1.
Extensive studies have shown that titanium dioxide (TiO2) nanomaterials (NMs) can cause toxicity in vitro and in vivo under normal conditions. However, an adverse effect induced by nano‐TiO2 in many diseased conditions, typically characterized by oxidative stress (OS), remains unknown. We investigated the toxicity of nano‐TiO2 in rat liver cells (BRL‐3A) and Sprague–Dawley (SD) rat livers under OS conditions, which were generated using hydrogen peroxide (H2O2) in vitro and alloxan in vivo, respectively. In vitro results showed that cell death ratios after nano‐TiO2 exposure were significantly enhanced (up to 2.62‐fold) in BRL‐3A cells under OS conditions, compared with normal controls. Significant interactions between OS conditions and nano‐TiO2 resulted in the rapid G0/G1 to S phase transition and G2/M arrest, which were opposite to G0/G1 phase arrest in cells after NMs exposure only. In vivo results showed that obvious pathological changes in rat livers and the increased activities of four enzymes (i.e. aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase and alkaline phosphatase) owing to liver damage after nano‐TiO2 exposure under OS conditions, compared with their healthy controls. In addition, compared with increased hepatotoxicity after nano‐TiO2 exposure, micro‐TiO2 showed no adverse effects to cells and rat livers under OS conditions. Our results suggested that OS conditions synergistically increase nano‐TiO2 induced toxicity in vitro and in vivo, indicating that the evaluation of nanotoxicity under OS conditions is essentially needed prior to various applications of NMs in foods, cosmetics and potential treatment of diseases. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Heart diseases, which are related to oxidative stress (OS), negatively affect millions of people from kids to the elderly. Titanium dioxide (TiO2) has widespread applications in our daily life, especially nanoscale TiO2. Compared to the high risk of particulate matter (⩽2.5 μm) in air to heart disease patients, related research of TiO2 on diseased body is still unknown, which suggest us to explore the potential effects of nanoscale and microscale TiO2 to heart under OS conditions. Here, we used alloxan to induce OS conditions in rat, and investigated the response of heart tissue to TiO2 in healthy and alloxan treated rats. Compared with NMs treatment only, the synergistic interaction between OS conditions and nano-TiO2 significantly reduced the heart-related function indexes, inducing pathological changes of myocardium with significantly increased levels of cardiac troponin I and creatine kinase-MB. In contrast with the void response of micro-TiO2 to heart functions in alloxan treated rats, aggravation of OS conditions might play an important role in cardiac injury after alloxan and nano-TiO2 dual exposure. Our results demonstrated that OS conditions enhanced the adverse effects of nano-TiO2 to heart, suggesting that the use of NMs in stressed conditions (e.g., drug delivery) needs to be carefully monitored.  相似文献   

3.
Numerous studies have demonstrated the in vitro and in vivo neurotoxicity of nanoparticulate titanium dioxide (nano‐TiO2), a mass‐produced material for a large number of commercial and industrial applications. The mechanism of nano‐TiO2‐induced inhibition of axonal development, however, is still unclear. In our study, primary cultured hippocampal neurons of 24‐hour‐old fetal Sprague‐Dawley rats were exposed to 5, 15, or 30 μg/mL nano‐TiO2 for 6, 12, and 24 hours, and the toxic effects of nano‐TiO2 exposure on the axons development were detected and its molecular mechanism investigated. Nano‐TiO2 accumulated in hippocampal neurons and inhibited the development of axons as nano‐TiO2 concentrations increased. Increasing time in culture resulted in decreasing axon length by 32.5%, 36.6%, and 53.8% at 6 hours, by 49.4%, 53.8%, and 69.5% at 12 hours, and by 44.5%, 58.2%, and 63.6% at 24 hours, for 5, 15, and 30 μg/mL nano‐TiO2, respectively. Furthermore, nano‐TiO2 downregulated expression of Netrin‐1, growth‐associated protein‐43, and Neuropilin‐1, and promoted an increase of semaphorin type 3A and Nogo‐A. These studies suggest that nano‐TiO2 inhibited axonal development in rat primary cultured hippocampal neurons and this phenomenon is related to changes in the expression of axon growth‐related factors.  相似文献   

4.
ABSTRACT

The biological impact of nanomaterials (NMs) is determined by several factors such as size and shape, which need to be taken into consideration in any type of analysis. While investigators often prefer to conduct in vitro studies for detection of any possible adverse effects of NMs, in vivo approaches yield more relevant data for risk assessment. For this reason, Drosophila melanogaster was selected as a suitable in vivo model to characterize the potential risks associated with exposure nanorods (NRs), nanospheres (NSs), nanowires (NWs) forms of titanium dioxide (TiO2), and their microparticulated (or bulk) form, as TiO2. Third instar larvae (72 hr old larvae) were fed with TiO2 (NRs, NSs, or NWs) and TiO2 at concentrations ranging from 0.01 to 10 mM. Viability (toxicity), internalization (cellular uptake), intracellular reactive oxygen species (ROS) production, and genotoxicity (Comet assay) were the end-points evaluated in hemocyte D. melanogaster larvae. Significant intracellular oxidative stress and genotoxicity were noted at the highest exposure concentration (10 mM) of TiO2 (NRs, NSs, or NWs), as determined by the Comet assay and ROS analysis, respectively. A concentration–effect relationship was observed in hemocytes exposed to the NMs. Data demonstrated that selected forms of TiO2.-induced genotoxicity in D. melanogaster larvae hemocytes indicating this organism is susceptible for use as a model to examine in vivo NMs-mediated effects.  相似文献   

5.
《Nanotoxicology》2013,7(7):813-824
Abstract

The importance of composition, size, crystal structure, charge and coating of metal-based nanomaterials (NMs) were evaluated in human umbilical vein endothelial cells (HUVECs) and/or THP-1 monocytic cells. Biomarkers of oxidative stress and inflammation were assessed because they are important in the development of cardiovascular diseases. The NMs used were five TiO2 NMs with different charge, size and crystal structure, coated and uncoated ZnO NMs and Ag which were tested in a wide concentration range. There were major differences between the types of NMs; exposure to ZnO and Ag resulted in cytotoxicity and increased gene expression levels of HMOX1 and IL8. The intracellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1(VCAM-1) expression were highest in TiO2 NM-exposed cells. There was increased adhesion of THP-1 monocytic cells onto HUVECs with Ag exposure. None of the NMs increased the intracellular ROS production. There were no major effects of the coating of ZnO NMs. The TiO2 NMs data on ICAM-1 and VCAM-1 expression suggested that the anatase form was more potent than the rutile form. In addition, the larger TiO2 NM was more potent than the smaller for gene expression and ICAM-1 and VCAM-1 expression. The toxicological profile of cardiovascular disease-relevant biomarkers depended on composition, size and crystal structure of TiO2 NMs, whereas the charge on TiO2 NMs and the coating of ZnO NMs were not associated with differences in toxicological profile.  相似文献   

6.
The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO2, ZnO, CeO2, SiO2, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO2 NMs, CeO2 NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO2 NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO2 NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO2 only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization.  相似文献   

7.
Engineered nanomaterials (ENMs) are being produced for an increasing number of applications. Therefore, it is important to assess and categorize ENMs on the basis of their hazard potential. The immune system is the foremost defence against foreign bodies. Here we performed cytokine profiling of a panel of nineteen representative ENMs procured from the Joint Research Centre (JRC) and commercial sources. Physicochemical characterization was performed using dynamic light scattering. The ENMs were all shown to be endotoxin content free. The human macrophage-differentiated THP.1 cell line was employed for cytotoxicity screening and based on the calculated IC50 values, the multi-walled carbon nanotubes (MWCNTs), ZnO, Ag and SiO2 NMs were found to be the most cytotoxic while single-walled carbon nanotubes (SWCNTs), TiO2, BaSO4 and CeO2 NMs, as well as the nanocellulose materials, were non-cytotoxic (at doses up to 100?µg/mL). Multiplex profiling of cytokine and chemokine secretion indicated that the TiO2, SiO2, BaSO4, CeO2 and nanocellulose materials induced potent inflammatory responses at sub-cytotoxic doses. Hierarchical clustering of cytokine responses coupled with pathway analysis demonstrated that the panel of ENMs could be segregated into two distinct groups characterized by activation and deactivation, respectively, of PPAR (peroxisome proliferator-activated receptor)/LXR (liver X receptor/retinoid X receptor) nuclear receptor pathways (NRPs). Furthermore, using rosiglitazone, a selective PPAR-γ agonist, we could show that PPAR-γ played an important role in the activation of inflammatory responses in cells exposed to TiO2 and SiO2 NMs. These studies show that ENMs of diverse chemical compositions can be grouped according to their inflammatory potential.  相似文献   

8.
Because of its excellent optical performance and electrical properties, TiO2 has a wide range of applications in many fields. It is often considered to be physiologically inert to humans. However, some recent studies have reported that nano‐sized TiO2 may generate potential harm to the environment and humans. In this paper the in vivo acute toxicity of nano‐sized TiO2 particles to adult mice was investigated. Mice were injected with different dosages of nano‐sized TiO2 (0, 324, 648, 972, 1296, 1944 or 2592 mg kg–1). The effects of particles on serum biochemical levels were evaluated at various time points (24 h, 48 h, 7 days and 14 days). Tissues (spleen, heart, lung, kidney and liver) were collected for titanium content analysis and histopathological examination. Treated mice showed signs of acute toxicity such as passive behavior, loss of appetite, tremor and lethargy. Slightly elevated levels of the enzymes alanine aminotransferase and aspartate aminotransferase were found from the biochemical tests of serum whereas blood urea nitrogen was not significantly affected (<0.05). The accumulation of TiO2 was highest in spleen (<0.05). TiO2 was also deposited in liver, kidney and lung. Histopathological examinations showed that some TiO2 particles had entered the spleen and caused the lesion of spleen. Thrombosis was found in the pulmonary vascular system, which could be induced by the blocking of blood vessels with TiO2 particles. Moreover, hepatocellular necrosis and apoptosis, hepatic fibrosis, renal glomerulus swelling and interstitial pneumonia associated with alveolar septal thickening were also observed in high‐dose groups. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
The toxicity of titanium dioxide nanoparticles (TiO2‐NPs), used in several applications, seems to be influenced by their specific physicochemical characteristics. Cyto‐genotoxic and inflammatory effects induced by a mixture of 79% anatase/21% rutile TiO2‐NPs were investigated in human alveolar (A549) and bronchial (BEAS‐2B) cells exposed to 1–40 µg ml–1 30 min, 2 and 24 h to assess potential pulmonary toxicity. The specific physicochemical properties such as crystallinity, NP size and shape, agglomerate size, surface charge and specific surface area (SSA) were analysed. Cytotoxic effects were studied by evaluating cell viability using the WST1 assay and membrane damage using LDH analysis. Direct/oxidative DNA damage was assessed by the Fpg‐comet assay and the inflammatory potential was evaluated as interleukin (IL)‐6, IL‐8 and tumour necrosis factor (TNF)‐α release by enzyme‐linked immunosorbant assay (ELISA). In A549 cells no significant viability reduction and moderate membrane damage, only at the highest concentration, were detected, whereas BEAS‐2B cells showed a significant viability reduction and early membrane damage starting from 10 µg ml–1. Direct/oxidative DNA damage at 40 µg ml–1 and increased IL‐6 release at 5 µg ml–1 were found only in A549 cells after 2 h. The secretion of pro‐inflammatory cytokine IL‐6, involved in the early acute inflammatory response, and oxidative DNA damage indicate the promotion of early and transient oxidative‐inflammatory effects of tested TiO2‐NPs on human alveolar cells. The findings show a higher susceptibility of normal bronchial cells to cytotoxic effects and higher responsiveness of transformed alveolar cells to genotoxic, oxidative and early inflammatory effects induced by tested TiO2‐NPs. This different cell behaviour after TiO2‐NPs exposure suggests the use of both cell lines and multiple end‐points to elucidate NP toxicity on the respiratory system. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Autophagy is the catabolic process involving the sequestration of the cytoplasm within double-membrane vesicles, which fuse with lysosomes to form autolysosomes in which autophagic targets are degraded. Since most endocytic routes of nanomaterial uptake converge upon the lysosome and the possibility that autophagy induction by NMs may be an attempt by the cell to self-preserve following the external challenge, this study investigated the role of autophagy following exposure to a panel of widely used metal-based NMs with high toxicity (Ag and ZnO) or low toxicity (TiO2) in a pulmonary (A549) and hepatic (HepG2) cell line. The in vitro exposure to the Ag and ZnO NMs resulted in the induction of both apoptosis and autophagy pathways in both cell types. However, the progression of autophagy was blocked in the formation of the autolysosome, which coincided with morphologic changes in the actin cytoskeleton. This response was not observed following the exposure to low-toxicity TiO2 NMs. Overall, the results show that high toxicity NMs can cause a dysfunction in the autophagy pathway which is associated with apoptotic cell death.  相似文献   

11.
12.
13.
《Toxicology in vitro》2014,28(1):60-69
Toxicological characterization of manufactured nanomaterials (NMs) is essential for safety assessment, while keeping pace with innovation from their development and application in consumer products. The specific physicochemical properties of NMs, including size and morphology, might influence their toxicity and have impact on human health. The present work aimed to evaluate the genotoxicity of nanosized titanium dioxide (TiO2), synthetic amorphous silica (SAS) and multiwalled carbon nanotubes (MWCNTs), in human lymphocytes. The morphology and size of those NMs were characterized by transmission electron microscopy, while the hydrodynamic particle size-distributions were determined by dynamic light scattering. Using a standardized procedure to ensure the dispersion of the NMs and the cytokinesis-block micronucleus assay (without metabolic activation), we observed significant increases in the frequencies of micronucleated binucleated cells (MNBCs) for some TiO2 NMs and for two MWCNTs, although no clear dose–response relationships could be disclosed. In contrast, all forms of SAS analyzed in this study were unable to induce micronuclei. The present findings increase the weight of evidence towards a genotoxic effect of some forms of TiO2 and some MWCNTs. Regarding safety assessment, the differential genotoxicity observed for closely related NMs highlights the importance of investigating the toxic potential of each NM individually, instead of assuming a common mechanism and equal genotoxic effects for a set of similar NMs.  相似文献   

14.
Many studies have shown that the composition of the protein corona dramatically affects the response of cells to nanomaterials (NMs). However, the role of each single protein is still largely unknown. Fibrinogen (FG), one of the most abundant plasma proteins, is believed to mediate foreign-body reactions. Since this protein is absent in cell media used in in vitro toxicological tests the possible FG-mediated effects have not yet been assessed. Here, the effect of FG on the toxicity of three different kinds of inorganic NMs (carbon, SiO2 and TiO2) on alveolar macrophages has been investigated. A set of integrated techniques (UV–vis spectroscopy, dynamic light scattering and sodium dodecyl sulphate-polyacrylamide gel electrophoresis) have been used to study the strength and the kinetics of interaction of FG with the NMs. The inflammatory response of alveolar macrophages (MH-S) exposed to the three NMs associated with FG has also been investigated. We found that FG significantly enhances the cytotoxicity (lactate dehydrogenase leakage) and the inflammatory response (increase in nitric oxide (NO) concentration and NO synthase activation) induced by SiO2, carbon and TiO2 NMs on alveolar macrophages. This effect appears related to the amount of FG interacting with the NMs. In the case of carbon NMs, the activation of fibrinolysis, likely related to the exposure of cryptic sites of FG, was also observed after 24?h. These findings underline the critical role played by FG in the toxic response to NMs.  相似文献   

15.
Titanium dioxide nanoparticles (TiO2‐NPs) have been widely used in many applications. Owing to their nanoscale size, interactions between cells and NPs have been expansively investigated. With the health concerns raised regarding the adverse effects of these interactions, closer examination of whether TiO2‐NPs can induce toxicity towards human cells is greatly needed. Therefore, in this study, we investigated the cytotoxicity of TiO2‐NPs towards human blood cells (peripheral blood mononuclear cells [PBMCs]) in serum‐free medium, for which there is little information regarding the cytotoxic effects of TiO2‐NPs. Our results provide evidence that PBMCs treated with TiO2‐NPs (at concentrations ≥25 μg ml?1) for 24 h significantly reduced cell viability and significantly increased production of toxic mediators such as reactive oxygen species and inflammatory response cytokines such as interleukin‐6 and tumor necrosis factor‐α (P < 0.05). Cell apoptosis induction also occurred at these concentrations. Significant expressions of cyclooxygenase‐2 and interleukin‐1β were also observed in PBMCs treated with TiO2‐NPs at concentrations ≥125 μg ml?1. Our data presented here clearly indicate that the concentration of TiO2‐NPs (at size ~26.4 ± 1.2 nm) applied to human blood cells has a strong impact on cytotoxic induction. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
17.
Models for oral uptake of nanoparticles in consumer products   总被引:1,自引:0,他引:1  
Fröhlich E  Roblegg E 《Toxicology》2012,291(1-3):10-17
Presently, many consumer products contain nano-sized materials (NMs) to improve material properties, product quality and ease of use. NMs in food additives and in cosmetic articles (e.g., tooth paste) may be taken up by the oral route. As adverse effects of environmental nanoparticles, like ultrafine particles, have been reported, consumers worry about potential risks when using products containing NMs. The review focuses on metal and metal oxide NMs as common additives in tooth paste and in food industry and exposure by the oral route. Testing of NMs for oral exposure is very complex because differences in the diet, in mucus secretion and composition, in pH, in gastrointestinal transit time and in gastrointestinal flora influence NM uptake. Acellular (mucus, saliva) and epithelial layer of the orogastrointestinal barrier are described. Expected exposure doses, interaction of the NMs with mucus and permeation through the epithelium as well as in vivo data are mentioned. The role of in vitro models for the study of parameters relevant for ingested NMs is discussed.  相似文献   

18.
The potential hazard to humans exposed to nanomaterials such as silica and iron oxide was investigated using an in vitro macrophage cell culture system. Amorphous silica and iron oxide particles and nanomaterials (NMs) were dispersed in cell culture medium supplemented with either bovine serum albumin (BSA), lung lining fluid (LLF) or serum, in order to mimic the body fluids encountered during different routes of exposure in the body. End points investigated included macrophage viability and cytokine production. Silica NMs and particles (50 and 200 nm, respectively) were unmodified (plain) or aminated (NH2). Iron oxide NMs and particles, Fe3O4 45 nm and Fe2O3 280 nm were also used in this study. Silica particles and NMs induced a dose‐dependent increase in cytotoxicity as measured by lactate dehydrogenase (LDH) release. Serum enhanced silica‐induced interleukin (IL)‐6, IL‐10, IL‐1β and MCP‐1 release, whereas albumin partially inhibited MCP‐1 release. Aminated silica, 50 nm was more potent than the 200‐nm particles at inducing monocyte chemoattractant protein‐1 (MCP‐1) production when dispersed in medium or LLF, suggesting a size specific effect for these particles and this cytokine. Iron oxide particles were relatively inert compared with the silica particles and NMs; however, serum and albumin did affect cytokine release in some treatments. In conclusion, the data suggests that serum, compared with medium, BSA and LLF is very potent at enhancing macrophage responses to silica and iron oxide particles and NMs. Size was only influential in LLF for a limited number of parameters, whereas surface chemistry was not of consequence in this in vitro macrophage system. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
Despite intensive research activities, there are still many major knowledge gaps over the potential adverse effects of titanium dioxide nanoparticles (TiO2‐NPs), one of the most widely produced and used nanoparticles, on human cardiovascular health and the underlying mechanisms. In the present study, alkaline comet assay and cytokinesis‐block micronucleus test were employed to determine the genotoxic potentials of four sizes (100, 50, 30, and 10 nm) of anatase TiO2‐NPs to human umbilical vein endothelial cells (HUVECs) in culture. Also, the intracellular redox statuses were explored through the measurement of the levels of reactive oxygen species (ROS) and reduced glutathione (GSH) with kits, respectively. Meanwhile, the protein levels of nuclear factor erythroid 2‐related factor 2 (Nrf2) were also detected by western blot. The results showed that at the exposed levels (1, 5, and 25 μg/mL), all the four sizes of TiO2‐NPs could elicit an increase of both DNA damage and MN frequency in HUVECs in culture, with a positive dose‐dependent and negative size‐dependent effect relationship (T100 < T50 < T30 < T10). Also, increased levels of intracellular ROS, but decreased levels of GSH, were found in all the TiO2‐NP‐treated groups. Intriguingly, a very similar manner of dose‐dependent and size‐dependent effect relationship was observed between the ROS test and both comet assay and MN test, but contrary to that of GSH assay. Correspondingly, the levels of Nrf2 protein were also elevated in the TiO2‐NP‐exposed HUVECs, with an inversely size‐dependent effect relationship. These findings indicated that induction of oxidative stress and subsequent genotoxicity might be an important biological mechanism by which TiO2‐NP exposure would cause detrimental effects to human cardiovascular health.  相似文献   

20.
The basic tenets for assessing health risks posed by nanoparticles (NP) requires documentation of hazards and the corresponding exposures that may occur. Accordingly, this review describes the range and types of potential human exposures that may result from interactions with titanium dioxide (TiO2) particles or NP – either in the occupational/workplace environment, or in consumer products, including food materials and cosmetics. Each of those applications has a predominant route of exposure. Very little is known about the human impact potential from environmental exposures to NP – thus this particular issue will not be discussed further. In the workplace or occupational setting inhalation exposure predominates. Experimental toxicity studies demonstrate low hazards in particle-exposed rats. Only at chronic overload exposures do rats develop forms of lung pathology. These findings are not supported by multiple epidemiology studies in heavily-exposed TiO2 workers which demonstrate a lack of correlation between chronic particle exposures and adverse health outcomes including lung cancer and noncancerous chronic respiratory effects. Cosmetics and sunscreens represent the major application of dermal exposures to TiO2 particles. Experimental dermal studies indicate a lack of penetration of particles beyond the epidermis with no consequent health risks. Oral exposures to ingested TiO2 particles in food occur via passage through the gastrointestinal tract (GIT), with studies indicating negligible uptake of particles into the bloodstream of humans or rats with subsequent excretion through the feces. In addition, standardized guideline-mandated subchronic oral toxicity studies in rats demonstrate very low toxicity effects with NOAELs of >1000 mg/kg bw/day. Additional issues which are summarized in detail in this review are: 1) Methodologies for implementing the Nano Risk Framework – a process for ensuring the responsible development of products containing nanoscale materials; and 2) Safe-handling of nanomaterials in the laboratory.  相似文献   