首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 79 毫秒
1.
Purpose. The most frequent and troublesome complication after resection of an emphysematous lung is persistent air leakage. This report describes our recent experience of using sleeves made of polyglycolic acid to reinforce staple-lines to reduce air leaks after resection of emphysematous lung. Methods. We used bioabsorbable sleeves made of polyglycolic acid (PGA) for staple-line reinforcement during lung resections in 25 patients with emphysema. Results. Immediately after stapling, no air leaks were detected in 20 patients (80%), although prolonged air leaks lasting for more than 7 days were observed in three patients (12.5%). Conclusion. PGA sleeves do not constitute a foreign body that stays in the host lung, and they require no rinsing at the time of clinical use. Therefore, the PGA sleeve could be a promising new material instead of non-absorbable materials and xenomaterials for staple-line reinforcement. Received: October 10, 2000 / Accepted: November 20, 2001  相似文献   

2.
Although various materials have been used for reinforcement in lung-volume-reduction surgery to buttress pulmonary staple-line, absorbable materials are not available for use in thoracoscopic surgery. Moreover, even nonabsorbable types of reinforcements have been used only for lung volume reduction surgery. However, elderly patients with spontaneous pneumothorax secondary to emphysematous lung are well treated with staple-line reinforcement. The authors developed a new type of polyglycolic acid felt to buttress staple-line. This felt is absorbable, easier to cut with a stapler knife than is the conventional polyglycolic acid felt, and inexpensive enough to use for various types of thoracic surgeries for emphysematous lungs in Japan, and it can be attached to staplers with a small amount of fibrin glue. These strips were used to reinforce pulmonary staple lines for resection of emphysematous lungs in 14 patients: pulmonary emphysema (n = 1), bilateral giant bullae (n = 1), ipsilateral giant bullae (n = 6), spontaneous pneumothorax with multiple bullae in an emphysematous lung (n = 5), and lung cancer in a patient with pulmonary emphysema (n = 1). There were no air leaks during surgery. Air leaks were noted in three patients after surgery. In two patients, the air leaks stopped within 2 weeks. In one patient, the air leak was found to originate from an untouched lobe during reoperation. No infection or allergic reaction developed in a patient during a mean follow-up of 12 months (range, 1 to 24 months).  相似文献   

3.
Bioabsorbable Seamguard (BSG) is a random-fiber web of polyglycolic acid/trimethylene carbonate. It is completely absorbed within 6 months or less due to its constitution of a bioabsorbable membrane with polyester braided suture. It has been used in obesity surgery and pulmonary surgery as staple-line reinforcement with good results. As such, we believe that BSG may be ideal to use in colorectal surgery as an aid during the healing process of an anastomosis and may help prevent anastomotic bleeding and staple-line disruption. From July 2003 through September 2004, 30 patients underwent placement of BSG for the following procedures: 12 right hemicolectomies, 7 low anterior resections, 5 sigmoid colectomies, 3 total colectomies, 2 partial resections, and 1 colostomy closure. Median follow-up was 7 months (range 1-13). There were no clinical leaks, no strictures, and no bleeding in our early postoperative follow-up period. The use of BSG as a staple-line reinforcer appears to be safe and may be useful in preventing anastomotic leakage, bleeding, and intraluminal stenosis.  相似文献   

4.
OBJECTIVE: Persistent air leakage following pulmonary resection is a major limiting factor for discharge from hospital. The aim of this study was to evaluate the sealing capacity of TachoSil for the closure of alveolar air leaks following parenchymal resections and to determine its effect on time to chest drain removal and duration of hospitalisation. Methods: A total of 173 patients undergoing lobectomy or segmentectomy were enrolled in a single-centre, randomised study to compare the efficacy of TachoSil with standard treatment. Alveolar air leaks were evaluated intraoperatively by submersion of the resection site in saline and were graded according to the Macchiarini scale as 0 (no bubbles), 1 (single bubbles), 2 (stream of bubbles), 3 (coalescent bubbles). Patients with grade 1 or 2 air leaks were randomised to TachoSil or standard treatment. Grade 3 patients received standard treatment until the air leak was downgraded to grade 1 or 2 at which point they were randomised. Patients with grade 0 leakage were excluded. The primary efficacy endpoints of the study were postoperative quantification of air leakage on postoperative days 1 and 2. Other efficacy measurements included mean time to chest drain removal and mean time to hospital discharge. Results: The mean intraoperative post-treatment air leakage was significantly lower in the TachoSil group (153.32ml/min, range: 10-450ml/min) compared with the standard treatment group (251.04ml/min, range: 15-970ml/min; P=0.009). The significant difference in air leakage volume observed intraoperatively post-treatment was maintained postoperatively. TachoSil showed a trend towards reduced incidence of postoperative leakage when measured >48h or >7 days after surgery (30.7% vs 38.96% and 24% vs 32.46%, respectively). The mean times to chest drain removal and to hospital discharge were significantly reduced following the use of TachoSil (5.1 days vs 6.3 days, P=0.022 and 6.2 days vs 7.7 days, P=0.01, respectively). Conclusions: The use of TachoSil following pulmonary resection resulted in a reduction in air leakage compared with standard techniques. This reduction in air leakage resulted in a significant reduction in both the time to chest drain removal and the period of hospitalisation.  相似文献   

5.
PURPOSE: In a thoracoscopic surgery for the patient with spontaneous pneumothorax, an air-leakage from the staple-line is one of the most troublesome complications. Recently we have been using a polyglycolic acid (PGA) sleeve for staple-line reinforcement. The purpose of this study was to investigate an efficacy of staple-line reinforcement in the patients who underwent thoracoscopic lung resection using an automatic stapler. OBJECTS: Last 4 years, 55 patients with primary spontaneous pneumothorax underwent thoracoscopic surgery using an automatic stapler. PGA sleeve was used in 19 patients as PGA group, fibrin glue was applied to the staple-line in 6 patients as fibrin group and no staple-line reinforcement was applied in 30 patients as no-reinforce group. We investigated the efficacy of staple-line reinforcement according to the results after surgery in these 3 groups. RESULTS: Average drainage time in PGA group, fibrin group and no-reinforce group were 2.1, 2.2 and 2.8 days, respectively. In PGA group, the drainage time after surgery tended to be short term. The relapse of pneumothorax after surgery developed in 2 patients in PGA group (10.5%) and 8 patients in non-reinforce group (26.7%). In PGA group, the relapse after surgery tended to be low rate. CONCLUSIONS: Bioabsorbable PGA sleeve could be an useful device for a staple-line reinforcement in the patients who underwent lung resection using automatic stapler.  相似文献   

6.
The purpose of this randomized trail was to investigate the effect of using a pedicled pericardial fat pad fixed with fibrin glue on postoperative alveolar air leakage. Thirty consecutive patients with lung cancer, who had moderate alveolar air leaks after pulmonary resection, were randomized into two groups: in group A fibrin glue was applied onto the surface of the leaking raw lung and in group B, after applying fibrin glue in the same manner as in group A, a pedicled pericardial fat pad was immediately fixed to the leaking lung surface with fibrin glue. The duration of the postoperative air leakage and chest tube drainage was recorded. In 6 of 15 patients in group B the air leakage ceased within the first 24 h after pulmonary resection, while in group A only 1 of 15 patients showed a cessation of the air leakage, and a significant difference was noticed between the two groups (P = 0.0309). The duration of the postoperative air leakage was 4.8 ± 4.6 days in group A and 3.6 ± 3.4 days in group B. The pedicled pericardial fat pad fixed onto the surface of the leaking raw lung using fibrin glue was found to reduce alveolar air leakage after pulmonary resection. Received: January 11, 2001 / Accepted: September 11, 2001  相似文献   

7.
Objective: Advances in video-assisted thoracic surgical (VATS) technique led the authors to reconsider the treatment and thoracoscopic management of patients with giant bullous emphysema (GBE). Methods: From January 1993 to December 2001 we treated 40 patients with unilateral GBE: 24 males and 16 females, mean age 51±1 years. Thirty patients presented respiratory insufficiency, seven patients a spontaneous pneumothorax and three patients a bullae infection. Excision was performed by using Nd:YAG laser in five patients (12.5%) and stapling device in 35 patients (87.5%). Among the last 35, in 20 patients a partial pleurectomy stripping up to the 5th intercostal space was associated. In 15 patients this technique was modified through the systematic application of polytetrafluoroethylene (PTFE) to reinforce stitches. Results: We experienced one conversion to open thoracotomy owing to haemorrhaging, in one patient who underwent a partial pleurectomy stripping. In the stapler resection patients, with PTFE application, the mean duration of air leaks, for type 1 bullae of Wakabayashi was 2.2±1.8 days and, for type 4, 5.9±1.4 days; the mean length of hospital stay was 6.1±0.5 days. Conclusions: The resection in VATS of giant bullous emphysema by stapling device associated to reinforcement in PTFE reduces duration of air leaks and hospitalisation and improves pulmonary function.  相似文献   

8.
Background: The optimal surgical management of primary spontaneous pneumothorax (PSP) is still controversial, especially in terms of the technique to be used. The aim of this paper was to report our experience of videothoracoscopic silver nitrate pleurodesis (VATSNP). Methods: Between 1995 and 2004, all the medical records of the patients who had undergone silver nitrate videothoracoscopic pleurodesis (SNVTP) were reviewed. All the patients had systematic prospective clinical and radiological follow-up at 1 month. The last 250 patients were retrospectively recontacted for long-term follow-up. Results: Six hundred and three patients underwent SNVP. No intra-operative death or major complication occurred during or after the procedures. Mean operating time was 40.2 ± 10.7 min. The conversion to thoracotomy rate was 2.5%. Main postoperative complications were prolonged air leak (15.6%), partial residual pneumothorax (5.1%), pleural effusion (2.5%) and postoperative bleeding (2.0%). The follow-up was 100% complete 1 month after discharge; at 1 month, the recurrence rate was 0.5%. The last 250 patients were retrospectively recontacted with a mean follow-up of 2.9 ± 2.3 years (184 patients). The long-term recurrence rate was 1.1%. Conclusions: It is one of the first reports on the use of video-assisted thoracoscopic silver nitrate pleurodesis for PSP. We demonstrate safety and effectiveness of the procedure with long-term results comparable with standard open pleural abrasion or pleurectomy.  相似文献   

9.
PURPOSE: Pulmonary injury with resultant air leak is common at cardiac reoperation. Sequelae of this complication include prolonged chest tube drainage and time to ambulation, extended hospitalization and increased costs, and mediastinitis. The purpose of this study was to test the efficacy of a new synthetic absorbable sealant at treatment air leaks occurring at cardiac reoperation. PATIENTS AND METHODS: Fifteen patients having cardiac reoperation had lung injuries repaired with FocalSeal-L Sealant (Focal, Inc., Lexington, MA). Mean age was 61+/-15 years, and mean interval from the previous to the current operation was 44+/-38 months. RESULTS: In all patients, FocalSeal-L Sealant was successful at sealing intraoperative air leaks. Postoperatively, 73% of patients had no air leak. Four patients (27%) developed a recurrent air leak, three on postoperative day 1 and one on postoperative day 2. In three of these patients, the air leak sealed within 3 days. In the fourth patient, an immunosuppressed heart transplant recipient with mediastinitis, the air leak never sealed; that patient died of sepsis after an omental flap failed to control the air leak. In patients without air leak, chest tubes were removed on postoperative day 1 (9 patients) or 2 (1 patient). CONCLUSION: This novel synthetic sealant prevents postoperative air leaks in the majority of patients suffering lung injury at cardiac reoperation.  相似文献   

10.
Background Thoracoscopic simple bullectomy for primary spontaneous pneumothorax (PSP) has a relatively high postoperative recurrence rate and sometimes results in postoperative air leakage. One of the reasons for postoperative recurrence is the regrowth of bullae around the staple line. Therefore, reinforcement of the visceral pleura around the staple line is a reasonable way to prevent postoperative air leaks and recurrence. This study was done to determine the efficacy in preventing postoperative air leak and recurrent pneumothorax of widely covering the staple line with absorbable mesh after thoracoscopic bullectomy.Methods Wide coverage of the staple line with absorbable mesh was performed on 114 patients with PSP. These patients were retrospectively compared with 126 patients who underwent thoracoscopic simple bullectomy alone.Results The postoperative duration of chest drainage in the coverage group (mean, 1 day; range, 0–5) was significantly shorter than that in the simple bullectomy group (mean, 3 days; range 0–20). A prolonged air leak (>7 days) occurred in six patients in the simple bullectomy group, but there were no such leaks in the coverage group. Recurrent pneumothorax occurred in three patients (2.6%) in the coverage group and 12 patients (9.5%) in the simple bullectomy group.Conclusion Wide coverage of the staple line with absorbable mesh is effective in preventing postoperative air leak and in decreasing the recurrence rates of PSP.  相似文献   

11.
We investigated the comparative effectiveness of the seat and glue types of fibrin adhesive, to clarify which is more useful in preventing postoperative parenchymal air leaks after lung resection. One hundred sixteen patients received fibrin adhesive to prevent postoperative air leakage after lung resection carried out by the same surgeon. Ninety-two lobectomies and 24 partial resections were assessed. There were 29 patients with emphysematous lung. In the seat type group, an average of 2.6 postoperative days elapsed before chest drain removal. In the glue type, this average was 3.2 days, a significant difference. This difference was also evident in the lobectomy group. However, among emphysematous lung patients and the partial resection group, there was no apparent difference. Prolonged air leakage was seen in 2 patients with emphysematous lung, but no difference in terms of drug formation could be seen. The seated type of fibrin adhesive was more useful than the glue type in preventing postoperative air leaks, but in emphysematous lung patients, better surgical technique would seem to be the critical factor.  相似文献   

12.
BACKGROUND: Postoperative air leaks are a major cause of morbidity after lung resections. This study was designed to evaluate the efficacy and safety of a new synthetic, bioresorbable surgical sealant in preventing air leaks after pulmonary resection. METHODS: In a multicenter trial, 172 patients undergoing thoracotomy were randomized intraoperatively in a 2:1 ratio to receive surgical sealant applied to sites at risk for air leak after standard methods of lung closure (treatment group) or to have standard lung closure only (control group). The primary outcome variable was the percentage of patients free of air leakage throughout hospitalization. Secondary outcome variables were the control of air leaks intraoperatively and the time to postoperative air leak cessation. Time to chest tube removal, time to hospital discharge, and safety outcomes were also evaluated. RESULTS: Air leaks were identified before randomization in 89 of 117 patients in the treatment group and in 39 of 55 patients in the control group. Application of the sealant resulted in control of air leaks in 92% of treated patients (p < or = 0.001). A significantly higher percentage of treated patients than control patients remained free of air leaks during hospitalization (39% versus 11%, p < or =0.001). The mean times to last observable air leak were 30.9 hours in the treatment group and 52.3 hours in the control group (p = 0.006). In the treatment group, trends were observed for reduced time to chest tube removal and earlier discharge. No significant difference was identified in postoperative morbidity and mortality between the two groups. CONCLUSIONS: Air leaks after lung resection occur in most patients. The application of this novel surgical sealant appears to be effective and safe in preventing postoperative air leaks.  相似文献   

13.
HYPOTHESIS: The use of staple-line reinforcement sleeves during laparoscopic gastric bypass reduces staple-line bleeding, which may translate into a reduction in the rate of gastrointestinal hemorrhage. DESIGN: Prospective randomized trial. SETTING: University hospital. PATIENTS AND INTERVENTIONS: Thirty-four patients undergoing laparoscopic gastric bypass were randomly assigned to receive either no reinforcement (control group, n = 17) or reinforcement of the staple line with glycolic copolymer sleeves (treatment group, n = 17). MAIN OUTCOME MEASURES: Demographic data, the number of stapler loads used, the number of staple-line bleeding sites, the amount of blood loss, the length of time required to obtain hemostasis of the staple lines, operative time, intraoperative and postoperative complications, and serial hemoglobin levels. RESULTS: The mean number of stapler loads used was similar between groups. The mean number of staple-line bleeding sites was significantly fewer in the treatment group for division of gastric tissue (0.4 vs 2.5 bleeding sites), jejunal tissue (0.1 vs 0.6 bleeding site), and mesenteric tissue (0 vs 0.8 bleeding site). The mean blood loss was lower in the treatment group (84 vs 129 mL). Staple misfire occurred in 1 (0.7%) of 143 stapler loads used in the treatment group compared with 0 (0%) of 138 stapler loads used in the control group. The time to obtain staple-line hemostasis was shorter in the treatment group (1.2 vs 10.1 minutes). The total operative time was similar between groups. There was no mortality or postoperative leaks. One patient in the control group had postoperative gastrointestinal hemorrhage requiring blood transfusion and reoperation. There was no significant difference in the mean hemoglobin level between groups on the first postoperative day. CONCLUSIONS: The use of glycolide copolymer staple-line reinforcement sleeves in patients undergoing laparoscopic gastric bypass is safe and significantly reduces staple-line bleeding sites and may reduce the incidence of gastrointestinal hemorrhage.  相似文献   

14.
BACKGROUND: The object of this study was to assess the efficay and maximum duration of effect of the pleural tent in reducing the incidence of air leak after upper lobectomy. METHODS: Two hundred patients who underwent upper lobectomy were prospectively randomized into two groups: 100 patients who underwent an upper lobectomy and a pleural tent procedure (group 1; tented patients) and 100 patients who underwent only an upper lobectomy and not a pleural tent procedure (group 2; untented patients). The preoperative, operative, and postoperative characteristics of both groups were compared. Then multivariate analyses were used to identify factors predictive of prolonged air leaks and their duration. The reduction of incidences of air leak in the two groups was subsequently compared during successive postoperative periods. RESULTS: No differences were detected between the two groups in terms of preoperative and operative characteristics. A significant reduction occurred in group 1 patients for the mean duration of air leak in days (2.5 vs 7.2 days; p < 0001), the number of days a chest tube was required (7.0 vs 11.2 days; p < 0.0001), the length of postoperative hospital stay in days (8.2 vs 11.6 days; p < 0.0001), and the hospital stay cost per patient (4,110 dollars vs 5,805 dollars; p < 0.0001). Logistic regression analyses showed that not having undergone a pleural tent procedure was the most significant predictive factor of the occurrence and duration of prolonged air leaks. A greater reduction in the duration of air leaks was observed before postoperative day 4 in group 1, and logistic regression analysis showed that having undergone a pleural tent procedure was the most significant predictive factor of air leaks that persisted for less than 4 days. CONCLUSIONS: Pleural tenting after upper lobectomy was a safe procedure that reduced the duration of air leaks and the hospital stay costs. The benefit from that procedure was achieved before postoperative day 4.  相似文献   

15.
Dusick JR  Mattozo CA  Esposito F  Kelly DF 《Surgical neurology》2006,66(4):371-6; discussion 376
BACKGROUND: The efficacy of BioGlue (CryoLife, Inc, Atlanta, Ga) surgical adhesive in transsphenoidal surgery was assessed as an adjunct in the prevention of postoperative CSF leaks. METHODS: All patients in whom BioGlue was used for an intraoperative skull base reconstruction were retrospectively identified. Intraoperative CSF leaks were graded according to size (grade 1, small weeping leak without obvious diaphragmatic defect; grade 2, moderate leak with a definite diaphragmatic defect; grade 3, large diaphragmatic and/or dural defect). CSF leak repair was tailored to CSF leak grade. BioGlue was applied as a reinforcement over collagen sponge as the last layer of the repair. RESULTS: Over 28 months, a total of 282 patients underwent endonasal surgery. Of these patients, 124 (79 women; age range, 8-84 years), in 128 procedures, had an intraoperative CSF leak repair reinforced with BioGlue. Pathology included 80 pituitary adenomas, 11 craniopharyngiomas, 7 Rathke's cleft cysts, 6 chordomas, 5 meningiomas, 4 spontaneous CSF leaks, 3 arachnoid cysts, and 8 other parasellar pathologies. There were 62 (48.4%) grade 1, 41 (32.0%) grade 2, and 25 (19.5%) grade 3 leak repairs. The overall repair failure rate was 1.6% (2 cases), with the failures occurring in patients with grade 3 leaks, including 1 who developed meningitis; there was no failure of grades 1 and 2 leaks. The 2 failures were attributed largely to technical aspects of the repair rather than to failure of BioGlue per se. CONCLUSIONS: BioGlue appears to be an effective adjunct in preventing postoperative CSF leaks after transsphenoidal surgery. However, careful attention to technical details of the repair is still required to prevent failures, especially when closing large dural and diaphragmatic defects.  相似文献   

16.
BACKGROUND: Unilateral lung volume reduction procedures are used to treat pulmonary emphysema. The most significant technical problem with this operation is an air leak from the pulmonary stump. Bovine pericardium has been used to prevent air leaks but is associated with interstitial pneumonia and a high cost. METHODS: The fold plication method was devised to prevent postoperative air leaks to avoid interstitial pneumonia, and to decrease cost. This technique was applied in 20 consecutive patients with emphysema who underwent a unilateral lung volume reduction operation via a thoracoscopic two windows approach. RESULTS: The operative time was approximately 1 hour. There was minimal postoperative bleeding, no persistent air leaks, and no evidence of pneumonia. Pulmonary function improved in all patients. CONCLUSIONS: The unilateral fold plication method is an economical and safe alternative to bovine pericardial patching after lung volume reduction operation to prevent stump air leaks.  相似文献   

17.
Objective: We worked to devise a new way to prevent postoperative persistent air leaks in high-risk pulmonary surgery patients. Methods: From November 1993 to June 2002, 60 patients with difficult to control intraoperative pulmonary air leakage were treated using bioabsorbable polyglycolide felt patches soaked in fibrin glue to cover the leakage site. Results: After application, the felt patch adhered tightly to the lung surface without peeling off, enabling good leakage closure with only 2 ml of fibrin glue used. Air leakage was controlled successfully in 52 (86.7%) of the 60. Four of the 8 patients in whom this method failed to stop air leakage also developed mild pyothorax, with 2 requiring a second operation by video-assisted thoracic surgery. Leakage was eventually controlled in all patients, with no postoperative deaths relating to air leakage. Conclusions: Fibrin-glue-soaked bioabsorbable felt patches effectively seal intraoperative intractable air leaks. Felt patch use may increase the risk of postoperative infection. It should be considered for use on patients with fistulas that cannot be controlled by direct closure or otherwise intraoperatively and who may potentially develop uncontrollable air leakage postoperatively.  相似文献   

18.
Objective: Post-transplant diabetes mellitus (PTDM) is a common and potentially serious complication after solid organ transplantation. There are only a few data, however, about the incidence of DM in patients undergoing lung transplantation. Patients and methods: The medical records of 119 consecutive patients who underwent lung transplantation from 1998 to September 2004 were reviewed. Patients were divided in three groups according to their diabetes status, including pre-transplant DM, the PTDM group and those without DM. Patient records and all laboratory data were reviewed and the clinical course of diabetes was monitored. All recipients were treated with tacrolimus based regimen. Results: Mean follow-up for all patients was 25 ± 10. Twenty-three patients had DM in the pre-lung transplantation (LTX) DM group. PTDM developed in 34 of the remaining 96 patients (35.4%) with an incidence of 20%, 23% after 6 months and 12 months post-transplant. No significant difference was noted between 12 and 24 months post-LTX. The patients who developed DM were older (57 ± 15 vs 53 ± 13 years, p = 0.009), had increased BMI (26 ± 5 vs 24 ± 4, p = 0.0001), shorter time from diagnosis to LTX (21 ± 13 vs 28 ± 18 months, p = 0.007) more cytomegalovirus infection and more acute rejection and hyperglycemia in the first month after LTX. Four patients died in the PTDM group compared to nine patients in the no-DM group (12% vs 14%; p = 0.72). Conclusions: Post-transplant diabetes is a common complication in lung transplant patients receiving tacrolimus-based immunosuppression. The risk for developing PTDM is greatest among older recipients, those obese, and among recipients with more rejections episodes.  相似文献   

19.
Bariatric surgery is recommended for Indian patients with body mass index (BMI) >32.5 kg/m2 with at least one comorbidity and >37.5 kg/m2 without a comorbidity. In laparoscopic sleeve gastrectomy, bleeding and leakage from the staple line are common post-operative events. Peri-Strips Dry® with Veritas® (PSD-V) is used in staple-line reinforcement. This was a single-investigator, multicenter, randomized study of 100 patients undergoing standard sleeve gastrectomy with a 34 or 36 French bougie. Patients were randomized 1:1 to PSD-V or control groups; no buttress material was used in the control group. The primary objective was to assess complication rates (any staple-line bleed or leak from the intra-operative visit through day 30) associated with sleeve gastrectomy. Surgical time (from first incision to closure of last incision) and the number of clips and/or sutures used to control bleeding were also assessed. Fewer staple-line bleeds were observed in the PSD-V group than the control group (23/51 [45.1 %] vs 39/49 [79.6 %] patients; p?=?0.0005), and the bleeding was of a lower severity (p?=?0.0002). No staple-line leaks were observed. Surgical time was shorter in patients who received PSD-V (58.8 vs 72.8 min; p?=?0.0153), and fewer patients required hemostatic clips and/or sutures (10/51 [19.6 %] vs 33/49 [67.3 %] patients; p?相似文献   

20.
Background: Staple-line leakage is a potentially devastating complication of Roux-en-Y gastric bypass (RYGBP). Bovine pericardial strips (BPS) have been used to reinforce staple-lines in pulmonary resections and have been shown to decrease air-leaks.This study examined the use of BPS to decrease gastric staple-line leaks. Methods: 250 consecutive patients undergoing laparoscopic RYGBP had BPS used for the gastric pouch. Ease of use, operative complications, and visual bleeding were recorded. In addition, the postoperative leak rate was compared to 100 consecutive patients operated on prior to the study when BPS was not used. Results: Patient characteristics were the same for both groups and comparable with most published data. With the use of BPS, there were no operative complications and no meaningful increase in operating time. BPS reinforced staple-lines had no visual bleeding. In the 100 cases without BPS, there were 2 staple-line leaks (2%) both of which required emergency exploration. One additional patient was subsequently found to have a gastrogastric fistula. In the 250 patients who had BPS-reinforced staple-lines, there were no acute leaks.Three patients were subsequently found to have gastrogastric fistula. None required emergency surgery. Conclusion: In this non-randomized trial, BPS were found to be easy and safe to use. In addition, staple-line hemorrhage was essentially non-existent. Although the reduction in gastric staple-line leak rate may also be attributed to learning curve, there were no acute leaks in 250 patients with BPS, which is below the published norms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号