1.
OBJECTIVE: Dual-head gamma cameras with sodium iodide (NaI) detectors operated in coincidence mode provide a new approach for imaging with positron-labeled tracers. The purpose of this study was to evaluate the feasibility of FDG imaging with positron coincidence detection gamma camera (PCD) in detecting lung tumor in comparison with FDG imaging with the dedicated positron emission tomography (PET). METHODS AND MATERIAL: Twenty-six lesions of 13 patients with suspected lung cancer were studied with both FDG PET and FDG PCD on the same day. Pulmonary lesions were analyzed visually and semi-quantitatively using the ratio of target-to-background counts (T/B ratio). RESULTS AND CONCLUSIONS: FDG PCD and FDG PET could detect visually 21 lesions (80.8%) and 23 lesions (88.0%), respectively. The mean T/B ratio and standard deviation (S.D.) of FDG PCD was 4.6 +/- 3.9, significantly lower than that of FDG PET (11.4 +/- 6.6, P<0.001). When pulmonary lesions were no more than 2.0 cm in diameter, the sensitivity of FDG PCD was 37.5%, significantly inferior to that of FDG PET (62.5%, P<0.001). There was no statistically significant difference of the sensitivity between the FDG PCD and FDG PET in lesions of more than 2.0 cm in diameter. FDG PCD with uniform attenuation correction was clinically available in detecting lung cancer. However, the sensitivity for small lesions less than 2.0 cm was limited. The application of measured attenuation correction and scatter correction may to be needed to improve the detectability of FDG PCD, especially for detecting small lung cancer.  相似文献   

2.
The purpose of this study was to compare the utility of a dual-head positron coincidence detection gamma camera (PCD) with that of dedicated positron emission tomography (PET) in the imaging of various malignancies using (18)F-fluorodeoxyglucose (FDG). 25 patients with known or suspected malignancies at various sites underwent imaging with both methods, and diagnostic performance on a lesion basis was compared. Tumour lesions were analyzed visually and semi-quantitatively using the ratio of tumour-to-background counts (T/B ratio). FDG PCD and FDG PET visually detected 34 (72.3%) lesions and 37 (78.7%) lesions, respectively. The mean T/B ratio and standard deviation (SD) of FDG PCD was 3.5+/-3.3, significantly lower than that of FDG PET (8.4+/-7.1, p<0.001). When tumour lesions were less than 2.0 cm in diameter, the sensitivity of FDG PCD was 37.5%, significantly inferior to that of FDG PET (50.0%, p<0.01). Sensitivity between FDG PCD and FDG PET in lesions of more than 2.0 cm diameter showed no statistically significant difference. This study indicates that FDG imaging with a dual-head coincidence detection gamma camera can provide suitable diagnostic performance for lesions greater than 2.0 cm diameter, but performed significantly worse than dedicated PET for lesions smaller than this.  相似文献   

3.
Dual-headed gamma cameras with coincidence detection (MCD) are increasingly used for imaging of positron-emitting tracers, such as fluorine-18 fluorodeoxyglucose (FDG). In this study, we examined differences between FDG MCD and FDG positron emission tomography (PET) as the gold standard to determine whether FDG MCD could be used for assessment of myocardial viability in daily practice. Nineteen patients with a previous myocardial infarction (17 men; mean left ventricular ejection fraction 44%+/-13%) underwent FDG MCD, FDG PET, resting echocardiography and technetium-99m tetrofosmin gated single-photon emission tomography (SPET). At the 50% threshold value for FDG PET, the area under the receiver operating characteristic curve for FDG MCD was 0.77+/-0.03. In 107 dyssynergic segments on echocardiography and 151 segments with hypoperfusion on 99mTc-tetrofosmin SPET, the specificity of FDG MCD for the detection of myocardial viability was 72% and 76% respectively, with a sensitivity of 69% and 72% respectively. Regional analysis showed a significantly lower agreement of FDG MCD and FDG PET in the inferior and septal regions (58% for dyssynergic segments and 65% for segments with hypoperfusion), as compared with the other regions (85% for dyssynergic regions, P<0.05, and 86% for segments with hypoperfusion, P<0.05). Five patients (26%), who all had a body mass index > or =25% kg/m2, showed more than 25% disagreement between FDG MCD and FDG PET. Because of the moderate overall agreement with FDG PET, the low sensitivity in akinetic or dyskinetic regions and the low agreement in the inferior and septal regions, further studies and implementations of technical developments are needed before FDG MCD can be introduced into clinical practice for the assessment of myocardial viability.  相似文献   

4.
This study assessed a dual-head coincidence gamma camera (hybrid PET) equipped with single-photon transmission for myocardial fluorine-18 fluorodeoxyglucose (FDG) imaging by comparing this technique with conventional positron emission tomography (PET) using a dedicated ring PET scanner. Twenty-one patients were studied with dedicated FDG ring PET and FDG hybrid PET for evaluation of myocardial glucose metabolism, as well as technetium-99m tetrofosmin single-photon emission tomography (SPET) to estimate myocardial perfusion. All patients underwent transmitted attenuation correction using germanium-68 rod sources for ring PET and caesium-137 point sources for hybrid PET. Ring PET and hybrid PET emission scans were started 61+/-12 and 98+/-15 min, respectively, after administration of 154+/-31 MBq FDG. Attenuation-corrected images were reconstructed iteratively for ring PET and hybrid PET (ac-hybrid PET), and non-attenuation-corrected images for hybrid PET (non-ac-hybrid PET) only. Tracer distribution was analysed semiquantitatively using a volumetric vector sampling method dividing the left ventricular wall into 13 segments. FDG distribution in non-ac-hybrid PET and ring PET correlated with r=0.36 (P<0.0001), and in ac-hybrid PET and ring PET with r=0.79 (P<0.0001). Non-ac-hybrid PET significantly overestimated FDG uptake in the apical and supra-apical segments, and underestimated FDG uptake in the remaining segments, with the exception of one lateral segment. Ac-hybrid PET significantly overestimated FDG uptake in the apical segment, and underestimated FDG uptake in only three posteroseptal segments. A three-grade score was used to classify diagnosis of viability by FDG PET in 136 segments with reduced perfusion as assessed by SPET. Compared with ring PET, non-ac-hybrid PET showed concordant diagnoses in 80 segments (59%) and ac-hybrid PET in 101 segments (74%) (P<0.001). Agreement between ring PET and non-ac-hybrid PET was best in the basal lateral wall and in the apical-septal segment (80%-100%), and lowest in the apical, supra-apical and posteroseptal segments (41%-55%). Ac-hybrid PET showed highest agreement in the lateral wall (89%-100%), and lowest agreement in the apical and the basal septal segments (59%-67%). In conclusion, non-uniform attenuation correction with singles transmission significantly improves the diagnostic accuracy of myocardial dual-head gamma camera coincidence imaging with FDG. However, results equivalent to those obtained with ring PET cannot yet be attained, even if attenuation correction is applied. New rebinning algorithms for three-dimensional data may further improve the performance of ac-hybrid PET and should be evaluated in future studies.  相似文献   

5.
This study assessed a dual-head coincidence gamma camera (hybrid PET) equipped with single-photon transmission for myocardial fluorine-18 fluorodeoxyglucose (FDG) imaging by comparing this technique with conventional positron emission tomography (PET) using a dedicated ring PET scanner. Twenty-one patients were studied with dedicated FDG ring PET and FDG hybrid PET for evaluation of myocardial glucose metabolism, as well as technetium-99m tetrofosmin single-photon emission tomography (SPET) to estimate myocardial perfusion. All patients underwent transmitted attenuation correction using germanium-68 rod sources for ring PET and caesium-137 point sources for hybrid PET. Ring PET and hybrid PET emission scans were started 61ᆠ and 98ᆣ min, respectively, after administration of 154ᆳ MBq FDG. Attenuation-corrected images were reconstructed iteratively for ring PET and hybrid PET (ac-hybrid PET), and non-attenuation-corrected images for hybrid PET (non-ac-hybrid PET) only. Tracer distribution was analysed semiquantitatively using a volumetric vector sampling method dividing the left ventricular wall into 13 segments. FDG distribution in non-ac-hybrid PET and ring PET correlated with r=0.36 (P<0.0001), and in ac-hybrid PET and ring PET with r=0.79 (P<0.0001). Non-ac-hybrid PET significantly overestimated FDG uptake in the apical and supra-apical segments, and underestimated FDG uptake in the remaining segments, with the exception of one lateral segment. Ac-hybrid PET significantly overestimated FDG uptake in the apical segment, and underestimated FDG uptake in only three posteroseptal segments. A three-grade score was used to classify diagnosis of viability by FDG PET in 136 segments with reduced perfusion as assessed by SPET. Compared with ring PET, non-ac-hybrid PET showed concordant diagnoses in 80 segments (59%) and ac-hybrid PET in 101 segments (74%) (P<0.001). Agreement between ring PET and non-ac-hybrid PET was best in the basal lateral wall and in the apical-septal segment (80%-100%), and lowest in the apical, supra-apical and posteroseptal segments (41%-55%). Ac-hybrid PET showed highest agreement in the lateral wall (89%-100%), and lowest agreement in the apical and the basal septal segments (59%-67%). In conclusion, non-uniform attenuation correction with singles transmission significantly improves the diagnostic accuracy of myocardial dual-head gamma camera coincidence imaging with FDG. However, results equivalent to those obtained with ring PET cannot yet be attained, even if attenuation correction is applied. New rebinning algorithms for three-dimensional data may further improve the performance of ac-hybrid PET and should be evaluated in future studies.  相似文献   

6.
Dual-headed gamma cameras with coincidence detection (MCD) are increasingly used for imaging of positron-emitting tracers, such as fluorine-18 fluorodeoxyglucose (FDG). In this study, we examined differences between FDG MCD and FDG positron emission tomography (PET) as the gold standard to determine whether FDG MCD could be used for assessment of myocardial viability in daily practice. Nineteen patients with a previous myocardial infarction (17 men; mean left ventricular ejection fraction 44%±13%) underwent FDG MCD, FDG PET, resting echocardiography and technetium-99m tetrofosmin gated single-photon emission tomography (SPET). At the 50% threshold value for FDG PET, the area under the receiver operating characteristic curve for FDG MCD was 0.77±0.03. In 107 dyssynergic segments on echocardiography and 151 segments with hypoperfusion on 99mTc-tetrofosmin SPET, the specificity of FDG MCD for the detection of myocardial viability was 72% and 76% respectively, with a sensitivity of 69% and 72% respectively. Regional analysis showed a significantly lower agreement of FDG MCD and FDG PET in the inferior and septal regions (58% for dyssynergic segments and 65% for segments with hypoperfusion), as compared with the other regions (85% for dyssynergic regions, P<0.05, and 86% for segments with hypoperfusion, P<0.05). Five patients (26%), who all had a body mass index ≥25% kg/m2, showed more than 25% disagreement between FDG MCD and FDG PET. Because of the moderate overall agreement with FDG PET, the low sensitivity in akinetic or dyskinetic regions and the low agreement in the inferior and septal regions, further studies and implementations of technical developments are needed before FDG MCD can be introduced into clinical practice for the assessment of myocardial viability. Received 4 December 1999 and in revised form 5 February 2000  相似文献   

7.
Coincidence imaging with a dual-head gamma camera may offer a cost-effective alternative to dedicated PET. The aim of this study was to compare the diagnostic accuracy of coincidence imaging and PET in patients with differentiated thyroid cancer. Thirty-one patients were studied after thyroidectomy and radioiodine ablation. They were injected with a single dose of 300 MBq 18F-FDG. Scanning was performed on a dedicated PET system after 1 hr, and on a coincidence gamma camera after 4 hrs. Based on a lesion-by-lesion comparison, coincidence imaging and PET concurred in 69% of 118 lesions. Based on lesion size, concurrence was 96% in lesions larger than 1.5 cm, and 62% in those between 1 and 1.5 cm. Lesions smaller than 1 cm could not be identified with coincidence imaging. Identical staging was obtained with coincidence imaging and PET in 26/31 patients (84%). In four patients FDG accumulating lesions were shown by both the coincidence camera and the dedicated scanner, but not detectable with any other imaging means and were confirmed histologically on surgery. Although a coincidence camera is technically inferior to a dedicated PET scanner, it may provide clinically useful results in situations were a lesion of sufficient size and FDG uptake is to be expected, e.g. when evaluating a known lesion for malignancy.  相似文献   

8.
This study investigated the validity of myocardial 18F-fluorodeoxyglucose (FDG) imaging with a dual-head gamma camera operated in coincidence detection mode (DCD-I) by comparing this technique with conventional PET and SPECT with ultra-high-energy general-purpose collimators (UHGPs). METHODS: The subjects included 5 healthy volunteers and 20 patients with a history of myocardial infarction. FDG (370 MBq) was injected intravenously after 75-g oral glucose loading, and PET, UHGP SPECT and DCD-I were performed 45, 60 and 210 min, respectively, after the injection. The target-to-background ratio of each imaging method was evaluated for the healthy volunteers by comparing myocardial uptake with uptake in the upper lungs or left ventricular cavity. Agreement between the results of the various imaging methods was investigated for the myocardial infarction patients, as was the validity of DCD-I for assessing myocardial viability as judged by comparison with myocardial perfusion SPECT. The left ventricular wall was divided into 18 regions, and uptake was evaluated using a five-grade defect score (0 = normal; 1-3 = low uptake; 4 = defect). RESULTS: The mean ratio of myocardial counts to lung counts was lower on the DCD images (2.77 +/- 1.12) than on the UHGP SPECT images (3.69 +/- 0.98) (P < 0.05). In contrast, the mean ratio of myocardial counts to left ventricular cavity counts was higher on the DCD images (2.76 +/- 1.36) than on the UHGP SPECT images (1.98 +/- 0.70) (P < 0.05). For the patients, only 30.6% of the defect scores obtained by DCD-I agreed with the scores obtained by PET, and the defect scores in the inferior and septal walls were higher for the DCD images than for the PET images. When DCD-I was compared with PET without attenuation correction (AC), agreement improved to 58.3%. When corrected by a modified AC method, DCD-I improved to 48.1%. Agreement between UHGP SPECT and PET was 55.0%. Of the segments (64) for which the defect score of the myocardial perfusion image was greater than that for the FDG PET image, DCD-I without AC, DCD-I with AC and UHGP SPECT allowed an accurate diagnosis in 12 (18.8%), 31 (48.4%) and 43 (67.2%), respectively. CONCLUSION: The image quality of DCD-I is superior to that of UHGP SPECT. However, because the effect of attenuation is marked, accurate AC, by the transmission method, for example, is required to equal the validity of PET.  相似文献   

9.

Objective

Positron emission tomography (PET) scanning with 13N-ammonia and 18FDG is well established for the detection of myocardial viability. Due to the limited availability of PET facilities, recent studies have combined technetium 99m sestamibi single photon emission computed tomography (SPECT) with 18FDG PET or 18FDG SPECT. This approach enables simultaneous assessment of regional myocardial blood flow and metabolism and substantially increases the capacity for viability detection. To validate whether 99mTc-Sestamibi SPECT can replace 13N-ammonia PET, we compared these two modalities in patients with severe left ventricular dysfunction due to coronary artery disease.

Materials and Methods

Thirty-one patients (mean age 57±8 years; mean ejection fraction 27%±8%) with angiographically verified coronary artery disease were included. In random order, ammonia-PET and sestamibi-SPECT scans were performed. In a 20-segment model of the left ventricle, two blinded observers scored a total of 610 segments on a five-point scale. In a subset of 20 patients, 400 segments were scored twice to evaluate the observer variations of the two techniques. Segmental score differences were used to compare the imaging modalities. The impact on viability detection was assessed by combining the two flow tracers with FDG PET.

Results

Segmental comparison of the PET and SPECT studies yielded similar (difference ≤1) results in 74% of segments, reflecting regional concordance values in the lateral, apical, anterior, septal, and inferior myocardial walls of 86%, 82%, 71%, 66%, and 63%, respectively. The differences in the septal and inferior walls were primarily due to overestimation of perfusion defects by sestamibi SPECT, which yielded a higher proportion of mismatch patterns in those regions. The overall observer variations of the PET and SPECT studies were 7.5% and 5.8%.

Conclusion

Myocardial perfusion imaging with 13N-ammonia PET and 99mTc-sestamibi SPECT yielded similar results in patients with severe left ventricular dysfunction, except for the septal and inferior regions. In these regions, SPECT tended to overestimate perfusion defects. Hence, attenuation correction should be considered when combining FDG PET and sestamibi SPECT for diagnosing myocardial viability to avoid overestimation of mismatch patterns in those regions.  相似文献   

10.
This comparative study was performed to determine whether a conventional planar gamma camera optimised for 511-keV imaging can reliably assess myocardial viability using the fluorine-18 fluorodeoxyglucose (FDG) metabolic tracer previously developed for positron emission tomography (PET). Twenty-seven patients with severe ischaemic cardiomyopathy (mean left ventricular ejection fraction: 20%±9%) having clinically indicated nitrogen-13 ammonia/FDG PET myocardial viability studies consented to resting, four-view, planar myocardial thallium-201 perfusion and FDG metabolism imaging. The resultant PET and planar perfusion/metabolism images (PPI) were independently assessed for FDG defect size and perfusion/metabolism mismatch, using a four-point scale, in each of four vascular regions: apex, circumflex, left anterior and posterior descending coronary artery territories. Of 108 regions, 106 were evaluable (two not assessed by PET). There was complete agreement in 70% of coronary vascular territories, giving an unweighted kappa score of 0.56. Moreover, in 94% of segments agreement was within one grade. Interestingly, six of the seven differences of more than one grade occurred in the circumflex coronary territory, which was also the only region for which planar positron imaging underestimated FDG defect size. Three of four moderate areas of perfusion/metabolism mismatch seen with PET were also seen on PPI. PPI showed three small regions of mismatch not seen on PET, whilst the reverse occurred with one other small region of mismatch. Thus, for this PET protocol, PPI provides very similar information on the extent of regional FDG uptake and occurrence of mismatch. This suggests that perfusion/FDG imaging using an adequately collimated conventional planar gamma camera may be used instead of a formal PET viability study for the clinical detection of viable myocardium, making this form of metabolic assessment more widely available throughout the community.  相似文献   

11.
Dual-head coincidence gamma camera 18F-fluorodeoxyglucose (FDG) imaging was compared with FDG PET in the detection of breast cancer and axillary lymph node metastasis. METHODS: Both coincidence gamma camera FDG imaging and FDG PET were performed in a cylindrical phantom containing spheres of different sizes and activity ratios (5:1, 10:1 and 15:1) and in 30 women (age range 32-78 y) with suspected breast cancer. Biopsies or mastectomies were performed in all patients. Images were visually assessed, and the count ratio between tumor and normal tissue (T/N ratio) was calculated. RESULTS: In the phantom studies, coincidence gamma camera imaging visualized the smallest sphere (1.0 cm) at a ratio of 15:1 but not at ratios of 5:1 and 10:1. Coincidence gamma camera imaging visualized the other spheres (> or =1.3 cm) at all ratios. PET visualized all spheres at all ratios. In the clinical studies, 22 of 26 breast carcinomas detected by PET were also detected by coincidence gamma camera imaging.. Coincidence gamma camera imaging detected all of the carcinomas > or =2 cm in diameter (n = 10) and 12 of 16 carcinomas <2 cm. In breast carcinomas detected by both PET and coincidence gamma camera imaging, the T/N ratio in non-attenuation-corrected PET (7.12 +/- 7.13) was significantly higher than in coincidence gamma camera imaging (2.90 +/- 1.47, P < 0.005). Four of 8 axillary lymph node metastases detected by PET were detected by coincidence gamma camera imaging. Of 9 axillary lymph node metastases <1.0 cm in diameter, 7 and 3 were detected by PET and coincidence gamma camera imaging, respectively. CONCLUSION: Coincidence gamma camera imaging is useful in detecting breast carcinoma > or =2 cm in diameter but is not reliable for breast carcinoma <2 cm in diameter. Coincidence gamma camera imaging may be useless or even dangerous in the detection of axillary lymph node metastasis.  相似文献   

12.
AIM: To evaluate functional-anatomical imaging with 2-[F]fluoro-2-deoxy-D-glucose (F-FDG) utilizing a dual-head coincidence gamma camera with an integrated X-ray transmission system for attenuation correction, anatomical mapping, and image fusion compared to conventional diagnostics by computed tomography (CT) in non-small cell lung cancer (NSCLC). METHODS: Thirty-five patients with NSCLC underwent FDG imaging of the thoracic area using a dual-head coincidence gamma camera (DHC) with an integrated X-ray transmission system. State-of-the-art CT scans had been performed before. Whole-body dedicated FDG positron emission tomography (PET) was performed immediately prior to DHC. Staging by CT and DHC, and DHC with integrated image fusion (FDHC) were re-evaluated with regard to detectable lesions, correct anatomical diagnoses, and clinical impact. Results of DHC and PET were compared for analysis of limitations of DHC. RESULTS: One hundred and thirteen tumour lesions were identified by CT. DHC detected 128 lesions overall: 102 true positive CT lesions were confirmed, 25 additional lesions were detected which affected staging in eight patients, and one false positive lung lesion did not show up in DHC. Nine CT lesions were missed by DHC (lymph node and lung). PET detected 150 areas of focally enhanced uptake, delivering two false positive results (nuchal muscles, pneumonia). Final evaluation confirmed 148 malignant lesions. Compared to CT, the results of DHC changed staging or treatment in 8/35 patients (23%). Lesion detection by DHC was limited by tumour size and intensity of FDG uptake. Image fusion provided relevant clinical information in 9/35 patients (26%). CONCLUSION: Functional imaging in NSCLC with this dual-head gamma camera is superior to morphological imaging by CT, although inferior to dedicated PET imaging. Combined functional-anatomical imaging has the potential to improve staging and localization procedures before surgery or radiotherapy.  相似文献   

13.
OBJECTIVE: We determined the value of attenuation correction (AC) of myocardial perfusion estimation with (99m)Tc-MIBI SPECT in overweight patients by comparison of uncorrected (filtered back-projection (FBP) and corrected (an iterative algorithm with a measured attenuation coefficients map (FL-AC)) (99m)Tc-MIBI relative uptake to perfusion data obtained in the same patients with NH3 PET. In addition, the impact of attenuation correction for the assessment of myocardial viability with (99m)Tc-MIBI SPECT was determined using FDG PET as the reference method. METHODS: Thirty consecutive overweight patients (BMI=28+/-4) with left ventricular dysfunction underwent a resting (99m)Tc-MIBI SPECT and a PET study (NH3 and FDG). (99m)Tc-MIBI SPECT scans were reconstructed without attenuation correction (FBP) and with attenuation correction (FL-AC). The left ventricle was divided into 16 segments, in which the relative uptake was quantified using circumferential profiles. A relative uptake > or = 60% was considered consistent with viable myocardium for FDG and MIBI. RESULTS: The absolute difference between (99m)Tc-MIBI SPECT and NH3 PET uptakes was less pronounced in the inferior (12+/-10% vs. 17+/-12%, P<0.001), anteroseptal (12+/-11% vs. 16+/-12%, P=0.009) and septal (15+/-12% vs. 18+/-14%, P=0.003) regions (FL-AC vs. FBP, respectively). The sensitivity of MIBI for diagnosing myocardial viability increased from 83 to 100% (P=0.034), without loss in specificity. CONCLUSION: Attenuation correction improves myocardial perfusion estimation by (99m)Tc-MIBI SPECT in the inferior, anteroseptal and septal regions and increases its sensitivity for the diagnosis of myocardial viability.  相似文献   

14.
The aim of this study was to explore the correlations of detectability and the semi-quantification for hot spot imaging with positron emitters in positron emission tomography (PET) and with a positron coincidence detection system (PCD). Phantom study results for the measurement of the lesion-to-background (L/B) ratio ranged from 2.0 to 30.3, and detectability for hot spot lesion of PET and PCD were performed to correspond to clinical conditions. The detectability and semi-quantitative evaluation of hot spots from 4.4 mm to 36.9 mm in diameter were performed from the PET and PCD images. There were strong correlations between the L/B ratios derived from PET and PCD hot spot images and actual L/B ratios; but the L/B ratio derived from PET was higher than that from PCD with a significant difference of 10% to 54.8%. The detectability of hot spot imaging of PCD was lower than that of PET at 64.8% (PCD) versus 77.8% (PET). Even the actual L/B ratio was 8.0, hot spots more than 10.6 mm in diameter could be clearly identified with PCD imaging. The same identification could be achieved with PET imaging even when the actual L/B ratio was 4.0. This detailed investigation indicated that FDG PCD yielded results comparable to FDG PET on visual analysis and semi-quantitative analysis in detecting hot spots in phantoms, but semi-quantitative analysis of the L/B ratio with FDG PCD was inferior to that with FDG PET and the detectability of PCD in smaller hot spots was significantly poor.  相似文献   

15.
AIM: A comparative study of the images obtained with a dual-head coincidence gamma camera with thick NaI crystals (19 mm), a dedicated PET camera with BGO crystals and a conventional gamma camera with thin NaI crystals (9.5 mm) was conducted to clarify the clinical feasibility of a dual-head coincidence gamma camera with thick NaI crystals. METHODS: FDG images of 27 patients with malignant tumors were obtained by means of a dual-head coincidence gamma camera with thick NaI crystal and a dedicated PET camera with BGO crystals. The images of bone scintigraphy in 10 cancer patients obtained with the dual-head coincidence gamma camera were compared with those taken by a conventional dual-head gamma camera with thin NaI crystals. RESULTS: Patient-basis sensitivity in 27 patients with neoplasms and lesion-basis sensitivity of the dual-head coincidence gamma camera and the dedicated PET camera were 74.1% and 85.2% (n.s.), 66.7% and 72.2% (n.s.), respectively. The tumor to background FDG uptake ratio derived from the coincidence gamma camera was significantly lower than that derived from the dedicated PET camera (mean +/- s.d.; 3.48 +/- 3.77 vs. 8.12 +/- 8.92, p < 0.0001), but the tumor to background FDG uptake ratio obtained with both methods correlated well (r = 0.84, p < 0.001). Similar whole body bone scans were obtained with the dual-head coincidence gamma camera and the conventional dual-head gamma camera in all 10 patients. CONCLUSION: These results suggest that the dual-head coincidence gamma camera with thick NaI crystals has potentially high clinical applicability for community hospitals.  相似文献   

16.
Hybrid PET scanners offer the possibility of obtaining myocardial viability information from coincidence imaging of the positron emitter (18)F-FDG and perfusion measurements from a single-photon tracer-potentially simultaneously. This new approach is less costly and more readily available than dedicated PET and offers potential for improved FDG resolution and sensitivity compared with SPECT with 511-keV collimators. Simultaneous imaging of the coincidence and single-photon events offers the further advantages of automatic image registration and reduced imaging time. However, the feasibility of simultaneous coincidence/single-photon imaging or even immediately sequential imaging is unknown. In this study, the potential of using standard low-energy high-resolution (LEHR) collimators with hybrid PET to obtain coincidence and SPECT data was assessed. METHODS: Phantom and human studies were performed to investigate the effect of LEHR collimators on FDG coincidence imaging with a hybrid PET system, the effect of the presence of (99m)Tc during FDG coincidence imaging with LEHR collimators, and the effect of the presence of FDG during (99m)Tc SPECT imaging. RESULTS: FDG images were somewhat degraded (a measure of myocardial nonuniformity increased 10%) with LEHR collimators. With 148 MBq (4 mCi) (99m)Tc present during FDG imaging of a phantom, image quality was maintained and the number of detected coincidences changed by <5%. With (99m)Tc/(18)F whole-body ratios of 7:1, crosstalk from (18)F photons accounted for the majority of counts in the (99m)Tc SPECT images and resulted in severe artifacts. The artifacts were decreased with a simple crosstalk correction scheme but remained problematic. CONCLUSION: (99m)Tc/(18)F ratios of at least 9:1 and state-of-the-art reconstruction and crosstalk correction are likely to be required to perform immediately sequential coincidence/single-photon imaging of the myocardium with clinically useful results. Additional challenges remain before simultaneous imaging of coincidence events and single photons can be realized in practice.  相似文献   

17.
The assessment of myocardial viability has become an important aspect of the diagnostic and prognostic work-up of patients with ischemic cardiomyopathy. Although revascularization may be considered in patients with extensive viable myocardium, patients with predominantly scar tissue should be treated medically or evaluated for heart transplantation. Among the many viability tests, noninvasive assessment of cardiac glucose use (as a marker of viable tissue) with F18-fluorodeoxyglucose (FDG) is considered the most accurate technique to detect viable myocardium. Cardiac FDG uptake has traditionally been imaged with positron emission tomography (PET). Clinical studies have shown that FDG-PET can accurately identify patients with viable myocardium that are likely to benefit from revascularization procedures, in terms of improvement of left ventricular (LV) function, alleviation of heart failure symptoms, and improvement of long-term prognosis. However, the restricted availability of PET equipment cannot meet the increasing demand for viability studies. As a consequence, much effort has been invested over the past years in the development of 511-keV collimators, enabling FDG imaging with single-photon emission computed tomography (SPECT). Because SPECT cameras are widely available, this approach may allow a more widespread use of FDG for the assessment of myocardial viability. Initial studies have directly compared FDG-SPECT with FDG-PET and consistently reported a good agreement for the assessment of myocardial viability between these 2 techniques. Additional studies have shown that FDG-SPECT can also predict improvement of LV function and heart failure symptoms after revascularization. Finally, recent developments, including coincidence imaging and attenuation correction, may further optimize cardiac FDG imaging (for the assessment of viability) without PET systems.  相似文献   

18.
The purpose of this study was to compare the diagnostic accuracy of fluorine-18 fluorodeoxyglucose (FDG) images obtained with (a) a dual-head coincidence gamma camera (DHC) equipped with 5/8-inch-thick NaI(Tl) crystals and parallel slit collimators and (b) a dedicated positron emission tomograph (PET) in a series of 28 patients with known or suspected malignancies. Twenty-eight patients with known or suspected malignancies underwent whole-body FDG PET imaging (Siemens, ECAT 933) after injection of approximately 10 mCi of 18F-FDG. FDG DHC images were then acquired for 30 min over the regions of interest using a dual-head gamma camera (VariCam, Elscint). The images were reconstructed in the normal mode, using photopeak/photopeak, photopeak/Compton, and Compton/photopeak coincidence events. FDG PET imaging found 45 lesions ranging in size from 1 cm to 7 cm in 28 patients. FDG DHC imaging detected 35/45 (78%) of these lesions. Among the ten lesions not seen with FDG DHC imaging, eight were less than 1.5 cm in size, and two were located centrally within the abdomen suffering from marked attenuation effects. The lesions were classified into three categories: thorax (n=24), liver (n=12), and extrahepatic abdominal (n=9). FDG DHC imaging identified 100% of lesions above 1.5 cm in the thorax group and 78% of those below 1.5 cm, for an overall total of 83%. FDG DHC imaging identified 100% of lesions above 1.5 cm, in the liver and 43% of lesions below 1.5 cm, for an overall total of 67%. FDG DHC imaging identified 78% of lesions above 1.5 cm in the extrahepatic abdominal group. There were no lesions below 1.5 cm in this group. FDG coincidence imaging using a dual-head gamma camera detected 90% of lesions greater than 1.5 cm. These data suggest that DHC imaging can be used clinically in well-defined diagnostic situations to differentiate benign from malignant lesions.  相似文献   

19.
18F-Fluorodeoxyglucose positron emission tomography (18FDG PET) is the recognized gold standard for the assessment of myocardial viability, but is not widely available in the UK. FDG imaging on a gamma camera with high-energy collimators (FDG SPECT) has been shown to have an accuracy comparable with that of FDG PET for the assessment of myocardial viability. This study was performed to assess the feasibility of introducing FDG SPECT for myocardial viability at a hospital a considerable distance away from a cyclotron (200 miles). Twenty-three patients, who were being actively considered for revascularization but had demonstrated fixed defects on stress/rest with nitrate tetrofosmin imaging, underwent FDG SPECT. Image quality was acceptable in all patients. Nine out of the 23 patients with defects classed as fixed on tetrofosmin imaging demonstrated viability on FDG SPECT. Six of these nine patients, reported to have some viable myocardium on FDG SPECT, underwent revascularization as a result. This study has demonstrated that FDG SPECT is feasible at a site some distance from a cyclotron.  相似文献   

20.
The purpose of this study was to compare the diagnostic accuracy of fluorine-18 fluorodeoxyglucose (FDG) images obtained with (a) a dual-head coincidence gamma camera (DHC) equipped with 5/8-inch-thick NaI(Tl) crystals and parallel slit collimators and (b) a dedicated positron emission tomograph (PET) in a series of 28 patients with known or suspected malignancies. Twenty-eight patients with known or suspected malignancies underwent whole-body FDG PET imaging (Siemens, ECAT 933) after injection of approximately 10 mCi of 18F-FDG. FDG DHC images were then acquired for 30 min over the regions of interest using a dual-head gamma camera (VariCam, Elscint). The images were reconstructed in the normal mode, using photopeak/photopeak, photopeak/Compton, and Compton/photopeak coincidence events. FDG PET imaging found 45 lesions ranging in size from 1 cm to 7 cm in 28 patients. FDG DHC imaging detected 35/45 (78%) of these lesions. Among the ten lesions not seen with FDG DHC imaging, eight were less than 1.5 cm in size, and two were located centrally within the abdomen suffering from marked attenuation effects. The lesions were classified into three categories: thorax (n=24), liver (n=12), and extrahepatic abdominal (n=9). FDG DHC imaging identified 100% of lesions above 1.5 cm in the thorax group and 78% of those below 1.5 cm, for an overall total of 83%. FDG DHC imaging identified 100% of lesions above 1.5 cm, in the liver and 43% of lesions below 1.5 cm, for an overall total of 67%. FDG DHC imaging identified 78% of lesions above 1.5 cm in the extrahepatic abdominal group. There were no lesions below 1.5 cm in this group. FDG coincidence imaging using a dual-head gamma camera detected 90% of lesions greater than 1.5 cm. These data suggest that DHC imaging can be used clinically in well-defined diagnostic situations to differentiate benign from malignant lesions. Received 6 August and in revised form 27 November 1998  相似文献   