首页 | 本学科首页   官方微博 | 高级检索  
     


Failure of the fluorescent antibody reaction to identify penicillinase-producing gonococci.
Authors:S A Waitkins and R D Anderson
Abstract:
The fluorescent antibody test is now widely used to confirm the identity of Neisseria gonorrhoeae but may fail to identify penicillinase-producing strains (PPNG). This problem arises when conjugates are used that incorporate only gonococci that are not penicillinase-producers. We have shown that conjugates prepared from mixtures of PPNG and non-penicillinase producing gonococci give good fluorescent reactions. This difference in the reactions of PPNG strains is clearly related to their penicillinase-producing abilities, further study of the antigenic relation between penicillinase production and the antigenic structure of N gonorrhoeae is evidently required.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号