首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 62 毫秒
1.
【目的】通过测量颈椎椎弓根尺寸、进钉点和进钉角度为置入椎弓根螺钉提供依据。【方法】选择2004年12月-2005年10月惠州市中心人民医院骨科收治怀疑颈椎损伤患者60例,男30例,年龄(42.9±18.9)岁,女30例,年龄(42.2±14.9)岁。排除颈椎病理改变。60例患者行颈椎CT扫描,扫描范围C2~T1,扫描电压140kV,200~250mA。【结果】颈椎椎弓根平均内径为1.3~3.3mm,颈椎椎弓根平均外径为4.0~7.0mm,最小的椎弓根宽度在女性颈3椎体,最小的椎弓根外径为3.2mm,最大椎弓根宽为C7,男性为11.1mm,女性为6.6mm。平均内壁皮质骨厚度为1.5~1.9mm,平均椎弓根轴长度29.3~33.7mm,平均椎弓根长轴与中线的夹角40.6°~49.6°,颈椎弓根钉进钉点到中线的垂直距离平均为20.2~23.7mm。【结论】颈椎椎弓根螺钉的置入应行CT测量,螺钉角度接近50°,椎钉角度尽可能侧块的外侧。  相似文献   

2.
目的:观察成人下颈椎前路椎弓根螺钉(Anterior pedicle screw,APS)置入相关的径线和角度,为该术的临床应用提供相关解剖学参数。方法:成人干燥尸体下颈椎(C3~C7)标本22具,分别用手工和CT测量椎弓根最窄处的高度、宽度及内外侧皮质厚度,椎弓根中轴线全长,轴线夹角,并进行统计学分析。随机在CT室资料库中抽取100例成人活体颈椎CT图像,用Mimics软件行三维重建,除以上参数外,还测量进钉点位置的相关数据,计算置钉参数的95%CI。结果:22具标本的相关径线及角度,其手工测量值与CT测量值间无统计学差异。成人活体下颈椎CT图像测量结果通过95%CI的计算,可以得出:C3、C4进钉点位于椎体正中矢状面受术椎弓根对侧 2~3 mm,距椎体上终板平面 6~7 mm,进钉角度为外倾角 46°~ 48°,头倾角 C3:-11°~-12°,C4 -6°~-7°。C5 进钉点位于椎体正中矢状面受术椎弓根同侧旁 1~2 mm,距椎体上终板平面 7~8 mm,进钉角度为外倾角 47°~49°,头倾角 1°~2°。C6、C7 进钉点位于受术椎弓根同侧,正中矢状面旁 4~5 mm,距椎体上终板平面 7.5~8.5 mm,进钉角度为外倾角 C6:40°~42°,C7:36°~38°,头倾角 C6:6°~7°,C7:11°~13°。置钉长度选择 30、32、34 mm 较为适宜,螺钉直径可选择 3.5 mm 或 4.0 mm。结论:本实验证实了CT测量下颈椎APS置入技术相关参数的准确性,同时在国内首次利用大样本研究对该技术置钉参数进行了探索。  相似文献   

3.
下颈椎前路椎弓根螺钉置入的实验研究   总被引:1,自引:0,他引:1  
目的 探讨下颈椎前路椎弓根螺钉置入技术的可行性.方法 取18具成人尸体正常颈椎标本,剔除其周围软组织至清楚显露椎体前壁.CT扫描后,用Mimics软件重建三维模型,并测量C3~C7个体化置钉参数,包括进钉点(即椎弓根中轴线在椎体前壁投影点)、置钉方向(螺钉在横断面和矢状面上的倾斜角度)以及螺钉长度.严格按照测量结果,直视下置入椎弓根螺钉.术后作CT扫描,评价置钉效果.结果 进针点:C3、C4位于置钉椎弓根对侧,正中矢状面旁2~3 mm,距上终板6~7 mm;C5~ C7与置钉椎弓根同侧,其中C5位于正中矢状面旁1~2 mm,距上终板7.0~7.5 mm,C6、C7则为4~5 mm和7.5 ~8.5 mm.置钉方向:理想角度在C3、C4为外倾角46°~47°,头倾角-11°~-7°;在C5外倾角约48°,头倾角接近0°;C6、C7为36°~40°和8~13°.螺钉长度:可选择28、30、32 mm,其直径为3.5 mm.本组共置钉144枚.术后CT示,全部螺钉均经椎体前方置入椎弓根内抵达侧块.其中,有16枚胀破椎弓根外侧皮质,3枚穿破外侧皮质(均发生在C3、C4节段).结论 下颈椎前路椎弓根螺钉置入技术是可行的.  相似文献   

4.
[目的]探讨螺旋CT三维重建对于颈椎椎弓根螺钉通道精确定位的作用.[方法]8具颈椎标本,经螺旋CT(Elscint CT Twin Flash)在1.0 mm厚度断层扫描后,图片送至工作站进行三维重建,明确椎弓根轴线在后关节突的投射点及投射角度,然后咬除椎板及椎弓根在关节凸投射范围以外的骨质,检查三维重建所得的投射点是否在实际的椎弓根关节凸投射范围内,以及是否在小于此半径1.5 mm的同心圆区域内.[结果]三维重建的椎弓根轴线投射点均位于实际所测的椎弓根在关节突处的投射范围之内,有95%在小于此投射半径1.5 mm的同心圆区域内.[结论]经螺旋CT三维重建的椎弓根在关节突处的投射点能基本满足关节突处的精确定位的要求,但考虑螺钉直径时,仍有穿破椎弓根的潜在危险.  相似文献   

5.
1椎弓根螺钉内固定现状 椎弓根是整个椎体最为坚强的骨性部分,经椎弓根螺钉固定是迄今为止最可靠的脊柱后路内固定技术。由于腰椎椎弓根较为宽大且解剖恒定,成为最早应用经椎弓根螺钉固定技术的节段,此技术已为广大骨科医生尤其是脊柱外科医生所熟知。胸椎椎弓根容积尤其是宽度较小,应用椎弓根螺钉固定技术要求较高,但随着CT三维重建技术的广泛应用和新的小直径椎弓根螺钉的出现,胸椎椎弓根螺钉固定技术也在不断成熟与推广。  相似文献   

6.
颈椎椎弓根螺钉瞄准器的研制与实验   总被引:3,自引:0,他引:3  
目的探讨在颈椎椎弓根螺钉内固定中使用瞄准器的准确性与可行性.方法8具颈椎标本,经CT平扫测量C3~C7各椎弓根轴线的内偏角度及在关节突上的投射点,X线双斜位片测量椎弓根轴线的头/尾偏角度及在关节突上的投射点.将标本分为两组,用2.8 mm×30 mm的螺钉置入,第1组用手工按定位点及角度直接置入,第2组采用自行研制的可三维调节角度并可术中矫正的颈椎椎弓根螺钉瞄准器置入螺钉.结果第1组C3~C7共40枚螺钉,13枚螺钉位于椎弓根内,9枚穿破椎弓根,但未侵犯临近结构,18枚有脊髓、神经根或椎动脉损伤;第2组C3~C7共40枚螺钉,36枚位于椎弓根内,4枚穿破椎弓根,但未侵犯临近结构.两组比较差异具有显著性(P<0.01).结论在颈椎椎弓根螺钉的置钉过程中使用瞄准器有利于提高置钉的准确性,可进入临床使用.  相似文献   

7.
颈椎骨折脱位合并脊髓损伤已成为骨科领域中常见的疾患。治疗的恰当与否,往往决定患者的预后。我们将颈椎侧块钢板螺钉与上胸椎椎弓根螺钉联合应用治疗下颈椎骨折脱位,取得了较好的临床效果。  相似文献   

8.
颈椎椎弓根螺钉技术是一种现已在临床普遍展开的技术,但由于它独特的毗邻结构,还尚未成为一种常规内固定技术.本文从颈椎椎弓根的解剖结构,生物力学性能,置钉角度及方法,临床应用等诸多方面综述国内外相关资料,认为颈椎椎弓根螺钉固定技术以其独特的生物力学性能和广泛的适应证,可用于颈椎创伤和非创伤疾患的治疗中,且可以有新技术产生的空间,但其安全性还依赖于影像学以及实验解剖学的发展,也依赖于置钉医生的丰富经验及导航影像导航技术的临床应用.  相似文献   

9.
<正>椎弓根螺钉固定系统是脊柱外科目前使用最广泛的内固定器之一,它利用了椎弓根坚强的力学结构,并通过对三柱固定椎体,提供出色的脊柱稳定性,从而促使脊柱的融合。由于其良好的三维稳定性,目前在脊柱外科应用已有50多年的历史。自1959年Boucher[1]报道了螺钉经椎弓根用于腰骶椎融合的固定获得良好的效果之后,椎弓根螺钉的固  相似文献   

10.
研究背景:因为颈椎解剖结构复杂和椎弓根细小,颈椎椎弓根螺钉置入精确性较差,螺钉置入失误造成神经血管损伤的风险大,临床应用受到限制。北京积水潭医院自2001年10月开始透视辅助颈椎椎弓根螺钉内固定临床应用,自2002年12月开始CT导航辅助颈椎椎弓根螺钉内固定,2005年11月开始术中即时三维电动C型臂导航辅助颈椎椎弓根螺钉内固定。本研究对82例患者进行了前瞻性的队列研究,以评估不同方法颈椎椎弓根螺钉置入的精确性。 目的:对透视、CT导航和术中即时三维电动C型臂导航三种方法辅助颈椎椎弓根螺钉置入的精确性进行对比分析。 方法;对82例颈椎椎弓根螺钉内固定患者进行了前瞻性的队列对照研究。术后CT扫描判断螺钉置入的精确性。优:螺钉完全位于椎弓根内;可:螺钉穿出椎弓根皮质不超过螺钉直径的25%;差:螺钉穿出椎弓根皮质超过25%。 结果:透视组24例患者共置入145枚螺钉,其中优96枚(66.2%)、可37枚(25.5%)、差12枚(8.3%);CT导航组29例患者共置入159枚螺钉, 其中优141枚(88.7%)、可14枚(8.8%)、差4枚(2.5%);术中即时三维电动C型臂导航组29例患者共置入140枚螺钉, 其中优127枚(90.7%)、可13(9.3%)。三组病例均未出现严重神经血管损伤并发症。 结论:透视辅助颈椎椎弓根螺钉置入的精确性在三种技术中最差。CT导航和术中即时三维电动C型臂导航可以提高颈椎椎弓根螺钉置入的精确性。术中即时三维电动C型臂导航由于其操作简便,临床精度高,易于为操作者掌握,具有更好的临床应用前景。  相似文献   

11.
Background  Safe placement of the screws is a critical aspect of trans-pedicle internal fixation, and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is available. The aim of this study was to measure the dimensions of cervical vertebrae C3 to C7 and provide screw length, screw diameter and tilt angle for clinical cervical vertebra trans-pedicle internal fixation.
Methods  Thirty Chinese men and women underwent high-speed spiral computed tomography measurements to obtain data for C3 to C7, and the morphology of the cervical vertebra pedicles was reconstructed.
Results  Reconstructed computer tomography image data revealed that: (1) pedicle sponge width increased incrementally from C3 to C7, (2) pedicle depth was similar for C3 to C7, (3) pedicle angle decreased incrementally from 47.20° to 33.76° for C3 to C7, and (4) pedicle point to midline distance was similar for C3 to C7. There were no statistical differences in morphological data between the right and the left side. Men had statistically larger values than women for all morphological parameters.

Conclusions  Reconstructed computed tomography images can provide useful data for clinical cervical vertebra trans-pedicle internal fixation. The individual measurement of cervical vertebra pedicles is recommended for safe placement of trans-vertebra pedicle screws.

  相似文献   

12.
Hu JH  Lee CI  Yang XY  Qiu GX 《中华医学杂志》2008,88(21):1454-1457
目的 评价颈椎弓根螺钉内固定对颈椎病伴颈椎后凸畸形的矫形的临床疗效和安全性.方法 颈椎弓根螺钉内固定治疗颈椎病伴颈椎后凸畸形17例.测量术前、术后1周及末次随访时颈椎X线中立侧位相后凸Cobb角.术后6个月及末次随访时测量颈椎X线屈伸侧位相,观察融合节段的稳定性.分析术前及术后6个月随访时JOA评分.结果 平均随访时间13.8个月.术前平均颈椎后凸Cobb角为-16.1°,术后1周及末次随访时平均后凸Cobb角分别为-3.3°和-3.8°.术后6个月及末次随访时融合节段稳定.术后6个月随访时JOA评分较术前增加(5.2±1.6,P<0.05),平均改善率为64.3%.未出现神经根、椎动脉和脊髓损伤.结论 颈椎弓根螺钉内固定治疗颈椎病伴颈椎后凸畸形可以获得满意的临床疗效和安全性.  相似文献   

13.
目的探讨胸腰段脊柱爆裂性骨折经伤椎椎弓根植骨、并行椎弓根螺钉固定的治疗效果。方法2008年1月~2011年12月对87例胸腰段爆裂性骨折的患者采用经伤椎椎弓根植骨并椎弓根螺钉固定治疗,手术前后随访观测VAS评分、后凸角度、并发症及神经功能恢复情况。结果术后随访12-48个月,平均(25.3±12.5)个月.无内固定失败的病例及严重并发症发生。大部分患者的神经功能较术前均有1-2级的改善。术后与末次随访时的VAS评分分别为(5.3±0.7)分与(2.8±0.5)分,显著低于术前(P〈0.05);术后与末次随访时的后凸角度分别为(-3.1±6.2)。与(0.7±0.4)°,显著低于术前(P〈0.05)。结论经伤椎椎弓根植骨并椎弓根螺钉固定治疗伤椎胸腰段脊柱爆裂性骨折安全可靠,并发症少,是一种有效的治疗方法。  相似文献   

14.
颈椎椎弓根个体化固定技术治疗261例颈椎疾患临床观察   总被引:2,自引:1,他引:1  
目的:探讨颈椎椎弓根内固定技术在颈椎疾患的个体化方案设计及临床疗效。方法:对261例颈椎疾患,置入1102枚椎弓根螺钉,其中上颈椎疾患83例,下颈椎疾患178例。应用图像存储传输系统(picture archiving and communication system,PACS),采用X线片及64排CT片,对2 000例正常人颈椎椎弓根的冠状位、矢状位、横断位进行精确测量,得出中国人椎弓根的长度、宽度、高度、向内侧倾斜、向头、尾侧倾斜角度的数据值。术前对每位患者拟固定颈椎的椎弓根精确测量,术中应用自制的颈椎椎弓根定位导向器,准确定位入钉点及角度。结果:一次成功1 086枚,16枚经调整后成功,一次成功率98.55%。术后235例患者获12~73个月随访,平均随访时间18.74个月。采用JOA评分标准[1],优131例,良82例,可17例,差5例,优良率88.1%。所有患者X线片示寰椎完全复位,枢椎齿状突骨折处对位良好,均获得骨性融合,未发现钉板断裂。CT片示螺钉与椎动脉及脊髓位置关系良好。下颈椎患者中,15例患者16枚椎弓根螺钉术后拍片位置不理想,行二次手术调整,无脊髓及椎动脉损伤。119例骨折脱位的患者中117例完全复位,融合率为98.3%。结论:应用椎弓根技术治疗颈椎疾患可以获得即刻三维稳定,融合率高,是一种可行值得推广的方法。  相似文献   

15.
[目的 ]评价各种投射位的X线平片对椎弓根螺钉位置的准确性判定 .[方法 ]对 4例病人的 16枚椎弓根螺钉均在术中、术后拍X线侧位及双斜位片 ,术后做CT扫描 .[结果 ]侧位片无错位钉检出率 ,双斜位的为 6 % ,CT的为 12 % .[结论 ]侧位加双斜位是目前条件下最可靠的术中钉位判定手段  相似文献   

16.
目的:研究颈椎肿瘤行后路肿瘤切除、植骨融合、徒手置入椎弓根螺钉是否安全可行。方法:对吉林大学第一医院2008年1月~2011年4月内10例颈椎肿瘤患者(9例良性,1例为肝癌骨转移)行此手术治疗。结果:10例患者共置螺钉67颗,61颗置入准确,6颗穿破椎弓根皮质,准确率为91%。10例患者术中均有大量出血。4例术后出现神经症状,其中1例术后3周症状消失,另3例术后神经功能逐渐代偿,其余未发现神经血管症状。初置钉时有3颗螺钉松动,经处理后术后半年内复查均无拔钉现象。结论:颈椎肿瘤行后路切除、植骨融合、徒手置入椎弓根螺钉是可行的。熟练掌握颈椎解剖,做好充分术前准备,置钉个体化以及精细的手术操作对手术的成败起关键作用。  相似文献   

17.
目的:探讨3种颈椎前路钉板系统(Orion、Codman、Window)在颈椎前路单椎间减压植骨融合模型中的生物力学为临床应用提供生物力学依据。方法:采用6具小牛颈椎标本,测定其正常颈椎相应节段的活动范围(ROM),制成模型,依次测试Orion、Codman、Window固定后颈椎相应节段的ROM。结果:3种钢板固定后在前屈、后伸、旋转时的ROM均比正常小,其中前屈时3种钢板与正常颈椎相比差异有显著性意义(P<0.05)。后伸时Codman、Window与正常颈椎相比差异有显著性意义(P<0.05)。Orion与正常颈椎差异无显著性意义(P>0.05)。旋转侧屈时3种钢板与正常颈椎差异均无显著性意义(P>0.05)。3种钢板之间差异无显著性意义(P>0.05)。结论:支持3种钢板在颈椎在单椎间减压植骨融合中应用。  相似文献   

18.
李波  吴畏  沈钧国  吴光宇 《海南医学》2014,(15):2222-2224
目的:观察椎弓根植骨联合短节段椎弓根螺钉内固定治疗老年胸腰椎骨折的疗效及安全性。方法选取采用椎弓根植骨联合短节段椎弓根螺钉内固定治疗的老年胸腰段骨折病例进行回顾性分析,共纳入56例研究对象。手术前后及随访期间均行X线检查,观察术后植骨情况、并发症发生率及神经功能恢复情况,评估手术前后伤椎椎体前缘高度值、Cobb's角、椎管内占位变化等。结果手术时间平均为(136±41) min;术中平均出血量(250±61) ml,术后无感染、骨不连等严重并发症。随访时间6~60个月,术后影像学检查伤椎高度、Cobb's角、椎管内占位较术前获得显著改善(P〈0.05),术后1周与末次随访时差异无统计学意义。术后ASIA分级与术前比较差异有统计学意义(P〈0.05),神经功能获得1~2级改善。结论短节段椎弓根螺钉内固定可重建脊柱稳定性,椎弓根植骨可填补伤椎复位后的椎体缺损,维持前中后三柱稳定性,是治疗老年胸腰椎骨折的有效方法。  相似文献   

19.
彭亦良  张泽华  吴雪辉  代飞  周强 《西部医学》2010,22(8):1397-1400
目的观察经后路椎弓根钉棒系统内固定治疗胸腰椎骨折的临床疗效。方法应用椎弓根钉棒系统内固定治疗胸腰椎骨折68例,采用Frankel分级结合X线片、CT影像表现判断疗效。结果随访6-54个月,随访期间有2例椎弓根螺钉松动,1例后期出现断裂并完整取出。椎体前、后缘高度分别从术前平均51.4%和75.8%恢复到93.6%和96.5%,Cobb′s角由术前25.8°降低复到末次随访的6.4°。CT示椎管截面积术前为42.6%,末次随访为92.9%。各项指标与术前比较差异有显著性意义(P〈0.05),患者术后神经功能按Frankel分级大多数都有1-3级提高,腰背部疼痛也获得不同程度改善。结论后路椎弓根钉棒系统内固定是治疗胸腰椎骨折的一种有效方法 ,其具有创伤小、易控制和固定稳定等优点。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号