首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到8条相似文献,搜索用时 78 毫秒
1.
2.
3.

Background

Tissue-engineered vascular grafts (TEVGs) offer potential to overcome limitations of current approaches for reconstruction in congenital heart disease by providing biodegradable scaffolds on which autologous cells proliferate and provide physiologic functionality. However, current TEVGs do not address the diverse anatomic requirements of individual patients. This study explores the feasibility of creating patient-specific TEVGs by combining 3-dimensional (3D) printing and electrospinning technology.

Methods

An electrospinning mandrel was 3D-printed after computer-aided design based on preoperative imaging of the ovine thoracic inferior vena cava (IVC). TEVG scaffolds were then electrospun around the 3D-printed mandrel. Six patient-specific TEVGs were implanted as cell-free IVC interposition conduits in a sheep model and explanted after 6 months for histologic, biochemical, and biomechanical evaluation.

Results

All sheep survived without complications, and all grafts were patent without aneurysm formation or ectopic calcification. Serial angiography revealed significant decreases in TEVG pressure gradients between 3 and 6 months as the grafts remodeled. At explant, the nanofiber scaffold was nearly completely resorbed and the TEVG showed similar mechanical properties to that of native IVC. Histological analysis demonstrated an organized smooth muscle cell layer, extracellular matrix deposition, and endothelialization. No significant difference in elastin and collagen content between the TEVG and native IVC was identified. There was a significant positive correlation between wall thickness and CD68+ macrophage infiltration into the TEVG.

Conclusions

Creation of patient-specific nanofiber TEVGs by combining electrospinning and 3D printing is a feasible technology as future clinical option. Further preclinical studies involving more complex anatomical shapes are warranted.  相似文献   

4.
5.
6.
7.
8.
ObjectiveEarly Fontan failure is a serious complication after total cavopulmonary connection, characterized by high central venous pressure, low cardiac output, and resistance to medical therapy. This study aimed to estimate postoperative central venous pressure in patients with total cavopulmonary connection using data routinely collected during preoperative assessment. We sought to determine if this metric correlated with measured postoperative central venous pressure and if it was associated with early Fontan failure.MethodsIn this retrospective study, central venous pressure in total cavopulmonary connection was estimated in 131 patients undergoing pre–total cavopulmonary connection assessment by cardiac magnetic resonance imaging and central venous pressure measurement under general anesthesia. Postoperative central venous pressure during the first 24 hours in the intensive care unit was collected from electronic patient records in a subset of patients. Early Fontan failure was defined as death, transplantation, total cavopulmonary connection takedown, or emergency fenestration within the first 30 days.ResultsEstimated central venous pressure in total cavopulmonary connection correlated significantly with central venous pressure during the first 24 hours in the intensive care unit (r = 0.26, P = .03), particularly in patients without a fenestration (r = 0.45, P = .01). Central venous pressure in total cavopulmonary connection was significantly associated with early Fontan failure (odds ratio, 1.1; 95% confidence interval, 1.01-1.21; P = .03). A threshold of central venous pressure in total cavopulmonary connection 33 mm Hg or greater was found to have the highest specificity (90%) and sensitivity (58%) for identifying early Fontan failure (area under receiver operating curve = 0.73; odds ratio, 12.4; 95% confidence interval, 2.5-62.3; P = .002). This association was stronger in patients with single superior vena cava.ConclusionsEstimated central venous pressure in total cavopulmonary connection is an easily calculated metric combining preoperative pressure and flow data. Higher central venous pressure in total cavopulmonary connection is associated with an increased risk of early Fontan failure and is correlated with directly measured post–total cavopulmonary connection pressure. Identification of patients at risk of early Fontan failure has the potential to guide risk-mitigation strategies.  相似文献   