Comparison of a Multiplexed Herpes Simplex Virus Type-Specific Immunoglobulin G Serology Assay to Immunoblot, Western Blot, and Enzyme-Linked Immunosorbent Assays |
| |
Authors: | Thomas B. Martins Ryan J. Welch Harry R. Hill Christine M. Litwin |
| |
Affiliation: | Associated Regional and University Pathologists Institute for Clinical and Experimental Pathology, Salt Lake City, Utah,1. Departments of Pathology,2. Pediatrics,3. Medicine, University of Utah School of Medicine, Salt Lake City, Utah4. |
| |
Abstract: | The human herpes simplex virus (HSV) is highly pathogenic, with infections caused by two distinct antigenic types, HSV-1 and HSV-2. Differentiation of antibodies to these specific antigens can provide useful information for the diagnosis of subclinical or undiagnosed HSV-2 infections, as well as for reducing the risk of maternal transfer of HSV to the neonate. In this study, a multiplex assay capable of concurrent detection of HSV-1 and -2 immunoglobulin G (IgG) antibodies was compared to immunoblot, Western blot, and enzyme-linked immunosorbent assays. Agreement of the multiplex assay was 95% or greater (n = 332) for both HSV-1 and -2 compared to the three assays. Sensitivities for HSV-1 ranged from 94.9 to 97.9%, with specificities of 93 to 97%. For HSV-2, the sensitivity and specificity ranges were 92.6 to 98.9% and 98.3 to 98.7%, respectively. Our studies show that the multiplexed microsphere-based assay offers a sensitive and specific alternative method for the detection HSV-1 and -2 type-specific antibodies. Advantages of the multiplex assay include multiple results per assay, the inclusion of internal controls for each specimen, and higher throughput of results. |
| |
Keywords: | |
|
|