1.
The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.  相似文献   

2.
Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need to be acquired at specific delays following magnetization preparation or for transient artifact reduction in cardiac-gated k-space segmented CINE imaging. Such trajectories are problematic for balanced SSFP imaging due to nonconstant eddy current effects and resulting disruption of the steady state.In this work, a novel acquisition strategy for balanced SSFP imaging is presented that utilizes scan time reduction by parallel imaging for optimized "double average" eddy current compensation and artifact reduction during the transient phase following steady-state storage and magnetization preparation. Double average parallel SSFP imaging was applied to k-space segmented CINE SSFP tagging as well as nongated centrically encoded SSFP imaging. Phantom and human studies exhibit substantial reduction in steady-state storage and eddy current artifacts while maintaining spatial resolution, signal-to-noise ratio, and similar total scan time of a standard SSFP acquisition. The proposed technique can easily be extended to other acquisition schemes that would benefit from nonlinear reordering schemes and/or rely on interruption of the balanced SSFP steady state.  相似文献   

3.
Balanced steady-state free precession (SSFP) magnetic resonance (MR) imaging is feasible for cine cardiac images because of the high contrast between myocardium and blood pool and robustness to rapid blood flow. Nonetheless, the flow artifacts are often observed because of off-resonance effects and to in-flow effects of the blood flow. Although reshimming the gradients or readjusting the center frequency reduces the artifacts, the technique can be susceptible for respiratory and cardiac motion and operator-dependent. The purpose of this study is to use another MR imaging technique for the reduction in the flow artifacts in the heart: odd-even interleaved data acquisition in segmented balanced SSFP imaging. The flow artifacts in the ventricle, ghost outside the heart, and visualization of the myocardial border were visually compared between sequential and odd-even interleaved k-space data acquisitions in cine balanced SSFP cardiac MR imaging. The odd-even interleaved k-space data acquisition significantly reduced dark flow artifacts in the left ventricle, improved the visualization of the myocardial border, and was easily installed. This imaging technique should be applied to cine segmented balanced SSFP cardiac MR imaging.  相似文献   

4.
Balanced steady-state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood-myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced SSFP has been combined with spiral imaging for real-time interactive cardiac MRI. New features of this method to enable scanning in a clinical setting include short, first-moment nulled spiral trajectories and interactive control over the spatial location of banding artifacts (SSFP-specific signal variations). The feasibility of spiral balanced SSFP cardiac imaging at 1.5 T is demonstrated. In observations from over 40 volunteer and patient studies, spiral balanced SSFP imaging shows significantly improved contrast compared to spiral gradient-spoiled imaging, producing better visualization of cardiac function, improved localization, and reduced flow artifacts from blood.  相似文献   

5.
PURPOSE: To improve the performance of fat/water separation and reduce the sensitivity to susceptibility variation in balanced SSFP sequences. MATERIALS AND METHODS: Decreasing the repetition time (TR) reduces susceptibility artifacts in SSFP imaging. A shorter TR may also improve the spectral selectivity obtained when linearly combining data acquired using different radiofrequency phase cycling schedules. The desired short TR is achieved by using an angularly undersampled three-dimensional radial acquisition sequence that achieves a near zero echo time (TE) and also a short TR. RESULTS: Images from human volunteers demonstrate broad coverage of the cervical spine and knee with isotropic resolution. Excellent fat/water separation is achieved in these studies. CONCLUSION: The short TR capability of the proposed sequence greatly improves the fat suppression in SSFP imaging. High-resolution volumetric T2-like contrast imaged with reduced susceptibility artifacts can be obtained from a single acquisition using this technique.  相似文献   

6.
PURPOSE: To directly compare the three main myocardial perfusion cardiovascular magnetic resonance (CMR) sequences incorporating parallel acquisition methods. MATERIALS AND METHODS: In 15 subjects (12 men, 57 +/- 15.7 years) referred for diagnostic coronary angiography, we acquired first-pass perfusion images (0.1 mmol/kg gadolinium-DTPA) at rest and during adenosine (140 microg/kg/min) on three separate occasions using three sequences incorporating parallel acquisition methods and approximately equivalent spatiotemporal resolution: hybrid echo planar imaging (hEPI), steady-state free precession (SSFP), and gradient echo imaging (GRE). We calculated the contrast-to-noise ratio (CNR) of each scan and blinded observers scored the presence and severity of artifacts (1, worst to 4, best), diagnostic confidence (0, low to 2, high), transmurality, area, and epicardial vessel territory of perfusion defects. RESULTS: CNR was greatest with SSFP and least with hEPI (13.15 vs 7.85 P < 0.001). The most artifacts were recorded with SSFP and least with hEPI (2.00 vs 3.03 P < 0.001). Observers were significantly more confident in reporting hEPI images (1.6 hEPI vs 0.9 SSFP, P < 0.001). Results for GRE were intermediate for all assessments. CONCLUSION: The hEPI sequence scored best for diagnostic performance despite the SSFP sequence having greater CNR. This trial favors hEPI for clinical myocardial perfusion CMR and suggests CNR should not be the sole criterion used to gauge the best candidate sequence.  相似文献   

7.
The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.  相似文献   

8.
Variable nutation SSFP (DESPOT2) permits rapid, high-resolution determination of the transverse (T2) relaxation constant. A limitation of DESPOT2, however, is the presence of T2 voids due to off-resonance banding artifacts associated with SSFP images. These artifacts typically occur in images acquired with long repetition times (TR) in the presence of B0 inhomogeneities, or near areas of magnetic susceptibility difference, such that the transverse magnetization experiences a net phase shift during the TR interval. This places constraints on the maximum spatial resolution that can be achieved without artifact. Here, a novel implementation of DESPOT2 is presented incorporating RF phase-cycling which acts to shift the spatial location of the bands, allowing reconstruction of a single, reduced artifact-image. The method is demonstrated in vivo with the acquisition of a 0.34 mm3 isotropic resolution T2 map of the brain with high precision and accuracy and significantly reduced artifact.  相似文献   

9.
Refocused steady-state free precession (SSFP), or fast imaging with steady precession (FISP or TrueFISP), has recently proven valuable for cardiac imaging because of its high signal-to-noise ratio (SNR) and excellent blood-myocardium contrast. In this study, various implementations of multiecho SSFP or EPI-SSFP for imaging in the heart are presented. EPI-SSFP has higher scan-time efficiency than single-echo SSFP, as two or more phase-encode lines are acquired per repetition time (TR) at the cost of a modest increase in TR. To minimize TR, a noninterleaved phase-encode order in conjunction with a phased-array ghost elimination (PAGE) technique was employed, removing the need for echo time shifting (ETS). The multishot implementation of EPI-SSFP was used to decrease the breath-hold duration for cine acquisitions or to increase the temporal or spatial resolution for a fixed breath-hold duration. The greatest gain in efficiency was obtained with the use of a three-echo acquisition. Image quality for cardiac cine applications using multishot EPI-SSFP was comparable to that of single-echo SSFP in terms of blood-myocardium contrast and contrast-to-noise ratio (CNR). The PAGE method considerably reduced flow artifacts due to both the inherent ghost suppression and the concomitant reduction in phase-encode blip size. The increased TR of multishot EPI-SSFP led to a reduced specific absorption rate (SAR) for a fixed RF flip angle, and allowed the use of a larger flip angle without increasing the SAR above the FDA-approved limits.  相似文献   

10.
Coronary artery data acquisition with steady-state free precession (SSFP) is typically performed in a single frame in mid-diastole with a spectrally selective pulse to suppress epicardial fat signal. Data are acquired while the signal approaches steady state, which may lead to artifacts from the SSFP transient response. To avoid sensitivity to cardiac motion, an accurate trigger delay and data acquisition window must be determined. Cine data acquisition is an alternative approach for resolving these limitations. However, it is challenging to use conventional fat saturation with cine imaging because it interrupts the steady-state condition. The purpose of this study was to develop a 4D coronary artery imaging technique, termed "cine angiography with phase-sensitive fat suppression" (CAPS), that would result in high temporal and spatial resolution simultaneously. A 3D radial stacked k-space was acquired over the entire cardiac cycle and then interleaved with a sliding window. Sensitivity-encoded (SENSE) reconstruction with rescaling was developed to reduce streak artifact and noise. Phase-sensitive SSFP was employed for fat suppression using phase detection. Experimental studies were performed on volunteers. The proposed technique provides high-resolution coronary artery imaging for all cardiac phases, and allows multiple images at mid-diastole to be averaged, thus enhancing the signal-to-noise ratio (SNR) and vessel delineation.  相似文献   

11.
Balanced steady-state free precession (SSFP) imaging is limited by off-resonance banding artifacts, which occur with periodicity 1/TR in the frequency spectrum. A novel balanced SSFP technique for widening the band spacing in the frequency response is described. This method, called wideband SSFP, utilizes two alternating repetition times with alternating RF phase, and maintains high SNR and T(2)/T(1) contrast. For a fixed band spacing, this method can enable improvements in spatial resolution compared to conventional SSFP. Alternatively, for a fixed readout duration this method can widen the band spacing, and potentially avoid the banding artifacts in conventional SSFP. The method is analyzed using simulations and phantom experiments, and is applied to the reduction of banding artifacts in cine cardiac imaging and high-resolution knee imaging at 3T.  相似文献   

12.
T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE methods can be limited by artifacts such as posterior wall signal loss due to through-plane motion, and bright subendocardial artifacts due to stagnant blood. Single-shot imaging with a T2-prepared SSFP readout provides an alternative to dark-blood TSE and may be conducted during free breathing. We hypothesized that T2-prepared SSFP would be a more reliable method than dark-blood TSE for imaging of edema in patients with MI. In patients with MI (22 acute and nine chronic MI cases), T2-weighted imaging with both methods was performed prior to contrast administration and delayed-enhancement imaging. The T2-weighted images using TSE were nondiagnostic in three of 31 cases, while six additional cases rated as being of diagnostic quality yielded incorrect diagnoses. In all 31 cases the T2-prepared SSFP images were rated as diagnostic quality, correctly differentiated acute or chronic MI, and correctly determined the coronary territory. Free-breathing T2 prepared SSFP provides T2-weighted images of acute MI with fewer artifacts and better diagnostic accuracy than conventional dark-blood TSE.  相似文献   

13.
Cine balanced steady‐state free precession (SSFP) is the most widely used sequence for assessing cardiac ventricular function at 1.5 T because it provides high signal‐to‐noise ratio efficiency and strong contrast between myocardium and blood. At 3 T, the use of SSFP is limited by susceptibility‐induced off‐resonance, resulting in either banding artifacts or the need to use a short‐sequence pulse repetition time that limits the readout duration and hence the achievable spatial resolution. In this work, we apply wideband SSFP, a variant of SSFP that uses two alternating pulse repetition times to establish a steady state with wider band spacing in its frequency response and overcome the key limitations of SSFP. Prospectively gated cine two‐dimensional imaging with wideband SSFP is evaluated in healthy volunteers and compared to conventional balanced SSFP, using quantitative metrics and qualitative interpretation by experienced clinicians. We demonstrate that by trading off temporal resolution and signal‐to‐noise ratio efficiency, wideband SSFP mitigates banding artifacts and enables imaging with approximately 30% higher spatial resolution compared to conventional SSFP with the same effective band spacing. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

14.

Purpose:

To minimize image artifacts in long TR cardiac phase‐resolved steady state free precession (SSFP) based blood‐oxygen‐level‐dependent (BOLD) imaging.

Materials and Methods:

Nine healthy dogs (four male, five female, 20–25 kg) were studied in a clinical 1.5 Tesla MRI scanner to investigate the effect of temporal resolution, readout bandwidth, and motion compensation on long repetition time (TR) SSFP images. Breath‐held 2D SSFP cine sequences with various temporal resolutions (10–204 ms), bandwidths (239–930 Hz/pixel), with and without first‐order motion compensation were prescribed in the basal, mid‐ventricular, and apical along the short axis. Preliminary myocardial BOLD studies in dogs with controllable coronary stenosis were performed to assess the benefits of artifact‐reduction strategies.

Results:

Shortening the readout time by means of increasing readout bandwidth had no observable reduction in image artifacts. However, increasing the temporal resolution in the presence of first‐order motion compensation led to significant reduction in image artifacts. Preliminary studies demonstrated that BOLD signal changes can be reliably detected throughout the cardiac cycle.

Conclusion:

Artifact‐reduction methods used in this study provide significant improvement in image quality compared with conventional long TR SSFP BOLD MRI. It is envisioned that the methods proposed here may enable reliable detection of myocardial oxygenation changes throughout the cardiac cycle with long TR SSFP‐based myocardial BOLD MRI. J. Magn. Reson. Imaging 2010;31:863–871. ©2010 Wiley‐Liss, Inc.  相似文献   

15.
Cardiac MRI in neonates holds promise as a tool that can provide detailed functional information in this vulnerable group. However, their small size, rapid heart rate, and inability to breath‐hold, pose particular challenges that require prolonged high‐contrast and high‐SNR methods. Balanced‐steady state free precession (SSFP) offers high SNR efficiency and excellent contrast, but is vulnerable to off‐resonance effects that cause banding artifacts. This is particularly problematic in the blood‐pool, where off‐resonance flow artifacts severely degrade image quality. Methods: In this article, we explore active frequency stabilization, combined with image‐based shimming, to achieve prolonged SSFP imaging free of banding artifacts. The method was tested using 2D multislice SSFP cine acquisitions on 18 preterm infants, and the functional measures derived were validated against phase‐contrast flow assessment. Results: Significant drifts in the resonant frequency (165 ± 23Hz) were observed during 10‐min SSFP examinations. However, full short‐axis stacks free of banding artifacts were achieved in 16 subjects with stabilization; the cardiac output obtained revealed a mean difference of 9.0 ± 8.5% compared to phase‐contrast flow measurements. Conclusion: Active frequency stabilization has enabled the use of prolonged SSFP acquisitions for neonatal cardiac imaging at 3T. The findings presented could have broader implications for other applications using prolong SSFP acquisitions. Magn Reson Med 70:776–784, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

16.
PURPOSE: To explore the use of breath-hold and navigator-gated noncontrast Steady State Free Precession (SSFP) MR angiography (MRA) protocols for the evaluation of renal artery stenosis (RAS). MATERIALS AND METHODS: Twenty patients referred to rule out RAS were imaged using two breath-hold and one navigator-gated SSFP MRA sequences. All patients underwent contrast-enhanced MRA (CE-MRA). Two radiologists evaluated all sequences both qualitatively (blur, artifacts, reader confidence) and quantitatively (maximum stenosis). Using CE-MRA as truth, a receiver operating characteristics (ROC) curve was generated and a statistical analysis of navigator-gated SSFP (Nav SSFP) was performed. RESULTS: Seven patients had >50% renal artery stenosis by CE-MRA. Nav SSFP performed significantly better than either breath-hold SSFP technique in terms of blur, artifacts, and reader confidence. Using a 50% threshold for stenosis, sensitivity for detecting RAS was 100%, with a specificity of 85% and a negative predictive value of 100%. The average mean stenosis difference between Nav SSFP and CE-MRA was 9 +/- 9%. CONCLUSION: Nav SSFP outperformed breath-hold SSFP in measures of image quality and reader confidence. Sensitivity and negative predictive value for detecting RAS with Nav SSFP was perfect, with an acceptable specificity of 85%. This suggests further study is warranted to evaluate Nav SSFP as a noncontrast screening technique for renal artery stenosis.  相似文献   

17.

Purpose:

To suppress off‐resonance artifacts in coronary artery imaging at 3 Tesla (T), and therefore improve spatial resolution.

Materials and Methods:

Wideband steady state free precession (SSFP) sequences use an oscillating steady state to reduce banding artifacts. Coronary artery images were obtained at 3T using three‐dimensional navigated gradient echo, balanced SSFP, and wideband SSFP sequences.

Results:

The highest in‐plane resolution of left coronary artery images was 0.68 mm in the frequency‐encoding direction. Wideband SSFP produced an average SNR efficiency of 70% relative to conventional balanced SSFP and suppressed off‐resonance artifacts.

Conclusion:

Wideband SSFP was found to be a promising approach for obtaining noncontrast, high‐resolution coronary artery images at 3 Tesla with reliable image quality. J. Magn. Reson. Imaging 2010;31:1224–1229. © 2010 Wiley‐Liss, Inc.  相似文献   

18.
This study investigated the effects of flip angle setting in 3D balanced steady-state free precession (SSFP) imaging on CSF-parenchyma contrast and section aliasing artifacts. Theoretical derivations indicated that the extent of section aliasing artifacts decreased as the flip angle was lowered, at the expense of a sacrifice in CSF-parenchyma contrast. Experimental data agreed closely with theoretical predictions. A flip angle of about 40 degrees is therefore recommended for 3D balanced SSFP MR ventriculocisternography.  相似文献   

19.
Volume steady-state black-blood magnetic resonance imaging was evaluated as a method for depicting lower extremity vasculature. In steady-state imaging, flow has low signal intensity because motion destroys the coherence of transverse magnetization. To optimize image contrast, computations and measurements were obtained for the three-dimensional (3D) GRASS (gradient-recalled acquisition in the steady state) and 3D SSFP (steady-state free precession) sequences and a range of TRs and flip angles to determine optimal vessel-muscle contrast. The best results were achieved with a 3D GRASS sequence with a TR msec/TE msec of 25/5 and a flip angle of 30°. Coronal images of the femoral and popliteal vessels were obtained in healthy volunteers with various fields of view and voxel sizes. Inflow of unsaturated spins from outside the image region, yielding high signal intensity, could be a potential drawback in steady-state black-blood imaging; however, problems can be avoided by using coronal acquisitions and large fields of view. Steady-state black-blood imaging depicts vessels with high accuracy and is faster and free of flow artifacts.  相似文献   

20.
To compare the image quality of dynamic lung MRI with variations of steady-state free-precession (SSFP) and gradient echo (GRE) cine techniques at 1.5 T and 3 T. Ventilated porcine lungs with simulated lesions inside a chest phantom and four healthy human subjects were assessed with SSFP (TR/TE = 2.9/1.22 ms; 3 ima/s) and GRE sequences (TR/TE = 2.34/0.96 ms; 8 ima/s) as baseline at 1.5 and 3 T. Modified SSFPs were performed with nine to ten images/s (parallel imaging factors 2 and 3). Image quality for representative structures and artifacts was ranked by three observers independently. At 1.5 T, standard SSFP achieved the best image quality with superior spatial resolution and signal, but equal temporal resolution to GRE. SSFP with improved temporal resolution was ranked second best. Further acceleration (PI factor 3) was of no benefit, but increased artifacts. At 3 T, GRE outranged SSFP imaging with high lesion signal intensity, while artifacts on SSFP images increased visibly. At 1.5 T, a modified SSFP with moderate parallel imaging (PI factor 2) was considered the best compromise of temporal and spatial resolution. At 3 T, GRE sequences remain the best choice for dynamic lung MRI.  相似文献   