首页 | 本学科首页   官方微博 | 高级检索  
     


Hollow organosilica beads as reference particles for optical detection of extracellular vesicles
Authors:Z. Varga  E. van der Pol  M. Pálmai  R. Garcia‐Diez  C. Gollwitzer  M. Krumrey  J.‐L. Fraikin  A. Gasecka  N. Hajji  T. G. van Leeuwen  R. Nieuwland
Affiliation:1. Biological Nanochemistry Research Group, Institute of Materials and Environmental Chemistry, Research Center for Natural Sciences, Hungarian Academy of Sciences, Budapest, Hungary;2. Department of Biophysics and Radiation Biology, Semmelweis University, Budapest, Hungary;3. Laboratory of Experimental Clinical Chemistry, Academic Medical Center of the University of Amsterdam, Amsterdam, the Netherlands;4. Department of Biomedical Engineering and Physics, Academic Medical Center of the University of Amsterdam, Amsterdam, the Netherlands;5. Vesicle Observation Center, Academic Medical Center of the University of Amsterdam, Amsterdam, the Netherlands;6. Physikalisch‐Technische Bundesanstalt (PTB), Berlin, Germany;7. Spectradyne LLC, Torrance, CA, USA;8. 1st Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
Abstract:

Essentials

  • Standardization of extracellular vesicle (EV) measurements by flow cytometry needs improvement.
  • Hollow organosilica beads were prepared, characterized, and tested as reference particles.
  • Light scattering properties of hollow beads resemble that of platelet‐derived EVs.
  • Hollow beads are ideal reference particles to standardize scatter flow cytometry research on EVs.

Summary

Background

The concentration of extracellular vesicles (EVs) in body fluids is a promising biomarker for disease, and flow cytometry remains the clinically most applicable method to identify the cellular origin of single EVs in suspension. To compare concentration measurements of EVs between flow cytometers, solid polystyrene reference beads and EVs were distributed in the first ISTH‐organized interlaboratory comparison studies. The beads were used to set size gates based on light scatter, and the concentration of EVs was measured within the size gates. However, polystyrene beads lead to false size determination of EVs, owing to the mismatch in refractive index between beads and EVs. Moreover, polystyrene beads gate different EV sizes on different flow cytometers.

Objective

To prepare, characterize and test hollow organosilica beads (HOBs) as reference beads to set EV size gates in flow cytometry investigations.

Methods

HOBs were prepared with a hard template sol‐gel method, and extensively characterized for morphology, size, and colloidal stability. The applicability of HOBs as reference particles was investigated by flow cytometry with HOBs and platelet‐derived EVs.

Results

HOBs proved to be monodisperse with a homogeneous shell thickness. Two‐angle light‐scattering measurements by flow cytometry confirmed that HOBs have light‐scattering properties similar to those of platelet‐derived EVs.

Conclusions

Because the structure and light‐scattering properties HOBs resemble those of EVs, HOBs with a given size will gate EVs of the same size. Therefore, HOBs are ideal reference beads with which to standardize optical measurements of the EV concentration within a predefined size range.
Keywords:cell‐derived microparticles  exosomes  extracellular vesicles  flow cytometry  microspheres
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号