首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
The purpose of this research was to investigate the influence of sock addition and removal on residual-limb fluid volume in people using prosthetic limbs. We used bioimpedance analysis to measure residual-limb extracellular fluid volume on 28 transtibial amputee subjects during 30 min test sessions. Upon addition of a one-ply polyester sock, residual-limb fluid volume changes ranged from -4.0% to 0.8% (mean -0.9 +/- 1.3%) of the initial limb fluid volume. Changes for sock removal ranged from -1.2% to 2.8% (mean 0.5 +/- 0.8%). Subjects who reduced in fluid volume with both addition and removal of a sock and subjects with high positive ratios between the fluid-volume loss upon sock addition and gain upon sock removal (high add/remove [AR] ratios) tended to have arterial disease, were obese, and were smokers. Subjects with low positive AR ratios, subjects who increased in fluid volume both with sock addition and removal, and a single subject who increased in fluid volume with sock addition and decreased with sock removal tended to be nonsmokers and either individuals in good health without complications or individuals without arterial problems. Results are relevant for the anticipation of limb volume changes during prosthetic fitting and toward the design of adjustable-socket technologies.  相似文献   

2.
BackgroundSmall intermittent adjustments of socket size using adjustable sockets may be a means for people with transtibial amputation to better maintain residual limb fluid volume and limb position while using a prosthesis.MethodsSocket size, limb fluid volume, and distance from the limb to the socket, termed “sensed distance,” were recorded while participants with transtibial amputation walked on a treadmill wearing a motor-driven, cabled-panel, adjustable socket. Researchers made frequent socket size adjustments using a mobile phone app to identify participants' acceptable socket size range. Limb fluid volume and sensed distance were then monitored as incremental adjustments were made to the socket.FindingsProsthesis users in this study (n = 10) accepted socket sizes between −5% and +5% of their neutral socket volume. There was a rapid increase in limb fluid volume and sensed distance upon socket enlargement, and a rapid decrease upon reduction. Subsequently, there were gradual changes in fluid volume and sensed distance. While visually monitoring limb fluid volume data in real time, researchers were able to adjust socket size to maintain consistent limb fluid volume within a −0.7% to +0.9% volume change for 24 min.InterpretationParticipant residual limbs compensated to socket size adjustment. Using socket-mounted sensors to monitor limb-socket mechanics, an automatic adjustable socket that maintains limb fluid volume may be possible and may improve socket fit in instances where fit deteriorates during use.  相似文献   

3.
Prosthetic gel liners are often prescribed for persons with lower-limb amputations to make the prosthetic socket more comfortable. However, their effects on residual limb pressures and gait characteristics have not been thoroughly explored. This study investigated the effects of gel liner thickness on peak socket pressures and gait patterns of persons with unilateral transtibial amputations. Pressure and quantitative gait data were acquired while subjects walked on liners of two different uniform thicknesses. Fibular head peak pressures were reduced (p = 0.04) with the thicker liner by an average of 26 +/- 21%, while the vertical ground reaction force (GRF) loading peak increased 3 +/- 3% (p = 0.02). Most subjects perceived increased comfort within the prosthetic socket with the thicker liner, which may be associated with the reduced fibular head peak pressures. Additionally, while the thicker liner presumably increased comfort by providing a more compliant limb-socket interface, the higher compliance may have reduced force and vibration feedback to the residual limb and contributed to the larger vertical GRF loading peaks. We conclude that determining optimal gel liner thickness for a particular individual will require further investigations to better identify and understand the compromises that occur between user perception, residual-limb pressure distribution, and gait biomechanics.  相似文献   

4.
Interface pressures were measured during ambulation with a normal total-surface weight-bearing suction socket and a vacuum-assisted socket. The vacuum-assisted socket has been shown to eliminate daily volume loss. Urethane liners were instrumented with five force-sensing resistors to measure positive pressures and one air pressure sensor at the distal end of the liner to document negative pressures. Nine unilateral transtibial amputees participated in the study. The vacuum-assisted socket created significantly lower positive-pressure impulse (42.8, 39.6 kPa x s) and peak pressures (83.5, 80.0 kPa) during the stance phase. The pressure impulse (-10.5, -13.3 kPa x s), average (-21.2, -26.5 kPa), and peak (-28.5, -36.3 kPa) negative pressures during swing phase were significantly greater in magnitude with the vacuum-assisted socket. We believe that lower positive pressures seen during stance using the vacuum-assisted socket reduces the fluid forced out and greater negative pressures seen during swing increases the amount of fluid drawn into the limb, thereby preventing volume loss.  相似文献   

5.
We examined the application of outcome measures to determine changes in function caused by standardized functional prosthetic gait training and the use of four different prosthetic feet in people with unilateral transtibial limb loss. Two self-report measures (Prosthetic Evaluation Questionnaire-Mobility Scale [PEQ-13] and Locomotor Capabilities Index [LCI]), and three performance-based measures (Amputee Mobility Predictor with a prosthesis [AMPPRO], 6-minute walk test [6MWT] and step activity monitor [SAM]) were used. Ten people with unilateral transtibial limb loss, five with peripheral vascular disease (PVD) and five without PVD, completed testing. Subjects were tested at baseline and after receiving training with their existing prosthesis and with the study socket and four prosthetic feet, i.e., SACH (solid ankle cushion heel), SAFE (stationary attachment flexible endoskeletal), Talux, and Proprio feet, over 8 to 10 weeks. Training was administered between testing sessions. No differences were detected by the PEQ-13, LCI, 6MWT, or SAM following training and after fitting with test feet. The AMPPRO demonstrated differences following training with the existing prosthesis in the PVD group and between selected feet from baseline testing ( p 相似文献   

6.
OBJECTIVE: To determine and compare the kinematics of the sound and prosthetic limb in five of the world's best unilateral amputee sprinters. SUBJECTS: Five men, all unilateral lower-limb amputee (one transfemoral, four transtibial) athletes. The individual with transfemoral amputation used a Endolite Hi-activity prosthesis incorporating a CaTech hydraulic swing and stance control unit, a Flex-Foot Modular III, and an ischial containment total contact socket. Those with transtibial amputations used prostheses incorporating a Flex-Foot Modular III and patellar tendon-bearing socket, with silicone sheath liner (Iceross) and lanyard suspension. DESIGN: Case series. Subjects were videotaped sprinting through a performance area. Sagittal plane lower-limb kinematics derived from manual digitization (at 50 Hz) of the video were determined for three sprint trials of the prosthetic and sound limb. Hip, knee, and ankle kinematics of each subject's sound and prosthetic limb were compared to highlight kinematic alterations resulting from the use of individual prostheses. Comparisons were also made with mean data from five able-bodied men who had similar sprinting ability. RESULTS: Sound limb hip and knee kinematics in all subjects with amputation were comparable to those in able-bodied subjects. The prosthetic knee of the transfemoral amputee athlete fully extended early in swing and remained so through stance. In the transtibial amputee athletes, as in able-bodied subjects, a pattern of stance flexion-extension was evident for both limbs. During stance, prosthetic ankle angles of the transtibial amputee subjects were similar to those of the sound side and those of able-bodied subjects. CONCLUSION: Prosthetic limb kinematics in transtibial amputee subjects were similar to those for the sound limb, and individuals achieved an "up-on-the-toes" gait typical of able-bodied sprinting. Kinematics for the prosthetic limb of the transfemoral amputee subject were more typical of those seen for walking. This resulted in a sprinting gait with large kinematic asymmetries between contralateral limbs.  相似文献   

7.
Bioimpedance analysis was used to measure the residual limb fluid volume of seven transtibial amputee subjects using elevated vacuum sockets and nonelevated vacuum sockets. Fluid volume changes were assessed during sessions with the subjects sitting, standing, and walking. In general, fluid volume losses during 3 or 5 min walks and losses over the course of the 30 min test session were less for elevated vacuum than for suction. Numerous variables, including the time of day that data were collected, soft tissue consistency, socket-to-limb size and shape differences, and subject health, may have affected the results and had an equivalent or greater effect on limb fluid volume compared with elevated vacuum. Researchers should well consider these variables in the study design of future investigations on the effects of elevated vacuum on residual limb volume.  相似文献   

8.
Purpose. To assess the mechanical behaviour at interface for unilateral transtibial amputees during walking when the prosthesis is misaligned, since studies examining interface pressure between residual limb and prosthetic socket have been restricted to unsupported stance and natural gait.

Method. One male subject with transtibial amputation volunteers for the study. Interface pressures over five sites are measured under three sagittal alignment settings. MP (mean peak interface pressure), TP90+ (time in which pressure exceeded 90% of peak pressure) and TPI90+ (time-pressure integral at the period of sustained sub-maximal load) are discussed for each alignment setting.

Results. Compared with optimal alignment, the trend of interface pressure, the mean peak pressure do not change much, but the duration of sub-maximal pressure changes remarkably, except that at the patellar tendon, and finally the TPI90+ changes considerably with different alignment settings.

Conclusions. The results offer the clinician and paramedical staff further insight in residual limb/socket interface mechanics in the transtibial amputation patients and provide potentially useful information for socket design and prosthesis fitting.  相似文献   

9.
This study examined exercise-induced hypoxaemia (EIH) and plasma volume contraction as modulators of serum erythropoietin (Epo) production. Five athletes cycled for 3 min at supra-maximal power outputs, at each of two different elevations (1,000 m and 2,100 m). Five subjects were exposed to normobaric hypoxia (F(I)O(2)=0.159), seven subjects underwent plasmapheresis to reduce plasma volume and eight subjects were time controls for Epo levels. Oxyhaemoglobin saturation was significantly reduced during exercise and during normobaric hypoxia. The time period of haemoglobin oxygen saturation <91% was 24+/-29 s (mean+/-S.D., n=5) for exercise at 1000 m, 136+/-77 s (mean+/-S.D., n=5) for exercise at 2100 m and 178+/-255 s (mean+/-S.D., n=5) with resting hypoxic exposure. However, significantly increased serum Epo levels were observed only following exercise (24+/-3%; mean+/-S.D., n=5 at 1,000 m and 36+/-5%; mean+/-S.D., n=5 at 2,100 m). Volume contraction also resulted in increased serum Epo (35+/-6%; mean+/-S.D., n=7) in spite of a significant rise in haematocrit of 2.2%. Despite similar degrees of arterial desaturation, only the hypoxaemia induced by exercise was associated with an increase in serum Epo. This finding indicates that other factors, in addition to hypoxaemia, are important in modulating the production of Epo in response to exercise. Volume depletion in the absence of exercise resulted in increases in Epo levels that were comparable with those observed in response to exercise. The paradoxical responses of the increased haematocrit and the increase in Epo in subjects undergoing plasmapheresis suggests that plasma volume may also modulate the production of Epo.  相似文献   

10.
We investigated electrical bioimpedance as a potential measurement modality to assess residual-limb volume change in lower-limb amputees. Four strip electrodes were positioned across the anterior lateral to posterior lateral aspects of the proximal lower leg or residual limb such that the outer pair applied current and the inner pair sensed voltage. A commercial bioimpedance analyzer supplied current at 50 fre quencies between 5 kHz and 1 MHz and then used a well-validated model to determine fluid resistance. From these data, extracellular fluid volume (V(ECF)) could be estimated. Bench test evaluation showed the instrument to have a root-mean-square error of less than 0.014% over a 1 h interval. Tests of subjects who had been transtibial amputees for at least 2 yr showed V(ECF) changes from postural adjustments well outside the instrument error and normal minute-to-minute biological variability. The rate of V(ECF) change while standing with the prosthesis donned was greater for diabetic subjects than for nondiabetic subjects. Bioimpedance analysis may have use in prosthetics research, where comparing residual-limb volume at different time points or under different treatment conditions is of interest.  相似文献   

11.
12.
OBJECTIVE: To determine the magnitude of posture-related changes in blood components. SUBJECTS AND METHODS: Twenty-eight healthy subjects were studied between 1995 and 2004 at the Vanderbilt Autonomic Dysfunction Center, Nashville, Tenn. Lying and standing plasma volume (PV) and hematocrit (Hct) values were determined for each subject. RESULTS: Individual PV decreases on standing ranged from 6% to 25%. The absolute mean +/- SD PV shift was 417+/-137 mL (range, 149-717 mL). The mean +/- SD change in Hct was from 37.7%+/-2.8% while supine to 41.8%+/-3.2% within 30 minutes of standing. This absolute increase in Hct of 4.1%+/-1.3% represents a relative increase of 11.0%+/-3.6% from lying to standing. CONCLUSIONS: Changes in posture can lead to substantial changes in Hct, which may be attributed mistakenly to blood loss or acute anemia and result in a cascade of unnecessary diagnostic costs. In reality, these changes represent postural pseudoanemia, a normal physiological response to a change in position from standing to lying (and vice versa).  相似文献   

13.
OBJECTIVE: To determine whether washing the residual limb and silicone liner reduces the associated skin problems in transtibial amputees who wear a total surface bearing (TSB) socket. DESIGN: Case series. SETTING: General community. PATIENTS: Eighty-three transtibial amputees (65 men, 18 women; mean age, 53.4 yr) in western Japan who used or had used a TSB socket with a silicone liner in the previous 5 years. INTERVENTION: Participants took a self-administered questionnaire that included items concerning their personal profile, daily life activities, period of TSB use (yr), hours of TSB use daily, washing frequency of the residual limb and silicone liner, the method of washing, and any associated hygiene problems. MAIN OUTCOME MEASURES: Logistic regression analysis was applied to examine factors related to hygiene problems. Predicted values include hygiene problems (perspiration, eruptions, itching, odor) and explanatory values include TSB use, daily life activity, and washing of limb and prosthetic. RESULTS: Fifty-five subjects washed the residual limb, and 44 subjects washed the silicone liner every day. Itching, perspiration, eruption, and odor were frequent hygiene problems. Perspiration was noted less by women, eruption more by older subjects, and itching and odor more by younger subjects. Washing the silicone liner every day was associated with fewer reports of skin eruption. CONCLUSION: Keeping the residual limb and silicone liner clean is important to reduce skin problems, but hygiene problems of the residual limb and silicone liner still remain to be resolved.  相似文献   

14.
The purpose of this study was to assess the accuracy of in vivo measurement of organ volume using 3DUS and compare the results to 2D sonographic methods using the urinary bladder as the target organ and voided urine volume for validation. Fifty normal volunteers were studied. 2D volume measurements were based on length, width, and depth data and assumed a regular geometric model. 3D volume measurements were based on masked slices with the voxels integrated over the entire bladder. Voided urine volumes ranged from 35 ml to 701 ml. Residual urine volume was present in 48% of the subjects and ranged from 1% to 14% of the voided volume. 2D volume estimates for all 50 subjects had a mean absolute value of the error of 27.5% +/- 17.8%. 3D volume measurements had a mean absolute value of the error of 4.3% +/- 3.7% (transverse) and 5.6% +/- 3.8% (longitudinal). 3DUS provided more accurate volume measurements than 2DUS, particularly for irregularly shaped organs.  相似文献   

15.
OBJECTIVE: To investigate if and to what extent patients with a transtibial amputation are less successful in avoiding unexpected obstacles while walking than healthy adults. DESIGN: Experimental 2-group design. SETTING: Dutch rehabilitation center. PARTICIPANTS: Eleven patients with a transtibial amputation and 14 healthy controls. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Subjects walked on a treadmill at .56m/s. In 2 series of 12 trials each, an obstacle was dropped in front of the prosthetic or the nonprosthetic leg of the amputation group and the left leg of the control group at different phases during the step cycle. It was noted which avoidance strategy was used (a long step strategy [LSS] or a short step strategy [SSS]) and whether the obstacle was avoided successfully or not. These data were expressed as a percentage of the total number of trials completed by each subject. RESULTS: With either leg, the amputation group made significantly more errors than the control subjects (prosthetic leg, 24%+/-17%; nonprosthetic leg, 21%+/-17% vs 2%+/-2% for the control group). Highest failure rates were in the amputation group when time pressure was high, requiring an SSS, especially on the prosthetic side. An LSS under time pressure, however, nearly always resulted in failure for both the prosthetic and nonprosthetic legs. Subjects with the longest time since amputation were most successful in avoiding unexpected obstacles. CONCLUSIONS: Under time pressure, patients with a lower-leg prosthesis perform best when they use their nonprosthetic leg as the lead limb in an SSS. The fact that some subjects with the longest time since amputation made no errors suggests that over many years it is possible to relearn the appropriate avoidance reactions sufficiently fast.  相似文献   

16.
Klute GK, Berge JS, Biggs W, Pongnumkul S, Popovic Z, Curless B. Vacuum-assisted socket suspension compared with pin suspension for lower extremity amputees: effect on fit, activity, and limb volume.

Objective

To investigate the effect of a vacuum-assisted socket suspension system as compared with pin suspension on lower extremity amputees.

Design

Randomized crossover with 3-week acclimation.

Setting

Household, community, and laboratory environments.

Participants

Unilateral, transtibial amputees (N=20 enrolled, N=5 completed).

Interventions

(1) Total surface–bearing socket with a vacuum-assisted suspension system (VASS), and (2) modified patellar tendon–bearing socket with a pin lock suspension system.

Main Outcome Measures

Activity level, residual limb volume before and after a 30-minute treadmill walk, residual limb pistoning, and Prosthesis Evaluation Questionnaire.

Results

Activity levels were significantly lower while wearing the vacuum-assisted socket suspension system than the pin suspension (P=.0056; 38,000±9,000 steps per 2wk vs 73,000±18,000 steps per 2wk, respectively). Residual limb pistoning was significantly less while wearing the vacuum-assisted socket suspension system than the pin suspension (P=.0021; 1±3mm vs 6±4mm, respectively). Treadmill walking had no effect on residual limb volume. In general, participants ranked their residual limb health higher, were less frustrated, and claimed it was easier to ambulate while wearing a pin suspension compared with the VASS.

Conclusions

The VASS resulted in a better fitting socket as measured by limb movement relative to the prosthetic socket (pistoning), although the clinical relevance of the small but statistically significant difference is difficult to discern. Treadmill walking had no effect, suggesting that a skilled prosthetist can control for daily limb volume fluctuations by using conventional, nonvacuum systems. Participants took approximately half as many steps while wearing the VASS which, when coupled with their subjective responses, suggests a preference for the pin suspension system.  相似文献   

17.
Volume-rendered 3-dimensional echocardiography (3DE) acquired with small imaging intervals has been validated for accurate left ventricular (LV) volume measurement. However, its clinical application is often impeded by the lengthy acquisition time. The aim of this study was to examine the accuracy of LV volume measurement from 3DE data acquired at different intervals. METHODS: Transthoracic 3DE LV data sets were acquired at intervals of 2 degrees, 6 degrees, 9 degrees, 12 degrees, 15 degrees, 18 degrees, and 20 degrees in 10 human subjects with various cardiac shapes and function. The LV end-diastolic volume and end-systolic volume were measured from each 3DE data set with the "summation of disks" method. Interobserver and intraobserver variability were also examined. Measurements obtained from data acquired at 2 degrees intervals were used as references for comparison. RESULTS: From 10 subjects a total of 70 3DE data sets were obtained. Data acquisition time decreased from 189 +/- 143 seconds at intervals of 2 degrees to 19 +/- 6 minutes at 20 degrees. No statistically significant difference was found among the measurements derived from data obtained at various intervals. Excellent agreement was obtained between interobserver and intraobserver measurements. CONCLUSION: Data acquired at 12 degrees and 15 degrees intervals remained accurate for LV volume measurement and saved over 80% of time in comparison with data acquired at 2 degrees intervals. A further increase in imaging intervals tended to underestimate LV volumes without significant acceleration of the procedure.  相似文献   

18.
BACKGROUND: Studies examining the stump/socket interface stresses have been restricted to unsupported stance and natural gait, i.e. walking at a comfortable speed on flat and straight walkway. However, the pressure behaviour as to the interface in unilateral transtibial amputees during walking on stairs, slope and non-flat road is unclear. METHODS: Pressure distribution changes at multiple points, expressed as mean peak stump/socket interface pressure, mean pressure level over 90% of peak pressure, time in which pressure exceeded 90% of peak pressure and time-pressure integral at the period of sustained sub-maximal load, were measured during natural ambulating and walking on stairs, slope and non-flat road. FINDINGS: Compared with natural gait, the mean peak pressure and sustained sub-maximal load increase notably over the patellar tendon during walking on stairs and non-flat road, and however decrease or change insignificantly at the patellar tendon on slope and over other measured areas in all conditions; moreover the time period of sustained sub-maximal load changes remarkably, except over the patellar tendon during walking up slope and over the popliteal area on non-flat road; finally, the time-pressure integral in the time period of sustained sub-maximal load changes considerably, except at the patellar tendon during walking up slope. INTERPRETATION: The pressure characteristics during natural ambulating seem not to be highly predictive of what occurs in the conditions of walking on stairs, slope and non-flat road, which leads to significant increase in amplitude domain of tissue loading only at the patellar tendon, and however to remarkable changes in temporal sequences of tissue (un-)loading almost in all measured regions.  相似文献   

19.

Background

Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet.

Methods

A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5 mm, 10 mm and 15 mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment.

Findings

Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P < 0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P < 0.05) in the moment at 30% and 75% of stance for all comparisons.

Interpretation

The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses.  相似文献   

20.
AIMS : Permanent ventricular pacing in children is associated with ventricular dysfunction due to asynchronous activation. It is unclear whether paced QRS intervals increase disproportionately over time, which could potentially cause ventricular dysfunction. METHODS : A total of 52 children, with bipolar steroideluting epicardial leads implanted at a median age of 5.6 years (0.0-17.4), was analyzed and followed up to 12.2 years (median 3.7). Patients were subdivided in two groups: right (RV, n = 21) and left (LV, n = 31) ventricular pacing. To correct for age, standard deviation scores (Z-scores) for paced QRS and QTc intervals were calculated from published standard-ECG norm-values. As a measure for individual paced QRS and QTc interval changes, a regression slope coefficient (incline(i)) was calculated for each patient's course. RESULTS : Mean Z-scores for paced QRS intervals at first and last follow-up were 4.7 +/- 1.2 and 4.9 +/- 0.9 for group RV, 4.4 +/- 1.1 and 4.8 +/- 1.1 for group LV. Incline(i) of paced QRS (group RV: 0.038 [-0.27-0.12], group LV: 0.147 [-0.05-0.30]; p = 0.07) and QTc intervals (group RV: 0.026 [-0.08-0.06], group LV: 0.023 [-0.04-0.09]; p = 0.63) did not differ between both groups and indicated limited interval changes over time. CONCLUSION : Neither epicardial pacing of the right nor left ventricle caused disproportionate paced QRS or QTc interval increases over time. An age-related prolongation of the electrical activation unlikely causes ventricular dysfunction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号