 共查询到17条相似文献,搜索用时 517 毫秒
1.
目的探讨同源动态能谱CT和MSCT在脊柱扫描中的差异。方法将脊柱疾病患者50例随机分为A、B组两组,每组25例。A组采用同源双电压(80、140kVp)动态扫描,FBP重建单能量图像,记录图像噪声-能级曲线、椎体CNR随能量变化曲线,得出最低图像噪声值及最高CNR值的最佳能级,测量图像噪声及椎体CNR。B组常规MSCT扫描,FBP图像重建。比较两组辐射剂量、图像噪声和椎体CNR。结果 A组最佳能级为70keV,图像噪声为(16.12±1.48)HU,较B组(53.95±4.97)HU明显降低(t=3.25,P<0.05);CNR为5.89±0.46,是B组(1.67±0.15)的3.5倍(t=5.43,P<0.05);容积CT剂量指数为(7.64±0.71)mGy,较B组的(16.34±1.24)mGy降低了53%(t=15.62,P<0.05)。结论同源动态能谱CT脊柱成像较常规MSCT可明显降低辐射剂量,降低图像噪声,提高椎体CNR,改善图像质量。  相似文献   

2.
目的比较冠状动脉CT血管造影(coronary CT angiography,CCTA)应用前瞻性心电门控扫描+滤波反投影算法(filter back projection,FBP)、纯化单能谱最佳单能量+FBP法、纯化单能谱最佳单能量+迭代重建(sinogram affirmed iterative reconstruction,SAFIRE)的图像质量差异,探讨冠状动脉双源CCTA成像的优化方案。方法拟诊或冠心病复诊、行冠状动脉双源CT血管造影超体质量患者80例,随机分为对照组和观察组各40例,对照组采用前瞻性心电门控触发序列扫描,采用FBP法重建;观察组采用双能量模式扫描,将自动获得的100、140kVp数据导入Heart PBV软件,经Mononergetic程序处理获得65、70、75、80、85、90keV单能量图像,进行FBP法重建,比较不同单能量重建图像主动脉根部(左冠状动脉开口处)CT值、噪声(noise determination,SD)、信噪比(signal noise ratio,SNR)、对比噪声比(contrast noise ratio,CNR)后选择最佳单能量,然后对最佳单能量数据行SAFIRE法重建。比较对照组心电门控扫描+FBP重建和观察组最佳单能量+SAFIRE重建、最佳单能量+FBP重建的主动脉根部CT值、SD、SNR、CNR、图像质量评分。结果观察组有效辐射剂量[(3.31±0.43)mSv]与对照组[(3.52±0.59)mSv]比较差异无统计学意义(P0.05);观察组在75keV单能量时主动脉CT值[(438.21±38.34)Hu]较高,SNR、CNR*(23.52±3.23、0.99±0.01)最高,SD[(18.65±3.81)Hu]较低,为最佳纯化单能谱图像keV水平;观察组采用最佳单能量+SAFIRE重建时,SNR(32.61±2.11)、CNR(39.24±2.34)高于对照组心电门控+FBP重建(17.61±3.22、22.13±3.62)和观察组最佳单能量+FBP重建(23.52±3.23、28.32±2.51),SD[(13.45±3.68)Hu]低于对照组心电门控+FBP重建[(22.63±5.18)Hu]和观察组最佳单能量+FBP重建[(18.65±3.81)Hu](P0.05),主动脉CT值[(437.34±38.21)Hu]、图像质量评分[(4.84±0.05)分]高于对照组心电门控+FBP重建[(398.76±46.62)Hu,(4.66±0.15)分](P0.05),且图像质量评分高于观察组最佳单能量+FBP重建[(4.78±0.06)分](P0.05)。结论 CCTA采用纯化75keV单能谱单能量+SAFIRE重建可获得最佳图像质量。  相似文献   

3.
目的评价冠状动脉CT成像(CCTA)中不同级别iDose~4迭代重建技术的图像质量、噪声差异,探讨具有最佳图像质量及低噪声的iDose~4级别。方法应用Philips,Ingenuity Core 128CT对60例患者行回顾性心电门控CCTA,采集的原始数据分别进行传统滤过反投影法(FBP)和iDose~4-1~iDose~4-7的图像重建。由2名影像诊断学医师采用4分法双盲评价冠状动脉的9个主要分支;记录噪声值、SNR值及CNR值,对数据进行统计学分析,比较8组数据的差异。结果不同级别的iDose~4图像SNR值和CNR值均明显高于FBP,噪声值较FBP低,且iDose~4的SNR值和CNR值随级别升高而逐渐升高。iDose~4-3、iDose~4-4的图像质量评分值无统计学差异,但iDose~4-4的SNR值、CNR值均优于iDose~4-3,且噪声值相对较低,故认为iDose~4-4为最佳成像级别。结论在相同辐射剂量条件下冠状动脉CT成像,与FBP比较,采用iDose~4可明显提高图像质量,降低噪声;本组条件下,iDose~4-4可以获得最佳图像质量及低噪声。  相似文献   

4.
目的探讨能谱CT单能量成像联合自适应统计迭代重建(ASi R)技术在兔正常肝脏增强扫描中的应用价值。方法健康新西兰大白兔12只,每只兔子使用CT能谱成像(GSI)扫描模式行腹部双期增强扫描,在9个单能量水平(40、50、60、65、70、75、80、90、110 ke V)使用不同比例ASi R混合算法(10%~100%,间隔10%)和滤波反投影(FBP)算法重建图像,得到A组和B组图像。24 h后对每只兔子行100 k V管电压常规腹部双期增强扫描,亦使用不同比例ASi R混合算法(10%~100%,间隔10%)和FBP算法重建图像,得到C组和D组图像。由两名放射学家对4组门静脉期图像质量采用5分评分制法进行主观评分,采用秩和检验比较,观察者间一致性采用Kappa检验。测量4组门静脉期图像的噪声、肝脏信噪比(SNR)和对比噪声比(CNR),并测量最佳CNR单能量水平,结果采用单因素方差分析及配对t检验比较。结果 GSI扫描组有效辐射剂量(2.76±0.23)m Sv低于100 k V常规扫描组(3.21±0.28)m Sv(t=2.787,P=0.018)。A组图像中65~75 ke V单能量联合40%ASi R时图像质量最好,主观评分最高;B组图像中65~75 ke V单能量水平时图像质量最好;C组图像中联合40%ASi R时图像质量最好;4组图像主观评分差异有统计学意义,A组图像高于B、C、D三组图像(P<0.05)。总体上,随着单能量水平的升高及ASi R比例的增加,图像噪声逐渐降低,在110 ke V联合100%ASi R时图像噪声最低[(3.17±0.81)HU];70 ke V联合40%ASi R时图像噪声[(6.41±0.67)HU]低于70 ke V联合FBP[(8.09±0.87)HU]、100 k V联合40%Asi R[(9.56±0.79)HU]和100 k V联合FBP[(12.07±1.07)HU](均P<0.05)。肝脏SNR在9个单能量水平中于70 ke V最高;联合ASi R重建时,随着ASi R比例的增加,SNR逐渐升高,在70 ke V联合100%ASi R时图像SNR最高(14.48±0.56);70 ke V联合40%ASi R时肝脏SNR(13.78±0.58)高于70 ke V联合FBP(11.82±0.73)、100 k V联合40%ASi R(9.23±0.54)和100 k V联合FBP(8.11±0.86)(所有P<0.05)。肝脏CNR随着ASi R比例的增加,呈逐渐增高趋势;最佳CNR单能量水平位于40~43 ke V(58.33%)和68~72 ke V(41.67%);70 ke V联合40%ASi R时肝脏CNR(4.84±0.17)高于70 ke V联合FBP(4.11±0.21)、100 k V联合40%ASi R(3.85±0.18)和100 k V联合FBP(3.17±0.25)(均P<0.05)。结论在兔正常肝脏模型腹部增强扫描中,能谱CT单能量成像(65~75 ke V)联合40%ASi R重建算法可以降低辐射剂量,且图像质量优于单能量成像联合FBP重建、100 k V常规扫描联合ASi R重建和100 k V常规扫描联合FBP重建。  相似文献   

5.
目的 与传统滤波反投影(FBP)重建比较,评价Flash双源CT基于原始数据的正弦图确定迭代重建(SAFIRE)在冠状动脉支架中的应用价值。 方法 对54例患者冠状动脉支架术后行DSCT冠状动脉成像,比较FBP、SAFIRE(1~5)重建6组图像的平均CT值、SNR、支架内CT值净增比(SAIR)、图像质量主观评分、支架显示情况等。 结果 主动脉根部、支架内、支架上方冠状动脉的平均CT值差异均无统计学意义(P均>0.05)。SAIR、SNR差异有统计学意义(P均<0.05),FBP重建SAIR值最大,SAFIRE 3重建SAIR值最小;SAFIRE 3的SNR值最大。FBP与SAFIRE重建图像质量主观评分差异有统计学意义(P<0.05),SAFIRE 3主观评分最高[(3.24±0.57)分]。FBP与SAFIRE重建对于病灶的显示情况基本一致。 结论 与传统的FBP重建比较,SAFIRE重建可明显降低冠状动脉支架图像噪声,改善图像质量,更清晰显示支架内斑块。SAFIRE强度采用机器默认的重建强度3图像质量最佳。  相似文献   

6.
目的:评价低管电压结合自适应统计性迭代算法对腹部CT平扫图像的影响.方法:77例BMI<22 kg/m2的腹部CT平扫患者采用管电压80 kVp、自动管电流(噪声指数14)、50%ASIR重建,为实验组;56例BMI<22 kg/m2的腹部平扫CT患者采用管电压120 kVp、自动管电流(噪声指数10)、FBP重建,为对照组.测量两组图像肝脏和脾脏的噪声、信噪比(SNR)、对比噪声比(CNR)并记录CT剂量指数,两名高年资诊断医师采用盲法对两组的图像质量进行客观测量和主观评价.利用独立样本t检验对两组结果进行比较,两名医师的一致性评估采用Kappa检验.结果:实验组肝脏和脾脏的噪声分别为(14.99±1.95)HU、(14.62±2.17)HU,SNR分别为3.76±0.65、4.07±0.71,CNR分别为2.37±0.61、7.32±0.55,CT剂量指数(CTDIw)为(6.89±0.39)mGy,图像质量主观评分为4.50±0.51;对照组肝脏和脾脏的噪声分别为(27.1±6.42)HU、(27.11±6.4)HU,SNR分别为2.39±0.99、2.14±0.69,CNR分别为3.07±0.50、6.19±0.39,CTDIVOL为(ll.03±6.44)mGy,图像质量主观评分为4.21±0.46.独立样本t检验中肝脏和脾脏的CNR差异没有统计学意义(t值为0.67、1.61,P值为0.51、0.11);两组图像肝脏噪声、脾脏的噪声、肝脏的SNR、脾脏的SNR、CT剂量指数、图像质量主观评分差异均具有统计学意义(t值分别为11.68、11.18、9.52、12.57、10.02、3.51,P值均<0.05).结论:在腹部CT平扫中针对BMI<22 kg/m2的患者采用低管电压结合自适应统计性迭代算法,不但可以降低辐射剂量,而且还可提高图像质量.  相似文献   

7.
目的探讨自适应统计迭代重建(ASIR)技术对青年患者骶髂关节CT图像噪声和质量的影响。方法应用宝石能谱CT(Discovery CT 750HD)对30例青年患者行骶髂关节CT螺旋扫描。分别采用传统滤过反投影法(FBP组)和ASIR算法对原始投影数据进行重建,后者以10%为间隔在10%~100%间重建10组图像(ASIR组)。比较不同重建图像在同一层面的图像标准差(SD值)及平均CT值,并计算SNR和对比噪声比(CNR)。采用Likert 5分制评估图像质量,通过Kappa方法评价观察者间的一致性。对FBP图像和10组ASIR图像测量结果进行方差分析,对图像噪声和ASIR取值进行相关分析。结果客观分析:①10%~100%ASIR图像的SD值小于FBP组(P<0.05),对应图像的SD值分别降低5.79%、11.44%、16.92%、21.78%、26.85%、32.12%、37.45%、40.32%、43.89%、47.27%;而图像CT值差异无统计学意义;②30%~100%ASIR各组图像SNR值高于FBP组(P均<0.05);③40%~100%ASIR各组图像CNR值高于FBP组(P均<0.05);④40%、50%、60%ASIR各组间SD值、SNR值及CNR值差异均无统计学意义(P>0.05);⑤图像噪声与ASIR百分比呈负相关(r=-0.613,P<0.05)。主观分析:①图像评定结果的观察者间一致性中等(Kappa=0.483);②30%~70%ASIR图像评分值高于FBP组(P<0.05),其中40%、50%、60%ASIR图像评分较高。结论与FBP相比,ASIR技术可降低青年骶髂关节CT噪声,有效改善图像质量;ASIR取值为40%~60%时可获得最佳图像质量。  相似文献   

8.
目的探讨Flash CT低管电压结合迭代重建(IRIS)技术对改善超重患者冠状动脉成像图像质量及降低辐射剂量的价值。方法对100例体质量指数(BMI)为25~30kg/m2的患者行Flash CT检查,按扫描管电压随机化分成A(120kV)、B(100kV)两组,对B组图像经IRIS重建获得数据作为C组。测量主动脉根部、左冠状动脉及右冠状动脉起始部血管腔内CT值、噪声(SD),并计算SNR、CNR,记录有效辐射剂量(ED)。结果 3组图像优良率比较差异有统计学意义(χ2=7.604,P<0.05);3组血管腔强化CT值、噪声、SNR、CNR差异均有统计学意义(P均<0.05)。两两比较,血管腔内CT值B、C两组高于A组;B组噪声最大,CNR最低;C组SNR最高。A、C组ED分别为(8.6±1.3)mSv和(3.5±0.7)mSv,差异有统计学意义(t=-16.91,P<0.05)。结论对于超重患者运用低管电压结合IRIS技术进行Flash CT冠状动脉检查能够获得较好的图像质量,显著降低辐射剂量。  相似文献   

9.
目的 探讨自适应统计迭代重建(ASiR)算法在儿童头部CT扫描中的应用价值。方法 对1个水模进行CT扫描,管电压100 kV,管电流分别为200、180、160、140、120和100 mA,ASiR比例分别设置为0、10%、20%、30%、40%、50%,采用FBP和ASiR迭代重建两种重建算法进行图像重建,比较不同条件下图像CNR、SNR和图像噪声。将80例接受头部CT扫描的患儿分为对照组(n=40)和试验组(n=40)。对照组采用管电压100 kV、管电流200 mA,FBP重建算法进行图像重建;试验组采用管电压100 kV、管电流140 mA,分别采用FBP和ASiR两种重建法进行图像重建;将重建后的图像分别记为试验FBP亚组和试验ASiR亚组;对两组中图像的CNR、SNR、图像噪声、CTDIvol、DLP、ED进行比较。结果 水模研究中,采用ASiR(30%)、管电流140 mA、ASiR算法重建图像的SNR、CNR及空气噪声值与管电流 200 mA、FBP重建图像最为接近。对照组与试验ASiR亚组图像的图像噪声、灰白质CNR和灰质SNR值差异均无统计学意义(P均>0.05);对照组和试验ASiR亚组图像的噪声、灰质SNR、灰白质CNR均优于试验FBP亚组,且差异均有统计学意义(P均<0.001)。结论 采用ASiR重建算法的头部CT扫描,既可降低患儿接受的辐射剂量,又保证了图像质量,具有较高的临床应用价值。  相似文献   

10.
目的 探讨超低管电流三维自适应迭代剂量降低(AIDR3D)重建CT猪结肠成像的图像质量与辐射剂量。方法 制作10段猪结肠息肉模型,每段猪结肠黏膜设有30枚直径1~15 mm的结节样模拟息肉。对所有模型均采用640层CT机进行扫描,管电压120 kVp,电流剂量分别为10、20、30、40、50 mAs。并获得滤波反投影(FBP)和AIDR3D重建图像,不同管电流及重建方法组合10组数据:A组(10 mA,FBP)、B组(10 mAs,AIDR3D)、C组(20 mAs,FBP)、D组(20 mAs,AIDR3D)、E组(30 mAs,FBP)、F组(30 mAs,AIDR3D)、G组(40 mAs,FBP)、H组(40 mAs,AIDR3D)、I组(50 mAs,FBP)、J组(50 mAs,AIDR3D)。测算图像的噪声、SNR及CNR作为定量指标,并对图像质量进行主观定性评分。以有效辐射剂量为指标比较各组图像的辐射剂量。结果 相同管电流条件下,AIDR3D图像的噪声低于FBP图像,SNC及CNR均高于FBP图像(P均<0.05)。D组与I组图像的噪声(P=0.052)、SNR(P=0.129)及CNR(P=0.053)差异均无统计学意义。B组图像的噪声(P=0.002)高于I组,SNR及CNR均低于I组(P均<0.001)。相同管电流条件下,AIDR3D图像的质量评分高于FBP图像(P均<0.05)。D组与I组的图像质量评分差异无统计学意义(P=0.121)。B组的图像质量评分低于I组(P<0.001)。 与I组(50 mAs,FBP)比较,D组(20 mAs,AIDR3D)的有效辐射剂量降低了59.90%,差异有统计学意义(P<0.05)。结论 超低管电流(20 mAs)扫描结合AIDR3D重建的猪结肠CT图像质量可媲美常规低管电流(50 mAs)扫描结合FBP重建的图像质量,并有效减低辐射剂量。  相似文献   

11.
To assess the image quality of coronary CT angiography (CCTA) of 640-slice CT reconstructed by Adaptive Iterative Dose Reduction (AIDR) three-dimensional (3D) in comparison with the conventional filtered back-projection (FBP). CCTA images of 51 patients were scanned at the lowest tube voltage possible on condition that the built-in automatic exposure control system could suggest the optimal tube current. They were, then, reconstructed with FBP and AIDR 3D (standard). Objective measurements including CT density, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were performed. Subjective assessment was done by two radiologists, using a 5-point scale (0:nondiagnostic-4:excellent) based on the 15-coronary segment model which was grouped into three parts as the proximal, mid, and distal segmental classes. Radiation dose was also measured. AIDR images showed lower noise than FBP images (45.0 ± 9.4 vs. 73.4 ± 14.6 HU, p < 0.001) without any significant difference in CT density (665.5 ± 131.7 vs. 668 ± 136.3 HU, p = 0.8). Both SNR (15.0 ± 2.1 vs. 9.2 ± 1.7) and CNR (16.8 ± 2.3 vs. 10.4 ± 1.8) were significantly higher for AIDR than FBP (p < 0.001). Total subjective image quality score was also significantly improved in AIDR compared with FBP (3.1 ± 0.6 vs. 1.6 ± 0.4, p < 0.001), with better interpretability of the mid and distal segmental classes (100 vs. 95 % for the mid, p < 0.001; 100 vs. 90 % for the distal, p < 0.001). Mean effective radiation dose was 2.0 ± 1.0 mSv. The AIDR 3D reconstruction algorithm reduced image noise by 39 % compared with the FBP without affecting CT density, thus improving SNR and CNR for CCTA. Its advantages in interpretability were also confirmed by subjective evaluation by experts.  相似文献   

12.
To investigate the image quality and the minimum required radiation dose for automatic tube potential selection (ATPS) in dual-source computed tomography (DSCT) coronary computed tomography angiography (CCTA). Three hundred twenty-five consecutive patients (153 men and 172 women) undergoing CCTA were assigned to either the ATPS group (n = 172) or the control group (n = 153); the control group underwent imaging at a constant current of 120 kV. All patients were scanned in either prospectively ECG-triggered high-pitch helical mode or sequential mode. The subjective image quality score, attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), volume CT dose index (CTDIvol), and effective dose (ED) were compared between the two groups with the Student t test or Mann–Whitney U test. The subjective image quality score was not significantly different between the two groups. Imaging noise and attenuation were both significantly higher in the ATPS group than in the control group (imaging noise: 25.6 ± 7.6 versus 15.8 ± 4.0 HU, P < 0.001; attenuation: 559.6 ± 142.0 versus 412.5 ± 64.3 HU, P < 0.001). SNR and CNR were significantly lower in the ATPS group than in the control group (SNR: 23.21 ± 7.40 versus 27.71 ± 8.25, P < 0.001; CNR: 27.81 ± 8.44 versus 33.94 ± 9.69, P < 0.001). ED was significantly lower in the ATPS group than in the control group (ED: 1.25 ± 1.24 versus 2.19 ± 1.77 mSv, P < 0.001). For both groups, ED was significantly lower in the high-pitch mode than in the sequential mode. The use of ATPS for CCTA significantly reduced the radiation dose while maintaining image quality.  相似文献   

13.
To evaluate the feasibility of low-concentration contrast medium (CM) for vascular enhancement, image quality, and radiation dose on computed tomography aortography (CTA) using a combined low-tube-voltage and iterative reconstruction (IR) technique. Ninety subjects underwent dual-source CT (DSCT) operating in dual-source, high-pitch mode. DSCT scans were performed using both high-concentration CM (Group A, n = 50; Iomeprol 400) and low-concentration CM (Group B, n = 40; Iodixanol 270). Group A was scanned using a reference tube potential of 120 kVp and 120 reference mAs under automatic exposure control with IR. Group B was scanned using low-tube-voltage (80 or 100 kVp if body mass index ≥25 kg/m2) at a fixed current of 150 mAs, along with IR. Images of the two groups were compared regarding attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), iodine load, and radiation dose in various locations of the CTA. In comparison between Group A and Group B, the average mean attenuation (454.73 ± 86.66 vs. 515.96 ± 101.55 HU), SNR (25.28 ± 4.34 vs. 31.29 ± 4.58), and CNR (21.83 ± 4.20 vs. 27.55 ± 4.81) on CTA in Group B showed significantly greater values and significantly lower image noise values (18.76 ± 2.19 vs. 17.48 ± 3.34) than those in Group A (all Ps < 0.05). Homogeneous contrast enhancement from the ascending thoracic aorta to the infrarenal abdominal aorta was significantly superior in Group B (P < 0.05). Low-concentration CM and a low-tube-voltage combination technique using IR is a feasible method, showing sufficient contrast enhancement and image quality.  相似文献   

14.
目的 探讨应用模型基础的迭代重建(MBIR)算法优化腹部CT静脉成像(CTV)图像质量的价值.方法 应用自动管电流调节技术对27例可疑腹部病变患者行腹部CT扫描,分别采用滤波反投影技术(FBP组)、50%自适应统计迭代重建(ASiR组)和MBIR(MBIR组)3种算法对原始数据进行重建;测量背部肌肉、背部脂肪、肝实质、胰腺实质、脾实质的噪声及CT值,计算门静脉、胰静脉、脾静脉及下腔静脉的CNR;采用5分制对图像质量进行评分.采用方差分析和秩和检验对数据进行统计学分析.结果 3组图像CT值的差异无统计学意义(P均>0.05).MBIR组图像噪声低于ASiR组(P<0.001),而二者均低于FBP组(P均<0.05);与FBP组图像相比,ASiR组和MBIR组图像噪声分别降低28.61%和53.53%,CNR分别增加40.92%和158.85%.MBIR组、ASiR组和FBP组的主观评分分别为(4.64±0.31)分、(3.74±0.54)分及(3.22±0.60)分,差异有统计学意义(P=0.008).结论 MBIR重建算法可以明显提高腹部CTV图像质量,并具有降低腹部CTV辐射剂量的潜能.  相似文献   

15.
The purpose of this study is to compare CT images of the pancreas reconstructed with model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASiR), and filtered back projection (FBP) techniques for image quality and pancreatic duct (PD) depiction. Data from 40 patients with contrast-enhanced abdominal CT [CTDIvol: 10.3 ± 3.0 (mGy)] during the late arterial phase were reconstructed with FBP, 40% ASiR–FBP blending, and MBIR. Two radiologists assessed the depiction of the main PD, image noise, and overall image quality using 5-point scale independently. Objective CT value and noise were measured in the pancreatic parenchyma, and the contrast-to-noise ratio (CNR) of the PD was calculated. The Friedman test and post-hoc multiple comparisons with Bonferroni test following one-way ANOVA were used for qualitative and quantitative assessment, respectively. For the subjective assessment, scores for MBIR were significantly higher than those for FBP and 40% ASiR (all P < 0.001). No significant differences in CT values of the pancreatic parenchyma were noted among FBP, 40% ASiR, and MBIR images (P > 0.05). Objective image noise was significantly lower and CNR of the PD was higher with MBIR than with FBP and 40% ASiR (all P < 0.05). Our results suggest that pancreatic CT images reconstructed with MBIR have lower image noise, better image quality, and higher conspicuity and CNR of the PD compared with FBP and ASiR.  相似文献   

16.
目的 探讨基于原始数据的迭代重建(SAFIRE)技术在眼眶CT平扫中的价值。方法 对50例眼部外伤患者行眼眶CT平扫,分别采用用滤过反投影(FBP)和SAFIRE(强度1~5级)技术重建图像;对比分析6种重建图像的平均CT值、噪声、SNR、CNR、图像质量评分及病变检出率。结果 6种重建图像间,同种组织CT值差异无统计学意义(P均>0.05);与FBP图像相比,1~5级SAFIRE图像中视神经噪声分别降低15.69%、27.39%、36.17%、41.75%和53.99%,视神经SNR分别提高18.62%、37.46%、55.70%、69.55%和118.11%,CNR分别提高21.59%、32.90%、56.43%、83.91%和104.39%(P均<0.05);SAFIRE 1级和 5级图像的质量评分低于FBP图像,2~4级图像的质量评分高于FBP图像,SAFIRE 3级图像评分最高。结论 眼眶CT平扫中应用SAFIRE能有效降低噪声和提高图像质量。  相似文献   

17.
目的 探讨不同迭代重建技术在超低剂量肺动脉成像中的应用价值。方法 对30例临床疑似肺动脉栓塞患者行CT肺动脉成像,扫描采用80 kV管电压并开启自动管电流调制技术,分别采用滤波反投影法(FBP)、iDOSE4、迭代模型重建(IMR)重建图像。采用5分制评价肺动脉主干及其分支的图像质量,测量计算图像噪声值、SNR、CNR,记录CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)、计算有效剂量(ED)。比较不同重建技术图像噪声、SNR、CNR及主观图像质量。结果 30例患者的平均体质量指数(BMI)为(25.12±2.48)kg/m2;平均CTDIvol为(0.78±0.28)mGy;平均DLP为(30.46±11.34)mGy·cm,平均ED为(0.43±0.16)mSv。IMR、iDOSE4、FBP图像噪声依次增高(P<0.05),SNR、CNR依次降低(P<0.05),CT值差异无统计学意义(P>0.05)。IMR、iDOSE4图像的主观评分显著高于FBP(P<0.05);IMR、iDOSE4图像可诊断率高于FBP(P<0.05),IMR图像优良率高于iDOSE4(P<0.05)。结论 采用80 kV联合IMR可保证肺动脉成像较高的图像质量,同时大大降低患者辐射剂量。  相似文献   