首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 140 毫秒
1.
The in vivo assessment of the biomechanical properties of the skeletal muscle is a complex issue because the muscle is an anisotropic, viscoelastic and dynamic medium. In this article, these mechanical properties are characterized for the brachialis muscle in vivo using a noninvasive ultrasound-based technique. This supersonic shear imaging technique combines an ultra-fast ultrasonic system and the remote generation of transient mechanical forces into tissue via the radiation force of focused ultrasonic beams. Such an ultrasonic radiation force is induced deep within the muscle by a conventional ultrasonic probe and the resulting shear waves are then imaged with the same probe (5 MHz) at an ultra-fast framerate (up to 5000 frames/s). Local tissue velocity maps are obtained with a conventional speckle tracking technique and provide a full movie of the shear wave propagation through the entire muscle. Shear wave group velocities are then estimated using a time of flight algorithm. This approach provides a complete set of quantitative and in vivo parameters describing the muscle’s mechanical properties as a function of active voluntary contraction as well as passive extension of healthy volunteers. Anisotropic properties are also estimated by tilting the probe head with respects to the main muscular fibers direction. Finally, the dispersion of the shear waves is studied for these different configurations and shear modulus and shear viscosity are quantitatively assessed assuming the viscoelastic Voigt’s model. (E-mail: jl.gennisson@espci.fr)  相似文献   

2.
Completely computer-focused ultrasound imaging has been achieved using the UHB (ultrasound holographic B) method. This is a synthetic aperture method that combines ultrasonic holography and the conventional B-scan method. A wide-angle ultrasound burst (4 MHz) is transmitted into the object and the reflected echoes are measured as a function of the propagation time, but both the amplitude and phase angle are recorded, giving multiple one-dimensional holograms in a cross-sectional plane. This UHB data is rearranged to obtain one-dimensional wave fields, which represent the wave fronts reflected from each depth. The image is then reconstructed by propagating these wave fields backward to their original positions on the image using Fourier transform, a spectrum shift theorem, and inverse Fourier transform. The whole UHB image is obtained by calculating the intensity lines from these wave fields and by scanning these lines one by on the cathode ray tube (CRT) monitor. Following extensive laboratory testing with single and multielement transducers, special 32- and 64-element linear array transducers were fabricated, as was computer software capable of producing a UHB image in 40 seconds. Tissue imaging tests followed by clinical imaging of 30 patients showed that images obtained with this prototype compared favorably with those obtained by state-of-the-art conventional ultrasound scanners. The potential advantages of the new method are enhanced lateral resolution and the incorporation of phase information in tissue characterization. This would be important in diagnostic and intraoperative, especially neurosurgical, imaging.  相似文献   

3.
Elastography is a modality that estimates tissue stiffness and, thus, provides useful information for clinical diagnosis. Attention has focused on the measurement of shear wave propagation; however, many methods assume shear wave propagation is unidirectional and aligned with the lateral imaging direction. Any deviations from the assumed propagation result in biased estimates of shear wave speed. To address these challenges, directional filters have been applied to isolate shear waves with different propagation directions. Recently, a new method was proposed for tissue stiffness estimation involving creation of a reverberant shear wave field propagating in all directions within the medium. These reverberant conditions lead to simple solutions, facile implementation and rapid viscoelasticity estimation of local tissue. In this work, this new approach based on reverberant shear waves was evaluated and compared with another well-known elastography technique using two calibrated elastic and viscoelastic phantoms. Additionally, the clinical feasibility of this technique was analyzed by assessing shear wave speed in human liver and breast tissues, in vivo. The results indicate that it is possible to estimate the viscoelastic properties in each scanned medium. Moreover, a better approach to estimation of shear wave speed was obtained when only the phase information was taken from the reverberant waves, which is equivalent to setting all magnitudes within the bandpass equal to unity: an idealization of a perfectly isotropic reverberant shear wave field.  相似文献   

4.
In this work, we explored the potential of measuring shear wave propagation using optical coherence elastography (OCE) based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a 20 MHz piezoelectric transducer (circular element 8.5 mm diameter) transmitting sine-wave bursts of 400 μs, synchronized with the OCT swept source wavelength sweep. The acoustic radiation force (ARF) was applied to two gelatin phantoms (differing in gelatin concentration by weight, 8% vs. 14%). Differential OCT phase maps, measured with and without the ARF, demonstrate microscopic displacement generated by shear wave propagation in these phantoms of different stiffness. We present preliminary results of OCT derived shear wave propagation velocity and modulus, and compare these results to rheometer measurements. The results demonstrate the feasibility of shear wave OCE (SW-OCE) for high-resolution microscopic homogeneous tissue mechanical property characterization.  相似文献   

5.
Deep venous thrombosis (DVT) affects millions of people worldwide. A fatal complication occurs when the thrombi detach and create a pulmonary embolism. The diagnosis and treatment of DVT depends on clot's age. The elasticity of thrombi is closely related to its age. Blood was collected from pigs and anticoagulated using ethylenediaminetetraacetic acid (EDTA). Coagulation was initiated using calcium ions. Supersonic shear wave imaging was used to generate shear waves using 100 μs tone bursts of 8 MHz. Tracking of the shear waves was done by ultrafast imaging. Postprocessing of the data was done using Matlab®. Two-dimensional (2-D) maps of elasticity were obtained by calculating the speed of shear wave propagation. Elasticity varied with time from around 50 Pa at coagulation to 1600 Pa at 120 min after which the elasticity showed a natural decreased (17%) because of thrombolytic action of plasmin. Ejection of the serum from the clot showed a significant decrease in the elasticity of the clot next to the liquid pool (65% decrease), corresponding to the detachment of the clot from the beaker wall. The use of a thrombolytic agent (Urokinase) on the coagulated blood decreased the shear elasticity close to the point of injection, which varied with time and distance. Supersonic imaging proved to be useful mapping the 2-D clot's elasticity. It allowed the visualization of the heterogeneity of mechanical properties of thrombi and has potential use in predicting thrombi breakage as well as in monitoring thrombolytic therapy.  相似文献   

6.
The propagation of shear waves from impulsive forces is an important topic in elastography. Observations of shear wave propagation can be obtained with numerous clinical imaging systems. Parameter estimations of the shear wave speed in tissues, and more generally the viscoelastic parameters of tissues, are based on some underlying models of shear wave propagation. The models typically include specific choices of the spatial and temporal shape of the impulsive force and the elastic or viscoelastic properties of the medium. In this work, we extend the analytical treatment of 2-D shear wave propagation in a biomaterial. The approach applies integral theorems relevant to the solution of the generalized Helmholtz equation, and does not depend on a specific rheological model of the tissue's viscoelastic properties. Estimators of attenuation and shear wave speed are derived from the analytical solutions, and these are applied to an elastic phantom, a viscoelastic phantom and in vivo liver using a clinical ultrasound scanner. In these samples, estimated shear wave group velocities ranged from 1.7?m/s in the liver to 2.5?m/s in the viscoelastic phantom, and these are lower-bounded by independent measurements of phase velocity.  相似文献   

7.
Monitoring thermally-induced lesions with supersonic shear imaging   总被引:1,自引:0,他引:1  
Thermally-induced lesions are generally stiffer than surrounding tissues. We propose here to use the supersonic shear imaging technique (SSI) for monitoring high-intensity focused ultrasound (HIFU) therapy. This new elasticity imaging technique is based on remotely creating shear sources using an acoustic radiation force at different locations in the medium. In these experiments, an HIFU probe is used to generate lesions in fresh tissue samples. A diagnostic transducer, controlled by our ultrafast scanner, is located in the therapeutic probe focal plane. It is used for both generating the shear waves and imaging the resulting propagation at frame rates reaching 5,000 images/s. Movies of the shear wave propagation can be computed off-line. The therapeutic and imaging sequences are interleaved and a set of wave propagation movies is performed during the heating process. From each movie, elasticity estimations have been performed using an inversion algorithm. It demonstrates the feasibility of detecting and quantifying the hardness of HIFU-induced lesions using SSI.  相似文献   

8.
Cardiac muscle stiffness can potentially be estimated non-invasively with shear wave elastography. Shear waves are present on the septal wall after mitral and aortic valve closure, thus providing an opportunity to assess stiffness in early systole and early diastole. We report on the shear wave recordings of 22 minipigs with high-frame-rate echocardiography. The waves were captured with 4000 frames/s using a programmable commercial ultrasound machine. The wave pattern was extracted from the data through a local tissue velocity estimator based on one-lag autocorrelation. The wave propagation velocity was determined with a normalized Radon transform, resulting in median wave propagation velocities of 2.2 m/s after mitral valve closure and 4.2 m/s after aortic valve closure. Overall the velocities ranged between 0.8 and 6.3 m/s in a 95% confidence interval. By dispersion analysis we found that the propagation velocity only mildly increased with shear wave frequency.  相似文献   

9.
This paper demonstrates the feasibility of in vivo quantitative mapping of liver viscoelasticity using the concept of supersonic shear wave imaging. This technique is based on the combination of a radiation force induced in tissues by focused ultrasonic beams and a very high frame rate ultrasound imaging sequence capable of catching in real time the transient propagation of resulting shear waves. The local shear wave velocity is recovered using a dedicated time-of-flight estimation technique and enables the 2-D quantitative mapping of shear elasticity. This imaging modality is performed using a conventional ultrasound probe during a standard intercostal ultrasonographic examination. Three supersonic shear imaging (SSI) sequences are applied successively in the left, middle and right parts of the 2-D ultrasonographic image. Resulting shear elasticity images in the three regions are concatenated to provide the final image covering the entire region-of-interest. The ability of the SSI technique to provide a quantitative and local estimation of liver shear modulus with a millimetric resolution is proven in vivo on 15 healthy volunteers. Liver moduli extracted from in vivo data from healthy volunteers are consistent with those reported in the literature (Young's modulus ranging from 4 to 7.5 kPa). Moreover, liver stiffness estimation using the SSI mode is shown to be fast (less than one second), repeatable (5.7% standard deviation) and reproducible (6.7% standard deviation). This technique, used as a complementary tool for B-mode ultrasound, could complement morphologic information both for fibrosis staging and hepatic lesions imaging (E-mail: jl.gennisson@espci.fr).  相似文献   

10.
Ultrasound techniques can be used to characterize and stimulate dental implant osseointegration. However, the interaction between an ultrasonic wave and the implant-bone interface (IBI) remains unclear. This study—combining experimental and numerical approaches—investigates the propagation of an ultrasonic wave in a dental implant by assessing the amplitude of the displacements along the implant axis. An ultrasonic transducer was excited in a transient regime at 10 MHz. Laser interferometric techniques were employed to measure the amplitude of the displacements, which varied 3.2–8.9 nm along the implant axis. The results demonstrated the propagation of a guided wave mode along the implant axis. The velocity of the first arriving signal was equal to 2110 m.s–1, with frequency components lower than 1 MHz, in agreement with numerical results. Investigating guided wave propagation in dental implants should contribute to improved methods for the characterization and stimulation of the IBI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号