1.

PURPOSE

All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident.

MATERIALS AND METHODS

Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns.

RESULTS

The mean fracture strengths were as follows: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain.

CONCLUSION

The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.  相似文献   

2.

PURPOSE

Marginal fit is a very important factor considering the restoration''s long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system).

MATERIALS AND METHODS

20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test.

RESULTS

The means and standard deviations of the marginal fit were 61.52 ± 2.88 µm for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and 83.15 ± 3.51 µm after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of 62.22 ± 1.78 µm before porcelain veneering and 82.03 ± 1.85 µm after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well.

CONCLUSION

The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.  相似文献   

3.

PURPOSE

This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques).

MATERIALS AND METHODS

Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05).

RESULTS

Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001).

CONCLUSION

Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit.  相似文献   

4.

PURPOSE

This in vitro study aimed to compare the failure load and failure characteristics of two different zirconia framework designs of premolar crowns when subjected to static loading.

MATERIALS AND METHODS

Two types of zirconia frameworks, conventional 0.5 mm even thickness framework design (EV) and 0.8 mm cutback of full contour crown anatomy design (CB), were made for 10 samples each. The veneer porcelain was added on under polycarbonate shell crown made by vacuum of full contour crown to obtain the same total thickness of the experiment crowns. The crowns were cemented onto the Cobalt-Chromium die. The dies were tilted 45 degrees from the vertical plane to obtain the shear force to the cusp when loading. All crowns were loaded at the lingual incline of the buccal cusp until fracture using a universal testing machine with cross-head speed 0.5 mm/min. The load to fracture values (N) was recorded and statistically analyzed by independent sample t-test.

RESULTS

The mean and standard deviations of the failure load were 1,170.1 ± 90.9 N for EV design and 1,450.4 ± 175.7 N for CB design. A significant difference in the compressive failure load was found (P<.05). For the failure characteristic, the EV design was found only cohesive failures within veneering porcelain, while the CB design found more failures through the zirconia framework (8 from 10 samples).

CONCLUSION

There was a significant difference in the failure load between two designs, and the design of the framework influences failure characteristic of zirconia crown.  相似文献   

5.

PURPOSE

To determine whether the fracture strengths and failure types differed between metal and zirconia frameworks veneered with pressable or layering ceramics.

MATERIALS AND METHODS

A phantom molar tooth was prepared and duplicated in 40 cobalt-chromium abutments. Twenty metal (IPS d.SIGN 15, Ivoclar, Vivadent, Schaan, Liechtenstein) and 20 zirconia (IPS e.max ZirCAD, Ivoclar) frameworks were fabricated on the abutments. Each framework group was randomly divided into 2 subgroups according to the veneering material: pressable and layering ceramics (n=10). Forty molar crowns were fabricated, cemented onto the corresponding abutments and then thermocycled (5-55℃, 10,000 cycles). A load was applied in a universal testing machine until a fracture occurred on the crowns. In addition, failure types were examined using a stereomicroscope. Fracture load data were analyzed using one-way ANOVA and Tukey HSD post-hoc tests at a significance level of 0.05.

RESULTS

The highest strength value was seen in metal-pressable (MP) group, whereas zirconia-pressable (ZP) group exhibited the lowest one. Moreover, group MP showed significantly higher fracture loads than group ZP (P=.015) and zirconia-layering (ZL) (P=.038) group. No significant difference in fracture strength was detected between groups MP and ML, and groups ZP and ZL (P>.05). Predominant fracture types were cohesive for metal groups and adhesive for zirconia groups.

CONCLUSION

Fracture strength of a restoration with a metal or a zirconia framework was independent of the veneering techniques. However, the pressing technique over metal frameworks resisted significantly higher fracture loads than zirconia frameworks.  相似文献   

6.

PURPOSE

Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques.

MATERIALS AND METHODS

A 1.2 mm, 360° chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely X™ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (α=0.05). Scanning electron microscope was used to investigate the fractured interface.

RESULTS

Mean fracture load and standard deviation was 4263.8±1110.8 N for Group LT, 5070.8±1016.4 for Group HT and 6242.0±1759.5 N for Group ST. The values of Group ST were significantly higher than those of the other groups.

CONCLUSION

Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.  相似文献   

7.

PURPOSE

This study investigated the effect of amount of thickness reduction on color and translucency of dental monolithic zirconia ceramics.

MATERIALS AND METHODS

One-hundred sixty-five monolithic zirconia specimens (16.3 mm × 16.3 mm × 2.0 mm) were divided into 5 groups (Group I to V) according to the number of A2-coloring liquid applications. Each group was then divided into 11 subgroups by reducing the thickness up to 1.0 mm in 0.1-mm increments (Subgroup 0 to 10, n=3). Colors and spectral distributions were measured according to CIELAB on a reflection spectrophotometer. All measurements were performed on five different areas of each specimen. Color difference (ΔE*ab) and translucency parameter (TP) were calculated. Data were analyzed using one-way ANOVA and multiple comparison Scheffé test (α=.05).

RESULTS

There were significant differences in CIE L* between Subgroup 0 and other subgroups in all groups. CIE a* increased (0.52<R2<0.73), while CIE b* decreased (0.00<R2<0.74) in all groups with increasing thickness reduction. Perceptible color differences (ΔE* ab>3.7) were obtained between Subgroup 0 and other subgroups. TP values generally increased as the thickness reduction increased in all groups (R2>0.89, P<.001).

CONCLUSION

Increasing thickness reduction reduces lightness and increases a reddish, bluish appearance, and translucency of monolithic zirconia ceramics.  相似文献   

8.

PURPOSE

The aim of this study was to evaluate the effect of polishing and glazing on the color and spectral distribution of monolithic zirconia.

MATERIALS AND METHODS

Forty-five monolithic zirconia specimens (16.3 mm × 16.4 mm × 2.0 mm) were fabricated and divided into 5 groups according to the number of A2-coloring liquid applications (Group I to V). Each group was divided into 3 subgroups according to the method of surface treatments (n=3): N: no treatment; P: polishing; G: glazing. Color and spectral distribution of five different areas of each specimen were measured according to CIELAB color space in the reflectance mode relative to the standard illuminant D65 on a reflection spectrophotometer. Data were analyzed using one-way ANOVA followed by Tukey''s HSD test, Pearson correlation and regression analysis (α=.05).

RESULTS

There was a significant difference in CIE L* between Subgroup N and P, and in CIE b* between Subgroup P and G in each group. Spectral reflectance generally decreased in Subgroup P and G in comparison with Subgroup N. Color differences between Subgroup P and G were within the perceptibility threshold (ΔE*ab< 3.7) in most groups. Highly significant correlation was found between CIE b*and each subgroups as the number of coloring liquid applications increased (R2>0.88, P<.001).

CONCLUSION

A perceptible color difference can be detected after polishing of monolithic zirconia. Polishing decreases the lightness, and glazing also decreases the lightness, but increases the yellowness of monolithic zirconia.  相似文献   

9.

Objectives

The aim of this study was to evaluate and compare the translucency of two different all-ceramic systems using Vita Easyshade digital shade matching device in an in vitro model.

Materials and methods

Translucency of lithium disilicate glass-ceramic (IPS e.max Press) and zirconia all-ceramic system (Ceramill ZI) were evaluated and compared. A total of 5 square-shaped specimens with 0.5 mm thickness were fabricated from each ceramic system in A1 shade according to Vitapan Classical shade tab. Specimens were then veneered and glazed with corresponding veneer ceramics recommended by each system manufacturer and the total thickness was set to 1.5 mm. Translucency was evaluated using VITA Easyshade in two stages: before and after veneering and glazing on black and white background. Translucency parameter (TP) was calculated. A one-way ANOVA and Bonferonni tests were used when appropriate (α=0.05).

Results

Lithium disilicate glass-ceramic was significantly more translucent than the zirconia system in both stages (P<0.05). Translucency of all specimens was significantly decreased after veneering and glazing in both all-ceramic systems (P<0.05).

Conclusion

The translucency of two different dental ceramics was significantly influenced by both material and stages of preparation. Within the limitations of the experiment, these results can be valuable and help the clinician to make appropriate esthetic decisions.Key words: tooth color, dental shade-matching device, translucency, glass-ceramics, zirconia  相似文献   

10.

PURPOSE

The purpose of this study was to evaluate and compare the translucency of shaded zirconia all-ceramic systems.

MATERIALS AND METHODS

Translucency of 3 different zirconia all-ceramic systems colored by different techniques was compared with a lithium disilicate glass-ceramic (IPS e.max Press). Square-shaped specimens with 0.5 mm thickness were fabricated from In-Ceram YZ, ICE Zirkon and Katana systems in A1, A2 and A3.5 shades according to Vitapan Classical shade tab (n=11). Specimens were then veneered and glazed with corresponding veneer ceramic recommended by each zirconia system manufacturer and the total thickness was set to 1.5 mm. Translucency measurements were performed with VITA Easyshade Compact spectrophotometer after each stage and translucency parameter was calculated. Data were statistically analyzed with repeated measures ANOVA and Tukey multiple comparison test.

RESULTS

The control group was significantly more translucent than the zirconia systems (P<.05). ICE Zirkon cores showed the least translucency; neither In-Ceram YZ nor Katana systems were superior to each other in terms of translucency. Translucency of all specimens was decreased after veneering, and the translucency rankings were changed.

CONCLUSION

Coloring technique did not have a significant effect on translucency of zirconia cores. Although zirconia systems were less translucent than lithium disilicate glass ceramic, they had partial translucency and there were translucency differences among the zirconia systems. Chroma affected the translucency of precolored zirconia cores.  相似文献   

11.

Objectives

The aim of this study was to evaluate the in vitro behaviour of all-ceramic zirconia molar crowns in regard to different core designs and marginal fit.

Methods

Identically shaped methacrylate molars were prepared according to the ceramic restoration directives resulting in a 1-mm deep circular shoulder preparation. They were embedded in polymethylmethacrylate resin after covering their roots with a polyether layer to simulate periodontal mobility. The crown cores were made of yttria-stabilized zirconia veneered with a corresponding veneering ceramic. The crowns were divided into 5 groups (n = 8) which differed in core design and cement gap thickness: #1: simple core, 40 μm cement; #2: core with minimal occlusal support, 40 μm cement; #3: core with optimized cusp support, 40 μm cement; #4: core with optimized cusp support, 30 μm cement; #5: core with optimized cusp support, 10 μm cement. All crowns were cemented with zinc oxide phosphate cement and thermo mechanically loaded (1.2 × 106 × 50 N; 6000 × 5 °C/55 °C) with identical metal ceramic restorations as antagonists. Crown failures were monitored and described. Area and direction of the chipping failures of the veneering ceramic were documented by means of scanning electron micrographs.

Results

All core designs showed chipping during chewing simulation with different numbers (defect areas). #1: 6 chippings (8.1 mm2); #2: 2 chippings (3.5 mm2); #3: 2 chippings (2.1 mm2); #4: 3 chippings (5.7 mm2); #5: 3 chippings (7.3 mm2).

Conclusions

An optimized core design reduced number and surface area of occurring chippings. A variation of the gap thickness showed no significant influence on the in vitro performance.  相似文献   

12.

PURPOSE

This study evaluated marginal fit of glass infiltrated alumina cores fabricated using two techniques and their marginal stability after firing cycles of veneering porcelain.

MATERIALS AND METHODS

Fifteen standardized all-ceramic crowns were fabricated on a metal die using each technique: slip cast technique of VITA In-Ceram sprint Alumina (Group A as control) and plastic foil matrix technique of Turkom-Cera fused alumina core system (Group B). Copings were compared between groups and within groups at coping stage and after firing each layer of veneering porcelain. A device was used to standardize seating of copings on the metal die and positioning of the specimens under the microscope after each stage of fabrication. The specimens were not cemented and marginal gap was measured using an image analyzing software (Imagepro Express) on the photographs captured under an optical microscope. Two tailed unpaired ''t test'' was used to compare marginal gaps in two groups and one way ANOVA was used to analyze marginal distortion within each group at 95% confidence interval.

RESULTS

The marginal gap was smaller at the coping stage in group B (60 + 30 µm) than group A (81 + 21 µm) with statistical significance. After firing of veneering porcelain the difference was insignificant. At the final stage, both groups exhibited lower mean marginal gaps than at the initial coping stage with the difference of 11.75 µm for group A and 11.94 µm for group B, but it was statistically insignificant due to high value of standard deviation.

CONCLUSION

Within the limitations of this study, it was concluded that both techniques produced copings with comparable and acceptable marginal fit and marginal stability on firing veneering porcelain.  相似文献   

13.

Objective:

This study evaluated the fracture strengths of endodontically treated teeth restored with prefabricated posts with different post lengths.

Material and methods:

Thirty freshly extracted canines were endodontically treated. They were randomly divided into groups of 10 teeth and prepared according to 3 experimental protocols, as follows; Group 1/3 PP: teeth restored with prefabricated post and composite resin core (Z250) with post length of 5.0mm; Group 1/2 PP and Group 2/3 PP: teeth restored with prefabricated post and composite resin core (Z250) with different combinations of post length of 7.5mm and 10mm, respectively. All teeth were restored with full metal crowns. The fracture resistance (N) was measured in a universal testing machine (crosshead speed 0.5mm/min) at 45 degrees to the tooth long axis until failure. Data were analyzed by one-way analysis of variance (α=.05).

Results:

The one-way analysis of variance demonstrated no significant difference among the different post lengths (P>.05) (Groups 1/3 PP = 405.4 N, 1/2 PP = 395.6 N, 2/3 PP = 393.8 N). Failures occurred mainly due to core fracture.

Conclusion:

The results of this study showed that an increased post length in teeth restored with prefabricated posts did not significantly increase the fracture resistance of endodontically treated teeth.  相似文献   

14.

PURPOSE

The purpose of this study was to assess the impact of the core materials, thickness and fabrication methods of veneering porcelain on prosthesis fracture in the porcelain fused to metal and the porcelain veneered zirconia.

MATERIALS AND METHODS

Forty nickel-chrome alloy cores and 40 zirconia cores were made. Half of each core group was 0.5 mm-in thickness and the other half was 1.0 mm-in thickness. Thus, there were four groups with 20 cores/group. Each group was divided into two subgroups with two different veneering methods (conventional powder/liquid layering technique and the heat-pressing technique). Tensile strength was measured using the biaxial flexural strength test based on the ISO standard 6872:2008 and Weibull analysis was conducted. Factors influencing fracture strength were analyzed through three-way ANOVA (α≤.05) and the influence of core thickness and veneering method in each core materials was assessed using two-way ANOVA (α≤.05).

RESULTS

The biaxial flexural strength test showed that the fabrication method of veneering porcelain has the largest impact on the fracture strength followed by the core thickness and the core material. In the metal groups, both the core thickness and the fabrication method of the veneering porcelain significantly influenced on the fracture strength, while only the fabrication method affected the fracture strength in the zirconia groups.

CONCLUSION

The fabrication method is more influential to the strength of a prosthesis compared to the core character determined by material and thickness of the core.  相似文献   

15.

PURPOSE

Zirconia has been used in clinical dentistry for approximately a decade, and there have been several reports regarding the clinical performance and survival rates of zirconia-based restorations. The aim of this article was to review the literatures published from 2000 to 2010 regarding the clinical performance and the causes of failure of zirconia fixed partial dentures (FPDs).

MATERIALS AND METHODS

An electronic search of English peer-reviewed dental literatures was performed through PubMed to obtain all the clinical studies focused on the performance of the zirconia FPDs. The electronic search was supplemented by manual searching through the references of the selected articles for possible inclusion of some articles. Randomized controlled clinical trials, longitudinal prospective and retrospective cohort studies were the focuses of this review. Articles that did not focus on the restoration of teeth using zirconia-based restorations were excluded from this review.

RESULTS

There have been three studies for the study of zirconia single crowns. The clinical outcome was satisfactory (acceptable) according to the CDA evaluation. There have been 14 studies for the study of zirconia FPDs. The survival rates of zirconia anterior and posterior FPDs ranged between 73.9% - 100% after 2 - 5 years. The causes of failure were veneer fracture, ceramic core fracture, abutment tooth fracture, secondary caries, and restoration dislodgment.

CONCLUSION

The overall performance of zirconia FPDs was satisfactory according to either USPHS criteria or CDA evaluations. Fracture resistance of core and veneering ceramics, bonding between core and veneering materials, and marginal discrepancy of zirconia-based restorations were discussed as the causes of failure. Because of its repeated occurrence in many studies, future researches are essentially required to clarify this problem and to reduce the fracture incident.  相似文献   

16.

Statement of problem

In some clinical conditions minimally invasive complete crown tooth preparations are indicated. This is especially true when gross removal of tooth structure would weaken the remaining tooth or violate the vitality of the dental pulp.

Objective

The purpose of this study was to investigate the influence of (1) exposed lingual zirconia with veneered zirconia crowns, and (2) reduced lingual thickness of monolithic lithium disilicate crowns on the fracture resistance of the crowns after cyclic loading. Metal-ceramic crowns with exposed lingual metal served as controls.

Materials and methods

Twenty-four maxillary central incisor crowns were fabricated in identical shape on metal testing dies in 3 groups: metal-ceramic crowns (MC, n = 8), veneered zirconia crowns (VZ, n = 8), and monolithic lithium disilicate crowns (MO, n = 8). A conservative preparation design with 0.75 mm lingual clearance was used for each crown system. All crowns were cemented to their corresponding crown preparations with self-adhesive resin cement (Multilink Automix). The crowns were subjected to 1000 cycles of thermal cycling, then cyclic loading of 111 N by means of a stainless steel ball, and 50,000 cycles of loading were applied for the fatigue test. Fatigue loading was followed by a continuously increasing compressive load, at a crosshead speed of 1 mm/min until failure. The compressive load (N) required to cause failure was recorded. Means were calculated and analyzed with one-way ANOVA and the Tukey HSD test (α = .05).

Results

There was a significant difference between MO vs. MC (P = .0001), MO vs. VZ (P = .0001), and VZ vs. MC (P = .012).

Conclusions

There was a significant difference in the mean fracture resistance of MC, VZ, and MO crowns in this in vitro study. The MC group recorded the highest mean fracture strength.  相似文献   

17.

PURPOSE

This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear.

MATERIALS AND METHODS

There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) group, and the monolithic zirconia (Zirconia) group. Ten flat crown specimens were prepared per group; opposing teeth were prepared using primary canines. A wear test was conducted over 100,000 chewing cycles using a dual-axis chewing simulator and a 50 N masticating force, and wear losses of antagonistic teeth and restorative materials were calculated using a three-dimensional profiling system and an electronic scale, respectively. Statistical significance was determined using One-way ANOVA and Tukey''s test (P<.05).

RESULTS

The Leucite group (2.670±1.471 mm3) showed the greatest amount of antagonist tooth wear, followed by in decreasing order by the Lithium (2.042±0.696 mm3), Zirconia (1.426±0.477 mm3), and Steel groups (0.397±0.192 mm3). Mean volume losses in the Leucite and Lithium groups were significantly greater than in the Steel group (P<.05). No significant difference was observed between mean volume losses in the Zirconia and Steel groups (P>.05).

CONCLUSION

Leucite glass-ceramic and lithium disilicate glass-ceramic cause more primary tooth wear than stainless steel or zirconia.  相似文献   

18.

Objective

This study investigated the durability of repaired all-ceramic crowns after cyclic loading.

Material and methods

Eighty In-ceram zirconia crowns were fabricated to restore prepared maxillary premolars. Resin cement was used for cementation of crowns. Palatal cusps were removed to simulate fracture of veneering porcelain and divided into 4 groups (n = 20). Fracture site was treated before repair as follows: roughening with diamond bur, (DB); air abrasion using 50 µm Al2O3, (AA) and silica coating using Cojet system followed by silane application, (SC). Control group (CG) 20 specimens were left without fracture. Palatal cusps were repaired using composite resin. Specimens were stored in water bath at 37°C for one week. Ten specimens of each group were subjected to cyclic loading. Fracture load (N) was recorded for each specimen using a universal testing machine. Two-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) test (α=.05) were used for statistical analysis.

Results

There was statistically significant difference between control and tested groups, (p<0.001). Post Hoc analysis with the Tukey HSD test showed that cyclic loading fatigue significantly decreased means fracture load of control and test groups as follows (CG, 950.4±62.6 / 872.3±87.4, P = 0.0004), (DB, 624.2 ±38 / 425.5± 31.7, P <.001), (AA, 711.5 ±15.5 / 490 ± 25.2, p <0.001) and (SC, 788.7 ± 18.1 / 610.2 ± 25.2, P <.001), while silica coating and silane application significantly increased fracture load of repaired crowns (p<0.05).

Conclusion

Repair of fractured Inceram zirconia crowns after chairside treatment of the fracture site by silica coating and silane application could improve longevity of repaired In-ceram zirconia crowns.  相似文献   

19.

Objective

This study investigated the effect of different ferrule heights on endodontically treated premolars.

Materials and Methods

Fifty sound mandibular first premolars were endodontically treated and then restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with self-polymerized resin cement (Multilink, Ivoclar Vivadent) while the coronal section was restored with hybrid composite core build-up material (Tetric Ceram, Ivoclar-Vivadent), which received all-ceramic crown. Different ferrule heights were investigated: 1-mm circumferential ferrule without post and core (group 1 used as control), a circumferential 1-mm ferrule (group 2), non-uniform ferrule 2-mm buccally and 1-mm lingually (group 3), non-uniform ferrule 3-mm buccally and 2-mm lingually (group 4), and finally no ferrule preparation (group 5). The fracture load and failure pattern of the tested groups were investigated by applying axial load to the ceramic crowns (n=10). Data were analyzed statistically by one-way ANOVA and Tukey’s post-hoc test was used for pair-wise comparisons (α=0.05).

Results

There were no significant differences among the failure load of all tested groups (P<0.780). The control group had the lowest fracture resistance (891.43±202.22 N) and the highest catastrophic failure rate (P<0.05). Compared to the control group, the use of fiber post reduced the percentage of catastrophic failure while increasing the ferrule height did not influence the fracture resistance of the restored specimens.

Conclusions

Within the limitations of this study, increasing the ferrule length did not influence the fracture resistance of endodontically treated teeth restored with glass ceramic crowns. Insertion of a fiber post could reduce the percentage of catastrophic failure of these restorations under function.  相似文献   

20.

PURPOSE

The aim of this study was to evaluate the biaxial flexural strength (BFS) of one zirconia-based ceramic used with various veneering ceramics.

MATERIALS AND METHODS

Zirconia core material (Katana) and five veneering ceramics (Cerabien ZR; CZR, Lava Ceram; LV, Cercon Ceram Kiss; CC, IPS e.max Ceram; EM and VITA VM9; VT) were selected. Using the powder/liquid layering technique, bilayered disk specimens (diameter: 12.50 mm, thickness: 1.50 mm) were prepared to follow ISO standard 6872:2008 into five groups according to veneering ceramics as follows; Katana zirconia veneering with CZR (K/CZR), Katana zirconia veneering with LV (K/LV), Katana zirconia veneering with CC (K/CC), Katana zirconia veneering with EM (K/EM) and Katana zirconia veneering with VT (K/VT). After 20,000 thermocycling, load tests were conducted using a universal testing machine (Instron). The BFS were calculated and analyzed with one-way ANOVA and Tukey HSD (α=0.05). The Weibull analysis was performed for reliability of strength. The mode of fracture and fractured surface were observed by SEM.

RESULTS

It showed that K/CC had significantly the highest BFS, followed by K/LV. BFS of K/CZR, K/EM and K/VT were not significantly different from each other, but were significantly lower than the other two groups. Weibull distribution reported the same trend of reliability as the BFS results.

CONCLUSION

From the result of this study, the BFS of the bilayered zirconia/veneer composite did not only depend on the Young''s modulus value of the materials. Further studies regarding interfacial strength and sintering factors are necessary to achieve the optimal strength.  相似文献   