首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Dental materials》2019,35(11):1557-1567
ObjectiveTo evaluate the effect of surface treatments on yttria-tetragonal zirconia polycrystal (Y-TZP) characteristics and on resin-mediated zirconia bond.MethodsY-TZP slabs were grit blasted with 45 μm alumina or with 30 μm silica-coated alumina particles. The chemical treatments were: no-chemical treatment (NC), silane-containing primer (SP), MDP (10-Methacryloyloxydecyl dihydrogen phosphate) and silane-containing primer (MPS), MDP-containing primer (MP) and MDP and silane-containing adhesive (MPA). Contact angle as a function of surface roughness (θm) and surface roughness parameter (Sdr) were measured using Fringe Projection Phase Shifting (FPPS). Surface free energy (γsTOT) was calculated with a goniometer. Chemical interaction between primers/adhesive and zirconia was analyzed using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Resin cement microshear bond strength (μSBS) was analyzed at either 24-h or 8-months water storage (37 °C). θm values, Sdr values, γsTOT and μSBS values were analyzed using Analysis of variance (ANOVA) and post hoc Tukey test (α = 0.05).ResultsChemical treatment had an effect (p < 0.001) on all surface parameters analyzed: θm, γsTOT and Sdr. MP-treated group showed higher incidence of P–O–Zr bonds than the other groups, indicating more chemical linkages. Grit blasting (p < 0.001) and the interaction chemical treatment*storage (p < 0.001) did not affect μSBS; all silane-containing primers showed significant drop in μSBS after aging.SignificanceMDP and/or silane-based solutions affect the physicochemical properties of blasted-zirconia. An MDP-based primer is fundamental to achieve a stable resin-zirconia bonding, but the chemical reactivity of MDP is impaired when this molecule is present in a multicomponent system.  相似文献   

2.
ObjectiveTo evaluate the association between polymorphisms in DLX1, DLX2, MMP13, TIMP1 and TIMP2 genes with dental fluorosis (DF) phenotype.DesignFour hundred and eighty one subjects (108 with DF and 373 DF free) from 6 to 18 years of age were recruited. This population lived in Rio de Janeiro, a city with fluoridation of public water supplies. DF was assessed using the Deańs index modified. Only erupted permanent teeth were assessed. Genetic polymorphisms in DLX1, DLX2, MMP13, TIMP1 and TIMP2 were analyzed by real-time PCR from genomic DNA. Association between DF, genotype, and allele distribution were evaluated using chi-square and logistic regression analyses with an alpha level of 5%.ResultsDF was more prevalent in Afro-descendants than in Caucasians (p = 0.08; OR = 1.83; CI 95% = 1.18–2.82). Logistic regression analysis adjusted by the ethnicity demonstrated a statistical difference for TIMP1 genotype (p = 0.033; OR = 2.93, 95%CI, 1.09–7.90). When only the severer cases of DF were analyzed, polymorphisms in DLX1 and DLX2 were associated with DF (p < 0.05).ConclusionOur results provided evidence that polymorphisms in TIMP1, DLX1 and DLX2 genes may be associated with DF phenotypes.  相似文献   

3.
PurposeThe purpose of this study was to evaluate the effectiveness of both a resin primer containing methyl methacrylate (MMA) and a silanizing agent on bonding to indirect resin composite blocks, using two types of build-up hybrid resin composites.MethodsSHOFU BLOCK HC (Shofu) specimens were blasted with alumina, after which one of two surface treatments was applied: CERA RESIN BOND (Shofu, the Silane group) or HC primer (Shofu, the MMA group). Resin composites made using either Solidex Hardura (SDH, Shofu) or Ceramage Duo (CMD, Shofu) were built up and micro-tensile bond strength (μTBS) values were measured after storage in water for either 24 h or 6 months (n = 24 per group). The fracture surfaces after μTBS measurements and the resin block/build-up resin interfaces were observed by scanning electron microscopy (SEM).ResultsThe bond strength of the Silane/SDH group significantly decreased after 6 months (p < 0.001), whereas in the MMA group there was no significant loss after 24 h or 6 months (p = 0.99). In the CMD group, the bond strength after 6 months was significantly lowered in both the Silane group (p < 0.001) and the MMA group (p < 0.001), but the latter still showed greater adhesion. SEM images demonstrated that the matrix resin was partially destroyed at the fracture surfaces of the MMA group and fracture surface unevenness was observed.ConclusionsA primer containing MMA produced stronger bonding to CAD/CAM resin even after long-term aging compared to a silane treatment.  相似文献   

4.
《Dental materials》2019,35(8):e175-e183
ObjectiveThis study evaluated the influence of experimental composites containing quaternary ammonium monomers (QAM) at different concentrations and alkyl chains on demineralization at enamel-composite margins after cariogenic challenge.MethodsStandardized 4 × 4 mm cavities were cut into 35 bovine enamel blocks, which were randomly divided into seven groups (n = 5) and restored with the following experimental composites and commercial materials: (G12.5) – 5% dimethylaminododecyl methacrylate (DMADDM) with a 12-carbon alkyl chain (G12.10) – 10% DMADDM, (G16.5) – 5% dimethylaminohexadecyl methacrylate (DMAHDM) with a 16-carbon alkyl chain (G16.10) – 10% DMAHDM, (CG) – control group (without QAM), (GZ250) – commercial composite (Filtek Z250®), and (GIC) – glass ionomer cement (Maxxion R®). After restorative procedures, initial microhardness was measured and experimental composites were subjected to Streptococcus mutans biofilm formation for 48 h. After cariogenic challenge, the samples were washed and microhardness was reassessed. A 3D non-contact profilometer was used to determine surface roughness and enamel demineralization was assessed by micro-CT. Microhardness results were analyzed by the Kruskal–Wallis and Mann-Whitney tests and micro-CT results were analyzed by Tukey’s HSD test (95% confidence interval).ResultsNone of the materials could prevent mineral loss at the enamel-restoration margins. The addition of 10% DMAHDM yielded the lowest, albeit statistically significant, mineral loss (p < 0.05). 3D non-contact profilometry showed enamel surface roughness modification after biofilm exposure. The CG had the highest roughness values. Micro-CT analysis revealed mineral loss, except for GIC.SignificanceThe addition of 10% QAM with a 16-carbon chain in experimental composites reduced mineral loss at the enamel-restoration margins after cariogenic challenge.  相似文献   

5.
《Dental materials》2019,35(11):1545-1556
ObjectivesTo evaluate ultrashort-pulse laser (UPL) as a surface treatment for improved bond strength to Yttria-tetragonal zirconia polycrystalline (Y-TZP).MethodsFully-sintered Y-TZP samples received either no treatment (CTL), or were treated by alumina blasting (ALB), tribochemical silica coating (SIL), or one of two UPL patterns: multiple pulses laser surface dots with 2.5 μm spacing (8 mJ, 10 kHz)(LSD); or single pulse laser surface lines with 2.5 μm spacing (4 mJ, 6.7 kHz)(LSL). Surface roughness, wettability (contact angle), and quantification of crystalline phases were evaluated for each group (n = 3/group). Y-TZP treated slabs were cemented to resin composite slabs using silane and 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing adhesive. Beams from the Y-TZP/resin blocks were microtensile tested (n = 5/group) after 48 h water incubation (37 °C) with or without subsequent thermocycling (5–55 °C, 5000 cycles).ResultsAll surface treatments increased surface roughness values versus control (P < 0.001). Contact angles were lowest for SIL (6.57 ± 2.37°) and highest for control (50.97 ± 6.30°). LSL and LSD were the only treatments that did not increase the relative monoclinic phase. All surface treatments significantly increased microtensile bond strengths (μTBS) compared with the control group (P < 0.001), with highest values for UPL (LSD: 35.40 ± 4.53 MPa > LSL: 31.84 ± 8.46 MPa > SIL: 19.95 ± 3.99 MPa = ALB: 19.51 ± 2.55 MPa > CTL: 14.51 ± 2.23 MPa). Thermocycling significantly reduced bond strength for all treatments in a surface treatment-dependent manner.SignificanceThe ability of UPL to alter Y-TZP surface morphology, increase wettability and μTBS without increasing the monoclinic content suggests its potential to improve bonding to the underlying resin cement and tooth without compromising the strength of the restoration.  相似文献   

6.
ObjectivesInformation regarding the effects of orthodontic bracket debonding on zirconia restorations, and the preferred method for residual adhesive removal from the zirconia restoration surface is lacking. Thus, this study aimed to assess the effects of different methods of residual adhesive removal after orthodontic bracket debonding on flexural strength, surface roughness, and phase transformation of high-translucent (HT) zirconia.Materials and methodsThis in vitro study evaluated 72 bar-shaped HT zirconia specimens; 18 specimens were assigned to the control group. Metal brackets were bonded to the remaining specimens by resin cement. After bracket debonding, the residual adhesive on the surface of specimens was removed by three methods (n = 18): a 30-flute tungsten-carbide (TC) bur at low speed, an ultrafine diamond bur at high speed, and Er:YAG laser irradiation. The surface roughness (Ra and Rz) was measured. X-ray diffraction (XRD) analysis was carried out, and the flexural strength was measured as well. Data were statistically analyzed (α = 0.05).ResultsBefore polishing, all methods increased the Ra and Rz values (P < 0.05) except for the diamond bur yielding a Rz value comparable to that of the control group. The Ra values of the test groups were comparable after polishing, and still higher than that of the control group (P < 0.05). The flexural strength of all three test groups was comparable (P > 0.05), and significantly lower than that of the control group (P < 0.001). The monoclinic phase was not observed in any group.ConclusionsOrthodontic bracket debonding adversely affects the surface roughness and flexural strength of zirconia despite polishing.  相似文献   

7.
PurposeThis study aims to evaluate the effect of different glazing methods on translucency parameter (TP), contrast ratio (CR), opalescence parameter (OP), surface roughness (Ra) and topography of the silicate ceramics.MethodsSeventy specimens (10 × 10 × 1 mm) were fabricated from lithium disilicate (IPS e.max CAD, abbreviated as E) and zirconia-reinforced lithium silicate (Vita Suprinity, abbreviated as VS) ceramics and divided into 7 subgroups (n = 10) according to the polishing and glazing procedures: (1) mechanical polishing before-crystallization (m-BC), (2) mechanical polishing after-crystallization (m-AC), (3) glaze powder/liquid after-crystallization (pl-AC), (4) glaze-paste before-crystallization (gp-BC), (5) glaze-paste after-crystallization (gp-AC), (6) glaze-spray before-crystallization (gs-BC), (7) glaze-spray after-crystallization (gs-AC). Color and Ra measurements were performed. CIEL*a*b* and CIEXYZ parameters were recorded and TP, CR, and OP values were calculated. Data were analyzed using two-way ANOVA and Tukey HSD tests (α = 0.05).ResultsIn E groups, the highest Ra value was found in gs-AC (1.66 ± 0.14 μm) while the lowest value was found in pl-AC (0.68 ± 0.08 μm). In VS groups, the highest Ra value was found in gp-BC (1.64 ± 0.25 μm) while the lowest value was found in m-AC (0.77 ± 0.06 μm) (p < 0.05). The mean TP value of E (17.62 ± 0.73) was found to be higher than VS (15.37 ± 1.16). The CR (0.72±0.030) and OP (12.06 ± 0.74) values of VS were found higher than CR (0.57 ± 0.02) and OP (6.72 ± 0.40) values of E.ConclusionsZirconia-reinforced silicate ceramics have higher opalescence and lower translucency values than lithium disilicate ceramics. Increase in surface roughness reduces translucency. Glaze powder/liquid after-crystallization is the most effective way to reduce surface roughness of lithium disilicate ceramics while that is mechanical polishing after-crystallization for zirconia-reinforced silicate ceramics.  相似文献   

8.
《Dental materials》2019,35(12):1769-1775
ObjectiveTo compare shear bond strength (SBS) and interfacial fracture toughness (IKIC) results when assessing the effect of surface roughness and thermocycling on the adherence of a resin composite luting agent (RCLA) to a CAD/CAM resin composite block (RCB).MethodsTetric CAD HT along with the recommended bonding system, Adhese Universal and Variolink Esthetic LC, were used. Surface roughness was achieved with 600/320/60 grit SiC papers. Samples were stored 24 h in 37 °C water or thermocycled 10000× (5 °C–55 °C) prior to testing. Results were analyzed by univariate ANOVA and Scheffé modified t-tests (α = 0.05). Fractured specimens were viewed with a stereo microscope and selected specimens with a scanning electron microscope.ResultsSBS results showed a significant difference between the 60 grit group and the other groups, both after 24 h and thermocycling. A large number of SBS samples showed cohesive fracture or subsurface damage in RCB. Thermocycling led to a significant decrease in SBS in all groups. IKIC results showed no significant differences due to surface preparation after 24 h storage in 37 °C. After thermocycling, there was a significant difference between the 60 and the 600 grit groups. All KIC samples fractured adhesively at the RCB surface. KIC of the RCLA was significantly higher than IKIC of all groups.SignificanceThe results endorse the use of fracture mechanics methodology for the assessment and characterization of adherence, while identifying difficulties in its implementation. The results suggest also that adherence to CAD/CAM RCB may be limited by the strength of the resin composite block — adhesive interface.  相似文献   

9.
ObjectivesThe aim of this laboratory study was to evaluate the wear resistance of crowns made from current computer-aided design and computer-aided manufacture (CAD/CAM) materials. In addition, the abrasion of the steatite antagonist against these materials was compared.MethodsIdentically shaped crowns of lithium disilicate, zirconia-reinforced lithium disilicate and a polymer-infiltrated ceramic network (PICN) were fabricated with an occlusal thickness of 1.5 mm and a lateral wall thickness of 1.2 mm (n = 8). The crowns were cemented with a dual-polymerizing luting resin on composite resin dies. Using spherical steatite antagonists, all specimens were loaded with 49 N for 1,200,000 cycles in a mastication simulator with additional thermocycling. After 120,000, 240,000, 480,000, 960,000, and 1,200,000 cycles, precision impressions were made and investigated with a laser scanning microscope. The vertical and volume substance loss was measured. Additionally, the substance loss of the antagonists was evaluated after 1,200,000 loading cycles.ResultsNo significant difference (p > 0.05) was found in the median volume loss of the test materials after 1,200,000 cycles (lithium disilicate: 0.405 mm3, PICN: 0.362 mm3, zirconia-reinforced lithium disilicate: 0.340 mm3). The vertical substance loss of PICN (157 μm) was significantly lower (p  0.05) than that of lithium disilicate (201 μm) and zirconia reinforced lithium disilicate (191 μm). However, the substance loss of steatite against zirconia-reinforced lithium disilicate (0.191 mm3) was significantly lower (p  0.05) than against lithium disilicate (0.296 mm3) and PICN (0.531 mm3).SignificanceAll three CAD/CAM materials showed wear resistance that seems appropriate for clinical application. Also, the abrasion of the antagonist looks promising.  相似文献   

10.
PurposeCandida-associated denture stomatitis is the most prevalent form of oral candidosis affecting 65% of denture wearers. Failure of therapy and recurrence of infection are not uncommon and the continuous use of antifungal agents may affect the surface properties of the denture material and may contribute to Candida adhesion. This study aimed to investigate surface properties of poly(methyl methacrylate) PMMA denture material before and after exposure to antifungal agents and its relation to in vitro adhesion of Candida albicans.MethodsFour groups of acrylic specimens (20 mm × 20 mm × 2.5 mm) were prepared (25 specimens in each group). Specimens were immersed in nystatin (group 1), fluconazole (group 2), distilled water (group 3) and group 4 was not exposed. Specimens were tested for surface roughness, contact angle, surface hardness and in vitro Candida adherence to PMMA.ResultsThe results showed that nystatin had no statistically significant effect on surface hardness (P > 0.05), but had a statistically significant effect on surface roughness, contact angle, and Candida adhesion to PMMA (P < 0.05). On the other hand, fluconazole had no statistically significant effect on surface hardness or roughness (P > 0.05), but had a statistically significant effect on contact angle, and Candida adhesion to PMMA (P < 0.05). Distilled water had no statistically significant effect on surface hardness, roughness, contact angle, or Candida adhesion to PMMA (P > 0.05).ConclusionsExposure of PMMA to nystatin may induce changes in roughness, wettability while exposure to fluconazole may affect surface free energy and therefore may increase Candida adhesion to it.  相似文献   

11.
《Archives of oral biology》2014,59(12):1328-1333
ObjectiveThis in vitro study aimed to examine the etching effect of acidic fluoride solutions on enamel.Materials and methods24 human teeth divided into 48 enamel-specimens were partly isolated with impression material. Specimens were exposed for 10 min to 20 ml of the following solutions: 1.6% TiF4, 3.9% SnF2, 0.2% HF and 1.8% citric acid (CA). The isolation was removed and 24 specimens analysed by profilometry (Δheight: exposed/isolated enamel surfaces, surface roughness parameters). For the remaining 24 specimens [Ca2+] in the test solutions was analysed by atomic absorption spectroscopy.ResultsMedian Δheights (μm) after exposure were: TiF4 0.07, SnF2 −0.03, HF −0.14 and CA −5.92. TiF4-exposed surfaces showed both deposits and etched areas and exhibited statistically significant different surface roughness parameters compared to the HF- and SnF2-exposed surfaces. Median [Ca2+] values (ppm): TiF4 1.88, SnF2 0.11, HF 0.10 and CA 2.17.ConclusionAt the [F] tested in this study it can be concluded that SnF2- and HF solutions had negligible erosive effects on enamel. TiF4 solution resulted in an incomplete surface deposition associated with calcium dissolution suggesting that TiF4 applied as solution may not be advisable.  相似文献   

12.
《Dental materials》2022,38(3):e59-e67
ObjectiveTo assess the effects of a resin cement in high and low viscosity and distinct conditioning of the intaglio surface of lithium disilicate glass-ceramic crowns on fatigue performance of the crowns.MethodsProsthetic preparations (full-crown) in resin epoxy and crowns in lithium disilicate glass-ceramic were machined and allocated considering 2 factors (n = 10): “surface treatment” (HF – 5% hydrofluoric acid etching, followed by silane application; or E&P–self-etching ceramic primer) and “resin cement” (high or low viscosity). The preparations were etched with 10% hydrofluoric acid and an adhesive was applied. The intaglio surfaces of the ceramic crowns were treated as aforementioned (HF or E&P) and luted with high or low viscosity. The bonded sets were subjected to fatigue testing (step-stress approach: initial load of 200 N, step-size of 50 N, 10,000 cycles/step, 20 Hz) and complementary analyses (fractographic, topographic, and cross-sectional bonded interfacial zone analyses) were performed.ResultsTreatment with HF and silane with high viscosity resin cement (955 N/156,000 cycles) and E&P with low viscosity resin cement (1090 N/183,000 cycles) showed the best fatigue performance (statistical similarity between them). The failures originated from defects of the cement-ceramic interface, and the HF treatment induced a more pronounced topographical alteration.SignificanceDistinct topographical patterns from the HF and E&P treatments induced better fatigue results for the specific viscosity of the resin cement. Therefore, the fatigue performance depended on the existing topography, type of intaglio surface’s defects/irregularities after surface treatment, and how the luting agent filled the irregularities.  相似文献   

13.
《Dental materials》2014,30(12):e330-e336
ObjectiveTo evaluate the effect of hydrofluoric acid (HFA) etching time and resin cement bond on the flexural strength of IPS e.max® Press glass ceramic.MethodsTwo hundred and ten bars, 25 mm × 3 mm × 2 mm, were made from IPS e.max® Press ingots through lost-wax, hot-pressed ceramic fabrication technology and randomly divided into five groups with forty-two per group after polishing. The ceramic surfaces of different groups were etched by 9.5% hydrofluoric acid gel for 0, 20, 40, 60 and 120 s respectively. Two specimens of each group were selected randomly to examine the surface roughness and 3-dimensional topography with atomic force microscope (AFM), and microstructure was analyzed by the field emission scanning electron microscope (FE-SEM). Then each group were subdivided into two subgroups (n = 20). One subgroup of this material was selected to receive a thin (approximately 0.1 mm) layer of resin luting agent (Variolink N) whereas the other subgroup remained unaltered. Half of subgroup's specimens were thermocycled 10,000 times before a 3-point bending test in order to determine the flexural strength. Interface between resin cement and ceramic was examined with field emission scanning electronic microscope.ResultsRoughness values increased with increasing etching time. The mean flexural strength values of group 0 s, 20 s, 40 s, 60 s and 120 s were 384 ± 33, 347 ± 43, 330 ± 53, 327 ± 67 and 317 ± 41 MPa respectively. Increasing HF etching times reduced the mean flexural strength (p < 0.05). However, the mean flexural strength of each group, except group 0 s, increased significantly to 420 ± 31, 435 ± 50, 400 ± 39 and 412 ± 58 MPa after the application of dual-curing resin cement. In the present investigation, no significant differences after thermocycling on the flexural strengths were evident.SignificanceOvertime HF etching could have a wakening effect on IPS e.max® Press glass ceramic, but resin cement bonding to appropriately etched surface would strengthen the dental ceramic.  相似文献   

14.
ObjectivesThe purpose of this study was to investigate the effect of different surface treatments on the bond strength (σ) of repaired, aged resin composites (ARC).MethodsForty blocks of Filtek Z250? (Z2) and Filtek Supreme? (SU) were made, stored in deionized water for 9 days, and randomly assigned to different surface treatment groups: hydrofluoric acid etching (HA), abrasion using a coarse diamond bur (AB), sandblasting with alumina particles (AO), and silica coating (SC). The average roughness (Ra) of the treated surfaces was measured with a profilometer. An adhesive system (SB-Adper Single Bond Plus?), a silane (SI) or a combination of both (SI + SB) were applied after each surface treatment. The blocks were restored with the same composite (RC) and cut to produce bars that were turned into dumbbell-shaped specimens (0.5 mm2) using a precision grinding machine. The specimens (n = 30) were tested in tension to fracture and the microtensile bond strength (σ) values were calculated (MPa). Data were analyzed using three-way ANOVA/Tukey test (α = 0.05) and Weibull statistics.ResultsAO and SC produced similar Ra values, which were greater than the value produced by HA. The σ values were statistically influenced by the type of RC (p < 0.0001), by the surface treatment (p < 0.0001) and by the surface coating (p < 0.0001). Treating the surface of Z2 with SC + SB produced the greatest m value.SignificanceAO and SC produced the greatest σ values, irrespective of the primer (SI, SB or SI + SB) used. Yet, the RC microstructure influenced the mean σ values, which were greater for Z2 than for SU. The HA should not be used for repairing ARC.  相似文献   

15.
《Dental materials》2020,36(7):905-913
ObjectivesDifferent approaches are currently undertaken to structure the endosseous part of zirconia implants. The purpose of the present study was to evaluate how surface roughness and monoclinic to tetragonal phase ratio of zirconia affect cell behavior of human osteoblasts.MethodsZirconia discs with five different surface structures were produced: machined; machined heat-treated; polished; polished heat-treated; sandblasted, etched and heat-treated (cer.face 14, vitaclinical). The specimen surfaces were then characterized in terms of monoclinic to tetragonal phase ratio, wettability, roughness and visualized using scanning electron microscopy. To determine the reaction of the human osteoblastic cells (MG-63) to the surface roughness and monoclinic to tetragonal phase ratio of zirconia, cell spreading, morphology, actin cytoskeleton, viability and gene expression of alkaline phosphatase (ALP), collagen type I (COL) and osteocalcin (OCN) were assessed.ResultsHeat-treatment of the specimens significantly improved the surface wettability. With increased surface roughness Ra of the specimens, cell spreading was reduced. Cell viability after 24 h correlated linearly with the tetragonal phase ratio of the specimens. Gene expression after 24 h and 3 d was comparable on all specimens irrespective their surface roughness or monoclinic to tetragonal phase ratio.SignificanceSmooth zirconia surfaces with a high tetragonal phase ratio revealed best surface conditions for MG-63 osteoblastic cells and may be considered to design the endosseous part of zirconia implants.  相似文献   

16.
ObjectivesThe purpose of this study was to evaluate the effect of the amount of 3-methacryloxypropyl-trimethoxysilane (γ-MPS) coupling agent on some physical–mechanical properties of an experimental resin composite for understanding the optimum amount of silanization.MethodsSilica nanoparticles (Aerosil OX 50) used as filler were silanized with 5 different amounts of γ-MPS 1.0, 2.5, 5.0, 7.5 and 10 wt% relative to silica. The silanizated silica nanoparticles were identified by FT-IR spectroscopy and thermogravimetric analysis (TGA). Then the silanized nanoparticles (60 wt%) were mixed with a Bis-GMA/TEGDMA (50/50 wt/wt) matrix. Degree of conversion of light cured composites was determined by FT-IR analysis. The static flexural strength and flexural modulus were measured using a three-point bending set up. The dynamic thermomechanical properties were determined by DMA analyzer. Sorption, solubility and volumetric change were determined after storage of composites in water or ethanol/water solution. Thermogravimetric analysis was performed in air and in nitrogen atmosphere from 50 to 800 °C.ResultsAt lower silane amounts used (1.0, 2.5 wt%) the silane molecules must have a parallel orientation relative to the silica surface. At higher silane amounts (>2.5 wt%) silane molecules form a layer around the filler particles which now have to occupy a random, parallel and perpendicularly orientation relative to the silica surface. No significant statistic difference was found to exist between the flexural strength and flexural modulus values of composites with different silane contents. Dynamic elastic modulus E′ showed a maximum value for the composite contained 5 wt% silane. The composites with the higher amounts of silane showed the lower values for the tan δ at the Tg revealing that these composites have better interfacial adhesion between filler and matrix.SignificanceThe amount of silane used for the silanization of silica particles affect the orientation of the silane molecules relative to the silica surface. This seems to affect the dynamic mechanical properties of composites.  相似文献   

17.
《Dental materials》2020,36(6):808-815
ObjectivesThe present investigation evaluated the step stress accelerated test (SSALT) load profiles on the survival probability of a glass ceramic under two surface conditions (polished or roughened).MethodsSuprinity–ZLS blocks (Vita Zhanfabrik) were shaped into cylinders, cut in a sawing machine, and crystalized according to the manufacturer's instructions. 60 discs were obtained (Ø = 12 mm, thickness = 1.2 mm) and randomly assigned into two surface conditions: “p” polished surface (400–1200-grit SiC papers), and “r” roughened surface (200-grit SiC papers). Profilometry was performed in all discs to evaluate average surface roughness prior to flexural fatigue strength testing. 3 discs of each group were submitted to biaxial flexural strength in an universal testing machine (0.5 mm/min) and the mean load to failure (N) was calculated to determine SSALT profiles. 27 specimens per surface condition were assigned into three profiles – Mild (n = 9), Moderate (n = 9), and Aggressive (n = 9), and submitted to the fatigue test (60–320 N, 140,000 cycles at 1.4 Hz). The results were analyzed using the Kaplan-Meier and Wilcoxon tests (5%), 2-way ANOVA and Tukey test (α = 5%).ResultsKaplan-Meier and generalized Wilcoxon showed (P = 0.002) that polished groups showed higher survival probability than roughened condition (P < 0.05). A rough internal surface impacted deleteriously on the fatigue strength and reliability of ZLS ceramic. Both surface conditions were more sensitive to the aggressive profile than the other profiles, even worst for the roughened group. Regardless the load profile, 0% survival probability was observed at 384 MPa for polished condition. While for roughened, aggressive tested specimens did not survived 147 MPa followed by moderate at 312 MPa and mild at 384 MPa. The failure modes showed fracture marks originating from superficial grooves for both surface conditions.SignificancePolished specimens are sensitive to the load profile variation, confirming the effect of surface morphology on the fatigue results.  相似文献   

18.
《Dental materials》2020,36(4):e126-e139
ObjectiveTo investigate the effect of different surface finishing and polishing regimes and low temperature degradation on flexural strength, phase transformation and surface topography of ultra-translucent ZrO2 ceramic.Methods300 (n = 15/group) of conventional zirconia (Z: Ice Zirkon Transluzent) and ultra-translucent zirconia (UT: Prettau Anterior) bar-specimens were made and divided according to the "Finishing/Polishing" - (C — Control, B — diamond rubber polishers, P — adjusting with burs, PB — adjusting with burs + diamond polishers, PG — adjusting with burs + glaze), "Low temperature Degradation (LTD)" (with or without a treatment at 127 °C, 1.7 bar/24 h). Then, a 3-point mini flexural test was performed in a universal testing machine (1 mm/min, 500 kgf load cell). SEM, EDS, XDR, AFM, optical profilometry and Weibull analysis were performed. Data were analyzed by 3-way ANOVA and Tukey’s post-test (5%).ResultsGroups ZPBD (1670 ± 253 MPa), ZBD (1664 ± 217 MPa), and ZB (1655 ± 3678 MPa) showed significantly higher flexural strength than the UTPG group (372 ± 56 MPa). The Weibull modulus was significantly higher for the ZPD group compared to the UB, UCD, UPD and UPBD, while UTB, UTCD and UTPD had the lowest value. Monoclinic phases were observed only in the conventional zirconia groups and were more evident after LTD. Diamond rubber polishers presented less roughness for both zirconias.SignificanceThe use of diamond rubber polishers is the most suitable finishing/polishing method for zirconia ceramic restorations and that final glazing reduces the fracture resistance of these materials.  相似文献   

19.
PurposeThis finite element analysis (FEA) compared stress distribution on external surface of different morse taper implants, varying implant bodies length and dimensions of metal-ceramic crowns in order to maintain the occlusal alignment.MethodsThree-dimensional finite element (FE) models were designed representing a posterior left side segment of the mandible: group 0, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13 mm and 11 mm implants (regular) and 0.8 mm for 5 mm implants (short). Evaluation was performed on a computer program (Ansys software), with oblique loads of 365 N for molars and 200 N for premolars, applied on ridges of cusps and grooves.ResultsAbutments with 0.8 mm height generated less von Mises stresses compared with 3.5 mm height. The use of short implants associated with bigger crowns concentrated higher stress distribution and stress values on the surface implants, principally on the vestibular side (oblique direction of the loads). The more distal implant concentrated higher stress.ConclusionsMoreover, these 5 mm implants were positioned at the cortical bone level, which has higher elastic modulus and may have influenced at the stress distribution. However, despite the higher stresses, these implants were well able to withstand the applied forces.  相似文献   

20.
ObjectivesTo evaluate the effect of surface conditioning on the microtensile bond strength of zirconium-oxide ceramic to dual-cured resin cements.MethodsEighteen cylinder-shaped zirconium-oxide ceramic blocks (Cercon® Zirconia, Dentsply) were treated as follows: (1) Sandblasting with 125 μm aluminum-oxide (Al2O3) particles; (2) tribochemical silica coating using 50 μm Al2O3 particles modified by silica; (3) no treatment. Each ceramic cylinder was duplicated in composite resin (Tetric Evo Ceram, Ivoclar-Vivadent) using a silicon mold. Composite cylinders were bonded to conditioned ceramics using: (1) Calibra (Densply Caulk); (2) Clearfil Esthetic Cement (Kuraray); (3) Rely × Unicem (3 M ESPE). After 24 h bonded specimens were cut into microtensile sticks that were loaded in tension until failure. Data were analyzed using two-way ANOVA and Student–Newman–Keuls test for multiple comparisons (p < 0.05). Failure mode was recorded and the interfacial morphology of debonded specimens was observed using a scanning electron microscope (SEM). Surface topography and ceramic average surface roughness were analyzed under an atomic force microscope (AFM).ResultsSignificant changes in zirconia surface roughness occurred after sandblasting (p < 0.001). Bond strength of Clearfil cement to zirconia was significantly higher than that of Rely × Unicem and Calibra, regardless of the surface treatment (p < 0.001). When using Calibra, premature failures occurred in non-treated and silica coated zirconia surfaces.SignificanceThe phosphate monomer-containing luting system (Clearfil Esthetic Cement) is recommended to bond zirconia ceramics and surface treatments are not necessary.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号