首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In order to develop sensitive assays for detecting measles antibodies in oral fluid specimens, we have produced recombinant measles virus nucleoprotein (rMVN) in a yeast expression system and prepared monoclonal antibodies to the protein. Measles nucleoprotein gene from the Schwarz vaccine strain was cloned into a yeast expression vector, pFX7 under the control of the hybrid GAL10-PYK1 promoter. High levels of rMVN (20 mg/litre of yeast culture) were generated. Electron microscopy showed that the purified rMVN assembled into typical herring-bone structures. Monoclonal antibodies produced to the rMVN also reacted with native measles virus N in immunofluorescence tests. The purified rMVN and a monoclonal antibody to the rMVN conjugated to horseradish peroxidase were used to develop a measles specific IgM capture EIA (MACEIA) in both serum and oral fluid specimens. Evaluations of the MACEIA were performed by testing a) serum samples (n=80) and b) paired oral fluid/serum samples from measles cases (n=50, representing 16 cases) and oral fluids from controls with non-measles rash (n=59, representing 48 cases). The samples were also tested for measles IgM, using a reference radioimmunoassay (MACRIA). The sensitivity and specificity of the MACEIA compared with MACRIA for a) the serum samples were 100 and 96.6% respectively and b) for paired serum/oral fluids samples 100 and 100%, respectively.  相似文献   

2.
An antibody capture haemadherence test (MACHAT) for detecting measles-specific IgM is described. The assay is based on the antibody capture principle with rhesus monkey erythrocytes as detector system in place of labelled antisera. MACHAT was compared with a commercial indirect enzyme immunoassay (EIA) for measles-specific IgM using 382 sera from patients notified as measles. There was good agreement between the two tests; 106 sera were found to contain measles IgM by both tests, 7 further sera were positive only in the commercial EIA and 9 only in MACHAT. One sera gave an equivocal result in MACHAT and another in the commercial EIA. Twelve of the 18 sera with discrepant results were also tested by MACRIA; in 7 MACRIA gave the same results as MACHAT, in 3 the MACRIA results agreed with the commercial test and in 2 the MACRIA results were equivocal. Specificity was established by a lack of MACHAT reactivity in sera collected from blood donors (n = 83) and from cases of recent rubella, dengue and parvovirus B19 infection (n = 51). The MACHAT is a simple, cheap test that can be read by eye and is suitable for measles surveillance programmes in the developing world.  相似文献   

3.
BACKGROUND: An IgM antibody capture radioimmunoassay (MACRIA) has been used in the UK Reference Laboratory for the detection of mumps specific IgM antibodies in oral fluid and serum samples. The method has proved both sensitive and specific and has been used for the surveillance of mumps since 1994. The use of radioactive labels has restricted the use of MACRIA to specialised laboratories and alternative, non-isotopic, sensitive assays capable of detecting the low levels of specific antibodies in oral fluid have not been available. Recently, a novel mumps specific IgM capture enzyme immunoassay (MACEIA) utilising recombinant mumps nucleoprotein (rMuVN) and monoclonal antibodies to the nucleoprotein, produced by Microimmune Limited, has been developed for use with both serum and oral fluid samples. OBJECTIVES: In this study, we have evaluated the performance of the Microimmune MACEIA for both serum and oral fluid against specimens tested by MACRIA. STUDY DESIGN: The panel consisted of matched serum and oral fluid specimens from 137 cases of suspected mumps received in the Virus Reference Department for routine investigation from March 2003 to October 2004. RESULTS: The sensitivity, specificity, positive and negative predictive value of the Microimmune MACEIA on serum samples compared to MACRIA were 98.8%, 100.0%, 100.0% and 98.5%, respectively. The sensitivity, specificity, positive and negative predictive value of the Microimmune MACEIA on oral fluid samples compared to Microimmune MACEIA and MACRIA consensus results on the paired serum samples were 90.3%, 97.6%, 98.3% and 87.1%, respectively. CONCLUSIONS: The Microimmune MACEIA was found to be a rapid, sensitive and specific alternative to MACRIA for the detection of mumps specific IgM in sera and oral fluids.  相似文献   

4.
Antibody capture radioimmunoassays were developed for detecting virus specific IgM (MAC-RIA) and IgG (GACRIA) to measles, mumps, and rubella and used to investigate saliva as an alternative specimen to serum for diagnosis. Saliva was collected from 63 patients with measles, 19 with mumps, and 150 with rubella, which were all clinically diagnosed and serologically confirmed. Virus specific IgM was detected in 92% of measles, 75% of mumps, and 100% of rubella saliva samples collected during the first week of illness. Between 1 and 5 weeks after onset virus specific IgM was detected in 100% of saliva specimens. After the 5th week the proportion of reactive specimens declined. The specificity of the MACRIA tests was established by testing saliva samples collected from blood donors for measles (88), mumps (88), and rubella IgM (91). All of the saliva specimens tested for measles and rubella specific IgM were unreactive, 1/88 specimens tested for mumps specific IgM contained significant reactivity. Saliva specimens collected from acute cases of MMR were tested in all 3 MACRIAs. A small proportion of saliva samples contained detectable IgM of more than one virus infection. Rubella and measles specific IgG was detected in the saliva of all cases from the 4th or 5th day of illness, respectively. Detection of mumps specific IgG was less successful. We have demonstrated that virus specific IgM can be reliably detected in saliva samples collected from acute cases of measles, mumps, and rubella and identified 1–5 weeks after onset of illness as the optimum time for collection of samples. © 1993 Wiley-Liss, Inc.  相似文献   

5.
Serum specimens collected from patients convalescing from acute measles or mumps infections, other viral infections, or rheumatoid arthritis and from blood donors were tested in indirect and reverse assays for measles and mumps immunoglobulin M (IgM) antibodies. All the samples from patients convalescing from acute mumps and measles infections gave positive IgM results in both tests. However, 6% of sera from patients recovering from other viral infections, 68.4% of sera from patients with rheumatoid arthritis, and 5.6% of sera from normal blood donors gave false-positive results by the indirect measles IgM enzyme immunoassay (EIA). By the indirect mumps IgM EIA, 9% of sera from other viral infections, 70.1% of sera from patients with rheumatoid arthritis, and 5.6% of sera from normal blood donors gave false-positive reactions. The reverse test system for measles IgM gave false-positive results in 1.5% of sera from the group with other viral infections, and the reverse mumps EIA gave false-positive results in 0.9% of the patients. Other sera groups did not react in either measles or mumps reverse IgM assays. The results indicated that although nonspecific reactions are frequent in indirect IgM tests for viral antibodies, such reactions are rarely encountered when reverse IgM EIA tests are employed.  相似文献   

6.
Three types of mumps virus antigen have been prepared: virion antigen (MV); soluble nucleoprotein (NP) antigen; envelope glycoprotein (eGp) antigen. These antigens were coupled directly with horse-raddish peroxidase and tested by IgM-capture technique against selected human sera. The advantage of the suggested design, in addition to general superiority of the IgM-capture systems, lies in its selectivity achieved by introducing a monoclonal antibody for IgM binding and in time saving due to the use of labelled antigen without the loss of sensitivity and specificity. The assay fulfils the criteria for quick viral diagnostic. Our first experience on application of the labelled antigens in enzyme immunoassay (EIA) is described.  相似文献   

7.
IgM antibody capture radioimmunoassay (MACRIA) and enzyme immunoassay (MACEIA) were compared with immunofluorescence (IF) for detecting specific IgM antibody in 99 sera from 76 infants with confirmed congenital rubella, and 61 sera from a comparative group of 59 infants who had miscellaneous abnormalities but in whom congenital rubella was not confirmed.All of 35 specimens collected from confirmed cases within 12 weeks of birth were positive by all three methods and all but one of 17 specimens collected after the age of 18 months were uniformly negative. At intermediate ages discrepancies occurred in 18 specimens, of which eight were positive and 10 negative by IF. Three of these 18 specimens were negative by both antibody capture procedures but showed weak fluorescence; the other 15 were negative by MACEIA, but positive by MACRIA which appears to be the more sensitive of the antibody capture methods. Sera from five infants in the comparative group were clearly positive by all three methods. These five infants were probably congenitally infected with rubella. Sera from the other 54 infants were negative, except for one that gave a weakly positive result by MACRIA alone.Antibody capture procedures offer several advantages over previous methods for detecting IgM antibody. Although MACRIA was found to be slightly more sensitive than MACEIA, the greater stability of the enzyme label, together with the possibility of both visual and quantitative assessment, could make MACEIA the method of choice for detecting rubella-specific IgM.  相似文献   

8.
We have established two enzyme-linked immunosorbent assays (ELISAs) for detection of mumps IgM antibody, i.e., indirect IgM ELISA and IgM capture ELISA, for serodiagnosis of recent mumps infection. In the latter method, peroxidase-conjugated monoclonal antibody to mumps virus was employed. Both methods detected mumps antibody of IgM class only in serum fractions separated by centrifugation through a sucrose density gradient. Optical density values given by both ELISAs were correlated for most sera examined. Indirect IgM ELISA, however, gave a false positive reaction for sera containing both rheumatoid factor and mumps IgG antibody, while giving a false negative reaction for sera containing high titers of mumps IgG antibody. This technique was, therefore, less reliable than IgM capture ELISA. IgM antibody detectable by IgM capture ELISA was present in all patients with mumps by the fifth day of illness and persisted for up to 3 mth in most and up to 5 mth in same cases.  相似文献   

9.
A total of 468 sera were selected for the evaluation of the Public Health Laboratory Service's IgM antibody capture enzyme linked immunosorbent assay kit (MACELISA) for detecting rubella specific IgM. The results obtained were compared with those obtained by IgM antibody capture radioimmunoassay (MACRIA). Sera from patients with primary postnatal rubella, congenital rubella, remote rubella, infectious mononucleosis, and recent infection with other agents were included, in addition to sera taken after rubella immunisation and sera containing rheumatoid factor and rubella specific IgG antibody. The assay exhibited a similar ability and comparable specificity to MACRIA for detecting rubella specific IgM antibody. The Public Health Laboratory Service MACELISA can be recommended if, as for all assays that detect rubella specific IgM, all the available clinical and serological data are taken into account when the results are interpreted.  相似文献   

10.
We compared the use of serum and filter paper blood spots as specimen sources for the detection of measles- and rubella-specific IgM and IgG. We collected capillary blood into microtainer tubes and onto filter paper spots from 60 children and 60 healthy adults. The blood was collected from 12-15-month-old children approximately 3 weeks after primary vaccination with measles, mumps, rubella vaccine, and the sample-pairs were tested for measles-specific IgM and IgG antibodies by using a capture antibody EIA and an indirect EIA, respectively. We tested sample-pairs from a subset of participants for rubella- specific IgM and IgG antibodies by using commercially available capture IgM (Captia) and indirect IgG (Wampole) assays. The concordance of results from serum and filter paper blood spots was high for all assays: 98% for measles IgM, 93% for measles IgG, 94% for rubella IgM, and 93% for rubella IgG, and increased to between 96-100% for all four assays when indeterminate samples were excluded. The correlation coefficients for EIA signals were 0.99 and 0.77 for measles IgM and IgG, respectively, and 0.92 and 0.94 for rubella IgM and IgG, respectively. The cut-off values used for filter paper samples were the same as those used for serum samples for all tests except for the rubella IgM assay. The use of filter paper blood spots is a promising future option for the detection of measles- and rubella-specific antibodies.  相似文献   

11.
12.
13.
A new M-antibody capture ELISA for the detection of specific IgM against parvovirus B19 is described. The test uses a monoclonal anti-fluorescein isothiocyanate (FITC) antibody conjugated to horseradish peroxidase to amplify the positive reactions. Serum samples (N = 823) submitted for B19 IgM assay were tested in parallel in the new ELISA and the standard B19 M-antibody capture radioimmunoassay (MACRIA) test. By both tests B19 IgM was detected in 38 (4.6%) samples, and not detected in 771 (94%) samples. One sample was positive in the ELISA test but negative in the RIA and of the 13 sera giving 'equivocal' results in the MACRIA, 6 were positive and 7 negative. If the RIA equivocal results were excluded, the ELISA showed 100% (38/38) sensitivity and 99.9% (771/772) specificity compared to the MACRIA test. The B19 IgM ELISA is a sensitive and specific test with better discrimination between anti B19 IgM positive and negative specimens than MACRIA.  相似文献   

14.
A capture enzyme-linked immunosorbent assay (ELISA) for detection of virus-specific immunoglobulin M (IgM) antibody was developed which used a panel of labeled monoclonal antibodies to rubella virus hemagglutinin. The rapidity of the test system was increased by using, after 1-h incubation of the test serum, a second 1-h incubation of the serum with a mixture of viral antigen and labeled monoclonal antibody. The new assay was tested for specificity on 371 human sera from people without any recent contact with rubella virus; of these, 66 were sera selected from people with rheumatoid factor or IgM antibody to human cytomegalovirus, Epstein-Barr virus, or other viruses. In parallel, the new assay was performed on 191 sera from patients having recent contact with rubella virus. Results were compared with those obtained by an indirect ELISA method on IgM serum fractions, using purified rubella virus as a solid phase. Of the 371 sera tested for specificity, 5 (1.3%) gave false-positive results with indirect ELISA (1 rheumatoid factor, 2 heterophil antibody, and 2 human cytomegalovirus sera positive for IgM), and none were false-positive with the capture assay. Two sera from a patient with primary cytomegalovirus infection, which were positive for rubella IgM antibody with both methods and were initially interpreted as false-positive, were finally considered to be true-positive, since they were reactive only in the presence of IgM antibody and viral antigen. Of the 191 sera from 92 patients (84 patients with acute rubella, four newborns from mothers with rubella during pregnancy, and four vaccinees), 136 (71.2%) were found to be positive for IgM by direct ELISA, and 128 (67.0%) were positive by capture ELISA; 12 sera drawn during the first 2 days of disease, or at least 40 days after onset (or after vaccination), were detected only by indirect ELISA, and 4 sera were detected only by capture ELISA. Thus, specificity and sensitivity, respectively, were 100 and 91.4% for capture ELISA and 98.6 and 97.1% for indirect ELISA. However, when the number of patients was considered, 86 were detected as IgM positive by indirect ELISA, and 87 were detected positive by capture ELISA. The overall agreement between the two assays was 96.2%. Capture ELISA using monoclonal antibody appears preferable over indirect ELISA on IgM serum fractions because of its higher specificity and shorter time for test performance; furthermore, there is no need for serum fractionation or virus purification for the capture ELISA.  相似文献   

15.
A direct antibody capture enzyme immunoassay (EIA) for the detection of rubella-specific immunoglobulin M (IgM) antibody was developed. Polystyrene microtiter strips coated with rabbit anti-human IgM were used as solid phase, and a semipurified rubella antigen labeled with horseradish peroxidase was used as indicator. By testing a panel of 238 serum specimens (not including sera from newborns with congenital rubella), the direct EIA was compared with the indirect EIA used routinely in our diagnostic unit and with a commercial IgM capture EIA (RubEnz M II) that employs a horseradish peroxidase-labeled anti-rubella monoclonal antibody as indicator. Overall agreement of direct EIA with indirect EIA and RubEnz M II was 95%, whereas agreement between direct and indirect EIA was 96.2%, and agreement between direct EIA and RubEnz M II was 97.8%. Sensitivity of the direct assay was higher than that of the indirect EIA and similar to that of the RubEnz M II assay. Specific IgM antibody could always be detected in serum specimens taken from patients with primary acute rubella infection between days 4 and 56 after the onset of rash. The assay was highly specific, and it was not affected either by rheumatoid factor or by high levels of specific IgG in sera. Another important advantage that the direct EIA has over the indirect EIA is that it requires 10 to 20 times less antigen per serum specimen tested.  相似文献   

16.
One-hundred and twenty-seven sera were tested to determine whether a primary infection could be identified by a determination of the class of antibody (IgM) detected in serum collected in the period after a viral infection.Serum was collected from patients with a history of measles (18 cases), rubella (24 cases), mumps (12 cases), andM. parinfluenzae type 3 infections (9 cases).The results of the serological assays are compared with clinical observations and the limitations of the methods under consideration are discussed.  相似文献   

17.
Monoclonal antibodies to the hemagglutinin protein, fusion protein, phosphoprotein, matrix protein, and nucleoprotein of measles virus were evaluated as detector antibodies in capture enzyme immunoassays (EIAs) for the detection of specific serum immunoglobulin G (IgG), IgA, and IgM antibodies to measles virus. A pool of monoclonal antibodies to hemagglutinin protein and nucleoprotein proved optimal and was further evaluated. Specific IgM was detected in 97% of adolescents with clinical measles, 97% of infants 3 weeks postvaccination, and less than 1% of normal serum specimens. Specific IgA antibodies were found in 97% of adolescents with clinical measles, 97% of infants 3 weeks postvaccination, and less than 1% of normal serum specimens. Specific IgA antibodies were found in 97% of clinical measles cases and vaccinees, in 26% of healthy persons, and in 36% of infants 8 months postvaccination; consequently, IgA antibodies were not a useful indicator of recent measles infection. A significant increase in IgG antibodies between paired specimens was detected in 92% of clinical cases and all vaccinees. Only 59% of infant specimens had persistent IgG antibodies as detected by capture EIA at 8 months postvaccination, whereas all specimens had antibodies as detected by hemagglutination inhibition and plaque neutralization. An alternative indirect EIA, in which antigen was directly absorbed to the solid phase, was more sensitive than the capture design, detecting IgG antibodies in all infants postvaccination. When standardized with a microneutralization assay for the detection of persistent antibodies, the indirect IgG EIA gave predictive values for positive and negative tests exceeding 90%. Our capture IgM and indirect IgG EIAs provide a practical combination of serologic tests for the determination of acute measles virus infection and past exposure to measles virus or vaccine, respectively.  相似文献   

18.
Seroprevalence studies on measles, mumps, and rubella immunoglobulin G (IgG) antibodies after the implementation of the measles-mumps-rubella (MMR) vaccine are lacking in Kuwait. This study is an age-stratified serological study to assess the herd immunity to measles, mumps, and rubella among the young Kuwaiti population to evaluate the effectiveness of the MMR vaccine. IgG antibody titers to mumps, measles, and rubella were determined with commercial immune-assay in serum samples of 1000 Kuwaitis aged 5 to 20 years. The highest level of seropositivity was to measles (94.6%), which was significantly higher in females than in males. The highest seronegativity was for mumps (29%). The percentage of the young Kuwaiti population who were serologically positive for all the components of the MMR vaccine was 47%, and 2% of the individuals were without any protective antibodies to measles, mumps, and rubella. Females aged 5 to 10 years were best protected to rubella; however, seronegativity in 8.2% of 11- to 20-year-old females makes them vulnerable to rubella virus infection and congenital complications during pregnancy. The study provided insight into the effect of the MMR vaccine on seroprevalence of antibodies against measles, mumps, and rubella in Kuwait, which will contribute to the global knowledge base of vaccine coverage and help to inform elimination strategies. The findings strengthen the need for a third dose of MMR vaccine and catch-up campaigns for the young Kuwaiti population to increase vaccination coverage and prevent waning immunity, especially among those who received only one dose of the vaccine during childhood.  相似文献   

19.
In this study, the seroprevalences of measles, mumps, and rubella antibodies in infants were determined to assess the immunization strategy and control measures for these infectious diseases. Serum samples from infants < 1 year of age and their mothers were collected to measure the concentrations of specific IgG antibodies to measles, mumps, and rubella by enzyme-linked immunosorbent assay. For selected infant serum samples, measles-specific neutralizing antibody levels were determined by using the plaque reduction neutralization test. The sera from 295 of infants and 80 of their mothers were analyzed. No infants had past measles, mumps, or rubella infections. Almost all infants < 2 months of age were positive for measles and rubella IgG antibodies. However, seroprevalence of measles and rubella antibodies decreased with age, and measles IgG and rubella IgG were barely detectable after 4 months of age. The seroprevalence of mumps antibodies was lower than that of measles and rubella antibodies in infants ≤ 4 months old, and mumps IgG was barely detectable after 2 months of age. The seropositivity of measles-specific neutralizing antibody was 63.6% in infants aged 2 months and undetectable in infants ≥ 6 months old. Because the seropositivity rates of measles, mumps, and rubella antibodies were low after the first few months of age in Korean infants, active immunization with vaccines is strongly recommended for infants aged 6–11 months when measles is epidemic. Timely administration of the first dose of measles-mumps-rubella vaccine at 12 months of age should be encouraged in non-epidemic situations.  相似文献   

20.
Hepatitis A virus (HAV) antigens from two tissue culture sources were compared with that from the faeces of infected marmosets to determine whether the former were satisfactory substitutes. Sera from 313 healthy blood donors and 417 patients with various clinical conditions were tested for IgM class antibody to HAV (anti-HAV IgM) using an IgM antibody capture assay (MACRIA) with each of the 3 antigens.Forty-eight specimens, all from cases of acute hepatitis, were positive in MACRIA with all 3 antigens. Only 2 of the 313 blood donors' sera reacted at all. These reactions were weak and did not arise with all antigens. Weakly reactive specimens were also found in 3 out of the 13 clinical categories. Overall 12 weak reactions arose with the faecal antigen and 8 and 7 with the two tissue culture antigens. Rheumatoid factor (RhF) was detected in 8 of the weakly reactive specimens and these had significantly higher titres of anti-HAV than sera known to contain RhF that were unreactive in MACRIA.It is concluded that tissue culture derived HAV antigen should replace that from primates on the grounds of quality, economy and convenience: also that non-specific activity in HAV MACRIA is usually due to a combination of RhF and high anti-HAV titres, but is infrequently strong enough to cause reactions interpreted as positive.  相似文献   