首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PURPOSE: To evaluate excimer laser in situ keratomileusis (LASIK) for hyperopia and its predictability. METHODS: We performed a retrospective study of 100 eyes that had LASIK for hyperopia to assess predictability and long-term stability of refractive results. The Chiron Automated Corneal Shaper was used to create the flap and the Keracor 117CT Chiron-Technolas excimer laser with the plano-scan program was used to ablate all corneas. RESULTS: Mean baseline spherical equivalent manifest refraction was +4.50 +/- 1.73 D (range, +1.25 to +8.50 D). Six months after LASIK, mean manifest spherical equivalent refraction was +0.72 +/- 1.87 D (range, -1.75 to +2.50 D), at 1 year, +0.88 +/- 1.73 D (range, -1.25 to +2.50 D), and at 2 years, +0.85 +/- 1.74 D (range, -0.50 to +2.75 D). Two years after LASIK, 45 eyes (74%) were within +/-1.00 D of intended correction and within +/-1.00 D of emmetropia. Uncorrected visual acuity was 20/40 or better in 50 eyes (82%) at 2 years; 29 eyes (37%) saw 20/20 or better. Undercorrection occurred more frequently in eyes with preoperative keratometric power of more than 45.00 D, when ablation zones less than 6 mm were used and when higher amounts of hyperopic correction were required. CONCLUSION: LASIK with the Keracor 117CT excimer laser appears to be an effective and safe procedure to correct hyperopia. Preoperative keratometric power, amount of hyperopia, and ablation zone diameter affect the efficacy and long-term stability of the procedure.  相似文献   

2.
PURPOSE: To assess the efficacy, predictability, stability, and safety of laser in situ keratomileusis (LASIK) in patients with hyperopia and to evaluate the visual and refractive results of the procedure. METHODS: LASIK was performed on 85 eyes of 53 patients for correction of hyperopia, with a preoperative mean manifest spherical equivalent refraction of +3.31 +/- 0.69 D (range, +1.25 to +5.00 D) and mean refractive astigmatism of +0.91 +/- 1.06 D (range, 0 to +3.00 D). The Carriazo-Barraquer (Moria) manual microkeratome was used to create the corneal flap, and laser ablation was performed using the Technolas Keracor 117C excimer laser with an ablation zone diameter of 6.0 mm and a transition zone diameter to 9.0 mm. Follow-up was 12 months for all patients. RESULTS: Refraction was stable by 3 months after surgery. At 1 year after LASIK, the mean manifest spherical equivalent refraction was +0.43 +/- 0.57 D (range, -1.25 to +2.00 D) and refractive astigmatism was reduced to a mean of 0.36 +/- 0.30 D (range, 0 to 1.00 D). Fifty-two eyes (61.2%) had a manifest spherical equivalent refraction within +/- 0.50 D of emmetropia, and 76 eyes (89.4%) were within +/- 1.00 D. Uncorrected visual acuity was 20/20 in 21 eyes (24.7%) and 20/40 or better in 79 eyes (92.9%). Spectacle-corrected visual acuity was reduced by two lines in one eye (1.2%) and improved by two lines in five eyes (5.9%). There were no significant complications. CONCLUSION: LASIK was an effective, safe, and predictable procedure for the correction of hyperopia up to +5.00 D and hyperopic astigmatism up to +3.00 D with the Technolas Keracor 117C excimer laser. The large size of the corneal flap obtained by the Carriazo-Barraquer (Moria) manual microkeratome facilitated laser ablation entirely in the exposed corneal stromal bed.  相似文献   

3.
PURPOSE: To evaluate safety, predictability, efficiency, and long-term stability of laser in situ keratomileusis (LASIK) for spherical hyperopia. METHODS: This study was a retrospective 5-year analysis of 67 patients (125 eyes) who had LASIK for spherical hyperopia; preoperative mean manifest spherical equivalent refraction was +3.84+/-1.13 D (range +1.00 to +6.50 D) and mean astigmatism was 0.37+/-0.27 D (range 0 to 1.00 D). Preoperative spherical equivalent refraction for the low hyperopia group was +1.00 to +2.75 D; medium hyperopia group, +3.00 to +4.25 D, and high hyperopia group, +4.50 to +6.50 D. All surgeries were performed using the scanning Chiron Technolas Keracor 117C excimer laser. Uncorrected and best spectacle-corrected visual acuity, predictability, long-term stability of refraction, and complications were analyzed. RESULTS: At 5 years after hyperopic LASIK, mean spherical equivalent refraction for the low hyperopia group was +0.48D+/-0.79 D; medium hyperopia group, +1.52+/-1.45 D; high hyperopia group C, +3.39+/-1.98 D. The percentage of eyes with a spherical equivalent refraction within +/-0.50 D of emmetropia for the low hyperopia group was 63% (37 eyes); medium hyperopia group, 42% (20 eyes); high hyperopia group, 22% (4 eyes). Eyes with chronic dry eye symptoms had a mean difference in spherical equivalent refraction from target refraction of +1.43 D compared with +0.84 D for eyes without dry eye symptoms. Five eyes (4%) lost 2 lines of BSCVA at 5 years. CONCLUSION: LASIK was safe, effective, and stable for primary hyperopia between +1.00 and +3.00 D. Higher amounts of hyperopia had poor long-term stability, especially eyes with more than +4.25 D. Chronic dry eye symptoms were associated with regression over time.  相似文献   

4.
PURPOSE: To evaluate the effectiveness, predictability, and safety of laser in situ keratomileusis (LASIK) for correction of hyperopia and hyperopic astigmatism. METHODS: Fifty-four hyperopic eyes of 35 patients with a spherical equivalent refraction between +1.00 and +6.00 D were followed for at least 12 months following LASIK. All surgery was performed with the scanning Chiron Technolas Keracor 117C excimer laser. Data on uncorrected and spectacle-corrected visual acuity, predictability, stability of refraction, and complications were analyzed. RESULTS: At 12 months, the average residual refraction was +0.29 +/- 0.78 D; 83.3% of eyes (45 eyes) were in the range of +/- 1.00 D and 61.1% of eyes (33 eyes) were within +/- 0.50 D of emmetropia. Fifty eyes (92.6%) had uncorrected visual acuity of 20/40 or better and 34 (63.0%) eyes had 20/20 or better. One eye (1.9%) lost two lines of best spectacle-corrected visual acuity and two eyes (3.7%) gained two or more lines. Two patients (two eyes, 3.7%) had complaints of halos and one patient (one eye, 1.9%) had glare at 12 months after LASIK for hyperopia. CONCLUSIONS: LASIK was used to treat hyperopia from +1.00 to +6.00 D with good predictability and safety. Primary and second hyperopia require different nomograms, according to our experience.  相似文献   

5.
PURPOSE: We evaluated the efficacy, predictability, stability, and safety of laser in situ keratomileusis (LASIK) for hyperopia and hyperopic astigmatism. METHODS: A retrospective study was performed for 92 eyes of 62 consecutive patients to evaluate uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA) and manifest refraction before and 3 and 6 months after LASIK (Moria LSK-ONE microkeratome, Nidek EC-5000 excimer laser). Eyes were divided into groups: Group 1 (low hyperopia) for spherical correction of +1.00 to +3.00 D (22 eyes), Group 2 (low hyperopic astigmatism) for toric correction with spherical equivalent refraction of +1.00 to +3.00 D (18 eyes), Group 3 (moderate hyperopia) for spherical correction of +3.25 to +6.00 D (10 eyes), and Group 4 (moderate hyperopic astigmatism) for toric correction with spherical equivalent refraction between +3.25 and +6.00 D (18 eyes). RESULTS: At 3 and 6 months after LASIK, 68 eyes (73.9%) were available for follow-up examination. Percentage of eyes with a spherical equivalent refraction within +/-0.50 D of emmetropia for Group 1 was 54.5% (12 eyes); Group 2, 50% (9 eyes); Group 3, 40% (4 eyes), and Group 4, 38.8% (7 eyes). UCVA > or =20/20 in Group 1 was 14% and in Groups 2, 3, and 4, 0%. One eye (5.5%) lost two lines of BSCVA. CONCLUSION: LASIK with the Moria LSK-ONE microkeratome and the Nidek EC-5000 excimer laser reduced low and moderate hyperopia and was within +/-0.50 D of target outcome in approximately 50% of eyes. Undercorrection was evident in all groups. The procedure was safe.  相似文献   

6.
PURPOSE: To evaluate factors that influence retreatment results after primary hyperopic LASIK. METHODS: Restrospective study of 86 eyes of 61 patients that underwent LASIK to correct primary hyperopic spherical equivalent refraction and a second hyperopic retreatment due to undercorrection. All procedures were performed with the Technolas Keracor 217C excimer laser, lifting the preexisting flap for the retreatment. Preoperatively, under cycloplegia, mean spherical equivalent refraction of the series was +3.05 +/- 0.99 diopters (D). RESULTS: At last follow-up, mean spherical equivalent refraction was -0.07 +/- 0.50 D. Efficacy of the retreatment procedure was better when the primary LASIK attempted spherical equivalent refraction correction was < +3.00 D (P < .05). Safety of retreatment was lower when attempted spherical equivalent refraction correction was > +1.00 D (P < .05) and when attempted spherical equivalent refraction correction of both procedures combined was >+4.00 D (P < .05). CONCLUSIONS: Efficacy, safety, and predictability of retreatments secondary to undercorrection after primary hyperopic LASIK may be affected depending on the amount of diopters corrected in the primary procedure, in the retreatment procedure, and in both primary and retreatment procedures combined.  相似文献   

7.
PURPOSE: Laser thermal keratoplasty (LTK) has its main indication in the correction of hyperopia. However, regression of refractive effect following LTK is a limitation. Laser in situ keratomileusis (LASIK) may provide a good alternative to correct residual refractive errors. METHODS: Fifty hyperopic eyes with varying amounts of regression after LTK underwent LASIK. The Chiron Automated Corneal Shaper microkeratome was used to make a flap of 160 microm and laser ablation was performed with the Technolas 217 Planoscan excimer laser. Postoperative follow-up was 6 months. RESULTS: Mean spherical equivalent refraction improved from +2.92+/-1.60 D to +0.36+/-1.48 D. Mean best spectacle-corrected visual acuity changed from 0.78+/-0.14 before LASIK to 0.76+/-0.16 D 6 months after LASIK. Mean uncorrected visual acuity changed from 0.37+/-0.16 to 0.66+/-0.24. Forty-two percent (21 eyes) were within +/-0.50 D of intended correction, 60% (30 eyes) were within +/-1.00 D, and 76% (38 eyes) were within +/-2.00 D. After LASIK, confluent haze between previous LTK spots was observed in most eyes, as LASIK ablation took place at the sites of the LTK spots. CONCLUSIONS: LASIK after LTK is a good alternative for hyperopic regression. Predictability and efficacy are less than with primary LASIK for hyperopia, but the procedure is equally safe.  相似文献   

8.
PURPOSE: To prospectively evaluate the safety, efficacy, predictability, and long-term stability of hyperopic laser in situ keratomileusis (LASIK) using the Star S2 excimer laser (Visx). SETTING: Department of Ophthalmology, Stanford University School of Medicine, Stanford, California, USA. METHODS: This study evaluated 41 eyes of 27 patients who had LASIK for the correction of spherical hyperopia. Patients were divided into 3 groups based on preoperative cycloplegic refraction: low hyperopia (less than +2.00 diopters [D]), medium hyperopia (+2.00 to +4.00 D), and high hyperopia (more than +4.00 D). RESULTS: In all eyes, the mean preoperative spherical equivalent (SE) was +2.53 D (range +0.75 to +5.25 D) and the mean attempted SE was +2.58 D (range +0.75 to +5.25 D). At the last visit (mean 5.29 years), the mean SE was +0.44 D +/- 0.69 (SD) in the low hyperopia group, +0.58 +/- 0.56 D in the medium hyperopia group, and +0.59 +/- 1.18 D in the high hyperopia group. The percentage of eyes within +/-1.00 D of emmetropia was 82.4%, 75.0%, and 66.7%, respectively (68.9% overall). The uncorrected visual acuity was 20/40 or better in 100% of eyes in the low hyperopia group, 91.7% in the medium hyperopia group, and 66.7% in the high hyperopia group (87.8% overall). The hyperopic shift between 1 year and the last visit was +0.18 D, +0.30 D, and +0.55 D, respectively (+0.40 D overall; range -1.25 to +2.63 D). CONCLUSIONS: Hyperopic LASIK using the Star S2 excimer laser was safe, effective, and predictable for hyperopia up to +4.10 D (mean of high group). A mild regression of the refractive effect was seen over the 5-year follow-up.  相似文献   

9.
PURPOSE: To evaluate safety, predictability, efficacy, and stability of laser in situ keratomileusis (LASIK) for spherical hyperopia and hyperopia with astigmatism. METHODS: In this retrospective study we analyzed the results of 23 eyes of 23 patients who had LASIK for spherical hyperopia (preoperative cylinder < or = 0.75 D) and 44 eyes of 44 patients who had LASIK for hyperopia with astigmatism; (Bausch & Lomb Hansatome microkeratome with a 180-microm plate and a suction ring for a 9.5-mm flap diameter; Asclepion-Meditec MEL 70 G-scan flying spot laser with a 1.8-mm Gaussian beam). RESULTS: In Group 1 (spherical hyperopia), mean preoperative spherical equivalent refraction was +4.88 +/- 2.13 D (range +2.13 to +9.63 D); in Group 2 (hyperopic astigmatism), +4.33 +/- 2.15 D (range +0.50 to +9.50 D). One year after LASIK, mean spherical equivalent refraction was +0.30 +/- 0.90 D (range -0.75 to +2.50 D) in Group 1 and +0.29 +/- 1.27 D (range -3.25 to +3.25 D) in Group 2. In Group 1, 78%, and in Group 2, 42% were within +/- 0.50 D. In Group 1, no eyes lost two or more lines, and one eye (6%) lost one line of best spectacle-corrected visual acuity at 1 year. In Group 2, one eye (4%) lost one line and one eye (4%) lost more than two lines at 1 year. Uncorrected visual acuity of 20/40 or better was achieved in 83% (Group 1) vs. 62% (Group 2) at 1 year; these values improved to 100% vs. 71% for corrections up to +6.00 D. CONCLUSIONS: LASIK with the Meditec MEL 70 G-Scan flying spot laser seemed to be safe and effective for hyperopia and hyperopia with astigmatism for corrections up to +6.00 D. Large flap diameters are necessary to avoid epithelial ingrowth.  相似文献   

10.
Bitoric laser in situ keratomileusis for astigmatism   总被引:2,自引:0,他引:2  
PURPOSE: To evaluate the efficacy, predictability, and safety of bitoric laser in situ keratomileusis (LASIK) for the correction of mixed astigmatism. SETTING: Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS: This prospective study included 28 eyes of 21 patients with mixed astigmatism who had bitoric LASIK using the Hansatome microkeratome (Bausch & Lomb Surgical) and the Chiron Technolas 217 excimer laser (Bausch & Lomb Surgical). The main outcome measures were uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), defocus equivalent, blur strength, and refraction. RESULTS: Six months after bitoric LASIK, the mean UCVA was 0.70 +/- 0.23 (SD). The percentage of eyes with a UCVA of 20/40 or better was 78.6% and of 20/20, 21.4%. There was a statistically significant increase in the mean BCVA from 0.71 +/- 0.19 before surgery to 0.83 +/- 0.15 at 6 months (P =.0004). Three eyes (10.7%) lost 1 line of BCVA; 19 eyes (67.9%) gained 1 or more lines. The mean preoperative astigmatism of -4.04 +/- 1.13 diopters (D) was reduced to -0.67 +/- 0.79 D after surgery. The defocus equivalent was less than 1.00 D in 75.0% of eyes and less than 0.50 D in 64.3%. Vector analysis showed that the mean achieved correction was 97.4% of the intended correction. CONCLUSIONS: Bitoric LASIK was a safe, effective, and predictable procedure in the treatment of mixed astigmatism. It is a means to improving BCVA in a significant percentage of patients.  相似文献   

11.
PURPOSE: To evaluate the safety and efficacy of laser in situ keratomileusis (LASIK) for correction of high astigmatism after penetrating keratoplasty, and to assess the refractive results and predictability of the procedure. METHODS: LASIK was performed on 19 patients (19 eyes) with high astigmatism after penetrating keratoplasty, using the Chiron Automated Corneal Shaper and the Chiron-Technolas Keracor 116 excimer laser. The amount of preoperative refractive astigmatism ranged from 6.50 to 14.50 D (mean, 9.21 +/- 1.95 D) and the spherical component of manifest refraction ranged from -7.00 to +1.25 D (mean, -2.14 +/- 2.11 D). All patients completed a minimum follow-up of 12 months. RESULTS: Refraction was stable after 3 months. At 1 year after LASIK, the amount of refractive astigmatism was reduced to a mean of 1.09 +/- 0.33 D (range, 0.50 to 1.75 D), with 57.9% of the eyes within +/- 1.00 D of refractive astigmatism. The mean percent reduction of astigmatism was 87.9 +/- 3.7%. The postoperative spherical component of manifest refraction ranged from -1.00 to +1.75 D with a mean of +0.43 +/- 0.82 D. Vector analysis showed that the mean amount of axis deviation was 1.1 +/- 1.3 degrees and the mean percent correction of preoperative astigmatism was 92.6 +/- 8.4%. There were no intraoperative complications. Spectacle-corrected visual acuity was not reduced in any eye, and improved by 2 or more lines in 42.1% of eyes after LASIK. CONCLUSION: LASIK with the Chiron-Technolas Keracor 116 excimer laser was effective for correction of both astigmatism and myopia after penetrating keratoplasty. The procedure proved to be safe and gave fairly predictable and stable refractive results.  相似文献   

12.
PURPOSE: To evaluate the efficacy, stability, and safety of laser in situ keratomileusis (LASIK) for hyperopia and hyperopic astigmatism using a prospective clinical trial. METHODS: LASIK was performed using the Automatic Corneal Shaper and the Keracor 117C excimer laser on 192 hyperopic eyes with astigmatism of less than 1.00 D (spherical group) and 164 hyperopic eyes with corneal astigmatism of 1.00 to 7.50 D (toric group). RESULTS: At 12 months after LASIK, 110 eyes were available for follow-up examination. In low spherical hyperopia (+1.00 to +3.00 D), 13 eyes (55%) were within +/-0.50 D of emmetropia and none lost 2 or more lines of spectacle-corrected visual acuity. In low toric hyperopia (+1.00 to +3.00 D), 14 eyes (61%) were within +/-0.50 D and none lost 2 or more lines of spectacle-corrected visual acuity. In moderate spherical hyperopia (+3.10 to +5.00 D) 9 eyes (44%) were within +/-0.50 D and none lost 2 or more lines of spectacle-corrected visual acuity and in moderate toric hyperopia (+3.10 to +5.00 D) 5 eyes (36%) were within +/-0.50 D and 2 eyes (14%) lost 2 or more lines of spectacle-corrected visual acuity. In high spherical hyperopia (+5.10 to +9.00 D), 6 eyes (38%) were within +/-0.50 D and 2 eyes (13%) lost 2 or more lines of spectacle-corrected visual acuity, and in high toric hyperopia (+5.10 to +9.50 D) 4 eyes (31%) were within +/-0.50 D and 2 eyes (15%) lost 2 or more lines of spectacle-corrected visual acuity. CONCLUSIONS: LASIK seems to be reasonably effective and safe in spherical hyperopia of +1.00 to +5.00 D but less effective for hyperopic astigmatism. For hyperopia greater than +5.00 D, loss of spectacle-corrected visual acuity occurred in a significant number of eyes and accuracy was sufficiently poor to advise against LASIK in these eyes.  相似文献   

13.
PURPOSE: To analyze the results of secondary laser in situ keratomileusis (LASIK) for residual myopia after primary LASIK. SETTING: Dr. Agarwal's Eye Hospital, Chennai, India. METHODS: A retrospective study of 50 eyes of 29 patients who had a secondary LASIK procedure was carried out. After a mean follow-up of 5.84 months +/- 3.24 (SD) after the primary procedure, the mean myopic residual refraction was -4.30 +/- 1.83 diopters (D). In 10 eyes, the primary corneal flap was lifted by blunt dissection. In 40 eyes, the flap was made with a second cut. The secondary LASIK was performed using the Chiron Technolas Keracor 217 excimer laser and the Automated Corneal Shaper microkeratome (Bausch & Lomb). RESULTS: The mean follow-up was 16.58 +/- 3.06 months. At 12 months, the mean spherical equivalent was -0.45 +/- 0.68 D (P <.05). Thirty-one eyes were emmetropic, 13 eyes were within +/-1.00 D of emmetropia, and 5 eyes were within +/-2.00 D. The mean uncorrected visual acuity improved from 20/80 (range 20/60 to 20/200) to 20/40 (range 20/20 to 20/200) (P <.005). Seventeen eyes gained 1 line of best spectacle-corrected visual acuity; 1 eye lost 1 line because of a decentered ablation with an induced postoperative astigmatism of -3.50 D cylinder. No sight-threatening complications such as a free cap, flap irregularity, corneal ectasia, or retinal complication occurred postoperatively. Epithelial ingrowth developed in 5 eyes and corneal thinning, in 1 eye. Three eyes had night glare. CONCLUSION: Secondary LASIK was a safe, stable, and effective method for the treatment of residual myopia after primary LASIK.  相似文献   

14.
PURPOSE: To evaluate the visual and refractive results of laser in situ keratomileusis (LASIK) retreatment on eyes with residual myopia with or without astigmatism. METHODS: LASIK retreatment was performed on 35 eyes of 23 patients for correction of residual myopia, with or without astigmatism, with a mean manifest spherical equivalent refraction of -2.17+/-0.82 D (range, -1.00 to -3.87 D) and mean refractive astigmatism of -0.55+/-0.61 D (range, 0 to -1.75 D). Retreatment was performed 3 to 18 months after primary LASIK (mean, 5.1+/-2.6 mo). The corneal flap of the previous LASIK was lifted and laser ablation was performed using the Chiron-Technolas Keracor 116 excimer laser. Follow-up was 12 months for all eyes. RESULTS: At 1 year after retreatment, manifest spherical equivalent refraction was reduced to a mean -0.23+/-0.28 D (range, 0 to -0.87 D), and refractive astigmatism was reduced to a mean -0.16+/-0.25 D (range, 0 to -0.75 D). Thirty-two eyes (91.5%) had a manifest spherical equivalent refraction within +/-0.50 D of emmetropia, and 33 eyes (94.3%) had 0 to 0.50 D of refractive astigmatism. Uncorrected visual acuity was 20/20 or better in 11 eyes (31.4%). Spectacle-corrected visual acuity was not reduced in any eye after retreatment. There were no significant complications. CONCLUSION: LASIK retreatment was effective for correction of residual myopia or astigmatism after primary LASIK. Refractive results were predictable with good stability after 3 months. Lifting the flap during LASIK retreatment was relatively easy to perform and did not result in visual morbidity in eyes treated from 3 up to 18 months after primary LASIK.  相似文献   

15.
PURPOSE: To analyze the effect of preoperative higher order aberrations on postoperative sphere and cylinder outcome. METHODS: Three hundred thirty myopic eyes (mean: -3.32 +/- 1.54 diopters [D], range: -1.0 to -7.0 D) treated with customized ablation using the Technolas 217z laser (Bausch & Lomb) were followed through 6 months after LASIK. Pre- and postoperative visual acuity, higher order root mean square (RMS), third order RMS, and spherical aberration were compared to study the safety and efficacy of the treatment. The relationship between preoperative higher order aberrations and manifest refraction after LASIK was analyzed. RESULTS: Following LASIK, 91.5% of eyes obtained an uncorrected visual acuity of > or = 20/20 and 70.3% of eyes obtained 20/16 without retreatment; 99% had a best spectacle-corrected visual acuity of > or = 20/20 (75.9% of eyes were within +/- 0.50 D). Mean value of significant increase in postoperative higher order aberrations was 0.12 +/- 0.18 microm (P<.0001). Increased spherical aberration was associated with increased myopia treatment (P<.0001). Greater positive spherical aberration after LASIK was significantly correlated to postoperative hyperopia (overcorrection). Change in third order RMS was significantly correlated to change in spherical equivalent refraction among eyes with postoperative astigmatism (P<.0001). CONCLUSIONS: With the Bausch & Lomb Technolas 217z Zyoptix software, treatment of higher order aberrations, especially third order (coma and trefoil) and spherical aberration, significantly improved postoperative refractive status.  相似文献   

16.
PURPOSE: To evaluate effectiveness, safety, predictability, and short-term stability of laser in situ keratomileusis (LASIK) using the LaserSight Compac-200 Mini excimer laser with software version 9.0, for all refractive errors. METHODS: One hundred fifty consecutive patients (300 eyes) that received bilateral LASIK for myopia, hyperopia, and astigmatism were studied prospectively. A new 9.0 software version applying a modified nomogram that takes advantage of bilateral surgery was used. Follow-up at 6 months was available for 267 eyes (89%). RESULTS: Six months postoperatively, 131 eyes (96.32%) in the low to moderate myopia group (-1.00 to -5.99 D; n=136) had a spherical equivalent refraction within +/-1.00 D, and 123 eyes (90.44%) were within +/-0.50 D of emmetropia. In the high to extreme myopia group (-6.00 to -25.00 D; n=114), 97 eyes (87.08%) had a spherical equivalent refraction within +/-1.00 D and 78 eyes (68.42%) were within +/-0.50 D of emmetropia. In the hyperopia group (+1.00 to +6.00 D; n=50), 44 eyes (88%) had a postoperative spherical equivalent refraction within +/-1.00 D, and 31 eyes (62%) were within +/-0.50 D of emmetropia. Mean change in spherical equivalent refraction at 6 months was less than -0.50 D in the low to high myopia groups and -1.16 +/- 0.55 D in the extreme myopia group. At 6 months follow-up, uncorrected visual acuity was 20/20 or better in 73 eyes (54%) in the low to moderate myopia groups and 21 eyes (18%) in the high to extreme myopia groups. In the hyperopia group at 6 months follow-up, uncorrected visual acuity was 20/20 or better in 31 eyes (62%) and 20/40 or better in 41 eyes (82%). Only two eyes had a temporary loss of two or more lines of spectacle-corrected visual acuity due to corneal folds that were surgically treated. Six months after LASIK, no eye had lost any lines of best spectacle-corrected visual acuity in this series. CONCLUSIONS: Our modified LASIK nomogram with the 9.0 software of the LaserSight 200 excimer laser (with a larger and smoother ablation pattern) resulted in safe and effective outcomes for the treatment of low to high myopia, astigmatism, and hyperopia.  相似文献   

17.
PURPOSE: To assess the efficacy, predictability, and safety of LASIK for the surgical correction of low to moderate hyperopia and hyperopic astigmatism using the NIDEK EC-5000 excimer laser. METHODS: In a multicenter United States Food and Drug Administration (FDA) regulated study of LASIK, 7 centers enrolled 293 eyes with manifest refraction sphere that ranged from +0.50 to +6.00 diopters (D) with or without astigmatism up to 3.00 D. The intended outcome was plano in all eyes. Patients were treated bilaterally. One year postoperative outcomes are reported. RESULTS: The mean spherical equivalent refraction (MRSE) for all eyes changed from +2.61 +/- 1.19 D (range: +0.50 to +6.63 D) preoperatively to +0.35 +/- 0.54 D (range: -1.63 to +2.00 D) 1 year postoperatively. Overall, 61% (170/279) of eyes achieved distance uncorrected visual acuity (UCVA) of 20/20 or better, 82% (228/279) of eyes saw 20/25 or better, and 99% (277/279) of eyes saw 20/40 or better. Refractive accuracy was demonstrated as 63.1% (176/279) of eyes achieved a MRSE within +/- 0.50 D and 90.3% (252/279) of eyes within +/- 1.00 D. Less than 2% (4/279) of eyes lost 2 lines of distance best spectacle-corrected visual acuity. Stability of refraction was demonstrated by 6 months, with a mean hyperopic shift of < 0.03 D from 3 to 6 months. CONCLUSIONS: The NIDEK EC-5000 corrected hyperopia and hyperopic astigmatism with UCVA, refractive accuracy, 1-year stability, and safety that surpassed all FDA criteria.  相似文献   

18.
PURPOSE: To analyze the results of hyperopic patients treated with a peripheral presbyLASIK algorithm for the correction of presbyopia. METHODS: The study included 44 eyes of 22 hyperopic patients treated with a peripheral presbyLASIK technique using a Technolas 217z excimer laser. Mean patient age was 56 years (range: 47 to 72 years), mean preoperative spherical equivalent refraction was +1.21 +/- 0.77 diopters (D) (range: +0.50 to +4.00 D), and mean spectacle near addition was +1.76 +/- 0.42 D (range: +1.00 to +2.75 D). The Peripheral Multifocal LASIK (PML) ablation pattern creates a multifocal corneal profile over a 6.5-mm diameter, performing the distance correction first in a 6-mm optical zone and then near correction in a 6.5-mm zone. Main outcome measures were uncorrected visual acuity (UCVA) and best spectacle-corrected visual acuity (BSCVA) for near and distance, spherical equivalent refraction, contrast sensitivity, and corneal aberrations. RESULTS: Six months postoperatively, mean binocular UCVA was 1.06 +/- 0.13 for distance and 0.84 +/- 0.14 for near. Mean postoperative spherical equivalent refraction was -0.42 D (range: -1.12 to +0.87 D). Two (4.5%) eyes lost 1 line of BSCVA for distance and near vision, and 20 (45%) eyes gained 1 line of distance BSCVA. Contrast sensitivity decreased for 3, 6, 12, and 18 cycles/degree. Corneal aberration analysis showed a slight increase in coma and decrease in spherical aberration. CONCLUSIONS: The peripheral presbyLASIK technique used in this study is a safe and efficient treatment that may improve functional near vision in presbyopic patients with low and moderate hyperopia (from +0.50 to +3.00 D).  相似文献   

19.
PURPOSE: To evaluate the results of laser in situ keratomileusis (LASIK) for the correction of low and moderate myopia and astigmatism using the Nidek EC-5000 excimer laser with a modified algorithm. METHODS: Three hundred and ninety-six eyes of 257 patients with myopia ranging from -1.50 to -6.00 D and astigmatism of no more than 4.00 D were included. Manifest spherical equivalent refraction, uncorrected and spectacle-corrected visual acuity were assessed at 1 month (357 eyes, 90%), 3 months (220 eyes, 56%), and 6 months (168 eyes, 42%) after LASIK. RESULTS: Mean preoperative spherical equivalent refraction was -3.60 +/- 1.27 D and mean cylinder was -1.01 +/- 1.08 D. Mean postoperative spherical equivalent refraction was -0.12 +/- 0.31 D and mean cylinder was -0.19 +/- 0.33 D. At 6 months follow-up, 158 eyes (94%) had a mean postoperative spherical equivalent refraction within +/- 0.50 D of emmetropia; 168 eyes (100%) were within +/- 1.00 D. Uncorrected visual acuity was 20/20 or better in 81% (136 eyes) and 20/40 or better in 100%. Two eyes (1.2%) lost 1 line of spectacle-corrected visual acuity due to a decentered ablation. No eye lost 2 or more lines of spectacle-corrected visual acuity. CONCLUSION: Our modified LASIK algorithm with the Nidek EC-5000 excimer laser resulted in safe and predictable outcomes for treatment of low and moderate amounts of myopia and astigmatism.  相似文献   

20.
PURPOSE: To determine the safety, efficacy, predictability, and stability of laser in situ keratomileusis (LASIK) in treating patients with myopic astigmatism using the Meditec MEL 70 G-Scan excimer laser. METHODS: Seventy-four eyes of 42 patients with myopia ranging from -4.50 to -9.88 D and astigmatism ranging from 0.50 to 4.00 D who underwent LASIK with the Meditec MEL 70 G-Scan excimer laser and the Summit Krumeich-Barraquer microkeratome were studied. Patients were followed for 1 year. RESULTS: Mean baseline spherical equivalent refraction was -7.12 +/- 1.70 D and cylinder was 1.62 +/- 1.72 D. At 12 months, mean postoperative spherical equivalent refraction was -0.49 +/- 0.57 D and mean refractive cylinder was 0.59 +/- 0.32 D. Mean change in spherical equivalent refraction between 1 and 12 months after surgery was -0.09 +/- 0.31 D, toward myopia. At baseline, no eyes had best spectacle-corrected visual acuity (BSCVA) of 20/20 or better, and 65% had 20/40 or better. At 12 months after surgery, 10% of eyes had BSCVA of 20/20 or better and 88% of eyes had 20/40 or better. The unusually low postoperative BSCVA results were thought to be due to amblyopia or existence of a higher percentage of some optical aberrations in this group of eyes. Mean uncorrected visual acuity was -1.38 +/- 0.42 LogMAR units (20/400) at baseline and -0.29 +/- 0.25 LogMAR units (20/40) at the 12-month postoperative examination. No eyes lost two or more lines of spectacle-corrected visual acuity. No vision threatening complications were observed. CONCLUSIONS: LASIK with the Meditec MEL 70 G-Scan excimer laser appeared to be safe, effective, reasonably predictable, and stable for correction of myopic astigmatism with a spherical component between -4.25 and -8.25 D and a cylindrical component between 0.50 and 4.00 D. However, astigmatism was slightly undercorrected with the algorithm used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号