Quantitative magnetic resonance spectroscopy at 3T based on the principle of reciprocity
Authors:Niklaus Zoelch  Andreas Hock  Anke Henning
Affiliation:1. Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland;2. Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland;3. Hospital of Psychiatry, Department of Psychiatry, Psychotherapy and Psychosomatics, University of Zurich, Zurich, Switzerland;4. Max Plank Institute for Biological Cybernetics, Tuebingen, Germany
Abstract:Quantification of magnetic resonance spectroscopy signals using the phantom replacement method requires an adequate correction of differences between the acquisition of the reference signal in the phantom and the measurement in vivo. Applying the principle of reciprocity, sensitivity differences can be corrected at low field strength by measuring the RF transmitter gain needed to obtain a certain flip angle in the measured volume. However, at higher field strength the transmit sensitivity may vary from the reception sensitivity, which leads to wrongly estimated concentrations. To address this issue, a quantification approach based on the principle of reciprocity for use at 3T is proposed and validated thoroughly. In this approach, the RF transmitter gain is determined automatically using a volume‐selective power optimization and complemented with information from relative reception sensitivity maps derived from contrast‐minimized images to correct differences in transmission and reception sensitivity. In this way, a reliable measure of the local sensitivity was obtained. The proposed method is used to derive in vivo concentrations of brain metabolites and tissue water in two studies with different coil sets in a total of 40 healthy volunteers. Resulting molar concentrations are compared with results using internal water referencing (IWR) and Electric REference To access In vivo Concentrations (ERETIC). With the proposed method, changes in coil loading and regional sensitivity due to B1 inhomogeneities are successfully corrected, as demonstrated in phantom and in vivo measurements. For the tissue water content, coefficients of variation between 2% and 3.5% were obtained (0.6–1.4% in a single subject). The coefficients of variation of the three major metabolites ranged from 3.4–14.5%. In general, the derived concentrations agree well with values estimated with IWR. Hence, the presented method is a valuable alternative for IWR, without the need for additional hardware such as ERETIC and with potential advantages in diseased tissue.
Keywords:human study  metabolite concentrations  normal brain  principle of reciprocity  proton magnetic resonance spectroscopy  spectroscopic quantitation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号