = .260) or amenorrhea (P = .793) among the groups.ConclusionsThe present study demonstrated no significant differences in the outcomes of UAE for leiomyoma when performed during different phases of the menstrual cycle.  相似文献   

15.
PurposeTo characterize remodeling of conservatively treated isolated mesenteric artery dissection (IMAD) using 3-dimensional (3D) volumetric analysis.Material and MethodsPatients with Type I/II (classification of Yun) treated by conservative therapy between January 2018 and January 2020 were prospectively included. Semiautomatic morphological analysis of the superior mesenteric artery (SMA) included volumetric measurements of the true lumen (TL), false lumen (FL), and overall lumen (OL) and 3D aortomesenteric angles from computed tomography angiography data at admission (T0), 1 month (T1), and 12 months (T12). The SMA morphology of patients with IMAD (n = 15, mean age 53 years ± 7; 87% men) was also compared with that of control individuals (n = 51, mean age 56 years ± 4; 94% men).ResultsA significant reduction in OL volume was observed (P <.001), whereas TL volume remained stable (P =.23). The TL/OL volume ratio significantly increased over time (P =.001) from 53% at T1 to 78% at T12. Aortomesenteric 3D angles at 2, 4, and 6 cm from the ostium showed a progressive decrease toward values observed in the control group (P =.013, P =.002, and P =.027, respectively). At T12, 5 patients (33%) had complete remodeling, and aneurysmal change was observed in 2 patients (<20 mm). Smoking and SMA angle at a distance of 6 cm from the ostium (T0) were the only factors affecting remodeling negatively at T12.ConclusionsOne-year remodeling in IMAD followed an overall decrease in OL volume related to a decrease in FL volume. Smokers and patients with larger SMA angles at baseline showed poorer remodeling. Spontaneous arterial remodeling in IMAD might favor conservative therapy.  相似文献   

16.
PurposeTo report outcomes of yttrium-90 (90Y) radioembolization in patients with unresectable intrahepatic cholangiocarcinoma (ICC).Materials and MethodsRetrospective review was performed of 115 patients at 6 tertiary care centers; 92 were treated with resin microspheres (80%), 22 were treated with glass microspheres (19%), and 1 was treated with both. Postintervention outcomes were compared between groups with χ2 tests. Survival after diagnosis and after treatment was assessed by Kaplan–Meier method.ResultsGrade 3 laboratory toxicity was observed in 4 patients (4%); no difference in toxicity profile between resin and glass microspheres was observed (P = .350). Clinical toxicity per Society of Interventional Radiology criteria was noted in 29 patients (25%). Partial response per Response Evaluation Criteria In Solid Tumors 1.1 was noted in 25% of patients who underwent embolization with glass microspheres and 3% of patients who were treated with resin microspheres (P = .008). Median overall survival (OS) from first diagnosis was 29 months (95% confidence interval [CI], 21–37 mo) for all patients, and 1-, 3-, and 5-year OS rates were 85%, 31%, and 8%, respectively. Median OS after treatment was 11 months (95% CI, 8–13 mo), and 1- and 3-year OS rates were 44% and 4%, respectively. These estimates were not significantly different between resin and glass microspheres (P = .730 and P = .475, respectively). Five patients were able to undergo curative-intent resection after 90Y radioembolization (4%).ConclusionsThis study provides observational data of treatment outcomes after 90Y radioembolization in patients with unresectable ICC.  相似文献   

17.
PurposeTo evaluate the efficacy and safety of transcatheter arterial embolization (TAE) for the treatment of chronic inflammatory joint pain via systematic review and meta-analysis.Materials and MethodsMEDLINE and EMBASE databases were searched for studies reporting outcomes in patients with chronic inflammatory joint pain treated with TAE. Meta-analyses of pain score changes, changes in proportions of patients on analgesic medications, range of motion changes, technical success rates, and adverse events rates were performed. Subgroup analyses were conducted with respect to pain site (knee versus shoulder).ResultsFourteen observational studies, which included 346 patients, were reviewed. The pooled technical success rate was 95.8%, and no major adverse events were observed. The pooled mean difference in pain score at 1 week was 3.1. At 1, 3, and 6 months, the difference in score was 4.0, 4.2, and 5.1, respectively. At 1 year, the difference was 5.5. Subgroup analysis demonstrated that shoulder embolization was associated with greater reduction of pain than knee embolization at 3 and 6 months (P < .001 and P = .018, respectively), whereas there was no significant difference between the sites at 1 month (P = .734). The pooled proportions of patients on analgesic medication at baseline and at 1, 3, 6, and 12 months were 81.1%, 36.3%, 42.3%, 28.2%, and 22.4%, respectively. The pooled estimated increase in the range of motion among patients who underwent shoulder embolization was 55.6° for anterior elevation and 64.7° for abduction.ConclusionsTAE is an effective and safe therapeutic option for patients with chronic inflammatory joint pain.  相似文献   

18.
PurposeTo retrospectively compare technical success and major complication rates of laparoscopically versus radiologically inserted jejunostomy tubes.Materials and MethodsIn this single-institution retrospective study, 115 patients (60 men; mean age, 59.7 y) underwent attempted laparoscopic jejunostomy tube insertion as a standalone procedure during a 10-year period and 106 patients (64 men; mean age, 61.0 y) underwent attempted direct percutaneous radiologic jejunostomy tube insertion during an overlapping 6-year period. Clinical outcomes were retrospectively reviewed with primary focus on predictors of procedure-related major complications within 30 days.ResultsPatients undergoing laparoscopic jejunostomy tube insertion were less likely to have previous major abdominal surgery (P < .001) or to be critically ill (P < .001) and had a higher body mass index (P = .001) than patients undergoing radiologic insertion. Technical success rates were 95% (110 of 115) for laparoscopic and 97% (103 of 106) for radiologic jejunostomy tube insertion (P = .72). Major procedural complications occurred in 7 patients (6%) in the laparoscopic group and in 5 (5%) in the radiologic group (P = 1.0). For laparoscopic jejunostomy tubes, only previous major abdominal surgery was significantly associated with a higher major procedure complication rate (14% [5 of 37] vs 3% [2 of 78] in those without; P = .039). In the radiologic jejunostomy group, only obesity was significantly associated with a higher major complication rate: 20% (2 of 10) vs 3% (3 of 96) in nonobese patients (P = .038).ConclusionsLaparoscopic and radiologic jejunostomy tube insertion both showed high success and low complication rates. Previous major abdominal surgery and obesity may be pertinent discriminators for patient selection.  相似文献   

19.
PurposeTo evaluate the safety and effectiveness of hydrogel-coated coils for vessel occlusion in the body trunk.Materials and MethodsA total of 77 patients with various peripheral vascular lesions, treatable by embolization with coils, were randomized (hydrogel group, n = 38; nonhydrogel group, n = 39). In the hydrogel group, embolization of the target vessel was conducted using 0.018-inch hydrogel-coated coils (AZUR 18; Terumo Medical Corporation, Tokyo, Japan) with or without bare platinum coils. The nonhydrogel group received both bare platinum coils and fibered coils without the use of hydrogel-coated coils.ResultsComplete target vessel occlusion was accomplished in 36 patients in the hydrogel group and 37 patients in the nonhydrogel group. No major adverse events were observed in either group. The median number of coils/vessel diameter and the median total coil length/vessel diameter were significantly larger in the nonhydrogel group than in the hydrogel group (P = .005 and P = .004, respectively). The median embolization length was significantly longer in the nonhydrogel group (31.95 mm) than in the hydrogel group (23.43 mm) (P = .002). If no expansion was assumed, the median packing density in the hydrogel group was 44.9%, which was similar to that in the nonhydrogel group (46.5%) (P = .79). With full expansion assumed, the median packing density in the hydrogel group was 125.7%.ConclusionsHydrogel-coated coils can be safely used for peripheral vascular coil embolization, and hydrogel-coated and conventional coils in combination allow for a shorter embolization segment and shorter coil length.  相似文献   

20.
PurposeTo evaluate the effect of catheter-directed thrombolysis (CDT) with tissue plasminogen activator (tPA) on plasma fibrinogen levels (PFLs) in the setting of acute pulmonary embolism (PE) and the relationship between PFL and hemorrhagic complications.Materials and MethodsA retrospective review of CDT procedures between 2009 and 2019 identified 147 CDT procedures for massive or submassive PE (55.8% males; age, 56.5 ± 14.8 years; 90.5% submassive). All patients received therapeutic anticoagulation during CDT with unfractionated heparin (UFH) (69.4%) or low-molecular-weight heparin (LMWH, 30.6%) infusion. CDT was performed with ultrasound-accelerated thrombolysis (USAT) catheters (n = 98), conventional catheter-directed thrombolysis (CCDT) catheters (n = 34), or a combination of both (n = 15).ResultsThere was a decrease (P = .007) of 15.1 ± 69.4 mg/dl from the initial PFL (376.1 ± 122.7 mg/dl) to the final PFL (361 ± 118.7 mg/dl), which was measured after a mean of 24.1 ± 11.7 hours with a mean tPA dose of 28.3 ± 14.2 mg. The fibrinogen nadir was 327.6 ± 107.1 mg/dl measured 13.4 ± 10.3 hours after initiation of thrombolysis. Of patients with hemorrhagic complications (n = 6), initial, final, and nadir PFL were not significantly lower (P = .053, P = .081, and P = .086, respectively) than the remainder of the cohort. No significant difference was noted in initial and final PFL between the LMWH and UFH groups (P = .2 and P = .1, respectively) or between the CCDT and USAT groups (P = .5 and P = .9, respectively). The UFH group had a lower nadir PFL than the LMWH group (P = .03).ConclusionsDespite a significant drop in PFL during CDT for acute PE, this was not associated with hemorrhagic complications. These findings were not affected by the choice of anticoagulant or catheter delivery system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号