1.
Objectives. An initial crossover study comparing dual- and single-site right atrial pacing was performed followed by a long-term efficacy and safety evaluation of dual-site right atrial pacing in patients with drug-refractory atrial fibrillation (AF). Also examined was the efficacy of two single-site right atrial pacing modes (high right atrium and coronary sinus ostium) and the long-term need for cardioversion, antithrombotic and antiarrhythmic drug therapies during dual-site atrial pacing.

Methods. Thirty consecutive patients with drug-refractory symptomatic AF and documented primary or drug-induced bradycardia were implanted with a dual chamber rate-responsive pacemaker and two atrial leads. Single-site atrial pacing was performed at the high right atrium or the coronary sinus ostium. Continuous atrial pacing was maintained.

Results. Mean arrhythmia-free intervals increased from 9 ± 10 days in the control period preceding implant to 143 ± 110 days (p < 0.0001) in single-site right atrial pacing and 195 ± 96 days in dual-site right atrial pacing (p < 0.005 versus single-site pacing and p < 0.0001 versus control). Dual-site right atrial pacing significantly increased the proportion of patients free of AF recurrence (89%) as compared to single-site right atrial pacing (62%, p = 0.02). High right atrial pacing and coronary sinus ostial pacing had similar efficacy for AF prevention. Effective rhythm control was achieved in 86% of patients during dual right atrial pacing. Seventy-eight percent of patients at 1 year and 56% at 3 years remained free of symptomatic AF. The need for cardioversion was reduced after pacemaker implant (p < 0.05) and antithrombotic therapy was reduced (p < 0.06) without any thromboembolic event. Coronary sinus ostial lead dislodgement was not observed after discharge.

Conclusions. Atrial pacing in combination with antiarrhythmic drugs eliminates or markedly reduces recurrent AF. Prevention of AF is enhanced by dual-site right atrial pacing. High right atrial and coronary sinus ostial pacing do not differ in efficacy. Dual-site right atrial pacing is safe, achieves long-term rhythm control in most patients, decreases the need for cardioversion, and antithrombotic therapy can be selectively reduced.  相似文献   


2.
Atrial fibrillation (AF) is a common arrhythmia associated with stroke, increased mortality and with a negative impact on quality of life. Pharmacologic treatments for AF have not provided long-term relief from arrhythmia recurrence. Multi-site atrial pacing was introduced by Daubert and colleagues about 10 years ago for the treatment of severe atrial conduction delays in patients with sick sinus syndrome. They found that this type of atrial stimulation reduced or prevented AF. Multi-site atrial pacing results in reduction of intra-atrial and interatrial conduction differences and diminishes heterogeneity of refractoriness, i.e. atrial resynchronization. Acute electrophysiological studies have shown that biatrial stimulation reduced AF inducibility. The Dutch Dual-site Right Atrial Pacing for Prevention of Atrial Fibrillation study was a prospective randomized crossover trial comparing the recurrences of AF in dual-site right atrial and single-site high right atrial pacing in patients with symptomatic medically refractory AF, without or with minimal structural heart disease. Patients were randomized to initial dual-site pacing (Group I n = 18) or initial single-site (Group II n = 22) pacing. After 6 months or after a study endpoint was reached patients were crossed over to the other pacing modality.Although, the arrhythmia free intervals were longer for dual-site pacing during both treatments periods (Group I 162 +/- 12 and Group II 114 +/- 15 days) compared to single-site pacing (Group I 143 +/- 16 and Group II 97 +/- 10 days) the difference was not statistically significant (p = 0.061). However, the sequence of the randomized treatment periods had a significant effect on outcome (p < 0.02). Event free intervals (AF > 48 hours requiring electrical cardioversion) were longer during dual-site pacing in both groups compared to single-site stimulation but the difference was statistically not significant (p = 0.055) because of treatment interaction (P < 0.05). To establish the clinical benefits of multi-site pacing for the treatment of patients with medically refractory symptomatic AF, additional prospective randomized studies are needed. Trials with a parallel design are necessary to avoid carry-over effects of different stimulation protocols.  相似文献   

3.
AIMS : Bifocal right atrial pacing (BP) has been reported to increase arrhythmia-free intervals in patients with paroxysmal atrial fibrillation (PAF) under antiarrhythmic drugs. This study compares AF burden with unifocal pacing (UP) vs BP under sotalol. METHODS : In 19 patients with PAF a DDDR pacemaker with right atrial lateral and CS ostial leads was implanted. Sotalol was initiated. After a 3 month back-up pacing period patients were randomized to continuous UP or BP for 3 months and crossed over for 3 more months. Primary endpoint was AF burden. Secondary endpoints included number of episodes, time to first recurrence and safety of BP. RESULTS : The intention to treat analysis revealed 12.4% AF during back-up, 6.2% during UP and BP (p=0.91 UP vs BP, p=0.08 back-up vs UP and p=0.07 back-up vs BP). Per protocol analysis showed no advantage of either pacing mode (UP 4.8% and BP 5.4% AF, p=0.64). Overdrive pacing reduced AF burden to 6.2 vs 8.8% during back-up (p=0.09). Septal lead dislodgement occurred in 3 patients. CONCLUSION : Atrial pacing tends to reduce AF burden in patients with PAF under sotalol. An incremental effect of BP vs UP cannot be confirmed. BP may be complicated by elevated lead dislodgement rates.  相似文献   

4.
Pacing for the prevention of atrial fibrillation.   总被引:3,自引:0,他引:3  
Nonpharmacological methods are being evaluated for the prevention of atrial fibrillation. The role of atrial pacing has been extensively examined in a large number of retrospective and prospective studies, and recently in randomized multicenter trials. The populations examined have varied from patients with sick sinus syndrome with incidental AF, to patients with drug refractory AF. In addition to standard atrial pacing from the high right atrium, pacing from novel sites like the interatrial septum, Bachman bundle, and dual-site or biatrial pacing have been employed for the prevention of AF. This review discusses the current status of different single-site pacing and dual-site pacing modes for the prevention of AF. It also discusses the mechanism of prevention of AF with these modes and the future directions these modes may take.  相似文献   

5.
OBJECTIVES: We compared the safety, tolerance and effectiveness of overdrive high right atrial (RA), dual-site RA and support (DDI or VDI) pacing (SP) in patients with symptomatic atrial fibrillation (AF) and bradycardias. BACKGROUND: Optimal pacing methods for AF prevention remain unclear. METHODS: Patients (n = 118) were randomized to each of three pacing modes in a crossover trial. RESULTS: Mode adherence was superior for dual-site RA (5.8 months) compared with SP (3.3 months; p < 0.001) and high RA pacing (4.7 months; p = 0.006). Adverse event-free survival improved with dual-site RA (p = 0.007 vs. SP) and was comparable to high RA (p = 0. 75). AF-free survival trended to improve with dual-site RA (hazard ratio [HR] 0.715, p = 0.07 vs. SP) but not high RA (HR = 0.71, p = 0.19) or when dual-site RA was compared with high RA (HR = 0.835, p = 0.175). Time-to-recurrence was longer in dual-site RA (1.77 months) compared with high RA (0.62 months, p < 0.09) or SP (0.44 months, p < 0.05). In antiarrhythmic drug-treated patients, dual-site RA reduced recurrence risk compared with SP (HR = 0.638, p = 0.011) and high RA (HR = 0.669, p = 0.06). In patients with < or =1 AF event/week, dual-site RA improved AF suppression (HR = 0.464, p = 0.004 vs. SP; HR = 0.623, p = 0.006 vs. high RA). Dual-site RA improved AF-free and mode survival (p < 0.03 vs. high RA, p < 0.001 vs. SP) and reduced asymptomatic AF (p < 0.01 vs. high RA). CONCLUSION: Dual-site RA is safe and better tolerated than high RA and SP. In patients on antiarrhythmics, dual-site RA prolonged and high RA trended to prolong time-to-recurrent AF compared with SP. Dual-site RA provides superior symptomatic and asymptomatic AF prevention compared with high RA in patients with symptomatic AF frequency of < or =1/week.  相似文献   

6.
We evaluated the long-term efficacy, safety, and applicability of a "hybrid" therapy strategy for rhythm control in atrial fibrillation (AF), incorporating dual-site right atrial pacing, antiarrhythmic drugs, and right atrial ablation. One hundred thirteen patients (paroxysmal AF [n = 70], persistent/permanent AF [n = 43]) with refractory symptomatic AF were treated with this strategy and followed for 1 to 81 months (mean 30 +/- 23). All-cause mortality, AF recurrences, and progression to permanent AF were monitored and recorded by implanted device data logs. There was no procedural mortality. Rhythm control was achieved in 90% of all patients at 3 and 5 years, with comparable efficacy in subpopulations with paroxysmal (98%), persistent, or permanent AF (87%, p >2). Overall survival was 84% at 3 years and 80% at 5 years, and was higher in patients with paroxysmal AF than in patients with persistent or permanent AF (86% vs 67% at 4 years, p <0.001). Patients with persistent or permanent AF had a greater need for cardioversion (p <0.004) and right atrial ablation (p <0.04) than patients with paroxysmal AF to achieve comparable rhythm control. A hybrid therapy strategy can provide safe and effective long-term rhythm control in patients with drug-refractory AF, and can be implemented in subpopulations presenting with paroxysmal, persistent, or permanent AF.  相似文献   

7.
OBJECTIVES

To determine the effects of single-, dual-, triple- and quadruple-site atrial pacing on atrial activation and refractoriness in normal canine hearts.

BACKGROUND

Multisite pacing has been suggested to be superior to single-site pacing for prevention of atrial tachyarrhythmias. However, the underlying electrophysiological mechanisms are undetermined at the moment, as is the rationale for the selection of pacing locations and the number of pacing sites.

METHODS

In 13 normal beagle dogs, an epicardial multielectrode (128 bipoles) and a multiplexer mapping system were used to reconstruct epicardial atrial activation patterns obtained during simultaneous stimulation from up to four electrodes located in the high and low right and left atrium, respectively. For all pacing modes (single-, dual-, triple- and quadruple-site pacing), total activation times and local effective refractory periods at eight randomly selected sites as well as local recovery intervals were determined. In a subgroup of five dogs, total epicardial activation times were also obtained during single-site septal stimulation (septal group).

RESULTS

Activation times and local recovery intervals were minimized by triple-site stimulation, whereas a fourth site did not produce further shortening. Septal stimulation produced epicardial activation times comparable to quadruple-site stimulation. Local refractory periods and their dispersion always remained unaffected. Functional conduction blocks apparent during single-site were found to resolve during multisite stimulation.

CONCLUSIONS

Multisite pacing can prevent functional conduction blocks by multidirectional excitation and a reduction in total activation time. Triple-site and, possibly, septal pacing modes are expected to be most efficient because both minimize total activation times and maximize the multidirectionality of excitation. In spite of unaffected local refractory periods, the shortening of local recovery intervals might homogenize atrial repolarization and, thus, contribute to the preventive effects of multisite pacing.  相似文献   


8.
Atrial pacing has been shown to delay the onset of atrial fibrillation (AF) when compared with ventricular pacing in patients with sick sinus syndrome. The role for pacing in the control of AF in patients without bradycardia is uncertain. We performed a randomized, crossover, single-blinded study in 22 patients (14 women, aged 63 +/- 10 years) with paroxysmal AF refractory to treatment with oral sotalol (202 +/- 68 mg/day) and no bradycardic indication for pacing. All patients received a dual-chamber pacemaker with 2 atrial pacing leads positioned at the high right atrium and coronary sinus ostium, respectively. Patients were randomized in a crossover fashion to be paced for 12 weeks, either with high right atrial (RA) pacing at 30 beats/min ("Off") or dual-site RA pacing with an overdrive algorithm that maintained atrial pacing at a rate slightly above the sinus rate ("On"). Treatment on resulted in a significantly higher percentage of atrial pacing and a reduction in atrial ectopic frequency than the treatment off period. The time to the first clinical AF recurrence was prolonged (15 +/- 17 to 50 +/- 35 days, p = 0.006), and total AF burden was reduced (45 +/- 34% vs 22 +/- 29%, p = 0.04) in the on-treatment phase. However, there was no difference in AF checklist symptom scores or overall quality-of-life measures. Dual-site RA pacing with continued sinus overdrive prolonged the time to AF recurrence and decreased AF burden in patients with paroxysmal AF. The absence of a major impact on symptom control suggests that pacing should be used as an adjunctive therapy with other treatment modalities for AF.  相似文献   

9.

Introduction

Dual-site right atrial pacing (DAP) produces electrical atrial resynchronization but its long-term effect on the atrial mechanical function in patients with refractory atrial fibrillation (AF) has not been studied.

Methods

Drug-refractory paroxysmal (PAF) and persistent AF (PRAF) patients previously implanted with a dual-site right atrial pacemaker (DAP) with minimal ventricular pacing modes (AAIR or DDDR mode with long AV delay) were studied. Echocardiographic structural (left atrial diameter [LAD] and left ventricular [LV] end diastolic diameter [EDD], end systolic diameter [ESD]) and functional (ejection fraction [EF]) parameters were serially assessed prior to, after medium-term (n?=?39) and long-term (n?=?34) exposure to DAP.

Results

During medium-term follow-up (n?=?4.5 months), there was improvement in left atrial function. Mean peak A wave flow velocity increased with DAP as compared to baseline (75?±?19 vs. 63?±?23 cm/s, p?=?0.003). The long-term impact of DAP was studied with baseline findings being compared with last follow-up data with a mean interval of 37?±?25 (range 7–145) months. Mean LAD declined from 45?±?5 mm at baseline to 42?±?7 mm (p?=?0.003). Mean LVEF was unchanged from 52?±?9 % at baseline and 54?±?6 % at last follow-up (p?=?0.3). There was no significant change in LV dimensions with mean LVEDD being 51?±?6 mm at baseline and 53?±?5 mm at last follow-up (p?=?0.3). Mean LVESD also remained unchanged from 35?±?6 mm at baseline to 33?±?6 mm at last follow-up (p?=?0.47). During long-term follow-up, 30 patients (89 %) remained in sinus or atrial paced rhythm as assessed by device diagnostics at 3 years.

Conclusions

DAP can achieve long-term atrial reverse remodeling and preserve LV systolic function. DAP when added to antiarrhythmic drug (AAD) and/or catheter ablation (ABL) maintains long-term rhythm control and prevents AF progression in elderly refractory AF patients. Reverse remodeling with DAP may contribute to long-term rhythm control.  相似文献   

10.
INTRODUCTION: Prior studies suggest that right ventricular apical (RVA) pacing has deleterious effects. Whether the right ventricular outflow tract (RVOT) is a more optimal site for permanent pacing in patients with congestive heart failure (CHF) has not been established. METHODS AND RESULTS: We conducted a randomized, cross-over trial to determine whether quality of life (QOL) is better after 3 months of RVOT than RVA pacing in 103 pacemaker recipients with CHF, left ventricular (LV) systolic dysfunction (LV ejection fraction < or = 40%), and chronic atrial fibrillation (AF). An additional aim was to compare dual-site (RVOT + RVA, 31-ms delay) with single-site RVA and RVOT pacing. QRS duration was shorter during RVOT (167 +/- 45 ms) and dual-site (149 +/- 19 ms) than RVA pacing (180 +/- 58 ms, P < 0.0001). At 6 months, the RVOT group had higher (P = 0.01) role-emotional QOL subscale scores than the RVA group. At 9 months, there were no significant differences in QOL scores between RVOT and RVA groups. Comparing RVOT to RVA pacing within the same patient, mental health subscale scores were better (P = 0.03) during RVOT pacing. After 9 months of follow-up, LVEF was higher (P = 0.04) in those assigned to RVA rather than RVOT pacing between months 6 and 9. After 3 months of dual-site RV pacing, physical functioning was worse (P = 0.04) than during RVA pacing, mental health was worse (P = 0.02) than during RVOT pacing, and New York Heart Association (NYHA) functional class was slightly better (P = 0.03) than during RVOT pacing. There were no other significant differences between RVA, RVOT and dual-site RV pacing in QOL scores, NYHA class, distance walked in 6 minutes, LV ejection fraction, or mitral regurgitation. CONCLUSION: In patients with CHF, LV dysfunction, and chronic AF, RVOT and dual-site RV pacing shorten QRS duration but after 3 months do not consistently improve QOL or other clinical outcomes compared with RVA pacing.  相似文献   

11.
Atrial Cardioversion Using a Single Atrial Lead System. Introduction: Clinical studies have shown that electrical conversion of atrial fibrillation (AF) is feasible with transvenous catheter electrodes at low energies. We developed a single atrial lead system that allows atrial pacing, sensing, and defibrillation to improve and facilitate this new therapeutic option. Methods and Results: The lead consists of a tripolar sensing, pacing, and defibrillation system. Two defibrillation coil electrodes are positioned on a stylet-guided lead. A ring electrode located between the two coils serves as the cathode for atrial sensing and pacing. We used this lead to cardiovert patients with acute or chronic AE. The distal coil was positioned in the coronary sinus, and the proximal coil and the ring electrode in the right atrium. R wave synchronized biphasic shocks were delivered between the two coils. Atrial signal detection and pacing were performed using the proximal coil and the ring electrode. Eight patients with acute AF (38 ± 9 min) and eight patients with chronic AF (6.6 ± 5 months) were included. The fluoroscopy time for lead placement was 3.5 ± 4.3 minutes. The atrial defibrillation threshold was 2.0 ± 1.4 J for patients with acute AE and 9.2 ± 5.9 J for patients with chronic AF (P < 0.01). The signal amplitude detected was 1.7 ± 1.1 mV during AF and 4.0 ± 2.9 mV after restoration of sinus rhythm (P < 0.001). Atrial pacing was feasible at a threshold of 4.4 ± 3.3 V (0.5-msec pulse width). Conclusions: Atrial signal detection, atrial pacing, and low-energy atrial defibrillation using this single atrial lead system is feasible in various clinical settings. Tbis system might lead to a simpler, less invasive approach for internal atrial cardioversion.  相似文献   

12.
OBJECTIVES: To evaluate the preventive efficacy of multisite and septal atrial pacing in an experimental model. METHODS: Sterile right atrial pericarditis was induced in 12 foxhounds to provide an anatomical substrate for atrial fibrillation (AF). As a trigger mechanism, atrial extrasystoles were simulated by constant asynchronous pacing at a cycle length of 1000 ms from randomly selected right or left atrial electrodes, using a biatrial epicardial multielectrode with 128 bipoles. Additionally, a transvenous pacing lead was screwed into the interatrial septum. Four electrodes located in the high and low right (HRA/LRA) and left atrium (HLA/LLA) were selected for preventive multisite stimulation. Constant pacing at a cycle length 30 ms below sinus rate was applied from the following site(s): HRA, septal, HRA+LRA, HRA+LLA, HRA+LRA+LLA and HRA+LRA+HLA+LLA (order randomized). Number and duration of AF episodes were studied during 10 min intervals, separated by 5 min pauses, respectively. To validate the model, the protocol was repeated 10 min after i.v. bolus administration of D,L-sotalol (1 mg/kg body weight). RESULTS: The number of AF episodes decreased with increasing number of pacing sites, reaching statistical significance compared to HRA stimulation for quadruple-site and single-site septal pacing only (P<0.05). Single-site septal was as efficient as quadruple-site pacing in suppressing AF. The duration of AF episodes was not significantly affected by the pacing configuration. D,L-sotalol almost completely suppressed AF irrespective of the pacing configuration used. CONCLUSIONS: In this novel experimental model, quadruple-site and septal pacing effectively suppress paroxysmal AF.  相似文献   

13.
P-wave dispersion is a non invasive indicator of intra-atrial conduction heterogeneity producing substrate for reentry, which is a pathophysiological mechanism of atrial fibrillation. The relationship between P-wave dispersion (PD) and atrial fibrillation (AF) in Myotonic dystrophy type 1 (DM1) patients is still unclear. Atrial Preference Pacing (APP) is an efficient algorithm to prevent paroxysmal AF in patients implanted with dual-chamber pacemaker. Aim of our study was to evaluate the possible correlation between atrial preference pacing algorithm, P-wave dispersion and AF burden in DM1 patients with normal cardiac function underwent permanent dual-chamber pacemaker implantation.We enrolled 50 patients with DM1 (age 50.3 ± 7.3; 11 F) underwent dual-chamber pacemaker implantation for various degree of atrioventricula block. The study population was randomized following 1 months stabilization period to APP algorithm features programmed OFF or ON. Patients were assessed every 3 months for the first year, and every 6 months thereafter up to 3 years. At each follow-up visit, we counted: the number of premature atrial beats, the number and the mean duration of AF episodes, AF burden and the percentage of atrial and ventricular pacing.APP ON Group showed lower number of AF episodes (117 ± 25 vs. 143 ± 37; p = 0.03) and AF burden (3059 ± 275 vs. 9010 ± 630 min; p < 0.04) than APP OFF Group. Atrial premature beats count (44903 ± 30689 vs. 13720 ± 7717 beats; p = 0.005) and Pwave dispersion values (42,1 ± 11 ms vs. 29,1 ± 4,2 ms, p = 0,003) were decreased in APP ON Group. We found a significant positive correlation between PD and AF burden (R = 0,8, p = 0.007).Atrial preference pacing algorithm, decreasing the number of atrial premature beats and the P-wave dispersion, reduces the onset and perpetuator factors of AF episodes and decreases the AF burden in DM1 patients underwent dual chamber pacemaker implantation for various degree of atrioventricular blocks and documented atrial fibrillation.Key words: atrial fibrillation, Myotonic Dystrophy, atrial preference pacing  相似文献   

14.
ObjectivesThis study examined the effect of brief duration atrial fibrillation on left atrial and left atrial appendage mechanical function in humans with structural heart disease.BackgroundLeft atrial dysfunction and the development of spontaneous echo contrast (SEC) may follow the cardioversion of atrial fibrillation (AF) to sinus rhythm. This phenomenon has been termed “stunning” and is implicated in the development of atrial thrombus and embolic stroke. The effects of brief duration AF on left atrial mechanical function in humans are unknown.MethodsTwenty-four patients (23 men, aged 59.1 ± 12.7 years) with significant structural heart disease (ejection fraction 31.2 ± 9.0%, left atrial diameter 4.9 ± 0.4 cm) undergoing implantation of a ventricular cardiodefibrillator underwent transesophageal echocardiography to evaluate left atrial appendage emptying velocities (LAAeV) and SEC before, during and after a 15-min period of AF induced by rapid right atrial pacing. Atrial fibrillation was then permitted to terminate spontaneously within 5 min or was reverted with an endocardial direct current shock. Velocities and SEC were assessed in sinus rhythm pre-AF, during AF and immediately, 5 and 10 min after reversion to sinus rhythm.ResultsAtrial fibrillation terminated spontaneously in 10 patients after 16.1 ± 1.0 min. Endocardial direct current (DC) cardioversion of 10.4 ± 6.4 J was required in 14 patients after AF lasting 20 min. Mean LAAeV pre-AF (50.0 ± 17.5 cm/s) was not significantly different to LAAeV immediately (52.8 ± 16.7 cm/s), 5 min (54.3 ± 16.4 cm/s) or 10 min (53.7 ± 15.7 cm/s) after reversion to sinus rhythm. Atrial stunning defined as a reduction in LAAeV of >20% was not observed in any patient. Fourteen of 24 patients (58%) developed SEC during AF, which resolved within 30 s of AF termination. There were no significant differences between LAAeV in those patients reverting with DC shock (pre-AF 50.6 ± 16.2 cm/s vs. immediately post-AF 54.7 ± 16.6 cm/s) or in those patients with spontaneous reversion (pre-AF 48.9 ± 20.2 cm/s vs. immediately post-AF 49.8 ± 17.3 cm/s).ConclusionsSignificant left atrial stunning was not observed after brief duration AF in humans with structural heart disease. Transient left atrial SEC develops in a significant proportion of these patients during AF but resolves rapidly on reversion to sinus rhythm. These findings suggest that the risk of thromboembolism may be low after brief duration AF that terminates either spontaneously or with an endocardial DC shock even in patients with significant structural heart disease. These findings have important implications for recipients of implantable devices that are capable of atrial defibrillation in response to AF.  相似文献   

15.
Optional statement Ablation of the atrioventricular conduction system and pacemaker implantation is the preferred procedure for patients with atrial fibrillation (AF) in whom a rate control strategy has been selected but in whom rate-controlling medications are intolerable or ineffective. Selection of standard right ventricular (RV) pacing versus biventricular pacing is individualized, based on the degree and etiology of left ventricular dysfunction. Atrial-based pacing is clearly preferable to ventricular-based pacing in patients with sick sinus syndrome, because it leads to a reduction in the development of AF. Emerging evidence indicates that excess RV pacing is deleterious, increasing AF, heart failure, and possibly mortality. Therefore, physiologic pacing with minimization of RV pacing is desirable. Atrial pacing algorithms that increase the frequency of atrial pacing have shown modest efficacy in the prevention of AF. Use of atrial pacing algorithms is reasonable for patients with a history of AF and standard bradycardia indications for permanent pacing in whom maintenance of sinus rhythm is desirable. Studies assessing novel and multiple site atrial pacing therapies have mixed results, without compelling evidence of clinically important benefit. The exceptions are biatrial and right atrial overdrive pacing immediately after cardiac surgery. Several studies have shown effective suppression of postoperative AF with their use. Device therapy (eg, atrial antitachycardia pacing and defibrillation) for the termination of AF is effective in reducing arrhythmia burden. However, improvement in clinically relevant end points is not established and indications are not clearly defined. If a patient lacks an indication for an implantable cardioverter-defibrillator, we do not offer atrial defibrillation as a treatment option. Atrial arrhythmias may be better prevented by programming to avoid ventricular pacing than by specific atrial interventions.  相似文献   

16.
Stretch Slows Conduction in the Human Atrium . Introduction: The mechanisms by which atrial stretch favors the development of a substrate for atrial fibrillation (AF) are not fully understood. In this study, the role of stretch‐induced conduction changes in the creation of a proarrhythmic substrate has been investigated by quantifying the spatial distribution of local conduction velocities (CVs) in the human atrium during acute atrial dilatation. Methods and Results: Electroanatomic mapping of right atrial activation was performed in 10 patients during coronary sinus pacing under control condition and during acute atrial dilatation. Atrial stretch was obtained by simultaneous atrioventricular (AV) pacing at a cycle length of 450–500 ms. Local CVs were accurately estimated by applying the principle of triangulation and spatially mapped over the whole right atrial endocardial surface. Simultaneous AV pacing significantly increased right atrial volume from 72.0 ± 29.0 to 86.3 ± 31.3 mL (P < 0.001). The 23% increase in atrial volume resulted in an overall decrease in atrial CV from 65.8 ± 5.9 to 55.2 ± 7.2 cm/s (P < 0.001) and an increased incidence of slow conduction sites or local conduction blocks from 10.3 ± 4.2% to 15.9 ± 7.7% (P < 0.01). Acute atrial dilatation concurrently increased AF vulnerability, with 6 of 10 patients developing AF episodes under stretch condition. Conclusion: Quantification of stretch‐induced conduction changes in the human atrium is feasible by combining simultaneous AV pacing and CV map construction. Acute atrial dilatation results in conduction slowing and significant increase in AF vulnerability, suggesting the role of stretch‐induced conduction disturbances in the creation of a substrate for AF. (J Cardiovasc Electrophysiol, Vol. 22, pp. 394‐401)  相似文献   

17.
Atrial resynchronization resulting from simultaneous pacing of the atria may adjust inter- or intra-atrial asynchrony and prevent atrial fibrillation (AF). The purpose of this study was to assess the efficacy of bi-atrial pacing (BAP) in preventing AF, and the safety of this system. The effect of BAP was compared with single site right atrial pacing (RAP) in 6 patients with sick sinus syndrome and paroxysmal AF in a prospective switchover trial. P wave duration was significantly reduced during BAP (p<0.01). Pacing threshold, atrial wave amplitude and the lead impedance presented no significant differences at implant, 1 week and 3 months after implantation, respectively (NS). The number of AF episodes significantly decreased during both RAP and BAP compared with the control (p<0.01). Although the number of premature atrial contractions was significantly less during BAP than RAP (p<0.05), there were no significant differences of AF episodes between the two. The percentage of pacing was achieved in only 70% during both pacing modes. BAP was safe and reliable in this follow-up period and can prevent AF. These findings provide encouragement for further study and observation of BAP to prevent AF.  相似文献   

18.
INTRODUCTION: Patients receiving VVI pacemakers have a higher incidence of paroxysmal atrial fibrillation (AF) than those receiving DDD pacemakers. However, the mechanism behind the difference is not clear. The purpose of this study was to investigate whether atrial electrophysiology and the autonomic nervous system play a role in the occurrence of AF during AV pacing. METHODS AND RESULTS: The study population consisted of 28 patients who had (group I, n = 15) or did not have (group II, n = 13) AF induced by a single extrastimulus during pacing with different AV intervals. Atrial pressure, atrial size, atrial effective refractory periods, and atrial dispersion were evaluated during pacing with different AV intervals. Twenty-four-hour heart rate variability and baroreflex sensitivity also were examined. Atrial pressure, atrial size, effective refractory periods in the right posterolateral atrium and distal coronary sinus, and atrial dispersion increased as the AV interval shortened from 160 to 0 msec. During AV pacing, group I patients had greater minimal (52+/-17 vs 25+/-7 msec; P < 0.005) and maximal (76+/-16 vs 36+/-9 msec; P < 0.005) atrial dispersion than group II patients. The differences in atrial size and atrial dispersion among different AV intervals were greater in patients with AF than in those without AF. Baroreflex sensitivity (6.6+/-1.7 vs 3.9+/-1.0; P < 0.00005), but not heart rate variability, was higher in patients with AF than in those without AF. CONCLUSION: Abnormal atrial electrophysiology and higher vagal reflex activity can play important roles in the genesis of AF in patients receiving pacemakers.  相似文献   

19.
观察房间隔起搏对阵发性心房颤动 (AF)患者最大P波时限 (Pmax)及P波离散度 (Pd)的影响 ,探悉房间隔起搏防治AF发作的电生理机制。对 2 1例阵发性AF患者和 2 6例室上性心动过速行射频消融术无阵发性AF患者 ,分别进行右心耳和房间隔起搏 ,比较不同部位起搏对阵发性AF和无阵发性AF患者的Pmax和Pd影响。结果 :阵发性AF患者较无阵发性AF患者Pmax和Pd值明显大 (分别为 1 35± 1 5vs 1 1 9± 1 4ms ,P <0 .0 5 ;36 .5± 9.2vs 1 9.7± 7.1ms ,P <0 .0 1 ) ;房间隔起搏使阵发性AF患者Pd、Pmax显著下降 (分别为 2 3 .4± 8vs 36 .5± 9.2ms ,1 2 0± 1 1vs1 35± 1 5ms,P均 <0 .0 5) ;右心耳起搏使无阵发性AF患者Pmax和Pd明显增加 (分别为 1 32± 1 2vs 1 1 9± 1 4ms,2 5 .5± 8.5vs 1 9.7± 7.1ms ,P均 <0 .0 5)。结论 :右心耳起搏能够使无阵发性AF患者Pmax和Pd值增加。房间隔起搏能够明显降低阵发性AF患者Pmax、Pd ,纠正房内或房间传导延缓 ,改善心房内电活动的各向异性 ,防治AF发作  相似文献   

20.
BACKGROUND: Recently, several temporary multisite pacing methods have been developed for prevention of postoperative atrial fibrillation (AF). HYPOTHESIS: In this study, we evaluated the effect of triple-site temporary triggered pacing in the AAT mode on the development of AF in patients undergoing coronary artery bypass graft (CABG) at high risk for developing postoperative AF. METHODS: A total of 70 patients undergoing CABG were randomly assigned either to pacing group (study group, n = 35 patients) or to no pacing group (control group, n = 35 patients). The external pacemaker was programmed to pace at the atrial triggered mode at a lower rate of 40 beats/min for 4 days. RESULTS: Atrial fibrillation, defined as lasting > 30 s, occurred in 4 patients (11.4%) in the study group and in 16 patients (45.7%) in the control group (p = 0.003). Sustained AF, defined as AF lasting > 10 min, also was observed less frequently in the study group than in the control group (11.6 vs. 37.1%, p = 0.024). Triple-site triggered atrial pacing was observed to reduce the incidence of AF by 75% and the incidence of sustained AF by 69%. CONCLUSIONS: We believe that multiple-site temporary pacing in the triggered mode is an effective way of preventing postoperative AF. This technique may be used especially in patients at high risk of developing AF.  相似文献   