 共查询到20条相似文献,搜索用时 64 毫秒
1.
AIM: To investigate the accuracy of intraocular pressure (IOP) as measured by a Reichert Ocular Response Analyzer (ORA), as well as the relationship between central corneal thickness (CCT) and IOP as measured by ORA, Goldmann applanation tonometry (GAT), and dynamic contour tonometry (DCT). METHODS: A total of 158 healthy individuals (296 eyes) were chosen randomly for measurement of IOP. After CCT was measured using A-ultrasound (A-US), IOP was measured by ORA, GAT, and DCT devices in a randomized order. The IOP values acquired using each of the three tonometries were compared, and the relationship between CCT and IOP values were analyzed separately. Two IOP values, Goldmann-correlated IOP value (IOPg) and corneal-compensated intraocular pressure (IOPcc), were got using ORA. Three groups were defined according to CCT: 1) thin cornea (CCT<520μm); 2) normal-thickness cornea (CCT: 520–580μm); and 3) thick cornea (CCT>580μm) groups. RESULTS: In normal subjects, IOP measurements were 14.95±2.99mmHg with ORA (IOPg), 15.21±2.77mmHg with ORA (IOPcc), 15.22±2.77mmHg with GAT, and 15.49±2.56mmHg with DCT. Mean differences were 0.01±2.29mmHg between IOPcc and GAT (P>0.05) and 0.28±2.20mmHg between IOPcc and DCT (P>0.05). There was a greater correlation between IOPcc and DCT (r=0.946, P=0.000) than that between IOPcc and GAT (r=0.845, P=0.000). DCT had a significant correlation with GAT (r=0.854, P=0.000). GAT was moderately correlated with CCT (r=0.296, P<0.001), while IOPcc showed a weak but significant correlation with CCT (r=?0.155, P=0.007). There was a strong negative correlation between CCT and the difference between IOPcc and GAT(r=-0.803,P=0.000), with every 10μm increase in CCT resulting in an increase in this difference of 0.35mmHg. The thick cornea group (CCT>580μm) showed the least significant correlation between IOPcc and GAT (r=0.859, P=0.000); while the thin cornea group (CCT<520μm) had the most significant correlation between IOPcc and GAT (r=0.926, P=0.000). The correlated differences between IOPcc and DCT were not significant in any of the three groups (P>0.05). CONCLUSION: Measurement of IOP by ORA has high repeatability and is largely consistent with GAT measurements. Moreover, the ORA measurements are affected only to a small extent by CCT, and are likely to be much closer to the real IOP value than GAT.  相似文献   

2.

Purpose

To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP.

Methods

This prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automated-endothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland–Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP.

Results

iCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, P<0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of −6.5±1.9 mm Hg, P<0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes.

Conclusions

The agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP.  相似文献   

3.

Aim

To determine the effect of contact lens induced oedema on the accuracy of Goldmann tonometry measurements of intraocular pressure (IOP) in mature subjects.

Methods

22 healthy subjects aged between 50 and 60 years were recruited. Corneal curvature, IOP, and central corneal thickness (CCT) were measured before and after two hours of monocular closed eye wear of a thick hydroxyethyl methacrylate (HEMA) contact lens. Measurements were then repeated at 20 minute intervals for one hour after lens removal.

Results

Both CCT (+54.1 μm) and IOP (+2.7 mm Hg) increased significantly after lens wear (p<0.001, paired t test with Bonferroni correction). For the hour following lens removal, the measured IOP was correlated to the increase in CCT (r = 0.84, p<0.001), at a rate of 1.0 mm Hg/10 μm (95% confidence interval, 0.8 to 1.2 mm Hg/10 μm, linear mixed model analysis).

Conclusions

A relatively small increase in CCT from contact lens induced corneal oedema caused an overestimation error in Goldmann tonometry measurements of IOP in healthy mature subjects.  相似文献   

4.

Purpose

To measure corneal hysteresis and intraocular pressure (IOP) in patients with dry eye and to compare with normal subjects.

Methods

This cross-sectional study consists of 70 eyes of 40 patients with dry eye (group 1) and 75 eyes of 40 normal subjects (group 2). Eyes were diagnosed as dry eye or normal according to the clinical symptoms, biomicroscopical evaluation, and Schirmer test. Corneal hysteresis (CH), corneal resistance factor (CRF), and cornea-compensated intraocular pressure (IOPcc) were measured by the Ocular Response Analyser (ORA).

Results

Mean CH values were 10.56±0.25 mm Hg and 10.34±0.26 mm Hg, mean CRF values were 10.75±0.28 mm Hg and 10.70±0.28 mm Hg, mean CCT values were 542±3.20 μm and 543±3.89 μm in group 1 and group 2, respectively. There was no statistically significant difference between the groups for these three parameters. IOPcc values measured with ORA were 15.73±0.36 mm Hg in group 1 and 16.60±0.33 mm Hg in group 2, and there was no statistically significant difference between the two groups.

Conclusions

Corneal biomechanical parameters such as CH and CRF are not influenced in dry eye. Also statistical difference was not found between the two groups according to CCT and IOPcc values.  相似文献   

5.

Purpose

To compare the intraocular pressures (IOPs) obtained with the IOPen rebound tonometer, Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) and investigate the effects of corneal biomechanical properties on IOPen measurements.

Methods

A total of 198 normal eyes were included in this cross-sectional and randomized study. Three measurements were taken using IOPen. Agreement between tonometers was calculated using the Bland and Altman limits of agreement (LoA) analysis.

Results

The median IOPen IOP was 3 mm Hg below the GAT (P<0.001), 3 mm Hg below the ORA IOP similar to Goldmann (IOPg), and 3 mm Hg below the ORA IOP corrected using corneal parameters (IOPcc)(P<0.01). The LoA width between the IOPen and GAT IOPs varied between 13.92 (mean IOPen IOP) and 15.99 mm Hg (third IOPen measurement). The central corneal thickness (CCT) was unrelated to IOPen measurements (P>0.05). Corneal hysteresis (CH) and corneal rigidity factor (CRF) were correlated with IOPen and GAT.

Conclusions

IOPen underestimated the IOP compared with GAT and ORA. The effect of measurement quality or measurement order on IOPen was low. CCT did not affect the IOPen, but the CH and CRF did. The LoA width between the IOPen and GAT IOPs was higher than between the ORA IOPg or ORA IOPcc and GAT IOPs.  相似文献   

6.

Pupose:

The purpose of this study was to compare the biomechanical properties of the cornea and intraocular pressure (IOP) between patients with systemic lupus erythematosis (SLE) and age-matched controls.

Patients and Methods:

In this prospective study, 30 healthy individuals (control group) and 30 patients with SLE (study group) underwent Reichert ocular response analyzer (ORA) measurements. In the right eye of each participant, the corneal hysteresis (CH), corneal resistance factor (CRF), and Goldman-related IOP (IOPg) were recorded using the ORA.

Results:

Mean CH, CRF, IOPg were significantly different between groups. Mean CH was 10.2±0.6 mm Hg in the study group and 11.3±1.3 in the control group (P=0.02); mean CRF was 9.7±1.1 mm Hg and 11.9±1.5 mm Hg, respectively (P=0.001). Mean IOPg was 13.9±2.9 mm Hg in the study group and 16.9±2.6 mm Hg in the control group (P=0.001).

Conclusion:

The biomechanical properties of the cornea are altered in patients with SLE compared with normal controls. These findings should be taken into account when measuring IOP values in patients with SLE as IOP readings may be underestimated in SLE eyes.  相似文献   

7.

Purpose

To investigate the effect of orbital decompression surgery in thyroid orbitopathy (TO) on both refractive status and intraocular pressure (IOP).

Patients and methods

A prospective, multicentre, consecutive audit of patients undergoing thyroid decompression surgery. Indications for surgery included cosmetically unacceptable proptosis or corneal exposure. Exclusion criteria included the following: previous orbital surgery, glaucoma, corneal disease, steroid use in the preceding 12 months, or an acute optic neuropathy. Automated refraction, keratometry, pachymetry, Hertel exophthalmometry, and IOP were recorded at 1 month pre- and 3 months postoperatively. IOP using the Tono-Pen (mean of three readings) was measured in the primary, upgaze, and downgaze positions.

Results

Data were collected from 52 orbits of 33 patients (East Grinstead, New York, and Adelaide). There was no significant difference between pre- and postoperative data for sphere, cylinder, or central corneal thickness (CCT). The mean spherical equivalent was −0.43±1.49 D pre-operatively and −0.28±1.52 D postoperatively. The steepest meridian of corneal curvature was 93.1 degrees pre- and 94.2 degrees postoperatively, with no significant difference. Mean IOP significantly decreased when measuring by Goldmann applanation tonometry (GAT) (2.28 mm Hg, * P=0.001) and Tono-Pen (3.06 mm Hg, * P=<0.0001). IOP measured in upgaze was significantly greater than that in the primary position. Regression analysis between change in IOP and either Hertel exophthalmometry or the number of orbital walls decompressed was non-significant (*Student''s t-test).

Conclusion

Patients with TO undergoing orbital decompression had, on average, with-the-rule astigmatism not affected by orbital decompression surgery. IOP was significantly reduced by decompression surgery although no relationship between IOP and the degree of decompression was observed.  相似文献   

8.

Purpose

To compare intraocular pressure (IOP) over time after standard trabeculectomy vsEx-PRESS implantation in patients with bilateral primary open-angle glaucoma (POAG).

Design

Prospective, randomised study.

Patients and methods

This study included adult patients with bilateral POAG necessitating surgery. Each patient underwent trabeculectomy in one eye and Ex-PRESS implantation under a scleral flap in the other eye according to randomised contralateral allocations. Efficacy was assessed by IOP values and success rates (IOP threshold and/or need for topical glaucoma medication) during 30 months. Statistical analysis included Generalised Estimate Equation and Cox Survival models, and paired t-tests.

Results

Thirty eyes of 15 patients were studied for a mean of 23.6 months (SD, ±6.9). At the last follow-up visit, mean pre-operative IOP decreased from 31.1 (±14.2) to 16.2 (±1.5) mm Hg after trabeculectomy, and from 28.1 (±9.0) to 15.7 (±1.8) mm Hg after Ex-PRESS implantation (P=0.001). The mean number of anti-glaucoma medicines prescribed at the last follow-up decreased from 3.7 pre-operatively (both groups) to 0.9 after trabeculectomy vs0.3 after Ex-PRESS implantation (P=0.001). Complete success rates (5P=0.0024). Postoperative complications were more frequent after trabeculectomy (33%) compared with Ex-PRESS (20%), with four trabeculectomy eyes (27%) needing postoperative interventions, compared with none with Ex-PRESS.

Conclusions

Trabeculectomy and Ex-PRESS implantation provided similar IOP control, but the Ex-PRESS group had a lower rate of complications, fewer postoperative interventions, and needed less glaucoma medications.  相似文献   

9.

Purpose

Given the Veterans Affairs Boston Healthcare System''s recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting.

Methods

Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test–retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements.

Results

The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3–34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=−1.05 was significantly different from the hypothesized value. The Tonosafe test–retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability.

Conclusions

The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.  相似文献   

10.

Purpose

The purpose of this study is to compare the safety and intraocular pressure (IOP)-lowering efficacy of travoprost/timolol in a benzalkonium chloride (BAK)-free fixed combination preserved with polyquaternium-1 (TRA/TIM BAK-free), with travoprost/timolol-fixed combination preserved with BAK (TRA/TIM), in patients with open-angle glaucoma or ocular hypertension.

Methods

In this prospective randomized controlled trial, subjects with IOP of at least 22 mm Hg in one or both eyes at 0900 h, and IOP of at least 21 mm Hg in one or both eyes at 1100 h and 1600 h at two eligibility visits were randomly assigned to receive either TRA/TIM BAK-free (n=195) or TRA/TIM (n=193), dosed once daily in the morning (0900 h) for 6 weeks. IOP was assessed at 0900 h, 1100 h, and 1600 h at each scheduled visit (baseline, 2 and 6 weeks after randomization).

Results

Mean IOP reduction across all visits and time points was 8.0 mm Hg in the TRA/TIM BAK-free group and 8.4 mm Hg in the TRA/TIM group (P=0.0943). The difference in mean IOP between groups ranged from 0.2 to 0.7 mm Hg across visits and time points, with a mean pooled difference of 0.4 mm Hg (95% CI: −0.1 to 0.8), demonstrating equivalence of the two formulations. The most common drug-related adverse event was hyperemia of the eye (ocular hyperemia and conjunctival hyperemia combined), occurring in 11.8% of the TRA/TIM BAK-free group and 13.0% of the TRA/TIM group.

Conclusion

Travoprost/timolol BAK-free demonstrated equivalence to travoprost/timolol preserved with BAK in efficacy. No clinically relevant differences in the safety profiles of travoprost/timolol BAK-free and travoprost/timolol preserved with BAK were identified.  相似文献   

11.

Purpose

To study the change in retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) parameters using optical coherence tomography (Stratus OCT 3) after trabeculectomy in adult patients with glaucoma.

Methods

A total of 17 patients with glaucoma undergoing trabeculectomy were recruited. Average and quadrant RNFL thickness measurements, vertical integrated rim area, horizontal integrated rim width, disc area, cup area, and rim area were measured using Stratus OCT within a week before surgery and at 1 week, 1 and 3 months postoperatively. Main outcome measures were change in RNFL and ONH parameters. Pre- and postoperative values were analysed using the Wilcoxon signed-rank test.

Results

Intraocular pressure (IOP) reduced from 30.23±9.02 mm Hg preoperatively to 9.52 ±2.42 mm Hg at 1 week, 12.35±4.59 mm Hg at 1 month, and 13.6 ±2.31 mm Hg at 3 months after trabeculectomy. A significant increase in average (P=0.019) and inferior RNFL (P=0.038) thickness was observed 1 week after surgery. At 3 months postoperatively, they had reverted to preoperative values. RNFL thickness change had no correlation with IOP change. Mean optic disc cup area decreased from 2.39±0.52 mm2 preoperatively to 2.14±0.52 mm2 at 1 week (P=0.022), 2.22±0.53 mm2 at 1 month (P=0.038), and 2.27±0.60 mm2 at 3 months (P=0.071). No significant change was found in other ONH parameters.

Conclusions

Short-term fluctuations were noted in RNFL thickness and ONH postoperatively following glaucoma filtration surgery. RNFL thickness temporarily increased and cup area decreased but the values reverted to normal within 3 months.  相似文献   

12.
Purpose: To investigate the effects of central corneal thickness (CCT) on intraocular pressure (IOP) measurements of the Pascal dynamic contour tonometry (DCT), Canon TX‐10 non‐contact tonometry (NCT) and Goldmann applanation tonometry measurements (GAT) in healthy subjects. Methods: IOP values of 135 eyes with normal corneas of 135 healthy volunteers were determined by DCT, NCT and by GAT. The CCT was measured using an ultrasonic pachymeter after all IOP determinations had been made. Results: When DCT measurements were compared (IOP = 17.52 ± 2.0 mmHg) with NCT measurements (IOP = 16.54 ± 2.77 mmHg) and GAT measurements (IOP = 15.07 ± 2.35 mmHg), DCT measurements were significantly higher than NCT and GAT (p < 0.001). There was a significant correlation between CCT with both NCT (r = 0.260, p = 0.003) and GAT measurements (r = 0.257, p = 0.005). There was a weak correlation that was not statistically significant between CCT and DCT (r = 0.160, p = 0.079). Conclusion: The IOP measurements with DCT seem to be less dependent on CCT. NCT appears to be more affected by variation in CCT than GAT.  相似文献   

13.

Aim

To verify the safety and efficacy of Ologen (OLO) implant as adjuvant compared with low-dosage mitomycin-C (MMC) in trabeculectomy.

Methods

This was a prospective randomized clinical trial with a 24-month follow-up. Forty glaucoma patients (40 eyes) were assigned to trabeculectomy with MMC or OLO. Primary outcome includes target IOP at ≤21, ≤17, and ≤15 mm Hg; complete (target IOP without medications), and qualified success (target IOP regardless of medications). Secondary outcomes include bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain optical coherence tomography (SD-OCT) examination; number of glaucoma medications; and frequency of postoperative adjunctive procedures and complications.

Results

The mean preoperative IOP was 26.5 (±5.2) in MMC and 27.3 (±6.0) in OLO eyes, without statistical significance. One-day postoperatively, the IOP dropped to 5.2 (±3.5) and 9.2 (±5.5) mm Hg, respectively (P=0.009). The IOP reduction was significant at end point in all groups (P=0.01), with a mean IOP of 16.0 (±2.9) and 16.5 (±2.1) mm Hg in MMC and OLO, respectively. The rates and Kaplan–Meier curves did not differ for both complete and qualified success at any target IOP. The bleb height in OLO group was higher than MMC one (P<0.05). SD-OCT analysis of successful/unsuccessful bleb in patients with or without complete success at IOP ≤17 mm Hg indicated a sensitivity of 83% and 73% and a specificity of 75% and 67%, respectively, for MMC and OLO groups. No adverse reaction to OLO was noted.

Conclusions

Our results suggest that OLO implant could be a new, safe, and effective alternative to MMC, with similar long-term success rate.  相似文献   

14.
Objective: To evaluate dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) intraocular pressure (IOP) measurements in eyes that underwent penetrating keratoplasty (PKP).Design: Prospective, cross-sectional, observational study.Participants: Thirty-one eyes of 28 patients were examined after PKP.Methods: All eyes had undergone PKP with interrupted sutures. The postoperative period was more than 1 year for 25 eyes and less than 1 year for 6. Sutures were removed based on corneal topography and refraction. IOP was measured by both DCT and GAT methods and was correlated to the number of remaining sutures.Results: IOP readings were successfully obtained in 25/31 (80.6%) with DTC and in 21/31 (67.7%) with GAT (p = 0.25). In eyes with fewer than 4 remaining sutures, both methods were successful. In eyes with more than 4 sutures, the success rates of DCT and GAT were 66.7% and 44.4%, respectively (p = 0.18). In PKPs with a postoperative period of more than 1 year, the success rates of DCT and GAT were 96% and 84%, respectively (p = 0.16). In 20 eyes, both methods measured the IOP. The mean IOP obtained by DCT (16.6 [SD 2.8] mm Hg) was higher than the mean IOP obtained from GAT (15.1 [SD 3.6] mm Hg). The IOPs from the 2 instruments correlated significantly (p < 0.05) and the mean difference was 1.5 mm Hg.Conclusions: The success rate in measuring IOP with DCT and GAT did not show any statistically significant difference. Both methods were less effective measuring the IOP after recent PKPs and regrafts. However, DCT seemed to be superior to GAT in corneas with more than 4 remaining sutures and in PKPs performed more than 1 year earlier. The absolute values of IOP were higher with DCT than with GAT.  相似文献   

15.

Purpose

To report outcomes of deep sclerectomy (DS) with intraoperative mitomycin C (MMC) application in eyes with previous failed glaucoma surgery (GS) and/or cataract extraction (CE).

Patients and methods

Single-surgeon case series of 82 eyes of 82 patients undergoing DS with MMC. The patients had previous CE with IOL and/or conjunctival GS and treated intraocular pressure (IOP) >18 mm Hg. MMC (0.2 mg/ml) was applied for 2–3 min before scleral flap dissection. Complete success was defined as IOP between 6 and 21 mm Hg or a reduction of 20% from baseline without medications. Reoperation for glaucoma or related complications, or loss of light perception vision was considered as failure.

Results

Mean follow-up was 57.7±22.4 months with 78% of patients completing the 3-year follow-up. Mean IOP decreased from 24.0 mm Hg (22.3–25.6, 95% confidence intervals) to 13.4 mm Hg (12.0–14.2) at 3 years after surgery (P<0.001). There was a significant decrease in the number of glaucoma medications from 2.0±1 preoperatively, to 0.3±0.7, 3 years after surgery. Kaplan–Meier cumulative success rates were 85.6% at 1 year, 80.0% at 2 years, and 76% at 3 years. At 3 years, IOP was maintained <19 and 15 mm Hg in 83 and 70% of eyes, respectively. Fourteen eyes (17.1%) had complications. Delayed hypotony (IOP <6 mm Hg) was the commonest complication in five eyes (6.1%).

Conclusion

DS with MMC appears to be a safe and effective surgical procedure for eyes with previous intraocular surgery.  相似文献   

16.

Purpose

The aim of this study was to investigate the incidence of intraocular pressure (IOP) elevation after resident-performed cataract surgery and to determine variables, which influence postoperative day 1 (POD1) IOP.

Methods

In all, 1111 consecutive cataract surgeries performed only by training residents between 1 July 2001 and 30 June 2006 were included. Elevated IOP was defined as ≥23 mm Hg. Surgeries were classified according to the presence of POD1-IOP elevation. Fisher''s exact test and Student t-test were used to compare both groups. Multivariate analyses using generalized estimating equations were performed to investigate predictor variables associated with POD1-IOP elevation.

Results

The average preoperative IOP was 16.0±3.2 mm Hg and the average POD1-IOP was 19.3±7.1 mm Hg, reflecting a significant increase in IOP (P<0.001, paired t-test). The incidence of POD1-IOP elevation ≥23 mm Hg was 22.0% (244/1111). Presence of glaucoma and ocular hypertension, higher preoperative IOP, and longer axial length were frequently encountered variables in the POD1-IOP elevation group (all P<0.05). Using a multivariate analysis, presence of glaucoma (P=0.004, OR=2.38; 95% confidence interval (95% CI)=1.31–4.30), presence of ocular hypertension (P=0.003, OR=6.09; 95% CI=1.81–20.47), higher preoperative IOP (P<0.001, OR=3.73; 95% CI=1.92–7.25), and longer axial length (P=0.01, OR=1.15; 95% CI=1.03–1.29) were significant predictive factors for POD1-IOP elevation.

Conclusions

IOP elevation on the first postoperative day following resident-performed cataract surgery occurred frequently (22.0%). Increased early postoperative IOP was associated with presence of glaucoma and ocular hypertension, higher preoperative IOP, and longer axial length.  相似文献   

17.
Purpose  To evaluate the effect of contact lens-induced corneal edema on intraocular pressure (IOP) measurements using Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) in Asian subjects. Participants  The study included 40 eyes of 20 normal volunteers with no evidence of ocular disease. Methods  Forty eyes of 20 healthy volunteers were required to wear soft contact lenses for 2 hours to induce corneal swelling. Central corneal thickness (CCT) and IOP were measured before and immediately after contact lens wear using specular microscope, GAT, and DCT. The IOP measurements by GAT and DCT were compared. The changes in the CCT and the IOP measurements after wearing contact lenses were assessed. Results  The mean CCT of the 40 eyes evaluated was 532.6 ± 31.6 μm. The mean IOP was 11.78 ± 2.04 mmHg for the GAT and 14.46 ± 1.89 mmHg for the DCT, and the difference was statistically significant (P < 0.001). After wearing contact lenses, the mean CCT was 553.2 ± 34.3 μm, which was 20.6 ± 12.9 μm greater than before wearing them (P < 0.001). The mean IOP measurements of the GAT and DCT were decreased after wearing the contact lenses. The mean decrease of the GAT values was 0.43 ± 1.95 mmHg, which was not statistically significant (P = 0.175). However, the mean decrease of the DCT readings, which was 0.75 ± 1.74 mm Hg, was statistically significant (P = 0.010). Conclusion  The IOP measurements with DCT were significantly higher than those with GAT in healthy Asian eyes. Although the mean IOP measurements of both the GAT and the DCT were decreased in the edematous cornea, IOP measurements of the DCT were more affected by corneal edema than were the GAT. The authors have no proprietary, commercial, or financial interests in any of the products described in this study.  相似文献   

18.
AIM: To analyze the correlation of Goldmann applanation tonometer (GAT), I-Care tonometer and Tono-Pen tonometer results in young healthy persons, and to investigate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements recorded with these tonometers. METHODS: We conducted a pilot clinical study in 78 eyes of 78 subjects aged 22-28 years old (44 women and 34 men; mean age 23.8±1.19y). IOP was measured using GAT, I-Care and Tono-Pen tonometers, followed by measurements of CCT. Statistical analysis was performed using SPSS 20.0. RESULTS: The mean IOPs and standard deviation (±SD) for GAT, I-Care and Tono-Pen were 15.62±2.281 mm Hg, 16.29±2.726 mm Hg and 16.32±2.393 mm Hg, respectively. The mean CCT was 555.15±29.648 μm. Clear positive correlations between GAT and I-Care, GAT and Tono-Pen, and I-Care and Tono-Pen tonometers were found (r=0.867, P<0.001; r=0.861, P<0.001; r=0.915, P<0.001, respectively). In comparison between devices, Bland–Altman analysis showed a significant mean difference (MD) in the measurements by GAT and I-Care of ?0.679 mm Hg and by GAT and Tono-Pen of ?0.705 mm Hg ( P<0.001), but there was no significant difference between I-Care and Tono-Pen ( P>0.05). Both non-gold standard tonometers were affected by CCT; that is, both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means (>555 μm; MD=?1.282, P<0.001; MD=?0.949, P<0.001, respectively) compared with GAT. CONCLUSION: Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values. Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results. Higher CCT values (>555 μm) were associated with overestimated IOP values.  相似文献   

19.

Purpose

To compare the intraocular pressure (IOP) after 23-gauge transconjunctival sutureless vitrectomy (TSV) and conventional 20-gauge vitrectomy for various vitreoretinal diseases.

Methods

This was a retrospective interventional case series including 338 cases of 23-gauge TSV and 476 cases of 20-gauge vitrectomy with minimum follow-up period of 1 month. Postoperative 1 day, 1 week and 1 month IOPs were compared. Multiple regression analysis to assess the actual effect of gauge of vitrectomy on postoperative IOP was performed including intraoperative and postoperative factors influencing postoperative IOP as covariates.

Results

The mean IOP of 20-gauge vitrectomy was significantly higher than that of 23-gauge TSV (20.6±8.02 mm Hg vs12.8±4.48 mm Hg, P<0.001) at postoperative day 1, but the differences were not significant at postoperative 1 week and 1 month. The IOP pattern of 23-gauge TSV demonstrated more stable course than that of 20-gauge vitrectomy. At 1 day post vitrectomy, the incidence of hypertony was higher in 20-gauge, whereas that of hypotony was higher in 23-gauge. Among risk factors, the 20-gauge vitrectomy showed the strongest association with postoperative 1 day IOP rise.

Conclusion

Twenty-three-gauge TSV has stable and lower IOP in the early postoperative period than the 20-gauge vitrectomy. In patients whose retina and optic nerves are vulnerable to higher or fluctuating IOP, 23-gauge TSV may be more beneficial.  相似文献   

20.

Aim

The aim of this study is to compare the 24-hour efficacy of dorzolamide/timolol-fixed combination (DTFC) and brimonidine/timolol-fixed combination (BTFC) in primary open-angle glaucoma (POAG).

Methods

One eye each of 77 POAG patients was included in this prospective, observer-masked, crossover comparison. Following a 2-month timolol run-in period, patients had three intraocular pressure (IOP) measurements at 1000, 1200 and 1400 h while on timolol treatment. Patients showing at least a 20% IOP reduction on timolol were randomised to 3 months of therapy with DTFC or BTFC, and then were crossed over to the opposite therapy.

Results

Sixty POAG patients completed the study. The mean 24-hour IOP was significantly reduced with both the fixed combinations compared with the timolol-treated diurnal IOP (P<0.001). When the two fixed combinations were compared directly, DTFC demonstrated a lower mean 24-hour IOP level as compared with BTFC (mean difference: −0.7 mm Hg, 95% confidence interval (CI): (−1.0, −0.3), P<0.001). At two individual time points, DTFC significantly reduced IOP more than BTFC: at 1800 h (−1.0 mm Hg, 95% CI (−1.6,−0.5), P=0.001) and at 0200 (−0.9 mm Hg, 95% CI: (−1.4,−0.5), P=0.001). No significant difference existed for the other time points.

Conclusion

Both the fixed combinations significantly reduce 24-hour IOP in POAG. DTFC provided significantly better 24-hour efficacy.  相似文献   