首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Purpose

To assess the impact of ultrasonography on defining the diagnostic and therapeutic pathways for pediatric patients admitted to the emergency department for acute abdominal pain.

Methods

We performed a retrospective study of all patients aged <16 years with acute abdominal pain who underwent ultrasound examination at our Diagnostic Imaging Department from October 2010 to March 2012. We investigated for each patient the pathway following ultrasound examination and definitive diagnosis. The impact of ultrasonography was defined based on the frequency with which the information resulting from this examination confirmed or denied the diagnostic suspicion made by the emergency physician on the basis of clinical and laboratory findings.

Results

In 497/729 patients (69 %), ultrasound examination did not determine variations in the diagnostic and therapeutic pathways, either because it confirmed the outcome of clinical examination and laboratory tests, or because, even addressing in the opposite direction to these, the emergency physician did not consider its result because of being particularly alarmed or sufficiently reassured by clinical examination and laboratory tests. In the remaining 232/729 cases (31 %), ultrasound examination determined an increase or a reduction of the provided care and attention (subsequently proved justified in the vast majority of cases) in spite of what was initially assessed based on clinical examination and laboratory tests.

Conclusions

The results of our retrospective study demonstrated that ultrasonography was a valuable tool in the management of pediatric patients with acute abdominal pain together with clinical examination and laboratory tests.  相似文献   

2.

Objective

The purpose of this study was to examine the validity and test–retest reliability of the ScreenAssist Lumbar Questionnaire (SALQ). If a high degree of reliability and validity could be determined, the questionnaire could provide physical therapists with a formal instrument to assist with the identification of patients with nonmusculoskeletal back pain or emergent musculoskeletal causes of back pain requiring referral to an alternate medical provider.

Methods

Participants were patients presenting to an internal medicine physician''s office with the main complaint of low back pain over a 6 months period. ScreenAssist Lumbar Questionnaire was performed twice on each patient within 48 hours of the appointment. A 4-month post-visit chart review was performed to compare scores and recommendations made by the questionnaire with the assessment and diagnosis made by the physician.

Results

The SALQ demonstrated a sensitivity of 0·100 (95% CI: 0·689–0·100) and specificity of 0·786 (95%CI: 0·492–0·951) compared to the assessment and diagnosis performed by the primary care physician. Overall, regarding the recommendation for referral, there was agreement on 20 of the 21 patients with a Kappa of 0·798.

Discussion

The overall test–retest reliability and validity for referral recommendation were high, which indicates that the SALQ may serve as an alternative to the use of red flags in isolation to assist the physical therapist in determining the need for medical referral as the practice continues to progress toward direct access. The positive outcome of this study supports the possible future benefit of the SALQ.  相似文献   

3.

Background

Point of care ultrasound (POCUS) is a useful diagnostic tool in medicine. POCUS provides an easy and reproducible method of diagnosis where conventional radiologic studies are unavailable. Telemedicine is also a great means of communication between educators and students throughout the world.

Hypothesis

Implementing POCUS with didactics and hands-on training, using portable ultrasound devices followed by telecommunication training, will impact the differential diagnosis and patient management in a rural community outside the United States.

Materials and methods

This is an observational prospective study implementing POCUS in Las Salinas, a small village in rural western Nicaragua. Ultrasound was used to confirm a diagnosis based on clinical exam, or uncover a new, previously unknown diagnosis. The primary endpoint was a change in patient management. International sonographic instructors conducted didactic and practical training of local practitioners in POCUS, subsequently followed by remote guidance and telecommunication for 3 months.

Results

A total of 132 patients underwent ultrasound examination. The most common presentation was for a prenatal exam (23.5 %), followed by abdominal pain (17 %). Of the 132 patients, 69 (52 %) were found to have a new diagnosis. Excluding pregnancy, 67 patients of 101 (66 %) were found to have a new diagnosis. A change in management occurred in a total of 64 (48 %) patients, and 62 (61 %) after excluding pregnancy.

Conclusion

Implementing POCUS in rural Nicaragua led to a change in management in about half of the patients examined. With the appropriate training of clinicians, POCUS combined with telemedicine can positively impact patient care.  相似文献   

4.

Purpose

To assess pattern of articular disc displacement in patients with internal derangement (ID) of temporomandibular joint (TMJ) with ultrasound.

Materials and methods

Prospective study was conducted upon 40 TMJ of 20 patients (3 male, 17 female with mean age of 26.1 years) with ID of TMJ. They underwent high-resolution ultrasound and MR imaging of TMJ. The MR images were used as the gold standard for calculating sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of ultrasound for diagnosis of anterior or sideway displacement of the disc.

Results

The anterior displaced disc was seen in 26 joints at MR and 22 joints at ultrasound. The diagnostic efficacy of ultrasound for anterior displacement has sensitivity of 79.3 %, specificity of 72.7 %, accuracy of 77.5 %, PPV of 88.5 %, NPV of 57.1 %, PLR of 2.9 and NLR of 0.34. The sideway displacement of disc was seen in four joints at MR and three joints at ultrasound. The diagnostic efficacy of ultrasound for sideway displacement has a sensitivity of 75 %, specificity of 63.6 %, accuracy of 66.7 %, PPV of 42.8, NPV of 87.5 %, PLR of 2.06, and NLR of 0.39.

Conclusion

We concluded that ultrasound is a non-invasive imaging modality used for assessment of anterior and sideway displacement of the articular disc in patients with ID of TMJ.  相似文献   

5.

Objective

To evaluate the use of ultrasound for the diagnosis of knee bursitis.

Materials and methods

One-hundred and fifty-eight patients who, from May 2013 to May 2014, had an ultrasound examination of the knee and magnetic resonance imaging (MRI) of the knee during the following month were eligible for the study. The exams were reviewed by two musculoskeletal radiologists with 20 years of experience.

Results

Of these patients, 15 (7 men, 8 women) had bursitis, while 143 (76 men, 67 women) had no bursitis. In evaluating knee bursitis, US, when compared to MRI, correctly identified 13 out of 15 cases of bursitis, showing a sensitivity of 86.67 %, specificity 100 %, and K index of 0.92. Particularly in the suprapatellar bursa, ultrasound showed bursitis in 5 cases versus 7 by MRI (sensitivity of 71.4 %, specificity of 100 %, and K index of 0.82).

Conclusion

Ultrasound can be used as a valuable tool for the evaluation of bursitis of the superficial bursae in patients who cannot undergo MRI.  相似文献   

6.

Introduction

Fiberoptic bronchoscopy is the standard method for verifying the correct position of a double-lumen endotracheal tube (DLET) prior to one-lung ventilation. However, it must be performed by a specially trained anesthesiologist and is often resource consuming. The aim of this study was to compare this approach with thoracic ultrasound done by a nurse anesthetist in terms of sensitivity, specificity, and cost-effectiveness.

Methods

We conducted a prospective cross-over case–control study involving 51 adult patients consecutively undergoing thoracic surgery with one-lung ventilation. After orotracheal intubation with a DLET, correct exclusion of the lung being operated on exclusion was assessed first by a certified anesthesiologist using standard fiberoptic bronchoscopy and then by a trained nurse anesthetist using thoracic ultrasound. The nurse was blinded as to the findings of the anesthesiologist’s examination.

Results

The two approaches proved to be equally sensitive and specific, but the ultrasound examination was more rapid. This factor, together with the fact that ultrasound was performed by a nurse instead of a physician, and the costs of materials and sterilization, had a significant economic impact amounting to a net saving of €37.20 ± 5.40 per case.

Conclusions

Although fiberoptic bronchoscopy is still the gold standard for checking the position of a DLET, thoracic ultrasound is a specific, sensitive, cost-effective alternative, which can be used to rapidly verify the proper function of the tube based on the demonstration of correct lung exclusion.  相似文献   

7.

Purpose

Contrast-enhanced ultrasound (CEUS) is the application of ultrasound contrast agents (UCAs) to traditional medical sonography. The development of UCAs allowed to overcome some of the limitations of conventional B-mode and Doppler ultrasound techniques and enabled the display of the parenchymal microvasculature. Purpose of this paper is to delineate the elements of a solid and science-based technique in the execution of urinary bladder CEUS.

Methods

We describe the technical execution of urinary bladder CEUS and the use of perfusion softwares to perform contrast enhancement quantitative analysis with generation of time–intensity curves from regions of interest.

Results

During CEUS, normal bladder wall shows a wash-in time of 13 s, a time to peak (TTP) >40 s, a signal intensity (SI) <45 % and a wash-out time >80 s; Low-grade urothelial cell carcinoma (UCC) shows a wash-in time of 13 s, a time to peak TTP >28 s, a SI <45 % and a wash-out time of 40 s; High-grade UCC shows a wash-in time of 13 s, a TTP >28 s, a SI >50 % and a wash-out time of 58 s.

Conclusions

CEUS is a useful tool for an accurate characterization of bladder UCC although it has some drawbacks. To avoid misunderstandings, a widely accepted classification and a standardized terminology about the most significant parameters of this application should be adopted in the immediate future.  相似文献   

8.

Introduction

Endometriosis is a common chronic gynaecological disease affecting 10 % of women of reproductive age. Of these 5–12 % may present bowel endometriosis that may be asymptomatic or associated with aspecific symptoms even bowel obstruction.

Case presentation

The case of a 41-year-old woman with history of ulcerative colitis, previous diagnosis of ovarian endometriosis, recurrent abdominal pain not related to the menstrual cycle, with abdominal pain and obstinate constipation for 2 weeks was referred. The patient underwent colonoscopy, transabdominal ultrasound and ultrasound-guided fine-needle biopsy to have a diagnosis.

Discussion

Endometriosis should be considered in the differential diagnosis of every woman of childbearing age who presents with gastrointestinal or abdominal symptoms. As demonstrated in our case and by the burgeoning literature in this field, we believe that the role of transabdominal ultrasound should be reconsidered in the management of abdominal diseases because this examination associated with ultrasound-guided fine-needle biopsy allows, in expert hands, to obtain adequate histological samples avoiding patients to undergo more invasive tests to get a diagnosis.  相似文献   

9.

Background

Cardiac output (CO) measurement in the intensive care unit (ICU) requires invasive devices such as the pulmonary artery (PA) catheter or arterial waveform pulse contour analysis (PCA). This study tests the accuracy and feasibility of point of care ultrasound (POCUS) of the common carotid artery to estimate the CO non-invasively and compare it to existing invasive CO measurement modalities.

Methods

Patients admitted to the surgical and cardiothoracic ICU in a tertiary university-affiliated academic center during a 4-month period, with invasive hemodynamic monitoring devices for management, were included in this cohort study. Common carotid artery POCUS was performed to measure the CO and the results were compared to an invasive device.

Results

Intensivists and ICU fellows, using ultrasound of the common carotid artery, obtained the CO measurements. Images of the Doppler flow and volume were obtained at the level of the thyroid gland. Concurrent CO measured via invasive devices was recorded. The patient cohort comprised 36 patients; 52 % were females. The average age was 59 ± 13 years, and 66 % were monitored via PCA device and 33 % via PA catheter. Intraclass correlation coefficient (ICC) analysis demonstrated almost perfect correlation (0.8152) between measurements of CO via ultrasound vs. invasive modalities. The ICC between POCUS and the invasive measurement via PCA was 0.84 and via PA catheter 0.74, showing substantial agreement between the ultrasound and both invasive modalities.

Conclusions

Common carotid artery POCUS offers a non-invasive method of measuring the CO in the critically ill population.  相似文献   

10.

Background

Enthesopathy is an evolving area for applied clinical research. MRI is the gold standard in the diagnosis of elbow joint pathology, but recent reports indicate that ultrasound imaging is more sensitive and accurate than MRI in detecting enthesopathy of the heels and knees. Too many patients are under-diagnosed and/or misdiagnosed because the early pathological changes of enthesitis in the different types of seronegative arthropathies are not detected.

Objectives

This study was undertaken to describe the ultrasound features of elbow enthesitis in patients with seronegative arthropathies.

Methods

We studied 38 diseased elbows in 38 patients with spondyloarthropathies (26 men and 12 women, mean age 32 years). All had elbow enthesopathy without typical conventional radiographic findings. Patients with histories of degenerative changes and/or local steroid injections were excluded. An HDI 3000 ATL ultrasound machine was used with a 5–12 MHz linear transducer to examine the affected elbow joints. The elbows of 10 normal healthy individuals were examined as normal controls. The patients were examined in the supine position with the elbow flexed 30°–50°. Longitudinal and transverse scans were obtained of the radiohumeral joint, the ulnahumeral joint, and the olecranon fossa. Two independent observers unaware of the clinical diagnosis read the ultrasound images and assessed the collateral ligaments, intratendinous echogenicity, tendon calcification, tendon thickness, presence of fluid, synovial proliferation, and bony changes. The reliability of the sonographic images was assessed by review of video recordings of the ultrasound examinations.

Results

Ultrasound revealed loss of the fibrillar echopattern (100 %), lack of a homogenous pattern with loss of the tightly packed echogenic dots (100 %), peritendinous edema with flaring of the tendon margins (84.2 %), irregular fusiform tendon thickening (100 %), and hyperechoic intratendinous lesions with ill-defined focal defects (18.4 %). Ultrasound also detected intratendinous calcifications of both the common extensor and common flexor tendons (52.6 %). Bony erosions were seen at the tendon insertions into the lateral epicondyles (13.15 %).

Conclusion

Ultrasonographic features of elbow enthesitis differed from those described in knee and heel enthesitis. Ultrasound clearly showed early signs of tendon calcification, tendon edema, peritendinitis, and bony entheseal erosions. However, in elbow enthesitis the early bone erosion was associated with bone marrow edema, and the common extensor tendon was diffusely thickened. Ultrasound is a reliable, reproducible bedside imaging procedure. It improves the documentation of disease activity, progression, and treatment responses in patients with spondyloarthropathies. We recommend its use for the diagnosis and post-treatment follow-up of patients with enthesitis and seronegative spondyloarthropathies.  相似文献   

11.

Introduction

We used contrast-enhanced ultrasound (CEUS) to estimate the effect of an increase in mean arterial pressure (MAP) induced by noradrenaline infusion on renal microvascular cortical perfusion in critically ill patients.

Methods

Twelve patients requiring a noradrenaline infusion to maintain a MAP more than 60 mmHg within 48 hours of intensive care unit admission were included in the study. Renal CEUS scans with destruction-replenishment sequences and Sonovue® (Bracco, Milano Italy) as a contrast agent, were performed at baseline (MAP 60 to 65 mmHg) and after a noradrenaline-induced increase in MAP to 80 to 85 mmHg.

Results

There was no adverse effect associated with ultrasound contrast agent administration or increase in noradrenaline infusion rate. Adequate images were obtained in all patients at all study times. To reach the higher MAP target, median noradrenaline infusion rate was increased from 10 to 14 μg/min.Noradrenaline-induced increases in MAP were not associated with a significant change in overall CEUS derived mean perfusion indices (median perfusion index 3056 (interquartile range: 2438 to 6771) arbitrary units (a.u.) at baseline versus 4101 (3067 to 5981) a.u. after MAP increase, P = 0.38). At individual level, however, we observed important heterogeneity in responses (range -51% to +97% changes from baseline).

Conclusions

A noradrenaline-induced increase in MAP was not associated with an overall increase in renal cortical perfusion as estimated by CEUS. However, at individual level, such response was heterogeneous and unpredictable suggesting great variability in pressure responsiveness within a cohort with a similar clinical phenotype.

Electronic supplementary material

The online version of this article (doi:10.1186/s13054-014-0653-3) contains supplementary material, which is available to authorized users.  相似文献   

12.

Purpose

To assess the diagnostic accuracy and inter-observer variability of ultrasound (US) in recognizing signs of intra or extra-capsular rupture of silicone breast implants by using the magnetic resonance imaging (MRI) findings as the reference standard.

Methods

150 patients for a total of 300 implants underwent breast US and subsequently MR examination searching for signs of intra or extra-capsular rupture. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for breast US having MRI findings as the reference standard. Cohen’s kappa statistics was used in order to assess inter-observer agreement for US.

Results

170/300 (57 %) implant ruptures were detected at US (intra-capsular n = 110, extra-capsular n = 60). By comparing US findings with MR results, overall sensitivity, specificity, accuracy, PPV, and NPV of 79, 63, 70, 65, and 77 %, respectively, were found for breast US. In case of intra-capsular rupture, sensitivity, specificity, accuracy, PPV, and NPV of 63, 63, 63, 45, and 77 %, respectively, were obtained; 100 % values were found for extra-capsular rupture US diagnosis.

Conclusion

US can be used as the first examination in patients with breast implants. US intra-capsular rupture detection requires further evaluation by MRI; in case of extra-capsular rupture US diagnosis, surgical implant removal could be proposed without further investigations.  相似文献   

13.

Purpose

To prospectively evaluate the prevalence of the embolization of the spleen in patients with definite left-sided infective endocarditis (IE) using a contrast-enhanced ultrasound (CEUS).

Methods

From March 2012 through September 2013, 18 consecutive patients (9 females and 9 males, aged 21–83 years) evaluated at our hospital and with definite left-sided IE according to the revised Duke criteria were enrolled. All of the patients gave informed written consent and the study was performed in conformity with the ethical guidelines of the Declaration of Helsinki. All of the patients were submitted to a CEUS of the spleen within 10 days after the definite diagnosis of IE. For the CEUS, a blood pool second-generation contrast agent and an ultrasound machine with a contrast harmonic imaging technology were used.

Results

The splenic CEUS showed infarctions in 11 patients (61 %) and resulted positive in the 2 patients with negative echocardiography.

Conclusions

In this study, CEUS of the spleen, a repeatable and low-cost imaging technique, easily allowed the bedside detection of asymptomatic and even tiny infarctions and showed a high rate of embolization in patients with definite left-sided IE. Therefore, in the setting of IE (possible or definite), CEUS of the spleen has the potential to better define or accelerate the diagnosis itself.

Electronic supplementary material

The online version of this article (doi:10.1007/s40477-014-0131-4) contains supplementary material, which is available to authorized users.  相似文献   

14.

Purpose

The presence of the subacromial-subdeltoid (SASD) bursa inflammation has recently been proposed as a primary radiologic factor predicting persistent limitation and pain in operated patients. The aim of the study was to verify the hypothesis that pain, or increased shoulder pain, could be associated with SASD bursitis not only in operated patients but also in general population.

Methods

A consecutive series of 1940 shoulder ultrasound examinations were performed by our Department over a 5-year period using linear multi-frequency probes. All reports of examination executed for shoulder pain were reviewed. The video clips were independently reviewed by two radiologists: effusion in the SASD bursa and the presence of other pathological conditions were evaluated and confirmed.

Results

A total of 1147 shoulder video clips were re-evaluated, and 1587 pathologies were detected; 65.5 % of patients had only one pathology, 30.4 % had two and 4.1 % presented three pathologies. The difference between the group with and without effusion is statistically significant for acromioclavicular joint arthritis, supraspinatus tendon calcific tendinopathy, full-thickness and superficial tear of the supraspinatus, traumas and rheumatoid arthritis with a p value <0.01.

Conclusions

Our study shows that the effusion in the SASD bursa is frequently associated with shoulder pain often independently from the underlying pathology; further studies are needed to confirm the statistical significance of this relationship by clarifying possible confounding factors.

Electronic supplementary material

The online version of this article (doi:10.1007/s40477-015-0167-0) contains supplementary material, which is available to authorized users.  相似文献   

15.

Introduction

Pilonidal disease is a benign anorectal inflammatory disease that involves the subcutaneous adipose tissue overlying the sacrococcygeal region.

The aim of the work

The current study aimed to assess the value of preoperative evaluation of pilonidal disease and the exclusion of perianal sepsis using superficial parts ultrasonography and endoanal ultrasound.

Methodology

Referred 30 patients were clinically diagnosed as pilonidal disease, all were examined with superficial parts ultrasonography and if the disease was extending to the perianal region further endoanal US was performed to exclude perianal sepsis.

Results

7 patients showed subcutaneous abscesses and 23 patients showed pilonidal sinus tracts. Among patients with pilonidal sinus tracts, six tracts (26 %) seen as superficially situated, short narrow tracts with straight course, no side branches and with a blind end situated away from the anal canal wall. 2 (9 %) tracts showed vertical orientation and three tracts (13 %) were wide and deeply situated reaching the presacral fascia. 7 cases (30 %) showed branching pilonidal sinus tracts, two cases of them showed more than one external opening. 5 patients (22 %) showed abnormally long tracts seen reaching the perianal region.

Conclusion

Ultrasonography is an available, inexpensive, safe imaging modality that yields a high degree of accuracy in evaluating pilonidal disease and in exclusion of perianal sepsis.  相似文献   

16.

Objective

The purpose of this study was to evaluate sonoelastography (SE) in the assessment of the long head of biceps tendon (LHBT) in patients with symptoms of biceps tendinitis or tendinosis and in patients without biceps lesion. The findings were compared with those obtained at clinical examination, using ultrasonography (US).

Materials and methods

36 shoulders of 34 consecutively registered patients with clinical symptoms and US findings of biceps tendinitis or tendinosis, and 114 shoulders of 98 patients without biceps lesions were assessed with SE. Transverse and longitudinal images of LHBT were obtained using SE. SE images were evaluated by reviewers using an experimentally proven color grading system.

Results

The transverse images of SE showed a mean sensitivity of 69.4 %, a mean specificity of 95.6 % and a mean accuracy of 89.3 %. Good correlation of conventional ultrasound findings was found (p < 0.001, r = 0.763). The longitudinal images of SE showed a mean sensitivity of 94.4 %, a mean specificity of 92.1 % and a mean accuracy of 92.7 %. Good correlation of conventional ultrasound findings was found (p < 0.001, r = 0.585). Inter-observer reliability of SE was in “almost perfect agreement” with a weighted kappa coefficient of 0.84.

Conclusions

SE has potential to be clinically useful in the detection of the intratendinous and peritendinous alterations of LHBT and has excellent accuracy and excellent correlation with conventional ultrasound findings.  相似文献   

17.

Introduction

The study was designed to assess the impact of fluid loading on lung aeration, oxygenation and hemodynamics in patients with septic shock and acute respiratory distress syndrome (ARDS).

Methods

During a 1-year period, a prospective observational study was performed in 32 patients with septic shock and ARDS. Cardiorespiratory parameters were measured using Swan Ganz (n = 29) or PiCCO catheters (n = 3). Lung aeration and regional pulmonary blood flows were measured using bedside transthoracic ultrasound. Measurements were performed before (T0), at the end of volume expansion (T1) and 40 minutes later (T2), consisting of 1-L of saline over 30 minutes during the first 48 h following onset of septic shock and ARDS.

Results

Lung ultrasound score increased by 23% at T2, from 13 at baseline to 16 (P < 0.001). Cardiac index and cardiac filling pressures increased significantly at T1 (P < 0.001) and returned to control values at T2. The increase in lung ultrasound score was statistically correlated with fluid loading-induced increase in cardiac index and was not associated with increase in pulmonary shunt or regional pulmonary blood flow. At T1, PaO2/FiO2 significantly increased (P < 0.005) from 144 (123 to 198) to 165 (128 to 226) and returned to control values at T2, whereas lung ultrasound score continued to increase.

Conclusions

Early fluid loading transitorily improves hemodynamics and oxygenation and worsens lung aeration. Aeration changes can be detected at the bedside by transthoracic lung ultrasound, which may serve as a safeguard against excessive fluid loading.  相似文献   

18.

Purpose

To study the usefulness of transrectal ultrasound (TRUS) for catheter guidance in cases of early reinsertion after radical prostatectomy (RP).

Methods

Since 2007, we have used TRUS for catheter guidance when early reinsertion after RP is required. A preliminary TRUS examination is done to carefully check the state of the vesicourethral anastomosis. The entire catheter insertion, from bulbar urethra to the bladder, is followed step by step by transrectal ultrasound imaging that tracks, while the probe pushes the catheter through a correct entering line. This prevents the incorrect placement of the catheter across the posterior aspect of the anastomosis in a posterior extravesical place.

Results

Between 2007 and 2011, 2,165 RPs were performed at reference hospital for prostate cancer. Early catheter reinsertion was required for 56 patients (2.6 %). All procedures were successful. The incidence of vesicourethral stricture after long-term follow-up was not different from that of patients without early recatheterization who were operated with RP in the same period of the study (4.4 vs 4.2 %, respectively; p = 0.47).

Conclusions

If early recatheterization is required in patients recently operated with RP, we suggest catheter guidance with TRUS.  相似文献   

19.

Background

Four-dimensional (4D) ultrasound scanning (3D real-time mode) can improve the orientation of the anatomy of the area of interest and navigation by controlling the needle position. The objectives of this study were to identify the optimal technique for navigation and to assess clinically the efficacy of 4D ultrasound navigation for epidural anaesthesia at lower thoracic and lumbar levels.

Design

Single-centre case series study was performed.

Methods

Sixteen patients were included. First, conventional 2D scanning was performed, followed by 4D reconstruction, and the basic tissues with high acoustic impedance (bone structures) and available acoustic windows were determined. Movement of the needle was controlled on the sagittal plane in 2D mode and at the same time in 4D mode (3D real-time mode). To improve the visibility of the needle, the 3D reconstruction was rotated during manipulation.

Results

The 4D scanning mode provided 100 % visibility of compact bone tissues and 93 % visibility of the posterior complex. Needle visualisation strongly depended on the rotation of the reconstructed image with the sensor remaining motionless. The needle was redirected in one patient (7 %) because it was in contact with the vertebral lamina. Dilation of the epidural space during saline injection was observed in five patients (36 %). A change in the puncture level was not required any patients; no complications associated with epidural puncture were observed.

Conclusions

Ultrasound navigation in 4D could improve epidural anaesthesia due to the enhanced spatial orientation of the operator. The technique of “position contrast” should be used for reliable needle visualisation.

Electronic supplementary material

The online version of this article (doi:10.1007/s40477-014-0150-1) contains supplementary material, which is available to authorized users.  相似文献   

20.

Purpose

This study aimed at comparing the diagnostic accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) for the detection of joint effusion of the knee.

Methods

For this retrospective study, approbation by the institutional review board was not required, and written informed consent from the patients was waived. One hundred and fifty-eight patients (83 men and 75 women; median age 41.2 years; age range 13–81 years) who underwent US and MRI of the knee were included in the study. The sensitivity and specificity of US with respect to MRI in the evaluation of the effusion of the knee and in each recess were compared.

Results

In evaluating joint effusion of the knee, compared with MRI, US correctly identified 78 of 96 patients with joint effusion, showing a sensitivity of 81.3 % and a specificity of 100 %, with a positive predictive value (PPV) of 100 % and a negative predictive value (NPV) of 77.5 % (p value = 0.001). Various results were obtained comparing ultrasound with MRI, regarding the various recesses.

Conclusion

US showed high specificity and sensitivity in diagnosing knee joint effusion and could be used in patients who cannot undergo MRI.

Electronic supplementary material

The online version of this article (doi:10.1007/s40477-015-0180-3) contains supplementary material, which is available to authorized users.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号