胎儿四腔心筛查的价值分析
引用本文:吴瑛,王慧芳,任景惠,卢峻,张少文,梁海南.胎儿四腔心筛查的价值分析[J].中国医学影像技术,2001,17(9):888-889.
作者姓名:吴瑛  王慧芳  任景惠  卢峻  张少文  梁海南
作者单位:1. 暨南大学医学院 第二附属医院暨深圳市人民医院超声诊断科
2. 暨南大学医学院 第二附属医院暨深圳市人民医院 计划生育科
摘    要:目的:探讨将胎儿四腔心作为先天性心脏病筛查方法的优缺点,探讨提高胎儿先心病早期诊断的最佳方法。方法:970例中孕以后例行超声检查的孕妇(其中310例高危孕妇),进行胎儿四腔心切面的筛选性检查,发现可疑异常后加做全套胎儿超声心动图,将结果与胎儿尸检查或产后超声心动图相对照。结果:胎儿四腔心的显示率为100%,胎心照射时间<5min,共检出胎儿心脏异常9例(0.93%),其中尸检证实5例,漏诊大动脉畸形2例(0.2%)。结论:胎儿四腔心作为先心病的初筛手段简便易行,可发现大多数先心病,但会漏诊大动脉畸形,故最佳的筛查组合应为四腔心+两心室流出道切面。

关 键 词:胎儿  超声心动图  无天性心脏病  产前超声检查
文章编号:1003-3289(2001)09-0888-02
收稿时间:2001/4/30 0:00:00
修稿时间:2001年4月30日

Effect of Fetal Four-Chamber View on Routine Prenatal Ultrasonographic Screening
WU Ying,WANG Hui-fang,REN Jing-hui,LU Jun,ZHANG Shao-wen and LIANG Hai-nan.Effect of Fetal Four-Chamber View on Routine Prenatal Ultrasonographic Screening[J].Chinese Journal of Medical Imaging Technology,2001,17(9):888-889.
Authors:WU Ying  WANG Hui-fang  REN Jing-hui  LU Jun  ZHANG Shao-wen and LIANG Hai-nan
Affiliation:Shenzhen People's Hospital, Shenzhen 518020, China;Shenzhen People's Hospital, Shenzhen 518020, China;Shenzhen People's Hospital, Shenzhen 518020, China;Shenzhen People's Hospital, Shenzhen 518020, China;Shenzhen People's Hospital, Shenzhen 518020, China
Abstract:Objective To assess the accuracy and limitation of fetal four chamber view in detecting the majority of cardiac defects, and to find the best way of prenatal diagnosis in congenital heart disease. Methods 970 prenatal women on routine ultrasonic screening(including 310 high risk patients) underwent fetal four chamber view examination. The detailed fetal echocardiography was performed for the patients suspected fetal cardiac abnormalities. Accuracy of the prenatal ultrasonographic diagnosis was evaluated from the fetal autopsy and postnatal echocardiography. Results All fetus were scanned with standard four chamber, it need less than 5 minutes for this view. 9 cases (0.93%) of congenital heart disease were detected prenatally by four chamber view, of them,5 cases were confirmed by autopsy. Postnatal assessment found 2 cases (0.2%) with malformations of the great artery that had not been detected prenatally. Conclusion It is a simple way to use four chamber view in detecting majority of congenital heart diseses, but poor diagnostic accuracy in malformations of the great arteries. Therefore, the four chamber and outflow tract views were advocated for routine prenatal ultrasonography.
Keywords:Fetal echocardiography  Congenital heart disease  Prenatal ultrasonographic screening