首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
Arthroscintigraphic evaluation of the painful total hip prosthesis   总被引:1,自引:0,他引:1  
Arthroscintigraphy was performed in 19 patients with a painful total hip prosthesis by injecting both Tc-99m sulfur colloid and iodinated radiographic contrast material intra-articularly. Scintigraphic and radiographic results correlated exactly in 15 patients, with one false-negative scintigram, one false-positive scintigram, and one false-negative arthrogram. One patient was evaluated by scintigraphy alone. Although arthroscintigraphy is potentially more sensitive than conventional arthrography in the detection of femoral component loosening, acetabular component loosening cannot be evaluated by scintigraphy alone. A combination of scintigraphy and conventional arthrography appears to be the most accurate imaging method in the evaluation of hip prosthesis loosening.  相似文献   

2.
The recent popularity of ingrowth or uncemented hip arthroplasties has presented problems in the radiographic diagnosis of loosening because there is no longer a cement interface in which lucencies may be seen. We evaluated a combination of positive contrast and nuclear arthrography to see whether these studies could accurately detect loosening of uncemented femoral components of hip prostheses. We performed routine contrast and nuclear arthrography in 21 patients with ingrowth total hip arthroplasties or bipolar endoprostheses. The results were surgically confirmed in 12 patients. The contrast arthrogram was true positive in 5 and false negative in 5. There were no false positives and 2 true negatives. The nuclear arthrogram was true positive in 7 patients, false negative in 3, and true negative in 2. Taken together, there was only 1 patient in whom both contrast and nuclear arthrography were false negative, and there were no false positives. Thus, when either contrast or nuclear arthrography is positive, the sensitivity of the combined procedures is 90%; when both studies are negative, the specificity is 100%. The combination of contrast and nuclear arthrography is an accurate method of determining loosening of the femoral component of an uncemented hip arthroplasty or bipolar endoprosthesis in the patient with postoperative hip pain.  相似文献   

3.
K-edge energy subtraction radiography is a method for detecting the presence of iodinated contrast material by subtracting two digital radiographs produced by X-ray beams with energies above and below the iodine K edge. We performed a feasibility study on the application of K-edge energy digital subtraction arthrography (KEDSA) to painful hip prostheses. During arthrography, loosening of the prosthesis is implied if contrast material is seen dissecting around the prosthesis, an often difficult detection task because of adjacent prosthesis metal or cement. In conventional arthrography a preliminary mask image is thus used from which films obtained after injection of iodinated contrast material are subtracted. Movement by the patient during this process may preclude subsequent subtraction. With KEDSA, since multiple image pairs may be obtained after the injection of contrast material, the problem of patient motion is virtually eliminated. A conventional X-ray tube operating between 55 and 65 kVp was alternately filtered by iodine and cerium filters to produce the KEDSA images. The apparatus was capable of producing a subtracted image within 3 sec. The technique was applied to phantoms and to six patients immediately after hip arthrography that had been positive for prosthesis loosening. Although of lower spatial resolution, the KEDSA images were, in all cases, positive for loosening in a pattern consistent with the conventional arthrographic images. KEDSA was shown to be successful in detecting extraarticular contrast material. During a single study, subtraction in various imaging planes as well as postexercise subtraction imaging can be accomplished-techniques not heretofore possible in routine subtraction arthrography.  相似文献   

4.
Radionuclide arthrography is becoming increasingly useful in the evaluation of femoral component loosening in patients with a painful total hip prosthesis. Additional potential advantages of radionuclide arthrography include detection of abnormal communications with the hip, such as bursae, abscess cavities, and fistulas. A case of cutaneous fistula communicating with the hip in a patient with loosening and infection of the femoral component of the total hip prosthesis that is clearly demonstrated by radionuclide arthrography is presented.  相似文献   

5.
Pain is a common unspecific symptom in orthopaedic prosthetics. The accurate differentiation between synovitis, loosening or infection is often difficult with conventional X-rays, arthrography or bone scintigraphy. Because of the high glucose uptake of inflammatory cells, [18F]fluorodeoxyglucose (18F-FDG) is an appropriate tracer for the evaluation of suspected inflammation or infection. In this preliminary study we describe 18F-FDG PET findings in patients referred for evaluation of painful hip or knee prostheses. We studied 23 patients with 28 prostheses, 14 hip and 14 knee prostheses, who had a complete operative or clinical follow-up. 18F-FDG PET scans were obtained with an ECAT EXACT HR+ PET scanner. High glucose uptake in the bone prostheses interface was considered as positive for infection, an intermediate uptake as suspect for loosening, and uptake only in the synovia was considered as synovitis. The imaging results were compared with operative findings or clinical outcome. PET correctly identified three hip and one knee prostheses as infected, two hip and two knee prostheses as loosening, four hip and nine knee prostheses as synovitis, and two hip and one knee prostheses as unsuspected for loosening or infection. In three patients covered with an expander after explantation of an infected prosthesis PET revealed no further evidence of infection in concordance with the clinical follow-up. PET was false negative for loosening in one case. Our preliminary results suggest that FDG PET could be a useful tool for differentiating between infected and loose orthopaedic prostheses as well as for detecting only inflammatory tissue such as synovitis.  相似文献   

6.
Nuclear medicine has proven to have a valuable role in the evaluation of osseous metallic implants, particularly with joint prostheses, but can assist with evaluation of other appliances as well. The nuclear arthrogram has become an invaluable adjunct to simultaneously performed radiographic contrast arthrography. This application has been best evaluated in what is one of the most common of orthopedic prosthesis problems, namely, loosening of total hip prostheses. Experience indicates that both sensitivity and specificity of loosening of the femoral component can be increased to over 90% through combined use of nuclear with radiographic contrast arthrography. Furthermore the combination of routine skeletal scintimaging with the nuclear arthrogram adds a significant dimension to precise localizing of the nuclear arthrographics agent In-111 chloride. Nuclear medicine also plays an important role in further evaluating the presence of infection associated with metallic implants with In-111 WBC preparations being superior to Ga-67 as the radiopharmaceutical tracer. Infection has been detected with a sensitivity of 73% and a specificity of 93% in our series using combined In-111 WBC and simultaneous skeletal imaging with conventional Tc-99m MDP. Acute infections are more readily identifiable than chronic in association with prostheses.  相似文献   

7.
Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.  相似文献   

8.
Radiological evaluation of painful total hip replacement   总被引:3,自引:0,他引:3  
Ninety-four cases of clinically failed, cemented, total hip prostheses requiring surgery were reviewed to determine the accuracy of preoperative plain radiography, culture of aspirated fluid, arthrography, and bone scanning. When radiopaque cement had been used to embed the prosthesis, plain radiography was highly accurate in detecting a loose femoral component, less so in detecting a loose acetabular component. Culture of aspirated fluid was accurate in diagnosing infection. A positive arthrogram identified loosening with good accuracy; however, a negative arthrogram did not reliably exclude loosening. 99mTc bone scans frequently differentiated loosening from loosening with infection. The suggested sequence of diagnostic tests is plain radiography followed by bone scanning. If the bone scan shows diffuse augmented uptake, culture of aspirated fluid followed by arthrography is indicated.  相似文献   

9.
The radiology of total hip replacement (THR) and its complications is reviewed in conjunction with a long-term follow-up study on 402 patients with 501 prostheses. The indications, contraindications, biomechanics, and operative management of these patients is discussed. Clinical complications such as deep vein thrombosis, pulmonary embolism, and hemorrhage are mentioned. Postoperative infections including granulomatous pseudotumors, dislocations and fractures, true loosening of the prosthesis, and heterotopic bone formation (HBF) are discussed and illustrated. The importance of differentiating the lucent line from true loosening is stressed. Mechanical and other clinical complications which are largely ignored by radiologists are also discussed. The uses of arthrography and bone scanning are included.  相似文献   

10.
Previous reports have stressed the value of hip arthrography primarily in determining the presence of loosening of the total hip prosthesis. Although loosening is a common complication and frequently associated with infection, other complications producing a painful hip prosthesis exist and are demonstrable by arthrography. Since the etiologies of these are as diversely different as the treatment, the hip arthrogram is advocated as an integral part of the diagnostic approach to the patient with a painful hip prosthesis in order to assess the specific complication and determine the therapeutic approach.  相似文献   

11.
A retrospective analysis of 52 patients with hip pain following total hip replacement was made. Each of them was evaluated by plain radiographs, technetium 99m pyrophosphate scans, arthrography with plain film subtraction technique, and culture of joint fluid. In 30 cases there was evidence of prosthetic loosening, and in 21 of these lymphangeal opacification during arthrography was seen. In 15 cases with lymphongeal opacification the diagnosis of prosthetic loosening was subsequently confirmed by prosthetic revision. In none of the 22 cases in which no evidence of prosthetic loosening was seen was there lymphatic opacification. It is concluded that lymphatic opacification during arthrography for pain following total hip prosthesis is a valuable ancillary sign of loosening.  相似文献   

12.
OBJECTIVE: To summarize and compare the diagnostic accuracy of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip arthroplasties. DESIGN: This meta-analysis was performed using methods described by the Cochrane Methods Group on Systematic Reviews of Screening and Diagnostic Tests. We included original, English-language papers published between January 1975 to October 2004 that examined contrast-enhanced arthrography with or without subtraction for diagnosis of loosening of total hip prostheses. A qualitative and quantitative analysis was performed by two investigators. RESULTS: With regard to the acetabular component, pooled sensitivity and specificity for contrast arthrography was 70% (95% confidence interval, 52-84) and 74% (95% CI, 53-87), respectively. Subtraction arthrography had a significantly higher sensitivity of 89% (95% CI, 84-93) (p=0.01), with a similar specificity of 76% (95% CI, 68-82). For the femoral component, pooled sensitivity and specificity for contrast arthrography were 63% (95% CI, 53-72) and 78% (95% CI, 68-86). Pooled estimates for subtraction arthrography revealed a significantly higher sensitivity of 86% (95% CI, 74-93) (p=0.003). Specificity was 85% (95% CI, 77-91) and was similar to the data of contrast arthrography (p=0.23). CONCLUSION: Using the present data we found that the subtraction arthrography is a sensitive technique for detection of loosening of total hip prostheses, offering added value over contrast arthrography, especially for evaluation of the femoral component.  相似文献   

13.
Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy (111In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ form that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111In-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses.  相似文献   

14.
Patients with problems following implantation of cemented total hip prostheses must be clinically examined. This examination is followed by a series of diagnostic imaging procedures. These include X-ray diagnosis, 3-phase 99mTc-MDP bone scans, scintigraphy for inflammation, and arthrography, performed singly or as sequential studies. X-ray findings and scintigraphic patterns arousing or confirming a suspicion of aseptic (mechanical) or septic (infectious) loosening of the prosthesis are evaluated and discussed.  相似文献   

15.
Twenty-five patients with symptomatic uncemented total hip components were studied with contrast arthrography prior to surgical exploration. All but one had uncemented femoral stems and 16 had an uncemented acetabular component. As judged by the findings at surgery, on the femoral side the sensitivity, specificity, and accuracy of arthrography were 57%, 60%, and 58% respectively. There was a relatively high incidence of both false positives (17%) and false negatives (25%). On the acetabular side sensitivity, specificity, and accuracy were 29%, 89%, and 62.5%. False negatives were common (31%), while there was only one false positive. The results in this small series show that arthrography has distinct limitations in identifying the fixation status of uncemented total hip components.  相似文献   

16.
Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. Digital subtraction arthrography of the femoral component demonstrated a 96% sensitivity and 100% specificity for the diagnosis of component loosening. Sensitivity and specificity for acetabular component loosening were 83% and 80%, respectively. Plain film subtraction of the femoral component demonstrated a 79% sensitivity and 100% specificity; the sensitivity and specificity for the acetabular component were 75% and 80%, respectively. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P<0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses.  相似文献   

17.
Radionuclide arthrography has been found to be valuable in the diagnosis of a loose hip prosthesis. The appearance of one normal case with no loosening and two abnormal cases with loosening of femoral and acetabular components are described. To diagnose this difficult problem, radionuclide arthrography should be used more frequently.  相似文献   

18.
The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.  相似文献   

19.
Serial radiographs of 101 total hip arthroplasties were reviewed to evaluate the clinical significance of lucent zones at the femoral metal-cement interface. Such lucent zones were identified in 19 hip prostheses, but only in four was there clinical evidence of infection loosening of the prosthesis. The remaining 14 patients (15 prostheses) were followed for periods ranging from 18 months to 5 years; none had complications despite the development of these lucent zones. Microdensitometry confirmed the existence of a true lucent zone in most cases, but in several the apparent lucency was due to the Mach effect. While progressive widening of the lucent zone or a lucency measuring greater than 2 mm in width should prompt careful clinical evaluation for evidence of infection or loosening, our data indicate that such complications need not necessarily be present.  相似文献   

20.
The authors had first experiences of hip arthrography in prostheses loosening in 1967. Now they explain the results obtained in 51 cases, aknowledging the limits of such a method in a few cases, but generally accepting the value of it for correct therapeutic choices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号