首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 92 毫秒
1.
The concentrations of 137Cs and 134Cs in Malaysian marine sediments were measured by gamma-ray spectrometry with a high-purity germanium (HPGe) detector connected to a multichannel analyzer. In general, the 137Cs concentration in Malaysian marine sediments has been found to be very low and less than 5 Bq/kg dry weight with the exception of those from a few sampling locations. The concentration of 134Cs was found to be less than the minimum detectable activity for the measuring condition used. Data reported in this paper were found to be comparable with results from within the region and thus can be used as reference data for the country.  相似文献   

2.
3.
The specific radioactivities of the U-series, 232Th, 137Cs and 40K were measured in soil samples around the Inshass reactor in Cairo, using a γ-ray spectrometer with a HpGe detector. The -activity of 238U, 234U and 235U was measured in the same soil samples by surface barrier detectors after radiochemical separation and the obtained results were compared with the specific activities determined by γ-measurements. The -activity of 238Pu, 239+240Pu, 241Am, 242Cm and 244Cm was measured after radiochemical separation by surface barrier detectors for both soil and plant samples. Then β-activity of 241Pu was measured using liquid scintillation spectrometry.  相似文献   

4.
Using a high-resolution gamma-spectrometer system, the activity concentrations of 7Be, 137Cs, 40K and 226Ra were determined in the pine needles. Activity concentrations of the concerned radionuclides in the needle samples were as follows: 7Be, 24.6±2.40 to 210±7.21 Bq kg−1, 40K, 23.5±12.4 to 287±15.6 Bq kg−1, 226Ra, 0.44±0.12 to 12.3±2.18 Bq kg−1, and 137Cs, 0.61±0.30 to 2.29±0.38 Bq kg−1. It is found that the frequency distributions obtained for 7Be and 137Cs can be fitted to a normal distribution, and for 40K and 226Ra can be fitted to a log-normal distribution.  相似文献   

5.
The accumulation of radionuclides in Black Sea marine ecosystems was investigated by low level gamma spectrometry. Artificial as well as natural radionuclides were determined in bottom sediments samples from 35 reference locations along the Bulgarian Black Sea coast, evenly distributed from the Rumanian to the Turkish border including the main Black Sea resorts and rivers. The measurement of radionuclides in sea bed sediments was carried out during six consecutive seasons using a HPGe detector. The data obtained show that the nuclide concentrations depend strongly on the sediment nature. Results for sandy sediments are within close range, while those for slime and silt vary to a much greater extent. The radionuclide content in the sandy sediments of the main Black Sea resorts is at the lowest limit of the determined values. Small seasonal changes of radionuclide concentration in sandy sediments were observed while greater variations in slime and silt occur. From the data obtained 134Cs/137Cs and 137Csmeas/137CsChern ratios are calculated to determine the Chernobyl part of the measured 137Cs. The activities determined in the sediments for natural radionuclides correspond to those cited in the literature for natural levels, showing no additional anthropogenic contamination. A data base for the nuclide concentration values was created which will enable the modeling of radionuclide transfers by estimation of their concentration variations, accumulation and influence on the marine ecosystems.  相似文献   

6.
The linear and mass attenuation coefficients of different types of soil, sand, building materials and heavy beach mineral samples from the Chittagong and Cox's Bazar area of Bangladesh were measured using a high-resolution HPGe detector and the γ-ray energies 276.1, 302.8, 356.0, 383.8, 661.6 and 1173.2 and 1332.5 keV emitted from point sources of 133Ba, 137Cs and 60Co, respectively. The linear attenuation coefficients show a linear relationship with the corresponding densities of the samples studied. The variations of the mass attenuation coefficient with γ-ray energy were exponential in nature. The measured mass attenuation coefficient values were compared with measurements made in other countries for similar kinds of materials. The values are in good agreement with each other in most cases.  相似文献   

7.
The concentrations and distribution of natural and anthropogenic radioactive materials in sediments and soils from around the two major rivers and coastal area of Chittagong, Bangladesh were investigated with an aim of evaluating the environmental radioactivity and radiation hazard. In the sediment and soils in general, the concentration of 232Th was found to be higher than that of the 238U and the activities of 232Th and 238U in this area are higher than the world average. 137Cs was observed in all the samples, ranging from 0.4 to 3.88 Bq kg−1. The radium equivalent activities, emanation coefficients and radon exhalation rates were estimated for the sediment and soils; the emanation coefficients, radon exhalation rates and dose rates were found to be higher than the world average values.  相似文献   

8.
In low-level gamma-ray spectrometry, it is common to measure large samples in order to obtain low detection limits for the massic activity (in mBq/kg). These samples have significant shielding effects. In order to study whether the background sources in three ultra low-background HPGe detectors were located in the detector or in the shield, Marinelli beakers filled with hyperpure mercury were measured. Although the measurements were hampered by the presence of cosmogenically produced 194Hg, information regarding the major background location of 40K, 60Co, 137Cs, 210Pb, 226Ra, 228Ra and 228Th could be obtained.  相似文献   

9.
After the end of atmospheric nuclear weapons tests and after the Chernobyl accident, the deposition characteristics of 137Cs changed from a predominant wet deposition to the present resuspension mechanism characterised by predominant dry deposition. To study the consequences of this change for deposition sampling, monthly deposition data from two collectors located at a distance of 600 m were compared from 1991 to 2000. On the average, the deposition rates differed by roughly a factor of two for 137Cs, whereas for the cosmogenic 7Be a difference was not detectable with statistical significance. Further, a “funnel” collector with a mostly dry surface collected on the long-term average 36% less of 137Cs, but 8% less of 7Be, than a “pot” collector with a continuously water-covered surface. Since for 137Cs deposition and the bulk deposition a similar behaviour was found, a stronger sensitivity of other resuspension-derived radionuclides against local and collector surface variations can generally be expected.  相似文献   

10.
β-Ray spectra after penetrating absorbing materials of various thicknesses were observed by the use of a scintillation-type β-ray spectrometer equipped with a flat NE-102 plastic scintillator of 5 mm thickness for sources of 60Co, 90Sr–90Y, 137Cs, 147Pm and 204Tl. Although the spectra changed rapidly with increasing absorber thickness, the average β-ray energy was kept nearly constant for a wider range. These results are consistent in that the β-ray absorption curve becomes quasi-linear in a semi-logarithmic plot. Spectra including scattered β-rays from several materials placed behind the source were also measured for 137Cs and 204Tl. It may be concluded that mean energy measurements by the use of β-ray spectrometer of this kind is useful for the identification of nuclides in radiation protection purposes even in worse source-conditions.  相似文献   

11.
A stockpile probe based on backscattered gamma–gamma-ray technique was tested for the determination of coal ash. A centralized tool employing a gamma-ray source of very low radioactivity (1.85 MBq) was used. This logging tool was tested using 137Cs and 133Ba sources with a 37 mm (diameter) by 75 mm NaI (TI) scintillation detector. Ten source–detector configurations were analyzed using 137Cs, and another nine source–detector configurations are analyzed, using 133Ba source, both for four geophysical models, having a borehole diameter of 90 mm. Regression analysis on the laboratory logging data for each studied configuration was carried out in order to establish calibration equations for ash prediction. The optimum configuration for the logging stockpile probe using 137Cs source was determined to be 80 mm source to detector spacing, and 80 mm iron thickness shielding. This configuration gives the best results for ash prediction. The root mean square (rms) deviation for ash is 1.52%. The optimum configuration for the logging stockpile probe using 133Ba source is determined to be 85 mm source to detector spacing, and 50 mm iron thickness shielding. This configuration gives the best results for ash prediction, where the rms deviation for ash is 1.47%.  相似文献   

12.
 Most commercial nuclear density gauges use either 137Cs or 60Co sources of activity between about 185 and 1850 MBq (5 and 50 mCi). In the current work, density and thickness gauges that use ultra-low activity gamma-ray sources that are exempt from licensing requirements have been investigated. Results are reported on gauges that use a 1 MBq 22Na source for determining slurry density in the CSIRO UltraPS slurry particle size analyser and for determining belt loading in the CSIRO on-conveyor belt microwave moisture gauge.  相似文献   

13.
A theoretical method of determining the gamma-ray peak efficiency for a cylindrical source, based on a modified expression for point sources is derived. A term for the photon self-attenuation is included in the calculation. The method is valid for any source material as long as the source activity concentration is considered to be homogeneous. Results of this expression are checked against experimental data obtained with 241Am, 57Co, 137Cs, and 60Co sources.  相似文献   

14.
The paper presents the results obtained at IFIN-HH during a metrological certification of the commercially available radionuclide calibrator, the CURIEMENTOR2. Its performance was tested for the radionuclides: 57Co, 99mTc, 131I and 137Cs. The calibration factors determined by the manufacturer and those obtained at IFIN-HH differed by less than 3.5%. New calibration factors were determined for 60Co and 188Re, which have, until now, not been distributed by the manufacturer to the users. Furthermore, the linearity of instrument response and the dependence of measuring geometry were checked and found in accordance with the international accepted standards and legal requirements.  相似文献   

15.
We compared the value of using a digital signal processing unit for gamma-ray spectroscopy with that of an analog one for in situ measurements of gamma-rays generated by inelastic neutron scattering reactions with soil elements. A large cylindrical NaI(Tl) scintillation detector, 15.24 cm high by 15.24 cm diameter was used to measure carbon (C) and oxygen (O). The performance of the systems was assessed as a function of input count rate (ICR) by monitoring the peak areas of the C, 4.43 MeV, and O, 6.13 MeV, gamma-rays. In separate experiments, the digital and the analog systems were also compared using an intense 10.3 mCi 137Cs source to vary the ICR, and the 1.17 MeV peak area of 60Co was used as the reference.  相似文献   

16.
For more than 15 years, European Union (EU) laboratories monitoring environmental radioactivity have been obliged to participate in measurement comparisons organised by the European Commission. After a short review of comparisons conducted during the 1990s, the approach of IRMM organising these comparisons since 2003 is presented. It relies on the provision of comparison samples with reference values traceable to the International Reference System for radionuclides (SIR). The results of the most recent comparison, the determination of 40K, 90Sr and 137Cs in milk powder, are presented. The influence of repetitive participation in measurement comparisons on laboratory performance is studied on the basis of data from more than 20 laboratories having participated in several exercises during the last 15 years.  相似文献   

17.
Effective cross-sections for the production of 127Cs in the bombardment of natXe with protons were measured from threshold up to 100 MeV. From the integral excitation function obtained, yield curves for 127Xe, produced via the natXe(p,xn)127Cs → 127Xe route, were derived for a full range of gas target thicknesses. These curves can be used for the optimization of the production of 127Xe within specific practical incident energy and target thickness constraints. The expected optimum yield for a representative production gas target (1.64 g/cm2 thick) is 6.7 MBq/μAh (obtained at an incident energy of 39.3 MeV).  相似文献   

18.
Using the 165.9-keV M1 transition in 139La as a calibrant, we have determined the K-shell internal conversion coefficients (ICCs) for the 127.5-keV E3 transition in 134Cs and the 661.7-keV M4 transition in 137Ba to 0.6% precision. Unlike previous less-precise measurements of these ICCs, which differed significantly from calculated values, our results agree well with calculations that include the atomic K-shell vacancy and disagree with those that exclude it. These results, which are consistent with what we also found for 193Ir, confirm our earlier conclusions but for different energies, multipolarities and atomic numbers.  相似文献   

19.
A new technique for processing airborne gamma ray spectrometry data has been developed. It is based on the noise adjusted singular value decomposition method introduced by Hovgaard in 1997. The new technique opens for mapping of very low contamination levels. It is tested with data from Latvia where the remaining contamination from the 1986 Chernobyl accident together with fallout from the atmospheric nuclear weapon tests includes 137Cs at levels often well below 1 kBq/m2 equivalent surface contamination. The limiting factors for obtaining reliable results are radon in the air, spectrum stability and accurate altitude measurements.  相似文献   

20.
A commercially available radionuclide calibrator of the type Curiementor 3 (PTW, Freiburg, Germany) was calibrated using activity standard solutions, from the Physikalisch-Technische Bundesanstalt (PTB), of a number of photon-emitting radionuclides, in particular those used in nuclear medicine: 18F, 51Cr, 67Ga, 99mTc, 111In, 123I, 125I, 131I, 186Re, 201Tl, and for beta-emitting nuclides: 32P, 89Sr, 90Y, 204Tl. An energy-dependent efficiency curve was established to calculate efficiencies for photon-emitting radionuclides. The differences between experimental and calculated radionuclide efficiencies of the measuring system are of the order of a few percent. The performance of the system was checked for instrument stability, using a long-lived 137Cs source, and for linearity using the decay of a 99mTc source. The calibration measurements were carried out with 2 g of solution in standard PTB-type glass ampoules. The dependence of efficiency with varying solution mass and changing ampoule geometry is studied for some of the radionuclides. For example, geometry correction factors are determined for various solution volumes or ampoules with different wall thickness. The measuring system will enable the National Centre of Metrology (NCM) of Bulgaria to provide calibration services for activity measurements, which are traceable to PTB standards, and to organize national comparisons in order to improve the quality of measurements for nuclear medicine in Bulgarian hospitals. Furthermore, it should enable NCM to declare Calibration and Measurement Capabilities (CMCs) and to submit radioactive solutions to the International Reference System (SIR) at the BIPM in order to compare the results with Key Comparison Reference Values (KCRVs).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号