1.
A new rate adaptive pacemaker (Sensorithm) controlled by an activity sensor providing electrical signals induced by a magnetic ball moving freely in an elliptical cavity surrounded by two copper coils, was implanted in ten patients; mean age of 75 years (range 64–89). Six patients had atrioventricular block and four had sinus node disease. In auto-set testing procedure during a 1-minute walk in the corridor, a slope resulting in a maximum rate of 95 beats/min was selected in every patient, and a medium reaction time was programmed. During graded treadmill exercise tests the heart rate increased 63 ± 7 beats/min to 135 ± 6 beats/min in rate adaptive pacing mode (VVIR), and 15 ± 6 beats/min (P < 0.0001) in ventricular pacing mode (VVI). The symptom-limited exercise time was 9.1 ± 1.1 minutes and 8.2 ±1.2 minutes (P = NS), and the exercise distance was 501 ± 95 meters and 428 ± 92 meters (P < 0.05) in VVIR and VVI pacing mode, respectively. The maximum oxygen uptake was 20.6 ± 2.6 mL/kg per minute in VVIR pacing and 18.1 ± 2.1 mL/kg per minute (P < 0.05) in VVI pacing. The delay time until the pacing rate increased 10% of the total rate increase at onset of treadmill exercise was 4.4 ± 0.7 seconds. Assuming a linear relation between metabolic workload and heart rate response from rest to the age predicted maximum heart rate, a deviation of heart rate ranging from 13.5 ± 11.2% to –1.6 ± 5.2% from the expected heart rate at mid-point and endpoint of each quartile of workload was observed during treadmill testing. Conclusions : By using a 1 -minute walk test for selecting an appropriate slope setting, Sensorithm provided a significant and proportional heart rate increase during exercise resulting in an improvement of exercise capacity during VVIR pacing compared to VVI pacing.  相似文献   

2.
The EXCEL VR, an accelerometer-based pacemaker (AC), and the Legend, a pacemaker utilizing a piezoelectric crystal (PZ), were compared under ergometric conditions and during stair climbing to assess the appropriateness of their rate responses. The pacemakers, programmed to the manufacturers' nominal settings in order to compare different technologically based sensors under identical conditions, were strapped over subjects' left mid-pectoral region. Placement of the devices was randomized to control for positional effects. Ten healthy subjects (55-72 years) completed a graded exercise treadmill test to 80% of maximum predicted heart rate (HR). An additional group of ten subjects (50-66 years) completed exercise protocols involving bicycle ergometry and stair climbing. Throughout all tests, pacemaker pulse rates and subjects' intrinsic HR were monitored continuously. For the treadmill exercise, the average correlations between the AC and PZ pacemakers' pulse rate and HR for the group as a whole were r = 0.92 and r = 0.82, respectively. Individual subject comparisons were also made between each pacemaker rate and intrinsic HR. The mean difference from intrinsic rate was 11 ppm for the AC pacemaker and 24 ppm for the PZ pacemaker. In addition, the PZ pacemaker's maximal pulse rate was significantly lower (105 +/- 9.6 ppm) than the other two rates (AC 137 +/- 6 ppm; intrinsic HR 129 +/- 2 beats/min). Throughout the bicycle ergometry testing, the intrinsic HR was higher than the AC and PZ pacing rates. However, the AC's rate was significantly higher than the PZ's rate. When subjects ascended stairs, the intrinsic HR and AC rate were closely correlated, but the PZ rate was significantly lower.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
Fourteen patients were implanted with a single chamber dual sensor pacemaker (Legend Plus®) that measures minute ventilation (VE) via variations in impedance between a bipolar lead and the pacemaker case, and activity via a piezoelectric crystal bonded to the pacemaker case. Chronotropic incompetent patients were exercised an a treadmill and a bicycle in dual sensor mode. Activity only indicated pacing rate was measured using a strap-on pacemaker. Both implanted and strap on pacemakers were adjusted to yield a steady-state pacing rate of 100 beats/min during hall walk. Pacing rate, VE, and oxygen uptake (VO2) were measured continuously. Linear curve fit analysis slopes for plots of VE versus pacing rate during exercise (1.33-1.49) compared favorably to values reported in normals. Peak pacing rates achieved for treadmill and bicycle testing for dual sensor mode were higher than activity mode alone. Slopes of heart rate to VE or VO2 were not significantly different (P < 0.05) for dual sensor mode in contrast to activity alone. In conclusion, the Legend Plus dual sensor rate adaptive pacing therapy delivered pacing rates more proportional to VE and VO2 under different types of exercise than rates indicated by a strap-on pacemaker in activity mode.  相似文献   

4.
There are few practical guidelines for proper adjustment of rate responsive pacemaker sensor parameters. This study describes the application of the chronotropic assessment exercise protocol (CAEP) and the Wilkoff model of chronotropic response to assess the adjustment of pacemaker sensor parameters. In 31 patients implanted 1 month previously with a dual sensor pacemaker, pacemaker sensor parameters were adjusted to yield a peak sensor rate of 100 beats/min on a simple 6-minute walk (low intensity treadmill exercise [LITE] protocol); the maximum sensor rate was set to the age predicted maximum heart rate (220-age). The rate response behavior of the pacemaker was then assessed using the slope of metabolic-chronotropic relation (MCR) during CAEP exercise. After adjustments based on the LITE protocol, CAEP exercise yielded MCR slopes of 0.92 +/- 0.25 for the entire study group, which compares well with the predicted normal slope of 1. However, 7 of the 31 patients had sensor MCR slopes during CAEP exercise that were 2 SD or more below expected. To test the sensitivity of this approach to suboptimal pacemaker programming or suboptimal exercise, simulations were performed with the maximum sensor rate programmed below age-predicted maximum heart rate or with exercise truncated before maximum exertion; with these conditions, MCR slopes were sharply lower for the entire group. The authors conclude that a simple treadmill walk (LITE) allowed for optimum programming of sensor parameters in most patients, but in a minority the chronotropic behavior was underresponsive. Failure to appropriately adjust pacemaker maximum sensor rate or failure to achieve peak exercise sharply limits the accuracy of this methodology.  相似文献   

5.
The LEGEND-PLUS, a new rate adaptive pacemaker that combines activity and minute ventilation sensing for automatic rate adaptation was implanted in the right ventricle (VVIR) in 11 patients (mean age 62 ± 9 years). Initial programming was performed using the Programmer Exercise Protocol (a 3-minute walk). This programming was evaluated by treadmill tests, up-stairs and down-stairs walking, and Holier recordings. Results: Following the final programming of LEGEND-PLUS, the mean upper activity rate was 102 ± 7 beats/rain (range 90–120 beats/min), while the mean upper minute ventilation rate was 125 ± 16 beats/min (range 100–150 beats/min). The mean rate responses during the exercise protocol and the final programming in minute ventilation and activity sensing modes were 5.4 ± 2.3 (range 1–9), versus 4 ± 2.4 (range 1–8; P < 0.01) and 7.6 ±1.1 (range 5–9), versus 7.5 ± 0.8 (range 6–9; P = 0.8), respectively. In the combined sensing mode, the acceleration rate was identical to the activity rate response and the deceleration rate mimicked the minute ventilation. Conclusion: Dual sensor VVIR pacemakers have the potential to improve rate adaptation to exercise. The rate response to exercise in patients fitted with activity and minute ventilation sensors, VVIR pacemakers closely mimics the physiological rate response.  相似文献   

6.
A group of 301 apparently healthy men and women were studied using bicycle ergometry in order to obtain generally applicable reference values for clinical exercise testing. The subjects, aged 30-67 years, were derived from a comprehensive health survey carried out on a population sample representative of adult Finns. The exercise test was a standardized heart rate conducted programme in which workload was regulated so as to increase heart rate by 5 beats/min every min up to subjective maximum. Three indicators of exercise capacity are presented: maximal workload (Wmax), mean workload attained during the last 4 min of the test (W]as,4) and hypothetical maximal workload sustainable for 6 min (Wmax6.). All showed wide inter-individual variation even when related to age and body weight. The ergometric results depended significantly on age and height in men and on age and weight in women. We present formulas for the calculation of expected values of Wlast4 and Wmax6- on the basis of sex, age, height and weight. We suggest that the measured values be given in percentages of those expected.  相似文献   

7.
MEINE, M., et al. : Assessment of the Chronotropic Response at the Anaerobic Threshold: An Objective Measure of Chronotropic Function. The evaluation of the heart rate response to exercise is important for the diagnosis of chronotropic incompetence and the assessment of a rate responsive algorithm of sensorcontrolled pacemakers. The aim of the present study was to examine a classification of the chronotropic response at an individually moderate exercise level. Sixteen pacemaker patients (patient group, age 62.9 ± 7.6 years ) with sick sinus syndrome and 15 age‐matched healthy subjects (control group, age 57.6 ± 9.4 years ) underwent a maximum cardiopulmonary exercise test on a treadmill after a protocol with individually selected incremental steps. To analyze the patients' intrinsic heart rate response, the rate responsive mode of the pacemaker was switched off. Chronotropic incompetence was diagnosed in eight patients whose maximal heart rate was < 80% of the age‐predicted heart rate. The heart rate at the anaerobic threshold was significantly lower in the chronotropically incompetent subgroup than in the chronotropically competent patients and the healthy subjects (85.9 ± 6.6 beats/min vs 100.3 ± 9.9 beats/min and 112.9 ± 11.7 beats/min , respectively). The chronotropic slope of the heart rate reserve as a function of the metabolic reserve was significantly higher in the control group than in the patient groups with either mild or severe chronotropic incompetence (0.94 ± 0.17 vs 0.64 ± 0.08 and 0.43 ± 0.14 , respectively). Furthermore, the chronotropically incompetent response could be divided into a linear type with and without a threshold, an exponential, and a logarithmic type. The anaerobic threshold was an objectively detectable breakpoint at an individually moderate exercise level that could be used for characterization of chronotropic function. At the anaerobic threshold, a physiological heart rate response was about 220 ‐ age – 50 beats/min. A deviation of more than 10 beats/min below this physiological value characterized chronotropic incompetence.  相似文献   

8.
The normal heart rate is lineurly related to oxygen consumption during exercise. The maximum heart rate of the normal sinus node is approximated by the formula: HRmax= (220-age) with a variance of approximately 15%. However, the nominal upper rate of most permanent pacemakers is 120 beats/min, a value that remains unchanged for many patients. As this nominal setting falls well below the maximum predicted heart rate for most patients, it is possible that the chronotropic response of rate adaptive pacemakers during moderate und maximal exercise workloads may be less than optimal. The purpose of this study was to determine the effect of the upper programmed rate on oxygen kinetics during submaximal exercise workloads and maximum exercise performance during symptom-limited treadmill exercise. Exercise performance with an upper rate programmed to 220-age was compared with an upper rate of 120 beats/min. Eleven patients (5 men and 6 women, mean age 54 ± 10 years) with complete heart block following catheter ablation of the atrioventricular junction for refractory atrial fibrillation who were implanted with permanent, rate-modulating VVIR pacemakers comprised the study population. The rate adaptive sensors were based on activity in 8 patients, minute ventilation in 2 patients, and mixed venous oxygen saturation in 1 patient. After performing a symptom-limited treadmill exercise test to determine maximum exercise capacity and to optimize programming of the rate adaptive sensor, each subject performed two treadmill exercise tests in random sequence with a rest period of at least 1 hour between tests. During one of the tests the upper rate was programmed to a value calculated by the formula: HRmax= (220-age). During the other exercise test the upper rate was programmed to 120 beats/min. Patients were blinded as to their programmed values and to the hypothesis of the study. A novel treadmill exercise protocol was used that consisted of a 6 minute, constant-workload phase at approximately 50% of maximum workload followed immedictely by incremental, symptom-limited exercise using a modified Chronotropic Assessment Exercise Protocol (CAEP) with 1 minute stages until peak exertion. Breath-by-breath analysis of expired gases was performed with subjective scoring of exertional difficulty at the end of the constant workload phase and during each stage of incremental exercise using the Borg Perceived Exertion Scale. Exercise duration was significantly longer (6.37 ± 47 vs 611 ±48 seconds. P < 0.005) with the higher programmed upper rate. Oxygen kinetics were also significantly improved with an age predicted upper rate with a lower O2 deficit (258 ± 88 vs 395 ± 155 ml, P = 0.002) and higher VO2 rate constant (3.6 ± 1.0 vs 2.4 ± 0.7. P < 0.001.). The V02maxduring peak exertion was higher with an age predicted upper rate than with an upper rate of 120 beats/min (1807 ± 751 vs 1716 ± 702 mL/min, P = 0.01). The mean Borg score was lower during the last common treadmill stage during maximum exercise with an age predicted upper rate than with an upper rate of 120 beats/min (15.7 ± 2.0 vs 16.5 ± 1.9. P = 0.04). The mean Borg score during submaximal. constant workload exercise was also lower with a higher upper rate (9.0 ±2.5 vs 9.6 ± 2.2, P = 0.10). Programming the upper rate of rate adaptive pacemakers based on the age of the patient improves exercise performance and exertional symptoms during both low and high exercise workloads as compared with a standard nominal value of 120 beats/min.  相似文献   

9.
Ong KC  Chong WF  Soh C  Earnest A 《Respiratory care》2004,49(12):1498-1503
INTRODUCTION: Common modalities of clinical exercise testing for outcome measurement after pulmonary rehabilitation (PR) include walk tests, progressive cycle ergometry, and cycle endurance testing. We hypothesized that patients' responses to PR, as measured by those 3 tests, are differentially correlated, and we designed a study to investigate the tests' capacity to detect changes after PR. METHODS: We prospectively tested 37 male patients with stable chronic obstructive pulmonary disease who completed a comprehensive 6-week PR program that included supervised exercise training that emphasized steady-state lower-limb aerobic exercise. Before and after the PR program the patients underwent 6-minute walk test, progressive cycle ergometry, and cycle endurance testing (at 80% of the peak work rate achieved during progressive cycle ergometry). The exercise performance indices of interest were the peak oxygen uptake (VO2max) and maximum work-rate (Wmax) during progressive cycle ergometry, the cycling endurance time, and the 6-minute walk distance (6MWD). RESULTS: After PR there were statistically significant improvements in 6MWD (16%, p <0.001), VO2max (53%, p=0.004), Wmax (30%, p=0.001), and cycling endurance time (144%, p <0.001). The changes in VO2max and Wmax were significantly correlated (r=0.362, p=0.027), as were the changes in endurance time and Wmax (r=0.406, p=0.013). There was no significant correlation between changes in any other exercise index. CONCLUSIONS: Among the frequently used exercise tests in PR, the most responsive index is the endurance time. The correlation between the post-PR changes in the various exercise indices is poor.  相似文献   

10.
Rate adaptive pacing has been shown to improve hemodynamic performance and exercise tolerance during acute testing. However, there remain concerns about its benefit in daily life and possible complications incurred by unnecessary pacing. This double-blind crossover study compared the benefit of rate adaptive (SSIR) versus fixed rate (SSI) pacing under laboratory and daily life conditions in 20 rate incompetent patients with minute ventilation single chamber pacemakers (META II). The heart rate (HR) response during three different exercise tests (treadmill, bicycle ergomctry, walking test) was correlated with the Holler findings during daily life in either pacing mode. The maximal HR was significantly higher in the SSIR-mode compared to the SSI-mode, both during laboratory testing (treadmill: 123 ± 15 vs 93 ± 29 beats/min: ergometry: 118 ± 15 vs 89 ± 27 beats/min; walking test: 127 ± 9 vs 95 ± 26 beats/min, all P values < 0.01) as well as during daily life (Holter: 126 ± 13 vs 103 ± 24 beats/min, P < 0.01). On Holter, the average HR (71 ± 14 vs 71 ± 8 beats/min) and the percentage of paced rhythm (54 % vs 62%, SSI- vs SSIR-mode, P = NS) were not different in either mode. However, despite a 30% rate gain in the SSIR-mode, the exercise capacity remained unchanged, and only 38% of patients preferred the SSIR-mode. Minute ventilation pacemakers provide a physiological rate response to exercise. Irrespective of the protocol used, the findings of laboratory testing are comparable to those during daily life. However, patient selection for rate adaptive single chamber pacing should be made with caution, since the objective benefit of restoring normal chronotropy may subjectively be negligible for most patients.  相似文献   